Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Building Commissioning: A Golden Opportunity for Reducing Energy Costs and Greenhouse-gas Emissions

The aim of commissioning new buildings is to ensure that they deliver, if not exceed, the performance and energy savings promised by their design. When applied to existing buildings, commissioning identifies the almost inevitable 'drift' from where things should be and puts the building back on course. In both contexts, commissioning is a systematic, forensic approach to quality assurance, rather than a technology per se. Although commissioning has earned increased recognition in recent years - even a toehold in Wikipedia - it remains an enigmatic practice whose visibility severely lags its potential. Over the past decade, Lawrence Berkeley National Laboratory has built the world's largest compilation and meta-analysis of commissioning experience in commercial buildings. Since our last report (Mills et al. 2004) the database has grown from 224 to 643 buildings (all located in the United States, and spanning 26 states), from 30 to 100 million square feet of floorspace, and from $17 million to $43 million in commissioning expenditures. The recorded cases of new-construction commissioning took place in buildings representing $2.2 billion in total construction costs (up from 1.5 billion). The work of many more commissioning providers (18 versus 37) is represented in this study, as is more evidence of energy and peak-power savings as well as cost-effectiveness. We now translate these impacts into avoided greenhouse gases and provide new indicators of cost-effectiveness. We also draw attention to the specific challenges and opportunities for high-tech facilities such as labs, cleanrooms, data centers, and healthcare facilities. The results are compelling. We developed an array of benchmarks for characterizing project performance and cost-effectiveness. The median normalized cost to deliver commissioning was $0.30/ft2 for existing buildings and $1.16/ft2 for new construction (or 0.4% of the overall construction cost). The commissioning projects for which data are available revealed over 10,000 energy-related problems, resulting in 16% median whole-building energy savings in existing buildings and 13% in new construction, with payback time of 1.1 years and 4.2 years, respectively. In terms of other cost-benefit indicators, median benefit-cost ratios of 4.5 and 1.1, and cash-on-cash returns of 91% and 23% were attained for existing and new buildings, respectively. High-tech buildings were particularly cost-effective, and saved higher amounts of energy due to their energy-intensiveness. Projects with a comprehensive approach to commissioning attained nearly twice the overall median level of savings and five-times the savings of the least-thorough projects. It is noteworthy that virtually all existing building projects were cost-effective by each metric (0.4 years for the upper quartile and 2.4 years for the lower quartile), as were the majority of new-construction projects (1.5 years and 10.8 years, respectively). We also found high cost-effectiveness for each specific measure for which we have data. Contrary to a common perception, cost-effectiveness is often achieved even in smaller buildings. Thanks to energy savings valued more than the cost of the commissioning process, associated reductions in greenhouse gas emissions come at 'negative' cost. In fact, the median cost of conserved carbon is negative - -$110 per tonne for existing buildings and -$25/tonne for new construction - as compared with market prices for carbon trading and offsets in the +$10 to +$30/tonne range. Further enhancing the value of commissioning, its non-energy benefits surpass those of most other energy-management practices. Significant first-cost savings (e.g., through right-sizing of heating and cooling equipment) routinely offset at least a portion of commissioning costs - fully in some cases. When accounting for these benefits, the net median commissioning project cost was reduced by 49% on average, while in many cases they exceeded the direct value of the energy savings. Commissioning also improves worker comfort, mitigates indoor air quality problems, increases the competence of in-house staff, plus a host of other non-energy benefits. These findings demonstrate that commissioning is arguably the single-most cost-effective strategy for reducing energy, costs, and greenhouse gas emissions in buildings today. Energy savings tend to persist well over at least a 3- to 5-year timeframe, but data over longer time horizons are not available. It is thus important to 'Trust but Verify,' and indeed the field is moving towards a monitoring-based paradigm in which instrumentation is used not only to confirm savings, but to identify opportunities that would otherwise go undetected. On balance, we view the findings here as conservative, in the sense that they underestimate the actual performance of projects when all costs and benefits are considered. They underestimate the technical potential for a scenario in which best practices are applied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The exometabolome of Clostridium thermocellum reveals overflow metabolism at high cellulose loading

Background: Clostridium thermocellum is a model thermophilic organism for the production of biofuels from lignocellulosic substrates. The majority of publications studying the physiology of this organism use substrate concentrations of ≤10 g/L. However, industrially relevant concentrations of substrate start at 100 g/L carbohydrate, which corresponds to approximately 150 g/L solids. To gain insight into the physiology of fermentation of high substrate concentrations, we studied the growth on, and utilization of high concentrations of crystalline cellulose varying from 50 to 100 g/L by C. thermocellum. Results: Using a defined medium, batch cultures of C. thermocellum achieved 93% conversion of cellulose (Avicel) initially present at 100 g/L. The maximum rate of substrate utilization increased with increasing substrate loading. During fermentation of 100 g/L cellulose, growth ceased when about half of the substrate had been solubilized. However, fermentation continued in an uncoupled mode until substrate utilization was almost complete. In addition to commonly reported fermentation products, amino acids - predominantly L-valine and L-alanine - were secreted at concentrations up to 7.5 g/L. Uncoupled metabolism was also accompanied by products not documented previously for C. thermocellum, including isobutanol, meso- and RR/SS-2,3-butanediol and trace amounts of 3-methyl-1-butanol, 2-methyl-1-butanol and 1-propanol. We hypothesize that C. thermocellum uses overflow metabolism to balance its metabolism around the pyruvate node in glycolysis. In conclusion: C. thermocellum is able to utilize industrially relevant concentrations of cellulose, up to 93 g/L. We report here one of the highest degrees of crystalline cellulose utilization observed thus far for a pure culture of C. thermocellum, the highest maximum substrate utilization rate and the highest amount of isobutanol produced by a wild-type organism.

Fusel alcohols↗

Measuring the energy flux at the substrate position during magnetron sputter deposition processes

In this work, the energetic conditions at the substrate were investigated in dc magnetron sputtering (DCMS), pulsed dc magnetron sputtering (pDCMS), and high power impulse magnetron sputtering (HiPIMS) discharges by means of an energy flux diagnostic based on a thermopile sensor, the probe being set at the substrate position. Measurements were performed in front of a titanium target for a highly unbalanced magnetic field configuration. The average power was always kept to 400 W and the probe was at the floating potential. Variation of the energy flux against the pulse peak power in HiPIMS was first investigated. It was demonstrated that the energy per deposited titanium atom is the highest for short pulses (5 {mu}s) high pulse peak power (39 kW), as in this case, the ion production is efficient and the deposition rate is reduced by self-sputtering. As the argon pressure is increased, the energy deposition is reduced as the probability of scattering in the gas phase is increased. In the case of the HiPIMS discharge run at moderate peak power density (10 kW), the energy per deposited atom was found to be lower than the one measured for DCMS and pDCMS discharges. In these conditions, the HiPIMS discharge could be characterized as soft and close to a pulsed DCMS discharge run at very low duty cycle. For the sake of comparison, measurements were also carried out in DCMS mode with a balanced magnetron cathode, in the same working conditions of pressure and power. The energy flux at the substrate is significantly increased as the discharge is generated in an unbalanced field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solar Plus: A Holistic Approach to Distributed Solar PV

Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

14 SOLAR ENERGY↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upper troposphere dust belt formation processes vary seasonally and spatially in the Northern Hemisphere

Dust aerosols impact global energy balance substantially by acting as efficient ice nuclei to alter cold cloud properties. However, the estimate of dust indirect effect remains uncertain due to simulating dust distributions poorly and lacking reliable dust observations, especially in the upper-troposphere. Here, we characterize and understand upper-troposphere dust sources and transport with an improved dust dataset derived from A-train satellite lidar and radar measurements and an air parcel trajectory model. The distinct upper-troposphere dust belt over the northern hemisphere has seasonally varying base and top heights of 3.65 ± 2.84 and 8.35 ± 1.50 km above mean sea level and its column loading is strongest during spring (March-April-May). The out-of-phase annual cycles of mid-level dust concentration and westerly wind over source regions control the seasonal upper-tropospheric dust loading variations. African deserts contribute the most (46.3%) to the upper-troposphere dust belt in spring and the synoptic trough is the leading (49%) dust lifting mechanism.

54 ENVIRONMENTAL SCIENCES↗

Effects of Material Selection on the Remanufacturability of a Swashplate in an Axial Piston Pump

A swashplate is a critical component in an axial piston pump for motion transformation that undergoes cyclic loading. Traditionally, swashplates are not designed to have multiple lives of operation. According to industry experts, a remanufacturability analysis of swashplates suggests that the scrap rate is high. Among the primary reasons for this high scrap rate is insufficient material on the running surface, especially for subtractive recovery. Therefore, the selection of the proper material and its amount plays a significant role in the fatigue behavior, the remanufacturability of the swashplate, as well as its cost. Analyses addressing fatigue life, remanufacturability, and cost of the swashplate were carried out in this paper through a comparative study utilizing various materials. Recommendations on the material selection that balance the failure consequences, remanufacturability, and cost are provided to guide designers in making informed decisions for alternative design options.

42 ENGINEERING↗

Dynamics stabilization and transport coherency in a rocking ratchet for cold atoms

Cold atoms in optical lattices have emerged as an ideal system to investigate the ratchet effect, as demonstrated by several recent experiments. In this work we analyze theoretically two aspects of ac-driven transport in cold-atom ratchets. We first address the issue of whether, and to what extent, an ac-driven ratchet for cold atoms can operate as a motor. We thus study theoretically a dissipative motor for cold atoms, as obtained by adding a load to a 1D nonadiabatically driven rocking ratchet. We demonstrate that a current can be generated also in the presence of a load, e.g., the ratchet device can operate as a motor. Correspondingly, we determine the stall force for the motor, which characterizes the range of loads over which the device can operate as a motor, and the differential mobility, which characterizes the response to a change in the magnitude of the load. Second, we compare our results for the transport in an ac-driven ratchet device with the transport in a dc-driven system. We observe a peculiar phenomenon: the double-harmonic ac force stabilizes the dynamics, allowing the generation of uniform directed motion over a range of momentum much larger than what is possible with a dc bias. We explain such a stabilization of the dynamics by observing that a nonadiabatic ac drive broadens the effective cooling momentum range and forces the atom trajectories to cover such a region. Thus the system can dissipate energy and maintain a steady-state energy balance. Our results show that in the case of a finite-range velocity-dependent friction, a ratchet device may offer the possibility of controlling the particle motion over a broader range of momentum with respect to a purely biased system, although this is at the cost of a reduced coherency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Design for Hanford Low-Activity Waste Glasses with High Waste Loading

This report discusses the development of an experimental design for the initial phase of the Hanford low-activity waste (LAW) enhanced glass study. This report is based on a manuscript written for an applied statistics journal. Appendices A, B, and E include additional information relevant to the LAW enhanced glass experimental design that is not included in the journal manuscript. The glass composition experimental region is defined by single-component constraints (SCCs), linear multiple-component constraints (MCCs), and a nonlinear MCC involving 15 LAW glass components. Traditional methods and software for designing constrained mixture experiments with SCCs and linear MCCs are not directly applicable because of the nonlinear MCC. A modification of existing methodology to account for the nonlinear MCC was developed and is described in this report. One of the glass components, SO 3 , has a solubility limit in glass that depends on the composition of the balance of the glass. A goal was to design the experiment so that SO 3 would not exceed its predicted solubility limit for any of the experimental glasses. The SO 3 solubility limit had previously been modeled by a partial quadratic mixture model expressed in the relative proportions of the 14 other components. The partial quadratic mixture model was used to construct a nonlinear MCC in terms of all 15 components. In addition, there were SCCs and linear MCCs. This report describes how a layered design was generated to (i) account for the SCCs, linear MCCs, and nonlinear MCC and (ii) meet the goals of the study. A layered design consists of points on an outer layer, and inner layer, and a center point. There were 18 outer-layer glasses chosen using optimal experimental design software to augment 147 existing glass compositions that were within the LAW glass composition experimental region. Then 13 inner-layer glasses were chosen with the software to augment the existing and outer-layer glasses. The experimental design was completed by a center-point glass, a Vitreous State Laboratory glass, and replicates of the center point and Vitreous State Laboratory glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multivariable Robust Control of a Simulated Hybrid Solid Oxide Fuel Cell Gas Turbine Plant

This work presents a systematic approach to the multivariable robust control of a hybrid fuel cell gas turbine plant. The hybrid configuration under investigation built by the National Energy Technology Laboratory comprises a physical simulation of a 300kW fuel cell coupled to a 120kW auxiliary power unit single spool gas turbine. The public facility provides for the testing and simulation of different fuel cell models that in turn help identify the key difficulties encountered in the transient operation of such systems. An empirical model of the built facility comprising a simulated fuel cell cathode volume and balance of plant components is derived via frequency response data. Through the modulation of various airflow bypass valves within the hybrid configuration, Bode plots are used to derive key input/output interactions in transfer function format. A multivariate system is then built from individual transfer functions, creating a matrix that serves as the nominal plant in an H{sub {infinity}} robust control algorithm. The controller’s main objective is to track and maintain hybrid operational constraints in the fuel cell’s cathode airflow, and the turbo machinery states of temperature and speed, under transient disturbances. This algorithm is then tested on a Simulink/MatLab platform for various perturbations of load and fuel cell heat effluence. As a complementary tool to the aforementioned empirical plant, a nonlinear analytical model faithful to the existing process and instrumentation arrangement is evaluated and designed in the Simulink environment. This parallel task intends to serve as a building block to scalable hybrid configurations that might require a more detailed nonlinear representation for a wide variety of controller schemes and hardware implementations.

30 DIRECT ENERGY CONVERSION↗

Revenue Opportunities through Ancillary Services for Nuclear Power Plants with Integrated Firebrick Resistance- Heated Energy Storage (FIRES)

Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreement end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services and increase revenue. This transaction summarizes the opportunities provided by participation in ancillary services markets potentially made possible by integration of thermal energy storage capacity, specifically the Firebrick Resistance-heated Energy Storage System (FIRES), into future nuclear power plants with high-temperature reactors and Nuclear Air-Brayton combined cycle (NACC) power conversion. The restructuring, or deregulation, of electric power systems in most of Europe and North America has had a substantial impact on the economic performance of currently operating nuclear power plants (NPPs) and the prospects for new builds. Owners of NPPs in some markets have expressed concern that low wholesale electricity market prices and insufficient compensation for capacity, reliability, and other services are threatening the financial viability of their plants. However, both current and future NPPs have the potential to increase their competitiveness by increasing the flexibility of their electricity output. Flexible output has previously only been possible in water-cooled reactors through load-following operation, which requires core power maneuvers and operation of the steam turbine at reduced efficiency. Integration of thermal energy storage systems (TESS) provides an alternative, providing the plant the option to either output electricity or store heat for greater later electric output. The plant owner may thus increase sales of electricity during hours when it is most valuable. Even more, some TESS technologies have the potential to greatly increase the net ramp rate capability of the plant. The ability to rapidly change net power output to the grid may make it possible for NPPs to secure additional revenue by providing additional minute-by-minute balancing services to the grid. FIRES is only one technology out of many that might provide additional technical capabilities at NPPs, and this discussion has only highlighted the opportunities in a single market. Analysis of other options, include steam accumulator systems, nitrate salt TESS, phase change material TESS, and opportunities in other markets are subjects of ongoing work. Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreements end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services, and increase revenue. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multivariable Robust Control of a Simulated Hybrid Solid Oxide Fuel Cell Gas Turbine Plant

This paper presents a systematic approach to the multivariable robust control of a hybrid fuel cell gas turbine plant. The hybrid configuration under investigation comprises a physical simulation of a 300kW fuel cell coupled to a 120kW auxiliary power unit single spool gas turbine. The facility provides for the testing and simulation of different fuel cell models that in turn help identify the key issues encountered in the transient operation of such systems. An empirical model of the facility consisting of a simulated fuel cell cathode volume and balance of plant components is derived via frequency response data. Through the modulation of various airflow bypass valves within the hybrid configuration, Bode plots are used to derive key input/output interactions in Transfer Function format. A multivariate system is then built from individual transfer functions, creating a matrix that serves as the nominal plant in an H-Infinity robust control algorithm. The controller’s main objective is to track and maintain hybrid operational constraints in the fuel cell’s cathode airflow, and the turbo machinery states of temperature and speed, under transient disturbances. This algorithm is then tested on a Simulink/MatLab platform for various perturbations of load and fuel cell heat effluence.

30 DIRECT ENERGY CONVERSION↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Improving methyl ketone production in Escherichia coli by heterologous expression of NADH‐dependent FabG

Abstract We previously engineered Escherichia coli to overproduce medium‐ to long‐chain saturated and monounsaturated methyl ketones, which could potentially be applied as diesel fuel blending agents or in the flavor and fragrance industry. Recent efforts at strain optimization have focused on cofactor balance, as fatty acid‐derived pathways face the systematic metabolic challenge of net NADPH consumption (in large part, resulting from the key fatty acid biosynthetic enzyme FabG [β‐ketoacyl‐ACP reductase]) and net NADH production. In this study, we attempted to mitigate cofactor imbalance by heterologously expressing NADH‐dependent, rather than NADPH‐dependent, versions of FabG identified in previous studies. Of the four NADH‐dependent versions of FabG tested in our previously best‐reported methyl ketone‐producing strain (EGS1895), the version from Acholeplasma laidlawii (Al_FabG) showed the greatest increase in methyl ketone yield in shake flasks (35–75% higher than for an RFP negative‐control strain, depending on sugar loading). An improved strain (EGS2920) attained methyl ketone titers during fed‐batch fermentation of 5.4 ± 0.5 g/L, which were, on average, ca. 40% greater than those for the base strain (EGS1895) under fermentation conditions optimized in this study. Shotgun proteomic data for strains EGS2920 and EGS1895 during fed‐batch fermentation were consistent with the goal of alleviating NADPH limitation through expression of Al_FabG. For example, relative to strain EGS1895, strain EGS2920 significantly upregulated glucose‐6‐phosphate isomerase (directing flux into glycolysis rather than the NADPH‐producing pentose phosphate pathway) and downregulated MaeB (a NADP + ‐dependent malate dehydrogenase). Overall, the results suggest that heterologous expression of NADH‐dependent FabG in E. coli may improve sustained production of fatty acid‐derived renewable fuels and chemicals.

Goh, Ee‐Been↗

Thermal balance of a wall with PCM-enhanced thermal insulation

ABSTRACT: PCM insulation mixtures function as lightweight thermal mass components. It is expected that these types of dynamic insulation systems will contribute to the objective of reducing energy use in buildings. In this paper, dynamic thermal properties of a material in which phase hange occurs are analyzed, using the temperature-dependent specific heat model. Integral formula for the total heat flow in finite time interval, across the surface of a slab of the phase change material, was derived. Simulations have been performed to analyze heat transfer through a light-weight wall assembly with PCM-enhanced insulation, in different external climate thermal conditions. Results of simulations indicate that for cyclic processes, the effect of PCM in an insulation layer results rather in time shifting of the heat flux extreme values than in reduction of the total heat flow. The heat gains maxima, resulting in high cooling loads, are shifted in time by about two hours and reduced about 15% to 30% for not very high external sol-air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transforming Agricultural Systems on Public Lands in the EAA to Support Everglades Restoration

The survival of Florida’s biodiversity and economy is dependent on finding ways to balance farm economics with proper management of water and other natural resources. The state purchase of U.S. Sugar lands in critical areas of south Florida, replacing them with water storage and treatment areas, creates both an opportunity and imperative for new farming systems. These transformed farming system could provide a viable economic and ecological alternative to the reservoirs, STA’s, and flow-way. An agricultural model built around flood-tolerant sugarcane varieties could be compatible with the new visions for EAA lands. Reducing the agricultural intensity of these farms creates the risk or reality of yield reduction and lower farm income, but would allow for water storage, reduced nutrient loads, and muck soil carbon conservation on the farms. Payments for these ecosystem services could offset the loss in crop revenues. Cultivation of flood-tolerant sugarcane allows for temporary storage of water on a field followed by water transfer to an adjacent field. Using this relay approach, a water pulse could be passed down a corridor of fields. The volume of water transported to the south via a pulse way depends largely on the nutrient dynamics of the soil-water system. If the nutrient flux becomes the limiting factor then water volumes sent into the corridors would be limited to the net increase in soil-water storage and ET losses. Including ecosystem services as revenue streams in agricultural business models to compensate for lower yield income requires: (1) quantifying the services delivered, (2) assigning values to the services, and (3) compensating farmers for the quantities delivered. The direct ecosystem services provided by a flood-tolerant sugarcane farming system are (1) water storage, (2) nutrient removal and (3) carbon sequestration. A farming system that significantly reduces soil subsidence and its resulting carbon loss to the atmosphere may be eligible for credit sales on already-existing carbon markets. Farmers and local governments traditionally have been hesitant to consider radically new approaches to agriculture. But facing a significant loss of farms, jobs and tax base creates a receptiveness to change.

54 ENVIRONMENTAL SCIENCES↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗