Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Multi-modal chemical characterization of highly viscous submicrometer organic particles

Distinguishing highly viscous organic particles within complex mixtures of atmospheric aerosol and accurate descriptions of their composition, size distributions, and mixing states are challenges at the forefront of aerosol measurement science and technology. Here, we present results obtained from complementary single-particle measurement techniques employed for the in-depth characterization of highly viscous particles. In this study, we demonstrate advantages and synergy of this multi-modal particle characterization approach based on the analysis of individual viscous particles formed in the air-discharged waste produced by a common sewer pipe rehabilitation technology. Using oil immersion flow microscopy, we investigate particle size distributions and morphology of colloidal components present in field-collected aqueous waste condensates. We compare these results with corresponding measurements of viscous particles formed in drying droplets of the aerosolized discharged waste. The colloidal components and viscous particles were found to be approximately 10 µm and 0.5 µm, respectively. The aerosolized viscous particles exhibited a spherical morphology, while the colloidal particles appeared noticeably fractal, resembling fragments of a cured composite material. Chemical imaging of the viscous particles collected on substrates was performed using scanning electron microscopy and soft X-ray spectro-microscopy techniques. Through these methods, comprehensive description of these particles emerged, confirming their high solid-like viscosity, wide-ranging sizes, diverse carbon speciation with high degrees of oxygenation, and high organic volume fractions. The aerosolized viscous particles were further characterized using high-throughput single particle mass spectrometry. This technique provides real-time measurements of composition, size, and morphological metrics for large numbers of individual particles, enabling the identification of their distinct mass spectrometric signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating viscosity of individual substrate-deposited particles from measurements of their height-to-width ratios

Airborne particles alter the radiative forcing of climate and have further consequences on air visibility, atmospheric chemistry, and human health. Recent studies reported the existence of highly viscous semisolid and even solid amorphous organic aerosol (OA) particles. Particle viscosity has an impact on the heterogeneous chemistry, gas-particle partitioning, and ice nucleation properties. Consequently, variations in particle viscosity must be considered when predicting the atmospheric impact of OA. Here, in this work, we use scanning electron microscopy (SEM) and scanning transmission X-ray microscopy (STXM) to estimate the viscosity of individual particles deposited on substrates based on their characteristic height-to-width ratios, which are affected by changes in morphology upon deposition. The height-to-width ratios obtained from SEM and STXM exhibit a strong correlation, demonstrating that both imaging approaches can be applied separately for viscosity assessment of the substrate-deposited particles. While these metrics are largely qualitative, this method enables rapid assessment of particle viscosity ranges, distinguishing between semisolid (>10 10 Pa·s), viscous (10 4– 10 8 Pa·s), and liquid (10°–10 1 Pa·s) particles within ensembles of ambient particles collected for microscopy studies.

54 ENVIRONMENTAL SCIENCES↗

Improving Nb 3 Sn cavity performance using centrifugal barrel polishing

Abstract In this study we will show a new method of polishing for Nb 3 Sn cavities known as centrifugal barrel polishing (CBP). Using this method, Nb 3 Sn coated samples are polished to a surface roughness comparable to a traditional Nb cavity after electropolishing. We also investigate different methods of cleaning the Nb 3 Sn surface after CBP to remove residual abrasive particles. The polished Nb 3 Sn surface is analyzed using confocal laser microscopy, and scanning electron microscopy is used to image the surface and measure the surface roughness after polishing. Transmission electron microscopy is also used for high resolution analysis of the surface after polishing. Finally, we show that CBP can improve the performance of a Nb 3 Sn superconducting radiofrequency cavity.

43 PARTICLE ACCELERATORS↗

Twists and turns: stacking and structure-dependent optical response in MoS 2 nanoscrolls

Transition metal dichalcogenide (TMD) nanoscrolls (NSs), specifically MoS 2 NSs, present unique structural and optical properties, exhibiting prominent photoluminescence (PL) signals despite their multilayer nature. Here, this study investigates the structural and spectroscopic characteristics of MoS 2 NSs, correlating them to show the effects of reduced interlayer interactions on excitons of MoS 2 NSs. The reduction in interlayer interaction arises from two main factors: (1) symmetry-broken mixed stacking due to misalignment between layers and (2) a highly inhomogeneous strain profile generated by the Archimedean spiral geometry with positive eccentricity. Transmission electron microscopy, field emission scanning electron microscopy, atomic force microscopy, Raman spectroscopy, and second harmonic generation measurements confirm these findings. Low-temperature PL spectroscopy explores the impact of reduced interlayer interactions on exciton properties such as exciton–phonon coupling and oscillator strength. This study provides crucial insights into the structure, stacking and unique optical properties of TMD NSs, advancing the understanding of interlayer interactions and their impacts in complex quasi-one-dimensional nanostructures.

25 ENERGY STORAGE↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Neutral but Impactful: Gallium Cluster-Induced Nanopores from Beam-Blanked Gallium Ion Sources

Neutral atoms originating from liquid metal ion sources are an often-overlooked source of contamination and damage in focused ion beam microscopy. Beyond ions and single atoms, these sources also generate atom clusters. While most studies have investigated charged clusters, here we demonstrate that neutral clusters are also formed. These neutral clusters bypass the electrostatic beam blanking system, allowing them to impinge on samples even when the ion beam is blanked. We investigate this phenomenon using thin (≤20 nm) freestanding membranes of hexagonal boron nitride, silicon, and silicon nitride as targets. Randomly dispersed nanopores that form upon neutral cluster exposure are revealed. The average nanopore diameter is ∼2 nm with a narrow size distribution, suggesting that the atom clusters have a preferred size. Various electron microscopy techniques are used to characterize the nanopores, including high-resolution transmission electron microscopy, multislice ptychography, and electron energy-loss spectroscopy. Finally, we show how electron irradiation in the transmission electron microscope can be used to both remove any amorphous material that may clog the pores and to controllably grow the pores to specific sizes. Tunable nanopores such as these are interesting for nanofluidic applications requiring size-selective membranes.

Byrne, Dana O↗

A High-Speed Rotational Diamond Anvil Cell for In Situ Analysis of Hierarchical Microstructural Evolution of Metallic Alloys during Extreme Shear Deformation

High speed shear deformation is ubiquitous in engineering applications, ranging from material processing methods such as friction stir processing/extrusion and in tribological contacts. However, analyzing the microstructural evolution of materials while they are undergoing high speed shear deformation have been a long-standing challenge. This led to predominant reliance on ex situ microscopy before and after shear deformation. But ex situ microscopy lacks the ability to analyze dynamic and transient hierarchical microstructural evolution mechanisms that could occur during shear deformation of materials. Therefore, to better understand the dynamic mechanisms of mass and energy transfer in materials under shear deformation, we developed a first of its kind high-speed rotational diamond anvil cell (HS-RDAC) for synchrotron-based in situ high-energy x-ray diffraction (XRD). We studied the time resolved lattice strain evolution, XRD peak broadening and changes in spatial variation of shear deformation induced alloying in pure metal and metal alloy sheets and powder mixture using the HS-RDAC. These in situ results were combined with detailed ex situ microstructural characterization before and after the shear deformation using transmission electron microscopy and atom probe tomography, which revealed the different stages of evolution of a shear deformation induced hierarchical nanostructure. Multiscale computational simulations including computational fluid dynamics, crystal plasticity, molecular dynamic simulation and density functional theory uncovered the mechanisms behind morphological changes, evolution of defect structures and changes in driving force for shear deformation induced intermixing. In conclusion, this in situ HS-RDAC capability, in combination with ex situ microstructural characterization and computational simulations, can provide new insights into the hierarchical microstructural evolution pathway during shear deformation.

36 MATERIALS SCIENCE↗

Focused Interest Groups Propel Innovation in the Emerging Data-Driven Hardware Ecosystem

Over the past several decades, the science of electron microscopy (EM) has risen to become one of the cornerstone approaches to understanding material structure, chemistry, and defects at exceptional spatial resolution. This rise can be attributed to the hard work of researchers and companies who have pushed the bounds of instrumentation and analysis, but it is also the result of advocacy by members of professional societies. Furthermore, such advocacy is exemplified by the Aberration Corrected EM (ACEM) focused interest group (FIG) of the Microscopy Society of America (MSA), which has played an important role in facilitating new hardware developments, promoting the exchange of ideas to catalyze discovery, and building the next generation of leaders in electron microscopy. From the early 2000s to the present, aberration correction has moved from proof-of-concept instrumentation to an established technique, providing unprecedented improvements in spatial and chemical resolution for breakthroughs in chemistry, physics, and materials science.

47 OTHER INSTRUMENTATION↗

Electron- and light-induced stimulated Raman spectroscopy for nanoscale molecular mapping

We propose and theoretically analyze a new vibrational spectroscopy, termed electron- and light-induced stimulated Raman (ELISR) scattering, that combines the high spatial resolution of elec-tron microscopy with the molecular sensitivity of surface-enhanced Raman spectroscopy. WithELISR, electron-beam excitation of plasmonic nanoparticles is utilized as a spectrally-broadband butspatially-confined Stokes beam in the presence of a diffraction-limited pump laser. To characterizethis technique, we develop a numerical model and conduct full-field electromagnetic simulations toinvestigate two distinct nanoparticle geometries, nanorods and nanospheres, coated with a Raman-active material. Our results show the significant (10 6 -10 7 ) stimulated Raman enhancement that isachieved with dual electron and optical excitation of thesenanoparticle geometries. Importantly,the spatial resolution of this vibrational spectroscopy for electron microscopy is solely determinedby the nanoparticle geometry and the plasmon mode volume. Our results highlight the promiseof ELISR for simultaneous high-resolution electron microscopy with sub-diffraction-limited Ramanspectroscopy, complementing advances in superresolutionmicroscopy, correlated light and electronmicroscopy, and vibrational electron energy loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of organic electroactive crystallites in a dielectric matrix on the electrical properties of a polymer dielectric

In this work, the effects of inserting chargeable α-quaterthiophene (α4T) crystallites in polystyrene (PS) multilayers used as a transistor gate and capacitor dielectric were investigated. X-ray diffraction (XRD), scanning electron microscopy with energy dispersive x-ray spectroscopy (SEM/EDS), and confocal microscopy indicated the formation of α4T crystallites in the PS matrix. A modified saturation-regime current voltage relationship was used to estimate organic field-effect transistor (OFET) threshold voltage V TH shifting, and in turn the quantities of stored charge that were observed as a result of dielectric charging. The crystallites increased the maximum charge storage capacity as well as the charge retention capability of the dielectrics. Kelvin probe force microscopy (KPFM) showed that charges were localized near the α4T crystallites upon charging. Trilayer experiments validated the charge retention improvement of α4T crystallite-embedded PS dielectrics. The crystallites also improved breakdown characteristics in PS used as a capacitor dielectric, suggesting their application to storage capacitors in addition to OFET logic.

25 ENERGY STORAGE↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

SINGLE: Atomic-resolution structure identification of nanocrystals by graphene liquid cell EM

Analysis of the three-dimensional (3D) structures of nanocrystals with solution-phase transmission electron microscopy is beginning to reveal their unique physiochemical properties. We developed a “one-particle Brownian 3D reconstruction method” based on imaging of ensembles of colloidal nanocrystals using graphene liquid cell electron microscopy. Projection images of differently rotated nanocrystals are acquired using a direct electron detector with high temporal (<2.5 ms) resolution and analyzed to obtain an ensemble of 3D reconstructions. Here, we introduce computational methods required for successful atomic-resolution 3D reconstruction: (i) tracking of the individual particles throughout the time series, (ii) subtraction of the interfering background of the graphene liquid cell, (iii) identification and rejection of low-quality images, and (iv) tailored strategies for 2D/3D alignment and averaging that differ from those used in biological cryo–electron microscopy. Our developments are made available through the open-source software package SINGLE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Changes in supramolecular organization of cyanobacterial thylakoid membrane complexes in response to far-red light photoacclimation

Cyanobacteria are ubiquitous in nature and have developed numerous strategies that allow them to live in a diverse range of environments. Certain cyanobacteria synthesize chlorophylls d and f to acclimate to niches enriched in far-red light (FRL) and incorporate paralogous photosynthetic proteins into their photosynthetic apparatus in a process called FRL-induced photoacclimation (FaRLiP). We characterized the macromolecular changes involved in FRL-driven photosynthesis and used atomic force microscopy to examine the supramolecular organization of photosystem I associated with FaRLiP in three cyanobacterial species. Mass spectrometry showed the changes in the proteome of Chroococcidiopsis thermalis PCC 7203 that accompany FaRLiP. Fluorescence lifetime imaging microscopy and electron microscopy reveal an altered cellular distribution of photosystem complexes and illustrate the cell-to-cell variability of the FaRLiP response.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization, comparison, and optimization of lattice light sheets

Lattice light sheet microscopy excels at the noninvasive imaging of three-dimensional (3D) dynamic processes at high spatiotemporal resolution within cells and developing embryos. Recently, several papers have called into question the performance of lattice light sheets relative to the Gaussian sheets most common in light sheet microscopy. Here, we undertake a theoretical and experimental analysis of various forms of light sheet microscopy, which demonstrates and explains why lattice light sheets provide substantial improvements in resolution and photobleaching reduction. The analysis provides a procedure to select the correct light sheet for a desired experiment and specifies the processing that maximizes the use of all fluorescence generated within the light sheet excitation envelope for optimal resolution while minimizing image artifacts and photodamage. We also introduce a new type of “harmonic balanced” lattice light sheet that improves performance at all spatial frequencies within its 3D resolution limits and maintains this performance over lengthened propagation distances allowing for expanded fields of view.

59 BASIC BIOLOGICAL SCIENCES↗

Scalable bottom-up synthesis of Co-Ni–doped graphene

Introducing heteroatoms into graphene is a powerful strategy to modulate its catalytic, electronic, and magnetic properties. At variance with the cases of nitrogen (N)– and boron (B)–doped graphene, a scalable method for incorporating transition metal atoms in the carbon (C) mesh is currently lacking, limiting the applicative interest of model system studies. This work presents a during-growth synthesis enabling the incorporation of cobalt (Co) alongside nickel (Ni) atoms in graphene on a Ni(111) substrate. Single atoms are covalently stabilized within graphene double vacancies, with a Co load ranging from 0.07 to 0.22% relative to C atoms, controllable by synthesis parameters. Structural characterization involves variable-temperature scanning tunneling microscopy and ab initio calculations. The Co- and Ni-codoped layer is transferred onto a transmission electron microscopy grid, confirming stability through scanning transmission electron microscopy and electron energy loss spectroscopy. This method holds promise for applications in spintronics, gas sensing, electrochemistry and catalysis, and potential extension to graphene incorporation of similar metals.

Science & Technology - Other Topics↗

Evaluation of Immunocompetent Mouse Models for Borrelia miyamotoi Infection

Borrelia miyamotoi is a relapsing fever spirochete that is harbored by Ixodes spp. ticks and is virtually uncharacterized, compared to other relapsing fever Borrelia vectored by Ornithodoros spp. ticks. There is not an immunocompetent mouse model for studying B. miyamotoi infection in vivo or for transmission in the vector-host cycle. Our goal was to evaluate B. miyamotoi infections in multiple mouse breeds/strains as a prelude to the ascertainment of the best experimental infection model. Two B. miyamotoi strains, namely, LB-2001 and CT13-2396, as well as three mouse models, namely, CD-1, C3H/HeJ, and BALB/c, were evaluated. We were unable to observe B. miyamotoi LB-2001 spirochetes in the blood via darkfield microscopy or to detect DNA via real-time PCR post needle inoculation in the CD-1 and C3H/HeJ mice. However, LB-2001 DNA was detected via real-time PCR in the blood of the BALB/c mice after needle inoculation, although spirochetes were not observed via microscopy. CD-1, C3H/HeJ, and BALB/c mice generated an antibody response to B. miyamotoi LB-2001 following needle inoculation, but established infections were not detected, and the I. scapularis larvae failed to acquire spirochetes from the exposed CD-1 mice. In contrast, B. miyamotoi CT13-2396 was visualized in the blood of the CD-1 and C3H/HeJ mice via darkfield microscopy and detected by real-time PCR post needle inoculation. Both mouse strains seroconverted. However, no established infection was detected in the mouse organs, and the I. scapularis larvae failed to acquire Borrelia after feeding on CT13-2396 exposed CD-1 or C3H/HeJ mice. Furthermore, these findings underscore the challenges in establishing an experimental B. miyamotoi infection model in immunocompetent laboratory mice.

60 APPLIED LIFE SCIENCES↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗