Confronting the Dragon: Geology, Geologists, and the Nevada National Security Site
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Geothermal play fairway analysis is a concept adopted from the oil industry aimed at improving the efficiency and success rate of geothermal exploration and drilling. It involves integration of multiple geologic and geophysical parameters indicative of geothermal activity as a means of identifying the most promising areas for new geothermal development. This includes the evaluation of the relative favorability of known, undeveloped geothermal systems, as well as assessing the probability of a particular area for hosting a relatively robust blind system (>~130°C). Finally, blind systems lack surface hot springs and steam vents and are thought to comprise the majority of geothermal systems in the Great Basin region.
This study has synthesized geological, geochemical, and geophysical data sets to elucidate the structural architecture and history of the Crescent basin in order to assess its geothermal potential. The Crescent basin is a complex composite basin, consisting primarily of multiple east-tilted half grabens and horst blocks bounded by several major faults of variable strike. Fault kinematic data indicate a present-day west-northwesttrending least principal stress, which in turn suggests that north-northeast-striking normal faults have relatively high slip and dilation tendency. However, a protracted history of changing Cenozoic extension directions has produced a mosaic of fault patterns, which has generated both segmented fault geometries and multiple fault intersections. These structural complexities have ultimately primed the basin for geothermal activity. Detailed analyses and application of the play fairway methodology have respectively denoted and ranked 12 favorable structural settings capable of hosting geothermal fluids in the Crescent basin. Of the 12 favorable structural settings, five were identified as having a higher likelihood of hosting a relatively high-temperature (>130°C) geothermal system, including Hand-Me-Down Creek, Hot Springs Point, and three other unnamed areas. The Hand-Me-Down Creek hybrid structural setting along the Crescent Valley fault is the only documented relatively high temperature geothermal system identified in the basin. It contains an active 87°C hot spring actively depositing sinter and geothermometry greater than 170°C (possibly >180°C). Future exploration efforts at Hand-Me-Down Creek would benefit from focusing on targeting high permeability zones at depth utilizing densely spaced electromagnetic surveys, fluid flow modeling, and selective drilling that targets specific fault intersections within the greater step-over at depth. The Hot Springs Point hybrid structural setting along the Dry Hills fault hosts a geothermal system, but geothermometry, spring temperatures, and well temperatures indicate that fluids do not exceed ~100°C. Three other relatively promising areas include a fault intersection in the central part of the basin and two step-overs (relay ramps) along the Crescent Valley fault, but additional exploration is needed at these sites, such as 2-m temperature surveys in the dry season, measuring deeper subsurface temperatures through temperature-gradient drilling, and collecting water samples through geoprobe drilling to estimate geothermometry.
This study assessed the potential for high-temperature (≥130°C) blind geothermal systems in southeastern Gabbs Valley by employing a geothermal play fairway analysis approach involving integration of geologic, geophysical, and geochemical datasets. Gabbs Valley is a complex, tectonically active basin within the Great Basin on the boundary between the transtensional central Walker Lane domain and extensional Basin and Range province. The termination of the Petrified Springs fault, a major dextral fault of the central Walker Lane, in an array of normal faults indicates that southeastern Gabbs Valley occupies a displacement transfer zone, which is a favorable structural setting for geothermal activity. The displacement transfer zone is a structurally complicated area with many faults of varying geometries, kinematics, and ages. A substantial northwest-trending gravity high within the south-central part of southeastern Gabbs Valley is produced from offsets along concealed northwest-striking dextral-normal faults that intersect strands of north-northeast-to east-northeast-striking normal faults. This area of tightly spaced faults and fault intersections is a particularly favorable structural setting within the broader-scale displacement transfer zone. Multiple lines of direct and indirect evidence suggest the presence of a relatively high-temperature (≥130°C) blind geothermal system in this area, including collocated intersecting gravity gradients, magnetic-low, low-resistivity, and 2-m temperature anomaly. Potentially related, water samples from agricultural wells ~7 km northwest of the 2-m anomaly yield geothermometers indicating subsurface fluid temperatures of 130-140°C. Six temperature-gradient holes were drilled to target the extent of the shallow-temperature and geophysical anomalies to define the geothermal system in southeastern Gabbs Valley. Two wells contained high temperatures exceeding boiling with bottom-hole temperatures ii of 114.5°C and 124.9°C, respectively, and the remaining wells displayed elevated to background temperatures ranging from 79.2°C to 28.7°C. The observed temperature gradients for the two hottest drill holes necessitate drill-hole intercepts of convecting hydrothermal fluids. The 2-m survey is spatially and thermally consistent with the temperature-gradient holes and constrains the core of upflow at a shallow depth interval (<250m) to an area <0.5-1 km west-southwest of the hottest drill hole. The zone of inferred upwelling occupies the area corresponding to the center of the magnetic-low. This project has several significant implications. The newly discovered blind geothermal system in southeastern Gabbs Valley may be capable of supporting a binary-type geothermal power plant. This detailed study provides an initial validation of the play fairway approach to geothermal exploration. It also demonstrates both the broad applicability of the play fairway exploration strategy and the large untapped potential for commercial-grade blind geothermal systems in many of the basins in the Great Basin region.
Presentation will be given to the Underground Nuclear Weapon Testing Orientation Program, Webex meeting, on March 9. 2021.
Poster to be presented to academics and STEM students from local universities during the American Association of Colleges and Universities (AAC&U) Transforming STEM Higher Education Conference: Back to Broken?, November 3–5, 2022, Arlington, VA (https://secure.aacu.org/iMIS/AACUR/Events/Event_Display.aspx?EventKey=STEM22).
This paper describes the factors that could affect doses to the reasonably maximally exposed individual (RMEI) as a result of a hypothetical extrusive igneous event at Yucca Mountain. Based on available information, there is no evidence that most of the spent fuel in waste packages intersected by a volcanic conduit would be reduced to fine-grained material and subsequently erupted as volcanic ash. (authors)
This paper describes a new Graduate Certificate in Nuclear Packaging (GCNP). Nuclear materials are currently used for large-scale production of electricity without greenhouse gas generation, advanced medical treatments, food sterilization, and sophisticated measurement technologies. In order to benefit from these uses, nuclear materials packaging must be developed, manufactured, inspected, and maintained for storage, transfer, transport, and disposal that protect the public and the environment. The U.S. Department of Energy (DOE) Packaging Certification Program (PCP) originally offered the following ten, one-day to ten-day training courses. 1. Methods for Reviewing Safety Analysis Reports for Packages and Performing Confirmatory Analysis; 2. Welding Criteria for Shipping Containers; 3. Structural Analysis and Acceptance Criteria; 4. Quality Assurance (QA) for Radioactive Material Packaging Training; 5. Application of the American Society of Mechanical Engineers (ASME) Code to Radioactive Material Transportation Packaging; 6. ARG-US Radio Frequency Identification (RFID) System for Management of Nuclear and Radioactive Materials; 7. Packaging Operations and Maintenance; 8. Packaging Leakage Test Training; 9. Management of SARP Preparation; 10. Transport Security of Radioactive Material. These courses were designed in accordance with DOE standards. They were taught at a rigorous graduate-university level by experienced technical staff who are coordinated by Argonne, Lawrence Livermore, and Savannah River National Laboratories. The courses were taught at these Laboratories or nearby locations. The PCP courses are attended by personnel from government agencies, national laboratories, and the nuclear industry, from both inside and outside the United States. Students in these classes have generally earned undergraduate or higher degrees. These courses are designed to assist student with specialized job duties, and may provide them a competitive advantage when seeking employment or promotion in the nuclear packaging and other related fields. (authors)
Geothermal electricity co-production is a viable option for oil reservoirs producing large water cuts with elevated wellhead-observed temperatures. Repurposing existing oil wells significantly reduces initial investment costs historically associated with geothermal resource utilization. The National Renewable Energy Laboratory (NREL), partnering with Gradient Geothermal, Inc. (formerly known as Transitional Energy) and Grant Canyon Oil and Gas, has been tasked to evaluate the feasibility of geothermal electricity co-production at the Blackburn Oil Field with Organic Rankine Cycle (ORC) generators. The Devonian steady-state reservoir has historically been producing high water cuts of 240 degrees F (115.6 degrees C) observed at the wellhead without documented pressure drawdown or thermal breakthrough. An estimated initial reservoir temperature of approx. 260degreesF (126.7 degrees C) has been observed in the field and history-matched in a wellbore production analysis and reservoir simulation. Our objective was to develop a conceptual geological model of the subsurface, simulate a natural-state reservoir, model production scenarios, and complete a technical feasibility analysis to accomplish this task. Through extensive modeling and the use of available proprietary and public data, it was possible simulate three scenarios that indicated minimal thermal decline over the duration of a simulated ten-year production and re-injection scheme.
Geothermal electricity co-production is a viable option for oil reservoirs producing large water cuts with elevated wellhead temperatures. Repurposing existing oil wells significantly reduces initial investment costs historically associated with geothermal resource utilization. The National Renewable Energy Laboratory (NREL), partnering with Gradient Geothermal, Inc. (formerly known as Transitional Energy) and Grant Canyon Oil and Gas, has been tasked to evaluate the feasibility of geothermal electricity co-production at the Blackburn Oil Field with Organic Rankine Cycle (ORC) generators. The Devonian steady-state reservoir has historically been producing high water cuts of 240 degrees F (115.6 degrees C) observed at the wellhead without documented pressure drawdown or thermal breakthrough. An estimated initial reservoir temperature of approx. 260 degrees F (126.7 degrees C) has been observed in the field and history-matched in a wellbore production analysis and reservoir simulation. Our objective was to develop a conceptual geological model of the subsurface, simulate a natural-state reservoir, model production scenarios, and complete a technical feasibility analysis to accomplish this task. Through extensive modeling and the use of available proprietary and public data, it was possible simulate three scenarios that indicated minimal thermal decline over the duration of a simulated ten-year production and re-injection scheme.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.