Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Laboratory chamber experiments exploring the potential use of artificially ionized layers of gas as a Bragg reflector for over-the-horizon signals

A set of parallel plasma layers is generated by two intersecting microwave pulses in a chamber containing dry air at a pressure comparable to the upper atmosphere. The dependence of the breakdown conditions on the pressure and pulse length is examined. The results are shown to be consistent with the appearance of tail erosion of microwave pulse caused by air breakdown. Bragg scattering experiments, using the plasma layers as a Bragg reflector are then performed. Both time domain and frequency domain measurements of wave scattering are conducted. The experimental results are found to agree very well with the theory. Moreover, the time domain measurement of wave scattering provides an unambiguous way for determining the temporal evolution of electron density during the first 100-microsec period.

Kuo, S. P.↗

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical observations of the beam-plasma discharge phenomenon

Spectroscopic observations of optical emissions from the beam-plasma discharge (BPD) phenomenon were made with NASA's vacuum chamber facility, at the Johnson Space Center, configured to simulate the physical conditions of magnetospheric electron beam injection into the ionospheric/upper-atmospheric environment. Nonlinear N2 and N2(+) optical emission growth rates (with respect to incremental electron beam current values) were observed from the chamber gas during transition to the BPD state. For electron-beam currents (I) near the BPD transition value (I(sub c)), the band emissions from the chamber gas produced by relatively low energy (less than or equal to 50 eV) electrons interacting with N2 were anomalously more intense than those requiring higher energy (greater than 100 eV) electrons to excite them. For I more greater than I(sub c), the optical emissions increased linearly with I (as was the case for I less than I(sub c)) and their ratios decreased significantly from the peak values attained when I approximately equals I(sub c). These observations suggest that during BPD some of the energy of the primary electron beam is efficiently transferred, via wave-particle interactions, to local electrons produced through ionization of the chamber gas; the resulting suprathermal electrons provide an additional source of excitation for the relatively low energy states (A, B and C) of N2. Such nonlinear excitation of upper atmospheric gas may occur in certain auroral events wherein the current due to the precipitating electrons approaches a value close to I(sub c).

Sivjee, G. G.↗

Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry

In some recent dosimetry protocols, plastic is allowed as a phantom material for the determination of an absorbed dose to water in electron beams, especially for low energy with beam qualities R{sub 50}<4 g/cm{sup 2}. In electron dosimetry with plastic, a depth-scaling factor, c{sub pl}, and a chamber-dependent fluence correction factor, h{sub pl}, are needed to convert the dose measured at a water-equivalent reference depth in plastic to a dose at a reference depth in water. The purpose of this study is to calculate correction factors for the use of plastic phantoms for clinical electron dosimetry using the EGSnrc Monte Carlo code system. RMI-457 and WE-211 were investigated as phantom materials. First the c{sub pl} values for plastic materials were calculated as a function of a half-value depth of maximum ionization, I{sub 50}, in plastic. The c{sub pl} values for RMI-457 and WE-211 varied from 0.992 to 1.002 and from 0.971 to 0.979, respectively, in a range of nominal energies from 4 MeV to 18 MeV, and varied slightly as a function of I{sub 50} in plastic. Since h{sub pl} values depend on the wall correction factor, P{sub wall}, of the chamber used, they are evaluated using a pure electron fluence correction factor, {phi}{sub pl}{sup w}, and P{sub wall}{sup w} and P{sub wall}{sup pl} for a combination of water or plastic phantoms and plane-parallel ionization chambers (NACP-02, Markus and Roos). The {phi}{sub pl}{sup w} and P{sub wall} (P{sub wall}{sup w} and P{sub wall}{sup pl}) values were calculated as a function of the water-equivalent depth in plastic materials and at a reference depth as a function of R{sub 50} in water, respectively. The {phi}{sub pl}{sup w} values varied from 1.024 at 4 MeV to 1.013 at 18 MeV for RMI-457, and from 1.025 to 1.016 for WE-211. P{sub wall}{sup w} values for plane-parallel chambers showed values in the order of 1.5% to 2% larger than unity at 4 MeV, consistent with earlier results. The P{sub wall}{sup pl} values of RMI-457 and WE-211 were close to unity for all the energy beams. Finally, calculated h{sub pl} values of RMI-457 ranged from 1.009 to 1.005, from 1.010 to 1.003 and from 1.011 to 1.007 for NACP-02, Markus and Roos chambers, respectively, in the range of 4 MeV to 18 MeV, and the values of WE-211 were 1.010 to 1.004, 1.010 to 1.004 and 1.012 to 1.008, respectively. The calculated h{sub pl} values for the Markus chamber agreed within their combined uncertainty with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Primary calibration of coiled {sup 103}Pd brachytherapy sources

Coiled {sup 103}Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S{sub K}) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S{sub K} of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S{sub K} of the longer coiled sources. The UW VAFAC has shown agreement in S{sub K} values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S{sub K} of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental particle formation rates spanning tropospheric sulfuric acid and ammonia abundances, ion production rates, and temperatures

Abstract Binary nucleation of sulfuric acid and water as well as ternary nucleation involving ammonia are thought to be the dominant processes responsible for new particle formation (NPF) in the cold temperatures of the middle and upper troposphere. Ions are also thought to be important for particle nucleation in these regions. However, global models presently lack experimentally measured NPF rates under controlled laboratory conditions and so at present must rely on theoretical or empirical parameterizations. Here with data obtained in the European Organization for Nuclear Research CLOUD (Cosmics Leaving OUtdoor Droplets) chamber, we present the first experimental survey of NPF rates spanning free tropospheric conditions. The conditions during nucleation cover a temperature range from 208 to 298 K, sulfuric acid concentrations between 5 × 10 5 and 1 × 10 9 cm −3 , and ammonia mixing ratios from zero added ammonia, i.e., nominally pure binary, to a maximum of ~1400 parts per trillion by volume (pptv). We performed nucleation studies under pure neutral conditions with zero ions being present in the chamber and at ionization rates of up to 75 ion pairs cm −3 s −1 to study neutral and ion‐induced nucleation. We found that the contribution from ion‐induced nucleation is small at temperatures between 208 and 248 K when ammonia is present at several pptv or higher. However, the presence of charges significantly enhances the nucleation rates, especially at 248 K with zero added ammonia, and for higher temperatures independent of NH 3 levels. We compare these experimental data with calculated cluster formation rates from the Atmospheric Cluster Dynamics Code with cluster evaporation rates obtained from quantum chemistry.

54 ENVIRONMENTAL SCIENCES↗

Filling the vacuum chamber of a technological system with homogeneous plasma using a stationary glow discharge

Experimental study of a glow discharge with electrostatic confinement of electrons is carried out in the vacuum chamber volume V {approx} 0.12 m{sup 3} of a technological system 'Bulat-6' in argon pressure range 0.005-5 Pa. The chamber is used as a hollow cathode of the discharge with the inner surface area S {approx} 1.5 m{sup 2}. It is equipped with two feedthroughs, which make it possible to immerse in the discharge plasma interchangeable anodes with surface area S{sub a} ranging from {approx}0.001 to {approx}0.1 m{sup 2}, as well as floating electrodes isolated from both the chamber and the anode. Dependences of the cathode fall U{sub c} = 0.4-3 kV on the pressure p at a constant discharge current in the range I = 0.2-2 A proved that aperture of the electron escape out of the electrostatic trap is equal to the sum S{sub o} = S{sub a} + S{sub f} of the anode surface S{sub a} and the floating electrode surface S{sub f}. The sum S{sub o} defines the lower limit p{sub o} of the pressure range, in which U{sub c} is independent of p. At p < p{sub o} the cathode fall U{sub c} grows up dramatically, when the pressure decreases, and the pressure p tends to the limit p{sup ex}, which is in fact the discharge extinction pressure. At p {approx} p{sup ex} electrons emitted by the cathode and the first generation of fast electrons produced in the cathode sheath spend almost all their energy up to 3 keV on heating the anode and the floating electrode up to 600-800{sup o}C and higher. In this case the gas in the chamber is being ionized by the next generations of electrons produced in the cathode sheath, their energy being one order of magnitude lower. When S{sub a} < (2m/M){sup 1/2}S, where m is the electron mass and M is the ion mass, the anode may be additionally heated by plasma electrons accelerated by the anode fall of potential U{sub a} up to 0.5 kV.

74 ATOMIC AND MOLECULAR PHYSICS↗

Toward A Precision Era Of Neutrino Oscillation Physics: Liquid Argon Scintillation Detector Development for DUNE and Neutrino Oscillation Studies with NOvA

NOvA is an accelerator-based high-energy particle physics experiment that studies oscillations in a beam of mostly muon (anti-)neutrinos, looking for the disappearance of muon (anti-)neutrinos and appearance of electron (anti-)neutrinos. This search is sensitive to several key neutrino oscillation parameters. After the completion of NOvA, DUNE will continue to study neutrino oscillations with a liquid argon time-projection chamber, which provides finer granularity of tracking than NOvA. Furthermore, the beam will be more powerful, the detector fiducial volume is approximately 3 times larger than the full NOvA detector, and the detector will be situated underground. DUNE is therefore expected to usher in a precision era of long-baseline neutrino oscillation physics. While the main signal from a liquid argon time-projection chamber is the ionization signal produced by the passage of charged particles, argon is also a copious source of scintillation. This light is useful for pro viding a precise event time. Scintillation light is potentially especially useful in non-beam studies in DUNE, such as atmospheric neutrinos, supernova neutrinos, and potential nucleon decay. In this dissertation, I will discuss both projects. In addition to a study of the drift in NOvA’s energy calibration, recent oscillation analysis is discussed, which finds a best fit at $\sin^2\theta_{23}=0.56^{+0.04}_{-0.03}$, $\Delta m^{2}_{32}=2.48^{+0.11}_{-0.06}\times10^{-3}\text{eV}^2$, $\delta_{CP}/\pi=0.0^{+1.3}_{-0.4}$, and prefers normal ordering at 1.9$\sigma$. Contributions to NOvA analysis will also be highlighted, especially methods used to perform separation of neutrinos and antineutrinos in the predominantly antineutrino beam for study. This wrong-sign component is initially used to provide further understanding of the beam components. Furthermore, characterization and prototype testing of photon detectors for DUNE is discussed. Finally, a study is performed with wrong-s ign separation techniques applied to the appearance signal i! n both NOvA and DUNE to create two samples: one enriched in signal and the other enriched in the wrong-sign oscillation appearance. Wrong-sign in the oscillation diminishes the sensitivity of the analysis, so this study aimed to determine if such a separation would enhance the sensitivity of the oscillation. Little benefit was found at the ultimate exposure with NOvA with the techniques currently available, but the study showed potential promise when applied to DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of Beam Intensity Effects in Fermilab Booster Synchrotron. Part II: Beam Emittance Evolution

Detrimental beam dynamics effects limit performance of high intensity rapid cycling synchrotrons (RCS) such as the 8 GeV Fermilab Booster. Here we report the results of comprehensive studies of various beam intensity dependent effects in the Booster. In the previous publication we presented the dependencies of the Booster beam intensity losses on the total number of protons per pulse and on key operational parameters such as the machine tunes and chromaticities. Here we discuss two methods of the Booster beam emittance measurements (the multi-wires proportional chambers and the ionization profile monitors), analyze the intensity dependent emittance growth effects and discuss the ultimate performance of the machine now and after foreseen and proposed upgrades.

43 PARTICLE ACCELERATORS↗

Studies of Beam Intensity Effects in Fermilab Booster Synchrotron. Part I: Introduction, Tune and Chromaticity Scans of Beam Losses

Detrimental beam dynamics effects limit performance of high intensity rapid cycling synchrotrons (RCS) such as the 8 GeV Fermilab Booster. Here we report the results of comprehensive studies of various beam intensity dependent effects in the Booster. Part I covers the dependencies of the Booster beam intensity losses on the total number of protons per pulse and on key operational parameters such as the machine tunes and chromaticities. In Part II we cross-check two methods of the beam emittance measurements (the multi-wires proportional chambers and the ionization profile monitors), analyze the intensity dependent emittance growth effects and discuss the ultimate performance of the machine now and after foreseen and proposed upgrades.

43 PARTICLE ACCELERATORS↗

Single grid accelerator for an ion thrustor

A single grid accelerator system for an ion thrustor is discussed. A layer of dielectric material is interposed between this metal grid and the chamber containing an ionized propellant for protecting the grid against sputtering erosion.

Margosian, P. M.↗

A balloon-borne ionization spectrometer with very large aperture for the detection of high energy cosmic rays

A balloon experiment which was used to determine the chemical composition of very high-energy cosmic rays up to and beyond 100 GeV/nucleon is described. The detector had a geometric factor of 1 sq m sr and a total weight on the balloon of 2100 kg. The apparatus consisted of an ionization spectrometer, spark chambers, and plastic scintillation and Cherenkov counters. It was calibrated at CERN up to 24 GeV/c protons and at DESY up to 7 GeV/c electrons. In October 1972 it was flown successfully on a stratospheric balloon.

Atallah, K.↗

Testing Electronic Devices for Single-Event Upset

Report prepared describes equipment and summarizes both pretest and onsite procedures for testing of digital electronic devices for susceptibility to single-event upset. Term "single-event upset" denotes variety of temporary or permanent bit flips or latchup induced by single particles of ionizing radiation. Vacuum chamber houses device under test while exposed to ion beam. Vacuum chamber and associated equipment must be brought to ion-beam facility for test.

Nichols, D. K.↗

Study of the effective point of measurement for ion chambers in electron beams by Monte Carlo simulation

In current dosimetry protocols for electron beams, for plane-parallel chambers, the effective point of measurement is at the front face of the cavity, and, for cylindrical chambers, it is at a point shifted 0.5r upstream from the cavity center. In this study, Monte Carlo simulations are employed to study the issue of effective point of measurement for both plane-parallel chambers and cylindrical thimble chambers in electron beams. It is found that there are two ways of determining the position of the effective point of measurement: One is to match the calculated depth-ionization curve obtained from a modeled chamber to a calculated depth-dose curve; the other is to match the electron fluence spectrum in the chamber cavity to that in the phantom. For plane-parallel chambers, the effective point of measurement determined by the first method is generally not at the front face of the chamber cavity, which is obtained by the second method, but shifted downstream toward the cavity center by an amount that could be larger than one-half a millimeter. This should not be ignored when measuring depth-dose curves in electron beams. For cylindrical chambers, these two methods also give different positions of the effective point of measurement: The first gives a shift of 0.5r, which is in agreement with measurements for high-energy beams and is the same as the value currently used in major dosimetry protocols; the latter gives a shift of 0.8r, which is closer to the value predicted by a theoretical calculation assuming no-scatter conditions. The results also show that the shift of 0.8r is more appropriate if the cylindrical chamber is to be considered as a Spencer-Attix cavity. In electron beams, since the water/air stopping-power ratio changes with depth in a water phantom, the difference of the two shifts (0.3r) will lead to an incorrect evaluation of the water/air stopping-power ratio at the point of measurement, thus resulting in a systematic error in determining the absorbed dose by cylindrical chambers. It is suggested that a shift of 0.8r be used for electron beam calibrations with cylindrical chambers and a shift of 0.4r-0.5r be used for depth-dose measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-intensity ion sources for accelerators with emphasis on H{sup -} beam formation and transport (invited)

This paper lays out the fundamental working principles of a variety of high-current ion sources for accelerators in a tutorial manner, and gives examples of specific source types such as dc discharge-driven and rf-driven multicusp sources, Penning-type, and electron cyclotron resonance-based sources while discussing those principles, pointing out general performance limits as well as the performance parameters of specific sources. Laser-based, two-chamber, and surface-ionization sources are briefly mentioned. Main aspects of this review are particle feed, ionization mechanism, beam formation, and beam transport. Issues seen with beam formation and low-energy transport of negative hydrogen-ion beams are treated in detail.

43 PARTICLE ACCELERATORS↗

Laser Induced Fluorescence Spectroscopy of Neutral and Ionized Polycyclic Aromatic Hydrocarbons in the Cosmic Simulation Chamber

Polycyclic aromatic hydrocarbon (PAH) molecules are considered the best carriers to account for the ubiquitous infrared emission bands. PAHs have also been proposed as candidates to explain the diffuse interstellar bands (DIBs), a series of absorption features seen on the interstellar extinction curve and are plausible carriers for the extended red emission (ERE), a photoluminescent process associated with a wide variety of interstellar environments. Extensive efforts have been devoted over the past two decades to characterize the physical and chemical properties of PAH molecules and ions in space. Absorption spectra of PAH molecules and ions trapped in solid matrices have been compared to the DIBs. Absorption spectra of several cold, isolated gas-phase PAHs have also been measured under experimental conditions that mimic the interstellar conditions. The purpose of this study is to provide a new dimension to the existing spectroscopic database of neutral and single ionized PAHs that is largely based on absorption spectra by adding emission spectroscopy data. The measurements are based on the laser induced fluorescence (LIF) technique and are performed with the Pulsed Discharge Nozzle (PDN) of the COSmIC laboratory facility at NASA Ames laboratory. The PDN generates a plasma in a free supersonic jet expansion to simulate the physical and the chemical conditions in interstellar environments. We focus, here, on the fluorescence spectra of large neutral PAHs and their cations where there is a lack of fluorescence spectroscopy data. The astronomical implications of the data (e.g., ERE) are examined.

Laboratory↗