At least 1,333 records · Page 74

Solar Technology Test, Evaluation, and Data Collection: Cooperative Research and Development Final Report, CRADA Number CRD-08-279

Under this Agreement, NREL will work with Abengoa Solar Inc. on the testing, evaluation, and collection of data related to Abengoa Solar Inc. solar technologies and systems. This work includes, but is not limited to, testing and evaluation of solar component and system technologies, data collection and monitoring, performance evaluation, reliability testing, thermal energy storage integration, solar resource measurement and forecasting, grid impact testing, and analysis. This work will be conducted at NREL, SolarTAC (Aurora), and other field test locations.

14 SOLAR ENERGY↗

Energy Storage for Social Equity Roundtable Report

In support of the Office of Electricity Energy Storage program, Pacific Northwest National Laboratory (PNNL), hosted a roundtable to explore the relationship between energy equity and energy storage. Flexible and available at any scale, energy storage offers a useful framework and starting point in a larger conversation around energy equity. Through storage, we can imagine more broadly how improvements and investments in the grid can respond to social and health challenges and increase affordability, reliability, and community value in the future. The roundtable featured keynotes and conversations with people leading the charge in transitioning our energy system to a more equitable, affordable, accessible, and sustainable future. This event was presented in collaboration with Sandia National Laboratories.

25 ENERGY STORAGE↗

Communities LEAP: Microgrids 101 [Slides]

Through the Communities Local Energy Action Program (LEAP), NREL is providing technical assistance to a coalition of stakeholders from Oakridge, Oregon. The coalition includes community-based non-profit organizations, the city government, the local utility, and others. Technical assistance provides analysis and information to support Oakridge stakeholders with their goals to increase energy reliability and resilience in the community, while promoting economic development. The Grid Resilience and Microgrids Learning Session was presented to the Oakridge coalition to provide foundational technical knowledge that can support decision-making about energy-related issues in the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetic Amplifier for Power Flow Control

GENI Project: ORNL is developing an electromagnet-based, amplifier-like device that will allow for complete control over the flow of power within the electric grid. To date, complete control of power flow within the grid has been prohibitively expensive. ORNL’s controller could provide a reliable, cost-effective solution to this problem. The team is combining two types of pre-existing technologies to assist in flow control, culminating in a prototype iron-based magnetic amplifier. Ordinarily, such a device would require expensive superconductive wire, but the magnetic iron core of ORNL’s device could serve as a low-cost alternative that is equally adept at regulating power flow.

ARPA-E↗

Voltage Regulation Using a Permanent Magnet Synchronous Generator with a Series Compensator: Preprint

A wind power plant (WPP) is often operated at unity power factor, and the utility host where the WPP connects prefers to regulate the voltage. Although this may not be an issue in a stiff grid, the connection to a weak grid can be a problematic. This paper explores the advantages of having voltage regulation capability via reactive power control. Another issue in wind power generation is that not all turbines are able to control their reactive power due to technical reasons or contractual obligations. A synchronous condenser (SC) using a permanent magnet synchronous generator (PMSG) is proposed to provide necessary reactive power for regulating voltage at a weak grid connection. A PMSG has the advantage of higher efficiency and reliability. Because of its lack of a field winding, a PMSG is typically controlled by a full-power converter, which can be costly. In the proposed system, the reactive power of the SC is controlled by a serially connected compensator operating in a closed-loop configuration. The compensator also damps the PMSG’s tendency to oscillate. The compensator’s VA rating is only a fraction of the rating of the SC and the PMSG. In this initial investigation, the proposed scheme is shown to be effective by computer simulations.

17 WIND ENERGY↗

Design and Operation of Power Systems with Large Amounts of Wind Power: Final Summary Report, IEA WIND Task 25, Phase Three 2012-2014

This report summarizes recent findings on wind integration from the 16 countries participating in the International Energy Agency (IEA) Wind collaboration research Task 25 in 2012-2014. Both real experience and studies are reported. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value in operational timescales (balancing related issues). The first section presents variability and uncertainty of power system-wide wind power, and the last section presents recent wind integration studies for higher shares of wind power. Appendix 1 provides a summary of ongoing research in the national projects contributing to Task 25 in 2015-2017.

17 WIND ENERGY↗

Preparing the Power Sector to Navigate Climate and Water Risks

As the climate changes, so will water availability and other ambient conditions, threatening the reliability of today's power system and tomorrow's clean energy grid. That's why researchers at the National Renewable Energy Laboratory (NREL) - along with those at Sandia National Laboratories, Oak Ridge National Laboratory, the City University of New York, the Electric Power Research Institute, and the National Energy Technology Laboratory - are studying both regional and national climate and hydrologic changes to provide a comprehensive assessment of climate and water impacts and risks to the U.S. power grid.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Cyber-Physical Attack-Resilient Wide-Area Monitoring, Protection, and Control for the Power Grid

Cyber security and resiliency of Wide-Area Monitoring, Protection and Control (WAMPAC) applications is critically important to ensure secure, reliable, and economic operation of the bulk power system. WAMPAC relies heavily on the security of measurements and control commands transmitted over wide-area communication networks for real-time operational, protection, and control functions. Also, the current “N-1 security criteria” for grid operation is inadequate to address malicious cyber events and therefore it is important to fundamentally redesign WAMPAC and to enhance Energy Management System (EMS) applications to make them attack-resilient. In this paper, we propose an end-to-end defense-in-depth architecture for attack-resilient WAMPAC that addresses resilience at both the infrastructure layer and the application layers. Also, we propose an attack-resilient cyber-physical security framework that encompasses the entire security life cycle including risk assessment, attack prevention, attack detection, attack mitigation, and attack resilience. The overarching objective of this paper is to provide a broad scope that comprehensively describes most of the major research issues and potential solutions in the context of cyber-physical security of WAMPAC for the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Renewable Energy Desk Activities for Power Grid Operations and Planning

This document summarizes how grid operators can address gaps in their planning and operations to maintain reliability as they pursue clean energy goals. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage variable renewable energy resource operation. Establishing such a desk in the control room can be a key step in the modernization effort. A renewable energy desk in a control room is a specialized hub focused solely on monitoring, predicting, and managing the influx of energy from renewable sources.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Reinforcement Learning-based Output Structured Feedback for Distributed Multi-Area Power System Frequency Control

Load frequency control (LFC) is a key factor to maintain the stable frequency in multi-area power systems. As the modern power systems evolve from centralized to decentralized paradigm, LFC needs to consider the decentralized scheme that considers limited information from the information-exchange graph for the generator control of each interconnected area. This paper aims to solve a data-driven constrained LQR problem with mean-variance risk constraints and output structured feedback, and applies this framework to solve the LFC problem in multi-area power systems. By reformulating the constrained optimization problem into a minimax problem, the stochastic gradient descent max-oracle (SGDmax) algorithm with zero-order policy gradient (ZOPG) is adopted to find the optimal feedback gain from the learning, while guaranteeing the convergence. In addition, to improve the adaptation of the proposed learning method to new or varying models, we construct an emulator grid that approximates the dynamics of a physical grid and performs training based on this model. Once the feedback gain is obtained from the emulator grid, it is applied to the physical grid with a robustness test to check whether the controller from the approximated emulator applies to the actual system. Numerical tests show that the obtained feedback controller can successfully control the frequency of each area, while mitigating the uncertainty from the loads, with reliable robustness that ensures the adaptability of the obtained feedback gain to the actual physical grid.

Kwon, Kyung-bin↗

Recursive Dynamic Compressive Sensing in Smart Distribution Systems

With a transition to a smarter grid, we are witnessing a significant growth in smart metering infrastructure and sensor deployment in the distribution system. The underlying communication infrastructure is stressed due to the large volume of data that is generated by the smart meters/sensors. Furthermore, real time operations such as state estimation and control are impaired due to the lack of reliable aggregation of the data. In this paper, we exploit the underlying sparsity in grid data to implement two recursive dynamic compressive sensing (CS) approaches-streaming modified weighted-`1 CS and Kalman filtered CS. These approaches aim to reconstruct the sparse signal using the current underdetermined measurements and the prior information about the sparse signal and its support set. Slow signal and support change is in distribution grid data is validated using Pecan Street data. Both the IEEE 34 node test feeder system and PecanStreet data are considered as two examples to validate the superior performance of the two recursive CS techniques relative to classic CS.

Karimi, Hazhar Sufi↗

Electricity Supply Infrastructure Improvements: Final Technical Status Report, December 2010

This report is about a work effort where the overall objectives were to establish a methodology and approach for selected transmission and distribution (T&D) grid modernization; monitor the results; and report on the findings, recommendations, and lessons learned. The work reported addressed T&D problems and solutions, related reliability issues, equipment and operation upgrades, and respectivefield testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Large Eddy Simulation of turbulent flow in rod bundle with spacer grids

Pressurized water nuclear reactor fuel assemblies are made of fuel rods held by spacer grids, which are the core components of the nuclear power plants. Hot fuel rods are cooled by the coolant water flow, and the spacer grids with mixing vanes distort the mainstream, producing the swirling flow which can enhance the heat transfer to improve CHF (Critical Heat Flux). Heat transfer between fuel rods and coolant is a crucial part of thermal-hydraulic analysis. For the purpose to improve the thermal hydraulic performance of the fuel assemblies, many experiments have been conducted to understand the flow structures and three-dimensional behaviors of the turbulence in the rod bundle sub-channels and then to optimize the design of the spacer grid. In the experimental work, which requires lots of efforts to get reliable data, LDA (Laser Doppler Anemometry) and PIV (Particle Image Velocimetry) are generally used to measure the velocity profile and turbulent intensity in the sub-channels. Computational Fluid Dynamics (CFD) is another useful way to study the characteristics of the detailed flow condition and heat transfer phenomena in the subchannels. The main issue of the single-phase CFD is to accurately predict the flow and turbulence characteristics. RANS method is generally used to simulate the induced lateral velocity and the heat transfer process. With the development of computer technology, some more precise but previously time-consuming turbulent models, such as LES (Large Eddy Simulation), are gradually used for the simulation of rod bundle flow with current advanced CPU resources. Ikeno and Kajishima explained the decay of swirling turbulent flow in the rod bundle using LES method. Benhamadouche acquired the turbulence induced forces on the central rod of the rod bundle through performing the LES of the flow downstream the spacer grid. Chang and Tavoularis conducted hybrid simulations with SAS SST and LES of a 5 x 5 rod bundle, and several vortices were identified in the vicinity of the vanes and the generation mechanisms, evolution progress and influence on the velocities of these vortices were clarified. In the paper we present CFD simulations of turbulent flow in rod bundle sub-channels with spacer grids of two different experiments. One is MATiS-H benchmark experiment with scaled spacer grids, which is conducted by KAERI, and is used as a CFD benchmark test, and the other is a 5 x 5 rod bundle with typical spacer grids using PIV technology, with the cooperation of Harbin Engineering University. The main objectives of the calculations are to validate LES methodology by the benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

A Comparison of Fuel Choice for Backup Generators

This poster discusses the costs and benefits of backup generator configurations. We analyze the relative costs and benefits - in terms of economics and reliability - of natural gas versus diesel as fuels for backup systems. We find that, given our assumptions of fuel security for diesel and natural gas, natural gas generators are less likely than diesel generators to fail during a power outage. The differences in likelihoods of failure between natural gas and diesel generators are small for most regions and dependent on several assumptions. This indicates that differences in fuel source security are of second-order concern. We also find that grid-connected generators run for backup as well as additional services have higher reliability due to more frequent operation, and lower net costs than generators used solely for backup. At the same time, emergency-only systems may still be preferred, depending on permitting, noise, and air quality concerns.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗