Design and Experimental Demonastration of a High Pressure Oxy-Methane Combustor
Motivated by the advantages of pressured oxy-combustion, the primary purpose of this experimental study is to design and test a methane-oxygen burner and combustor. The combustor is designed to operate at a firing input of 500 kW and 20 bar chamber pressure. Multiple components of the system are first modeled in CFD to predict performance and design for safety. These components include the methane-oxygen burner, ignition system, and combustor pressurization systems. The simulation is conducted using a 2D domain. Using the expected performance parameters, the experimental system was built and tested. In this particular paper, the test data are presented for 160 kW power inputs and 7 bar chamber pressure. Afterwards, a qualitative and quantitative comparison is performed. For example, in order to pressurize the combustor, the exit area was restricted. The CFD model shows that to achieve a pressure of 7 bar in the chamber an exit diameter of 6.4mm is needed. However, during actual testing a 3.175mm exit diameter orifice is used. This discrepancy between the test results and CFD results is due to the leaking of gases in the combustor. Future testing includes the effect of convective CO2 cooling at the combustor wall and water based cooling at the combustor end cap