Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

A Monte-Carlo method for Coulomb collisions in moderately coupled plasmas

Here, we introduce a new approach for coupling cumulative and single-scattering distributions, extending Monte Carlo methods for Coulomb collisions in weakly coupled plasmas into the moderately coupled regime. Using time steps typical of cumulative-scattering methods, we show that this approach not only recovers leading-order corrections proportional to the inverse Coulomb logarithm but also solves the full Boltzmann collision integral. A key feature of the method is its simplicity: it can be integrated into cumulative-scattering methods for weakly coupled plasmas with only ~ 10 additional lines of code.

Boltzmann collision integral↗

Bayesian forecasting and uncertainty quantifying of stream flows using Metropolis–Hastings Markov Chain Monte Carlo algorithm

This paper presents a Bayesian approach using Metropolis-Hastings Markov Chain Monte Carlo algorithm and applies this method for daily river flow rate forecast and uncertainty quantification for Zhujiachuan River using data collected from Qiaotoubao Gage Station and other 13 gage stations in Zhujiachuan watershed in China. The proposed method is also compared with the conventional maximum likelihood estimation (MLE) for parameter estimation and quantification of associated uncertainties. While the Bayesian method performs similarly in estimating the mean value of daily flow rate, it performs over the conventional MLE method on uncertainty quantification, providing relatively narrower reliable interval than the MLE confidence interval and thus more precise estimation by using the related information from regional gage stations. As a result, the Bayesian MCMC method might be more favorable in the uncertainty analysis and risk management.

58 GEOSCIENCES↗

EXAFS Measurements and Reverse Monte Carlo Modeling of Atomic Structure in Amorphous Ni80P20 Alloys

This paper presents a full account of the EXAFS measurements and reverse Monte Carlo (RMC) modeling of the atomic arrangements and short-to-medium range structure in an amorphous Ni-P alloy, expanding on the description included in our recent publication. The atomic packing is analyzed from the standpoint of solute atoms. The short-to-medium range structure is discussed based on single-solute-centered quasi-equivalent clusters that form due to strong chemical short-range ordering, and the topological order is described in terms of both intra-cluster and inter-cluster dense packing for efficient filling of space. This analysis is also conducted for amorphous Ni80P20 prepared via different processing routes, to observe if the polyamorphism suggested in literature for amorphous Ni-P can be confirmed from the local structure perspective. The structural differences between the proposed polymorphs are apparently subtle and a full resolution of this issue is found to be beyond the capabilities of our EXAFS/RMC modeling approach. The amorphous structural features uncovered are also compared briefly with those observed before in amorphous alloy systems with positive heat of mixing.

36 MATERIALS SCIENCE↗

Bulk and surface diffusion of neodymium in alpha-uranium: Ab initio calculations and kinetic Monte Carlo simulations

A fundamental understanding of lanthanide transport in metallic fuels is critical for high fidelity modeling of the fuel-cladding chemical interaction (FCCI) phenomenon, which can lead to the formation of brittle intermetallic compounds and premature failure of the cladding. Here we report a combined ab initio density functional theory (DFT) and kinetic Monte Carlo (KMC) study of the bulk diffusivity of Nd in α-U, fully taking into account the effect of radiation enhanced diffusion. In this work, the vacancy mechanism is considered to be the dominant mechanism for the bulk diffusion of Nd since a Nd interstitial is found to be intrinsically unstable in α-U. The surface diffusivity of a Nd adatom on α-U (001) surface has been further predicted using KMC simulations parameterized by DFT calculations. The present study suggests that Nd transport via the surface diffusion mechanism can be many orders of magnitude faster than bulk diffusion. Furthermore, the results from the present lower length scale study can be used to inform mesoscale phase-field simulations to determine the effective diffusion coefficient of Nd through α-U with a porous microstructure.

36 MATERIALS SCIENCE↗

Monte Carlo chord length sampling for d-dimensional Markov binary mixtures

The Chord Length Sampling (CLS) algorithm is a powerful Monte Carlo method that models the effects of stochastic media on particle transport by generating on-the-fly the material interfaces seen by the random walkers during their trajectories. This annealed disorder approach, which formally consists of solving the approximate Levermore–Pomraning equations for linear particle transport, enables a considerable speed-up with respect to transport in quenched disorder, where ensemble-averaging of the Boltzmann equation with respect to all possible realizations is needed. However, CLS intrinsically neglects the correlations induced by the spatial disorder, so that the accuracy of the solutions obtained by using this algorithm must be carefully verified with respect to reference solutions based on quenched disorder realizations. When the disorder is described by Markov mixing statistics, such comparisons have been attempted so far only for one-dimensional geometries, of the rod or slab type. In this work we extend these results to Markov media in two-dimensional (extruded) and three-dimensional geometries, by revisiting the classical set of benchmark configurations originally proposed by Adams, Larsen and Pomraning and extended by Brantley. In particular, we examine the discrepancies between CLS and reference solutions for scalar particle flux and transmission/reflection coefficients as a function of the material properties of the benchmark specifications and of the system dimensionality.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emulation of radiation transport in 3D stochastic media using 1D planar Monte Carlo stochastic media radiation transport algorithms

A subset of stochastic media radiation transport problems involves those in which radiation is incident on a thin slab of stochastic material. Particle tracking in 3D for such problems is expensive, and 1D planar models lack accuracy because they only allow the material to change in one dimension. Therefore, we propose dimensional emulation, which through a slight modification allows existing 1D planar geometry stochastic media radiation transport models to reproduce results from the equivalent 3D models by allowing the material to change in all three dimensions, reproducing the fidelity of the 3D model for the low computational cost of the 1D planar model. In this work, we apply dimensional emulation to three Monte Carlo stochastic media radiation transport models: Chord Length Sampling (CLS), the Local Realization Preserving method (LRP), and a variant of Conditional Point Sampling (CoPS). For a common Markovian benchmark set, the 3D emulation variants of these algorithms are numerically verified to reproduce the results of the 3D variants within statistics while running 1.3 to 2 times faster in the implementation within Sandia National Laboratories open-source research code PlaybookMC. The 3D emulation variants are also shown to yield a 72%–92% reduction in error for the thin slab problems in comparison to the 1D benchmark. As a result, the 3D emulation variant of CLS and CoPS-1 are shown to reproduce 3D CLS results that were used to approximate results for a 3D spherical inclusion geometry benchmark set.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure of AgI-doped Ge-In-S glasses: Experiment, reverse Monte Carlo modelling, and density functional calculations

We report an investigation of the structure and vibrational modes of Ge-In-S-AgI bulk glasses using X-ray diffraction, EXAFS spectroscopy, Reverse Monte-Carlo (RMC) modelling, Raman spectroscopy, and density functional theoretical (DFT) calculations. The combination of these techniques made it possible to elucidate the short- and medium-range structural order of these glasses. Data interpretation revealed that the AgI-free glass structure is composed of a network where GeS{sub 4/2} tetrahedra are linked with trigonal InS{sub 3/2} units; S{sub 3/2}Ge-GeS{sub 3/2} ethane-like species linked with InS{sub 4/2}{sup -} tetrahedra form sub-structures which are dispersed in the network structure. The addition of AgI into the Ge-In-S glassy matrix causes appreciable structural changes, enriching the Indium species with Iodine terminal atoms. The existence of trigonal species InS{sub 2/2}I and tetrahedral units InS{sub 3/2}I{sup -} and InS{sub 2/2}I{sub 2}{sup -} is compatible with the EXAFS and RMC analysis. Their vibrational properties (harmonic frequencies and Raman activities) calculated by DFT are in very good agreement with the experimental values determined by Raman spectroscopy. - Graphical abstract: Experiment (XRD, EXAFS, RMC, Raman scattering) and density functional calculations are employed to study the structure of AgI-doped Ge-In-S glasses. The role of mixed structural units as illustrated in the figure is elucidated. Highlights: Black-Right-Pointing-Pointer Doping Ge-In-S glasses with AgI causes significant changes in glass structure. Black-Right-Pointing-Pointer Experiment and DFT are combined to elucidate short- and medium-range structural order. Black-Right-Pointing-Pointer Indium atoms form both (InS{sub 4/2}){sup -} tetrahedra and InS{sub 3/2} planar triangles. Black-Right-Pointing-Pointer (InS{sub 4/2}){sup -} tetrahedra bond to (S{sub 3/2}Ge-GeS{sub 3/2}){sup 2+} ethane-like units forming neutral sub-structures. Black-Right-Pointing-Pointer Mixed chalcohalide species (InS{sub 3/2}I){sup -} offer vulnerable sites for the uptake of Ag{sup +}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of Se-Te glasses studied using neutron, X-ray diffraction and reverse Monte Carlo modelling

Pulsed neutron diffraction and synchrotron X-ray diffraction measurements were performed on Se{sub 100-x}Te{sub x} bulk glasses with x=10, 20, 30 and 40. The coordination numbers obtained from the diffraction results demonstrate that Se and Te atoms are twofold coordinated and the glass structure is formed by the chain network. The three-dimensional structure model for Se{sub 60}Te{sub 40} glass obtained by using reverse Monte Carlo modelling shows that the alternating arrangements of Se and Te atoms compose the major part of the chain clusters but several other fragments such as Se{sub n} chains and Te-Te dimers are also present in large numbers. The chain clusters have geometrically disordered forms and the interchain atomic order is different from those in the crystal structures of trigonal Se and trigonal Te. - Graphical abstract: Coordination environment in Se{sub 60}Te{sub 40} glass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stereology of backscatter electron images of etched surfaces for characterization of particle size distributions and volume fractions: Estimation of imaging bias via Monte Carlo simulations

On metallic specimens in which a secondary phase has been selectively removed by a chemical etchant, the use of backscatter electron (BSE) imaging yields images that are more readily segmented with image processing algorithms than other modes of imaging in the scanning electron microscope. The contrast mechanisms in this imaging mode, however, produce a bias in the observation of particle sizes and volume fractions due to the effects of the electron interaction volume in the specimen. This stereological bias is quantified using Monte Carlo (MC) simulation of backscatter images. It is observed that the overprojection of features with centroids residing beneath the plane of polish is largely canceled out by the reduced segmentation size of features with centroids residing above the plane of polish. - Research Highlights: {yields} Backscatter imaging of selectively-etched surfaces can facilitate segmentation. {yields} Backscatter imaging of voids is simulated to estimate imaging/observation biases. {yields} The biases are quantified and incorporated into the stereological calculation. {yields} Systematic errors and imaging biases are observed to counteract one another. {yields} Results are illustrated using a bimodal gamma prime distribution in a Ni superalloy.

36 MATERIALS SCIENCE↗

Comparison of three-dimensional morphologies of abnormally growing grains between Monte Carlo simulations and experiments of Fe-3% Si steel

Highlights: • Grains with sub-boundaries grew abnormally in the MC simulation with realistic grain boundary energy. • The experimental 3-D morphology of Goss grain was reconstructed from serially sectioned images. • 2-D sectioned microstructures of the MC simulation and experiment have highly irregular shape. • Both simulated and experimental 3-D morphologies of AGG have similar complicated shapes. - Abstract: Three-dimensional (3-D) Monte Carlo simulations of grain growth with sub-boundaries in the presence of precipitates were performed based on the distribution of realistic grain boundary energy data. The simulated grains with sub-boundaries grew abnormally. The simulated and experimental morphologies of the abnormally growing grains in Fe-3%Si steel were compared. The experimental 3-D morphology was reconstructed from serially sectioned images. Both the simulated and experimental 3-D morphologies of abnormally growing grains have highly irregular and complicated shapes whereas both the simulated and experimental 3-D morphologies of normally growing grains have relatively regular and simple shapes. Growth by wetting is responsible for the highly irregular shape of the experimental abnormally growing grains of Fe-3%Si steel as well as for the highly irregular shape of the simulated abnormally growing grains.

36 MATERIALS SCIENCE↗

A triple junction energy study using an inclination-dependent anisotropic Monte Carlo Potts grain growth model

This work presents a Monte Carlo Potts grain growth model in which the grain boundary (GB) energies depend on the GB inclination. The inclination is calculated using a linear smoothing approach developed by the authors. In bicrystal simulations with a shrinking grain, the grain changes shape to prefer low energy GB inclinations. However, in polycrystal simulations the preferred inclinations depend on the approach used to assign the triple junction (TJ) energies. Approaches that produce unimodal TJ energy distributions result in the expected behavior of preferring low energy GB inclinations. However, approaches that produce bimodal TJ energy distributions result in medium energy or even high energy inclinations being preferred. Overall, this study underscores the importance of TJs in anisotropic grain growth.

Grain boundary inclination↗

Dosimetry of a Small Air Cavity for Clinical Electron Beams: A Monte Carlo Study

This study investigated dosimetric changes in a water phantom when a small air cavity was presented at the central axis of a clinical electron beam. We used 6-, 9-, and 16-MeV electron beams with a 10 x 10 cm{sup 2} applicator and cutout produced by a Varian 21 EX linear accelerator. Percentage depth doses (PDDs) for different depths (0.5-7 cm), thicknesses (2-10 mm), and widths (1-5 cm) of air cavities were calculated using Monte Carlo simulations (EGSnrc code) validated by film measurements. By comparing PDDs of phantoms with and without the air cavity, it was found that when the depth or thickness of cavity was changed, the PDD curve below the cavity was shifted with a distance equal to the thickness of the cavity. However, when the width of the air cavity was changed, both the PDD curve and its slope within and below the cavity were changed. A larger width of the air cavity resulted in a shallower PDD curve within the cavity. The slope of the PDD curve below the cavity tended towards a value as the width of the air cavity was increased to 3-5 cm for the 6-, 9-, and 16-MeV electron beams. The dependence of the depth dose on the width of the air cavity is a result of the contribution of the electron side scattering in the water surrounding the cavity. The change in depth dose resulting from the presence of an air cavity can cause discrepancies between the calculated and actual dose during radiotherapy, unless the effects of the air cavity are properly characterized during treatment planning. From the dosimetry data in this study, neglecting an air cavity of 1-cm thickness in the build-up region of a 6-MeV electron beam resulted in a delivered dose 10-12% larger than the original prescription. Delivered doses 3% and 6% higher than the prescribed dose were observed when doses were prescribed at R{sub 80} for a 16-MeV electron beam. These results were obtained by neglecting air cavities with thicknesses equal to 2 and 4 mm, respectively, at a depth of 5 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dependences of mucosal dose on photon beams in head-and-neck intensity-modulated radiation therapy: a Monte Carlo study

Dependences of mucosal dose in the oral or nasal cavity on the beam energy, beam angle, multibeam configuration, and mucosal thickness were studied for small photon fields using Monte Carlo simulations (EGSnrc-based code), which were validated by measurements. Cylindrical mucosa phantoms (mucosal thickness = 1, 2, and 3 mm) with and without the bone and air inhomogeneities were irradiated by the 6- and 18-MV photon beams (field size = 1 Multiplication-Sign 1 cm{sup 2}) with gantry angles equal to 0 Degree-Sign , 90 Degree-Sign , and 180 Degree-Sign , and multibeam configurations using 2, 4, and 8 photon beams in different orientations around the phantom. Doses along the central beam axis in the mucosal tissue were calculated. The mucosal surface doses were found to decrease slightly (1% for the 6-MV photon beam and 3% for the 18-MV beam) with an increase of mucosal thickness from 1-3 mm, when the beam angle is 0 Degree-Sign . The variation of mucosal surface dose with its thickness became insignificant when the beam angle was changed to 180 Degree-Sign , but the dose at the bone-mucosa interface was found to increase (28% for the 6-MV photon beam and 20% for the 18-MV beam) with the mucosal thickness. For different multibeam configurations, the dependence of mucosal dose on its thickness became insignificant when the number of photon beams around the mucosal tissue was increased. The mucosal dose with bone was varied with the beam energy, beam angle, multibeam configuration and mucosal thickness for a small segmental photon field. These dosimetric variations are important to consider improving the treatment strategy, so the mucosal complications in head-and-neck intensity-modulated radiation therapy can be minimized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Differences in dose-volumetric data between the analytical anisotropic algorithm and the x-ray voxel Monte Carlo algorithm in stereotactic body radiation therapy for lung cancer

The objective of this study was to evaluate the differences in dose-volumetric data obtained using the analytical anisotropic algorithm (AAA) vs the x-ray voxel Monte Carlo (XVMC) algorithm for stereotactic body radiation therapy (SBRT) for lung cancer. Dose-volumetric data from 20 patients treated with SBRT for solitary lung cancer generated using the iPlan XVMC for the Novalis system consisting of a 6-MV linear accelerator and micro-multileaf collimators were recalculated with the AAA in Eclipse using the same monitor units and identical beam setup. The mean isocenter dose was 100.2% and 98.7% of the prescribed dose according to XVMC and AAA, respectively. Mean values of the maximal dose (D{sub max}), the minimal dose (D{sub min}), and dose received by 95% volume (D{sub 95}) for the planning target volume (PTV) with XVMC were 104.3%, 75.1%, and 86.2%, respectively. When recalculated with the AAA, those values were 100.8%, 77.1%, and 85.4%, respectively. Mean dose parameter values considered for the normal lung, namely the mean lung dose, V{sub 5}, and V{sub 20}, were 3.7 Gy, 19.4%, and 5.0% for XVMC and 3.6 Gy, 18.3%, and 4.7% for the AAA, respectively. All of these dose-volumetric differences between the 2 algorithms were within 5% of the prescribed dose. The effect of PTV size and tumor location, respectively, on the differences in dose parameters for the PTV between the AAA and XVMC was evaluated. A significant effect of the PTV on the difference in D{sub 95} between the AAA and XVMC was observed (p = 0.03). Differences in the marginal doses, namely D{sub min} and D{sub 95}, were statistically significant between peripherally and centrally located tumors (p = 0.04 and p = 0.02, respectively). Tumor location and volume might have an effect on the differences in dose-volumetric parameters. The differences between AAA and XVMC were considered to be within an acceptable range (<5 percentage points)

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film

This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5 mm to 1 cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 24%±13%. The dose difference between the MC simulation along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 22.1%±3%. For distances from 1.5 mm to 1 cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5 mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1 mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections

Early experience with stereotactic body radiation therapy (SBRT) of centrally located lung tumors indicated increased rate of high-grade toxicity in the lungs. These clinical results were based on treatment plans that were computed using pencil beam–like algorithms and without tissue inhomogeneity corrections. In this study, we evaluated the dosimetric errors in plans with and without inhomogeneity corrections and with planning target volumes (PTVs) that were within the zone of the proximal bronchial tree (BT). For 10 patients, the PTV, lungs, and sections of the BT either inside or within 2 cm of the PTV were delineated. Two treatment plans were generated for each patient using the following dose-calculation methods: (1) pencil beam (PB) algorithm without inhomogeneity correction (IC) (PB − IC) and (2) PB with inhomogeneity correction (PB + IC). Both plans had identical beam geometry but different beam segment shapes and monitor units (MU) to achieve similar conformal dose coverage of PTV. To obtain the baseline dose distributions, each plan was recalculated using a Monte Carlo (MC) algorithm by keeping MUs the same in the respective plans. The median maximum dose to the proximal BT and PTV dose coverage in the PB + IC plans were overestimated by 8% and 11%, respectively. However, the median maximum dose to the proximal BT and PTV dose coverage in PB − IC plans were underestimated by 15% and 9%. Similar trends were observed in low-dose regions of the lung within the irradiated volume. Our study indicates that dosimetric bias introduced by unit tissue density plans cannot be characterized as underestimation or overestimation of dose without taking the tumor location into account. This issue should be considered when analyzing clinical toxicity data from early lung SBRT trials that utilized unit tissue density for dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multileaf collimator tongue-and-groove effect on depth and off-axis doses: A comparison of treatment planning data with measurements and Monte Carlo calculations

To investigate how accurately treatment planning systems (TPSs) account for the tongue-and-groove (TG) effect, Monte Carlo (MC) simulations and radiochromic film (RCF) measurements were performed for comparison with TPS results. Two commercial TPSs computed the TG effect for Varian Millennium 120 multileaf collimator (MLC). The TG effect on off-axis dose profile at 3 depths of solid water was estimated as the maximum depth and the full width at half maximum (FWHM) of the dose dip at an interleaf position. When compared with the off-axis dose of open field, the maximum depth of the dose dip for MC and RCF ranged from 10.1% to 20.6%; the maximum depth of the dose dip gradually decreased by up to 8.7% with increasing depths of 1.5 to 10 cm and also by up to 4.1% with increasing off-axis distances of 0 to 13 cm. However, TPS results showed at most a 2.7% decrease for the same depth range and a negligible variation for the same off-axis distances. The FWHM of the dose dip was approximately 0.19 cm for MC and 0.17 cm for RCF, but 0.30 cm for Eclipse TPS and 0.45 cm for Pinnacle TPS. Accordingly, the integrated value of TG dose dip for TPS was larger than that for MC and RCF and almost invariant along the depths and off-axis distances. We concluded that the TG dependence on depth and off-axis doses shown in the MC and RCF results could not be appropriately modeled by the TPS versions in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗