Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Condition of cardiovascular systems of astronauts during flight of Soyuz orbital station

Extensive studies of blood circulation functions during manned space flight demonstrated a pronounced tendency toward an increase in minute volume of the blood and a decrease in pulse wave propagation rate. Individual blood circulation indices had large amplitude fluctuations. Physical work loads caused slow recovery of heart rate, arterial pressure and minute blood volume.

Degtyarev, V. A.↗

A simulation analysis of phase processing circuitry in the Ohio University Omega receiver prototype

A FORTRAN IV simulation study of the all-digital phase-processing circuitry is described. A digital phase-lock loop (DPLL) forms the heart of the Omega navigation receiver prototype, and through the DPLL, the phase of the 10.2 KHz Omega signal was estimated when the true signal phase is contaminated with noise. The DPLL uses a frequency synthesizer as the reference oscillator. The synthesizer is composed of synchronous rate multipliers (SRM's) driven by a temperature-compensated crystal oscillator, and the use of the SRM's in this application introduces phase jitter which degrades system performance. Simulation of the frequency synthesizer discussed was to analyze the circuits on a bit-by-bit level in order to evaluate the overall design, to see easily the effects of proposed design changes prior to actual breadboarding, to determine the optimum integration time for the DPLL in an environment typical of general aviation conditions, and to quantify the phase error introduced by the SRM synthesizer and examine its effect on the system.

Palkovic, R. A.↗

Skylab vectorcardiograph: System description and in flight operation

A vectorcardiograph system was used to measure cardiac electrical activity of Skylab crewmen. This system was chosen because of its data-quantification advantages. The vectorcardiograph was required to meet recommended American Heart Association specifications, to withstand space environmental extremes, and to facilitate data gathering in the weightless environment. The vectorcardiograph system performed without failure, and all projected data were acquired. The appendix lists the design specifications used for the Skylab vectorcardiograph system.

Lintott, J.↗

Significance of biorhythms in space flight

Evidence is presented that the most important factor in the maintenance of optimal health and performance is the stability of the relationship of one body rhythm to another. The effect of social interaction on performance, well-being, and physiological rhythm synchrony was investigated. Three groups of healthy males, ages 21 to 25, were confined in rooms (3.4 by 5.2 meters (11 by 17 feet)) for a total period of 105 days. Two of the groups were in rooms in which the environment could be regulated. The third group served as the control group and was exposed to ambient experimental conditions. The confined subjects were exposed for periods to several days either to 16 hours of light and 8 hours of dark, or to continuous light at a light intensity of 161 lm/sq m (15 foot-candles). The confined subjects were deprived of all time cues, and meals were ad libitum. The subjects were observed throughout the study by a video camera and were scored for activity. Communications were limited to meal and sample-collection information, and meals and samples were passed through a two-way hatch. Rectal temperature and heart rate (HR) were sampled every 30 minutes by telemetry throughout the study. Results are presented.

Winget, C. M.↗

Management and design of long-life systems; Proceedings of the Symposium, Denver, Colo., April 24-26, 1973

The long life of Pioneer interplanetary spacecraft is considered along with a general accelerated methodology for long-life mechanical components, dependable long-lived household appliances, and the design and development philosophy to achieve reliability and long life in large turbine generators. Other topics discussed include an integrated management approach to long life in space, artificial heart reliability factors, and architectural concepts and redundancy techniques in fault-tolerant computers. Individual items are announced in this issue.

Schurmeier, H. M.↗

Oxygen cost during exercise in simulated subgravity environments

Oxygen cost (VO2) and heart rate (HR) were determined during treadmill walking in simulated subgravity environments. The long axis of the subject's body was suspended parallel to the floor in a slow rotation room with feet aligned on the surface of a treadmill mounted 90 deg on the wall. Without rotation, the subjects were virtually weightless against the treadmill; with centrifugation, environments of 0.25, 0.5 and 1 G were simulated. Oxygen cost (open circuit) and HR (ECG) were measured during the 5th minute of walking at 3.2, 4.7 and 6.1 km/h. Similar measurements were also determined during walking at 1/2-G using the inclined plane technique. Oxygen cost per unit mass and HR were significantly reduced in all subgravity environments. However, net oxygen cost per unit weight carried and, therefore, mechanical efficiency was found to be independent of gravity. This supports the idea that the most probable cause for the decreased oxygen cost with reduced gravity is less body weight carried.

Fox, E. L.↗

Bringing space technology down to earth

The direct transfer of space technology to terrestial applications is demonstrated by the use of fuel cells to augment existing electric power-generation facilities. The role of NASA's Technology Utilization Program is discussed in regard to indirect transfer of technology. The Tech Brief program for identifying and reporting innovations, the regional dissemination centers, and the Applications Teams working with other government agencies and the medical community are described. Projects discussed include the development of a lightweight breathing apparatus for firemen, a practical method for separating nonferrous metals from automobile scrap, and a rechargeable heart pacemaker.

Gray, E. Z.↗

Synchronous Earth Observatory Satellite /SEOS/

NASA/GSFC is currently studying the applications and technical requirements for a Synchronous Earth Observations Satellite (SEOS). Such a satellite would combine the relatively high resolution and multi-spectral capability of the Earth Resources Technology Satellite (ERTS) with the on-station continuous monitoring of the Synchronous Meteorological Satellite (SMS). SEOS capability is geared to perform disaster warning of tornadoes and floods as well as to monitor transient phenomena affecting earth resources (e.g., green waves and algae blooms). The heart of the system is a Large Earth Survey Telescope (LEST) which has a designed 1.5 meter diameter. Spectral bands in the visible, near- and far-infrared have been selected to optimize SEOS utility. A microwave sounder will be used in conjunction with the LEST for meteorological applications.

Walter, L. S.↗

Instrumented personal exercise during long-duration space flights

The present work reports the results of instrumented personal exercise performed in flight by Skylab 3 and 4 crewmen. Inflight cycle ergometer data provide conclusive evidence that man can perform earthbound equivalent maximum levels of physical work while in the zero-G environment. Moreover, SL4 crewmen were able to improve their physical condition during 84 days of space flight relative to launch condition, due to rigorous personal exercise regimens. Biological data measured included oxygen consumption, CO2 production, minute volume, and heart rate.

Sawin, C. F.↗

Evaluation of viscera and other tissues

Histopathological findings in the lungs, livers, bone marrows, small intestines, gonads, kidneys, and other tissues of the four pocket mice (Perognathus longimembris) that survived the Apollo XVII flight were evaluated in the light of their immediate environment and as targets of HZE cosmic ray particles. Results of this study failed to disclose changes that could be ascribed to the HZE particle radiation. Decreased numbers of erythropoietic cells in the bone marrow of the flight mice were probably related to the increased oxygen pressure. The small intestine showed no changes. Ovaries and testes appeared normal. Two of the three surviving male flight mice displayed early stages of spermatogenesis, just as ground-based controls did at the same season. Abnormalities were also not found in the thyroid, parathyroids, adrenals, or kidneys. The status of the juxtaglomerular apparatus could not be evaluated. The lungs exhibited nonspecific slight reactions. A variety of incidental lesions were noted in the livers of both the flight mice and their controls. The heart muscle showed nothing that could be regarded as pathological. Sections of skeletal muscle examined were free from significant change.

Ellis, J. T.↗

Physiological response to exercise after space flight - Apollo 14 through Apollo 17

Submaximal exercise stress tests were conducted preflight and postflight on the Apollo 14-17 crewmen. A bicycle ergometer was utilized to evoke target heart rates up to 160 beats/min while respiratory gas exchange, blood pressure, and cardiac output were measured. Three preflight tests were conducted during the month prior to flight to establish baseline values for postflight comparisons. Tachycardia was evidenced at rest and during exercise immediately postflight. This transitory tachycardia compensated for reduced stroke volume. Systolic blood pressure was reduced during exercise stress, but no consistent changes were observed in diastolic blood pressure. With the exception of the Apollo 15 crewmen, all crewmen had returned to preflight response levels by the day following recovery. No changes were observed in mechanical or respiratory efficiency immediately postflight.

Rummel, J. A.↗

Effect of varying differentiator frequency response on recorded peak dP/dt

Dogs were used to study the effects of varying the differentiator cutoff frequency on the recorded peak first derivative of left ventricular pressure with respect to time (dP/dt), using high-precision solid-state pressure transducers and recording equipment. In canine hearts with a basic periodicity of 1 to 3 Hz, the differentiator frequency response required to record an accurate peak dP/dt is found to be influenced by the value of peak dP/dt. At peak dP/dt ranging from 1500 to 9000 mm Hg/sec (200 and 1200 kPa/sec), a differentiator cutoff frequency of at least 90 Hz was required to record accurately peak dP/dt.

Barry, W. H.↗

Continuous cardiac output measurement - Aspects of Doppler frequency analysis

From the suprasternal notch blood flow velocity in the aorta can be measured non-invasively by a Doppler probe. Integration over systole after frequency analysis gives a measure of stroke volume if a separate diameter observation is incorporated. Frequency analysis by a zero crossing counter or by a set of parallel phaselock loops was less effective than a set of bandpass filters. Observations on dogs, baboons and humans before and after exercise or surgery suggest the indications to be useful. Application to judging heart failure by the effect of introducing a volume load is indicated. Changes in output also are measured in freely moving subjects.

Mackay, R. S.↗

Skylab experiment M-171 'Metabolic Activity' - Results of the first manned mission

The experiment was performed to ascertain whether man's ability to perform mechanical work would be altered as a result of exposure to the weightless environment. Skylab II crewmen were exercised on a bicycle ergometer at loads approximating 25%, 50%, and 75% of their maximum oxygen uptake while their physiological responses were monitored. The results of these tests indicate that the crewmen had no significant decrement in their response to exercise during their exposure to zero gravity. Immediately postflight, however, all crewmen demonstrated an inability to perform the programmed exercise with the same metabolic effectiveness as they did both preflight and inflight. The most significant changes were elevated heart rates for the same work load and oxygen consumption (decreased oxygen pulse), decreased stroke volume, and decreased cardiac output at the same oxygen consumption level. It is apparent that the changes occurred inflight, but did not manifest themselves until the crewmen attempted to readapt to the 1-G environment.

Michel, E. L.↗

Hemodynamics, renal function, plasma renin, and aldosterone in man after 5 to 14 days of bedrest

Continuous bedrest for 5 to 14 days had no significant effect on resting heart rate, blood pressure, or cardiac output in six normal men. Head-up tilt induced greater tachycardia in 5 of 6 patients after bed rest than in the control period. Propranolol diminished both tachycardia and the incidence of hypotension and faintness in upright posture. Plasma volume fell, extracellular fluid volume increased, and plasma renin activity was significantly elevated following bedrest. Unusually large increases in plasma renin followed head-up tilt or administration of isoproterenol during bedrest and after resuming normal activity. During bedrest, plasma aldosterone was often increased in the early morning. It is concluded that after bedrest, upright posture evokes strong beta-adrenergic activity as well as exaggerated metabolic and circulatory responses which can be reduced or abolished by the beta-adrenergic blocker, propranolol.

Melada, G. A.↗

Reduced baroreflex sensitivity with volume loading in conscious dogs

Results of studies of the Bainbridge reflex in intact conscious dogs are presented. They indicate that arterial baroreflex sensitivity is reduced progressively as atrial pressure is raised by volume loading; this observation explains how heart rate can rise markedly in the presence of an elevated arterial blood pressure.

Vatner, S. F.↗

Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system

An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.

Popp, R. L.↗