Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Evaluation of magnetic field error in ExtendedEBIS

The upgrade of the EBIS, called ExtendedEBIS, is now in progress in Brookhaven National Laboratory. Two 5T-superconducting solenoids have been placed in series with 200 mm distance from each other for higher trap capacity and production of polarized 3He ions. Since the two superconducting solenoids are used, the field error is expected to be larger. In this research, the field error is estimated based on simulation. It was found that the magnetic field line can be 17 mm off from the center axis at the entrance of the collector, and this offset can be adjusted by three types of correction coils. Additionally, mismatch of the spin direction of polarized 3He due to the misalignment was estimated to be small.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Status of Long Coil Production for the MQXFB Nb3Sn Prototype Quadrupole for the HiLumi LHC

The High luminosity LHC upgrade target is to increase the integrated luminosity by a factor 10, resulting in an integrated luminosity of 3000 fb-1. One major improvement foreseen is the reduction of the beam size at the collision points. This requires the development of 150 mm single aperture quadrupoles for the interaction regions. These quadrupoles are under development in a joint collaboration between CERN and the US-LHC Accelerator Research Program (LARP). The chosen approach for achieving a nominal quadrupole field gradient of 132.6 T/m is based on the Nb3Sn technology. The coils with a length of 7281 mm will be the longest Nb3Sn coils fabricated so far for accelerator magnets. The production of the long coils was launched in 2016 based on practise coils made from copper. This paper provides a status of the production of the first low grade and full performance coils and describes the production process and applied quality control. Furthermore an outlook for the prototype assembly is provided.

43 PARTICLE ACCELERATORS↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Auto-magnetizing (AutoMag) liners for MagLIF: Helically-wound composite liners.

Magnetized Liner Inertial Fusion (MagLIF) is an inertial confinement fusion (ICF) concept that includes a strong magnetic field embedded in the fuel to mitigate thermal conduction loss during the implosion. MagLIF experiments on Sandia's 20 MA Z Machine uses an external Helmholtz-like coil pair for fuel premagnetization. By contrast, the novel AutoMag concept employs a composite liner (cylindrical tube) with helically oriented conduction paths separated by insulating material to provide axial premagnetization of the fuel. Initially, during a current prepulse that slowly rises to %7E1 MA, current flows helically through the AutoMag liner, and sources the fuel with an axial field. Next, a rapidly rising main current pulse breaks down the insulation and current in the liner becomes purely axial. The liner and premagnetized fuel are then compressed by the rapidly growing azimuthal field external to the liner. This integrated axial-field-production mechanism offers a few potential advantages when compared to the external premagnetization coils. AutoMag can increase drive current to MagLIF experiments by enabling a lower inductance transmission line, provide higher premagnetization field (>30 T), and greatly increase radial x-ray diagnostic access. 3D electromagnetic simulations using ANSYS Maxwell have been completed in order to explore the current distributions within the helical conduction paths, the inter - wire dielectric strength properties, and the thermal properties of the helical conduction paths during premagnetization (%7E1 MA in 100ns). Three liner designs, of varying peak field strength, and associated varying risk of dielectric breakdown, will soon be tested in experiments on the %7E 1 MA, 100ns Mykonos facility. Experiments will measure B z (t) inside of the line r and assess failure mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A remotely interrogatable sensor for chemical monitoring

A new type of continuously operating, in-situ, remotely monitored sensor is presented. The sensor is comprised of a thin film array of magnetostatically coupled, magnetically soft ferromagnetic thin film structures, adhered to or encased within a thin polymer layer. The polymer is made so that it swells or shrinks in response to the chemical analyte of interest, which in this case is pH. As the polymer swells or shrinks, the magnetostatic coupling between the magnetic elements changes, resulting in changes in the magnetic switching characteristics of the sensor. Placed within a sinusoidal magnetic field the magnetization vector of the coupled sensor elements periodically reverses directions, generating magnetic flux that can be remotely detected as a series of voltage spikes in appropriately placed pickup coils. one preliminary sensor design consists of four triangles, initially spaced approximately 50 micrometers apart, arranged to form a 12 mm x 12 mm square with the triangle tips centered at a common origin. Our preliminary work has focused on monitoring of pH using a lightly crosslinked pH sensitive polymer layer of hydroxyethylmethacrylate and 2-(dimethylamino) ethylmethacrylate. As the polymer swells or shrinks the magnetostatic coupling between the triangles changes, resulting in measurable changes in the amplitude of the detected voltage spirits.

Non-NASA Center↗

Conductor Properties and Coil Technology for a Bi2212 Dipole Insert for 20 Tesla Hybrid Accelerator Magnets

A dipole insert based on a 2-layer cos-theta coil with stress management and Bi2212 superconducting strand and cable is being developed at Fermilab as part of the US-MDP effort. The ultimate goal of this task is to develop coil technology and an approach to manage azimuthal and radial strains of high temperature superconductor inserts when integrated within Nb3Sn outserts as a hybrid magnet system. This note reviews conductor properties and possible coil technologies.

43 PARTICLE ACCELERATORS↗

Heat diffusion across magnetic islands and ergodized plasma regions in realistic tokamak geometry

Heat diffusion in magnetized plasmas is investigated numerically for tokamak geometry and realistic plasma parameters. Heat transport across single and overlapping magnetic islands is studied. As an application, the influence of an (n+1,m+1) helical perturbation onto the temperature perturbation caused by an (n,m) neoclassical tearing mode is examined. It is shown that the resulting ergodization of the magnetic field structure is able to reduce the resonant bootstrap current perturbation of a neoclassical tearing mode. This might explain the drop in the mode amplitude observed in the frequently interrupted regime. Furthermore, the influence of edge ergodization as generated by external perturbation coils onto the electron temperature is studied. It is shown that ergodization of the plasma boundary can decrease the pedestal temperature gradient significantly. This effect might be one element in the mitigation effects of edge-localized modes achieved by external resonant perturbation fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of resonant magnetic perturbations on three dimensional equilibria in the Madison Symmetric Torus reversed-field pinch

The orientation of 3D equilibria in the Madison Symmetric Torus (MST) [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)] reversed-field pinch can now be controlled with a resonant magnetic perturbation (RMP). Absent the RMP, the orientation of the stationary 3D equilibrium varies from shot to shot in a semi-random manner, making its diagnosis difficult. Produced with a poloidal array of saddle coils at the vertical insulated cut in MST's thick conducting shell, an m = 1 RMP with an amplitude b{sub r}/B ∼ 10% forces the 3D structure into any desired orientation relative to MST's diagnostics. This control has led to improved diagnosis, revealing enhancements in both the central electron temperature and density. With sufficient amplitude, the RMP also inhibits the generation of high-energy (>20 keV) electrons, which otherwise emerge due to a reduction in magnetic stochasticity in the core. Field line tracing reveals that the RMP reintroduces stochasticity to the core. A m = 3 RMP of similar amplitude has little effect on the magnetic topology or the high-energy electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Identification of the plasma boundary shape and position in the Damavand tokamak

A series of experiments and numerical calculations have been done on the Damavand tokamak for accurate determination of equilibrium parameters, such as the plasma boundary position and shape. For this work, the pickup coils of the Damavand tokamak were recalibrated and after that a plasma boundary shape identification code was developed for analyzing the experimental data, such as magnetic probes and coils currents data. The plasma boundary position, shape and other parameters are determined by the plasma shape identification code. A free-boundary equilibrium code was also generated for comparison with the plasma boundary shape identification results and determination of required fields to obtain elongated plasma in the Damavand tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Modeling of Macroscopic Plasma Dynamics Final Scientific Report May 1, 2006 – April 30, 2018

The project entitled, "Nonlinear Modeling of Macroscopic Plasma Dynamics," applied numerical computation to solve mathematical models of plasma behavior in laboratory systems. Plasma is the state of matter with sufficiently large internal energy density such that electrons dissociate from atoms to form gas of electrically charged particles. It occurs naturally in stars, planetary magnetospheres, and interstellar and intergalactic media. It is also used for industrial purposes and in lighting. Fusion energy science seeks to create and sustain plasma conditions where atomic nuclei fuse to create energy that can be captured for power production. Many laboratory experiments for this effort use magnetic field to contain plasma and to thermally insulate it from its surroundings. Possible plasma dynamics in magnetized systems include collective behavior over spatial scales that are comparable to the configuration size, and these dynamics often include evolution of the magnetic field that is used for confinement. Solving the mathematical models that describe these dynamics in specific experiments often requires computer simulations, as done in this project. This project analyzed plasma magnetic relaxation dynamics in the laboratory configurations known as the reversed-field pinch (RFP), the spheromak, and the spherical torus (ST). It also developed capabilities for modeling disruptive plasma dynamics in the tokamak, which has achieved the highest performance for magnetized plasma and is the design of the large international ITER experiment (https://www.iter.org) that is under construction and is expected to be the first to achieve self-heating conditions. Dynamic evolution to states of low energy, the aforementioned magnetic relaxation, is known to be important for generating the RFP and spheromak configurations. Nonlinear computational modeling with the Non-Ideal Magnetohydrodynamics with Rotation, Open Discussion code (NIMROD, https://nimrodteam.org) was applied to understand specific aspects of magnetic relaxation in RFPs, spheromaks, and STs. The RFP study considered how the nonlinear transfer of power among different fluctuation harmonics is altered due to the application of pulses of electric field, as done experimentally in the Madison Symmetric Torus RFP device at the University of Wisconsin-Madison. It also investigated the separation of electron and ion dynamics, known as two-fluid effects, including effects on the evolution of the plasma flow profile. The spheromak study considered the influence of these two-fluid effects in conditions relevant to the Sustained Spheromak Experiment (SSPX), formerly at Lawrence Livermore National Laboratory. Our study found that two-fluid effects enhance stability with respect to interchange in SSPX-relevant conditions, but having a complete model with two-fluid effects in separate electron and ion temperature equations is important. The study for STs focused on plasma startup in the Pegasus Toroidal Experiment at UW-Madison, which uses DC voltage applied through a small plasma gun. The simulations show how the resulting helical current stream relaxes through repetitive merging, forming current rings that accumulate into a tokamak-like configuration. Analytical theory was also developed to help explain behavior that was observed in the RFP and spheromak computations. Although the tokamak configuration has outperformed other magnetic confinement configurations, it has a tendency to undergo discharge-terminating dynamics that release energy onto plasma-facing surfaces and exert electromechanical forces on magnetic coils and structures. Our efforts have improved NIMROD's capabilities to model tokamak disruption by incorporating a resistive wall model that can be applied to axisymmetric, as well as asymmetric, distortions of the magnetic field configuration. Computations addressed whether mathematical conditions applied to plasma flow at the wall influence disruptive dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements and correction of the 1/1 error field in Wendelstein 7-X

In this paper, vacuum flux surface mapping is used to measure the error field in Wendelstein 7-X. Two methods for discriminating the perturbation from other co-resonant modes are applied: measurements of the helical axis shift in a magnetic configuration with the rotational transform barely above one on the axis; and measurements of the edge island structure with cancellation of intrinsic islands by divertor control coils. The normalized radial amplitude in Boozer coordinates is found to be about in the first case and about in the second one, with the discrepancy being attributable to different currents in the planar coils. The error field can be reliably compensated by using error field trim coils with currents about 100 A. Here, this compensation also helps to identify the error field of about . During plasma operation in divertor configurations, it is confirmed that the present field leads to asymmetries in the power distribution and that the compensation improves this symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-H-BRA-06: Characterization of a Linear Accelerator Operating in a Compact MRIGuided Radiation Therapy System

Purpose: To describe the performance of a linear accelerator operating in a compact MRI-guided radiation therapy system. Methods: A commercial linear accelerator was placed in an MRI unit that is employed in a commercial MR-based image guided radiation therapy (IGRT) system. The linear accelerator components were placed within magnetic field-reducing hardware that provided magnetic fields of less than 40 G for the magnetron, gun driver, and port circulator, with 1 G for the linear accelerator. The system did not employ a flattening filter. The test linear accelerator was an industrial 4 MV model that was employed to test the ability to run an accelerator in the MR environment. An MR-compatible diode detector array was used to measure the beam profiles with the accelerator outside and inside the MR field and with the gradient coils on and off to examine if there was any effect on the delivered dose distribution. The beam profiles and time characteristics of the beam were measured. Results: The beam profiles exhibited characteristic unflattened Bremsstrahlung features with less than ±1.5% differences in the profile magnitude when the system was outside and inside the magnet and less than 1% differences with the gradient coils on and off. The central axis dose rate fluctuated by less than 1% over a 30 second period when outside and inside the MRI. Conclusion: A linaccompatible MR design has been shown to be effective in not perturbing the operation of a commercial linear accelerator. While the accelerator used in the tests was 4MV, there is nothing fundamentally different with the operation of a 6MV unit, implying that the design will enable operation of the proposed clinical unit. Research funding provided by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

43 PARTICLE ACCELERATORS↗

Particle-in-cell simulations of magnetically driven reconnection using laser-powered capacitor coils

In this study, we propose an experimental scheme to fulfill magnetically driven reconnections. Here, two laser beams are focused on a capacitor-coil target and then strong currents are wired in two parallel circular coils. Magnetic reconnection occurs between the two magnetic bubbles created by the currents in the two parallel circular coils. A two-dimensional particle-in-cell simulation model in the cylindrical coordinate is used to investigate such a process, and the simulations are performed in the ( r , z ) plane. The results show that with the increase of the currents in the two coils, the associated magnetic bubbles expand and a current sheet is formed between the two bubbles. Magnetic reconnection occurs when the current sheet is sufficiently thin. A quadrupole structure of the magnetic field in the θ direction ( B θ ) is generated in the diffusion region and a strong electron current along the r direction ( J e r ) is also formed due to the existence of the high-speed electron flow away from the X line in the center of the outflow region. Finally, because the X line is a circle along the θ direction, the convergence of the plasma flow around r = 0 will lead to the asymmetry of J e r and B θ between the two outflow regions of magnetic reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗