Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRIDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Global gridded crop harvested area, production, yield, and monthly physical area data circa 2015

Abstract Here we provide an update to global gridded annual and monthly crop datasets. This new dataset uses the crop categories established by the Global Agro-Ecological Zones (GAEZ) Version 3 model, which is based on the Food and Agricultural Organization of the United Nations (FAO) crop production data. We used publicly available data from the FAOSTAT database as well as GAEZ Version 4 global gridded dataset to generate circa 2015 annual crop harvested area, production, and yields by crop production system (irrigated and rainfed) for 26 crops and crop categories globally at 5-minute resolution. We additionally used available data on crop rotations, cropping intensity, and planting and harvest dates to generate monthly gridded cropland data for physical areas for the 26 crops by production system. These data are in standard georeferenced gridded format, and can be used by any global hydrology, land surface, or other earth system model that requires gridded annual or monthly crop data inputs.

54 ENVIRONMENTAL SCIENCES↗

Cyber‐Resilient Distributed Energy Resource Control Algorithms for Smart Distribution Grids

ABSTRACT This paper focuses on the development of cyber‐resilient gradient‐based optimisation algorithms and theoretical proof for grid‐interactive distributed energy resource (DER) control to enable two grid services of virtual power plants (VPPs) dispatch and grid voltage regulation, considering the communication and security impacts. Firstly, the combined DER dispatch and voltage regulation as a real‐time gradient‐based optimisation problem is recapped. Thereafter, we consider a probabilistic traffic model to characterise packet delays and loss in a communication network, and study how the delays enter the process of information exchange among the grid measurement units, local DER controllers and the grid control centre that execute this control algorithm in a coordinated manner. Then, a strategy combining delay thresholds and message update rules is proposed to immunity the asynchrony resulting from the communications traffic and it avoids possible numerical instabilities and sensitivities of the power tracking and voltage regulation capabilities, resulting as cyber‐resilient DER control algorithms. Additionally, their convergence is theoretically proved. Effectiveness of proposed cyber‐resilient algorithms has been validated on the IEEE 37‐bus system in terms of convergence, VPP tracking and voltage regulation performance for smart distribution systems with high penetration of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characteristics of the RF Negative Ion Source Using a Mesh Grid Bias Method

Using a mesh grid bias method for plasma parameter control, volume production of hydrogen negative ions H{sup -} is studied in pure hydrogen rf plasmas. Relationship between the extracted H{sup -} ion currents and plasma parameters is discussed. Both high and low electron temperature T{sub e} plasmas are produced in the separated regions when the grid is negatively biased. In addition, with changing grid potential V{sub g}, values of n{sub e} increase while T{sub e} decrease in their values. The negative ion production depends strongly on the grid potential and related plasma conditions. It is also confirmed that grid bias method is more effective than the so-called magnetic filter method to optimize plasma parameters for H{sup -} production. Production of deuterium negative ions D{sup -} is also studied briefly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Steady state performance test analysis of actively cooled extractor grids for SST-1 neutral beam injector

Neutral beam injection (NBI) system is a workhorse to heat magnetically confined tokamak fusion plasma. The heart of any NBI system is an ion extractor system. Steady State Superconducting Tokamak-1 (SST-1) needs 0.5 MW of hydrogen beam power at 30 kV to raise the plasma ion temperature to {approx}1 keV and 1.7 MW of hydrogen beam power at 55 kV for future upgradation. To meet this requirement, an ion extractor system consisting of three actively cooled grids has been designed, fabricated, and its performance test has been done at MARION test stand, IPP, Julich, Germany. During long pulse (14 s) operation, hydrogen ion beam of energy 31 MJ has been extracted at 41 kV. In this paper, we have presented detailed analysis of calorimetric data of actively cooled extractor grids and showed that by monitoring outlet water temperature, grid material temperature can be monitored for safe steady state operation of a NBI system. Steady state operation of NBI is the present day interest of fusion research. In the present experimental case, performance test analysis indicates that the actively cooled grids attain steady state heat removal condition and the grid material temperature rise is {approx}18 deg. C and saturates after 10 s of beam pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving assessments of tidal power potential using grid refinement in the Coupled Ocean-Atmosphere-Wave-Sediment Transport model

Tidal currents are a promising source for future power generation given their periodicity and predictability. Therefore, numerical hydrodynamic models are frequently utilized for resource assessments. However, the relevant scales of the simulations and hence modeling techniques depend on the problem at hand. This paper shows the potential of the grid refinement technique for the assessment of tidal current energy for particular sites given its relatively low computational expense and high accuracy for the regions with the refined resolution. Example applications are described for mapping the tidal resources near two facilities (Portsmouth Naval Shipyard in Maine and Key West Naval Station in Florida) for possible future deployments of Marine Hydro-Kinetic technologies. The grid refinement capability in the coupled ocean-atmosphere-wave-sediment transport modeling system is used to improve the spatial resolution in the regions of interest, and has shown significant advantage over the original simulation results for the tidal power assessment. The numerical simulation results from both the original coarse grids and the refined grids are validated with measured tidal constituents at available locations. This study demonstrates how the enhancement of a model system for a regional tidal energy with grid refinement can assist with the performance of site specific resource assessments with modest computational expense.

Yang, Xiufeng↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

47 OTHER INSTRUMENTATION↗

NEW ATLAS9 AND MARCS MODEL ATMOSPHERE GRIDS FOR THE APACHE POINT OBSERVATORY GALACTIC EVOLUTION EXPERIMENT (APOGEE)

We present a new grid of model photospheres for the SDSS-III/APOGEE survey of stellar populations of the Galaxy, calculated using the ATLAS9 and MARCS codes. New opacity distribution functions were generated to calculate ATLAS9 model photospheres. MARCS models were calculated based on opacity sampling techniques. The metallicity ([M/H]) spans from -5 to 1.5 for ATLAS and -2.5 to 0.5 for MARCS models. There are three main differences with respect to previous ATLAS9 model grids: a new corrected H{sub 2}O line list, a wide range of carbon ([C/M]) and {alpha} element [{alpha}/M] variations, and solar reference abundances from Asplund et al. The added range of varying carbon and {alpha}-element abundances also extends the previously calculated MARCS model grids. Altogether, 1980 chemical compositions were used for the ATLAS9 grid and 175 for the MARCS grid. Over 808,000 ATLAS9 models were computed spanning temperatures from 3500 K to 30,000 K and log g from 0 to 5, where larger temperatures only have high gravities. The MARCS models span from 3500 K to 5500 K, and log g from 0 to 5. All model atmospheres are publicly available online.

79 ASTRONOMY AND ASTROPHYSICS↗

Gratia: New challenges in Grid accounting

Gratia originated as an accounting system for batch systems and Linux process accounting. In production since 2006 at FNAL, it was adopted by the Open Science Grid as a distributed, grid-wide accounting system in 2007. Since adoption Gratia's next challenge has been to adapt to an explosive increase in data volume and to handle several new categories of accounting data. Gratia now accounts for regular grid jobs, file transfers, glide-in jobs, and the state of grid services. We show that Gratia gives access to a thorough picture of the OSG and discuss the complexity caused by newer grid techniques such as pilot jobs, job forwarding, and backfill.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grid resolution requirement for resolving rare and high intensity wall-shear stress events in direct numerical simulations

Turbulent signals are intermittent with large instantaneous fluctuations. Such large fluctuations lead to small Kolmogorov scales that are hard to resolve in numerical simulations [P. K. Yeung, K. R. Sreenivasan, and S. B. Pope, Effects of finite spatial and temporal resolution in direct numerical simulations of incompressible isotropic turbulence, Phys. Rev. Fluids 3, 064603 (2018)]. Here, the present paper follows the above basic logic, but instead of dissipation events in isotropic turbulence, we study wall-shear stress events in plane channel flow. Wall-shear stress fluctuations are increasingly more intermittent as the Reynolds number increases. Hence, one has to employ higher grid resolutions as the Reynolds number increases in order to resolve a given percentage of wall-shear stress events. The objective of this paper is to quantify effects of the grid resolutions on the rare and high intensity wall-shear stress events. We find that the standard grid resolution resolves about 99% of the wall-shear stress events at Re τ = 180. A slightly higher grid resolution has to be employed in order to resolve 99% of the wall-shear stress events at higher Reynolds numbers, and if the standard grid resolution is used for, e.g., a Re τ = 10000 channel flow, one resolves about 90%–95% wall-shear stress events.

42 ENGINEERING↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

An Inrush Current Limit Method for SiC-based Multi-level Grid-connected Converter During Low-Voltage Ride-Through

Low-voltage ride-through is one of the grid requirements for grid-connected converters, and during the transient of grid voltage change, a large inrush current could be induced due to the control delay of the converter. This inrush current is more severe in SiC-based multi-level converters due to the small filter inductance, which is selected based on harmonics consideration. In this paper, a PWM mask method is used to limit the inrush current of a cascaded H-bridge-based grid-connected converter during the transient of grid voltage change. Simulation and experiment results are provided to validate this method.

Li, Haiguo↗

Instant Startup and Grid Synchronization of Inverter Based Resources

This paper introduces an innovative approach for instant startup of inverter-based resources (IBRs), which attains synchronization with the grid via the already embedded direct current feedback control. The startup process utilizes direct current control throughout each switching cycle, enabling a process that is free from inrush current. Uniquely, this method determines the grid phase angle by evaluating the current differences across switching cycles, a significant difference from traditional methods that often rely on grid or points of common coupling (PCC) voltage. An analytical model has been constructed, highlighting that the grid phase angle can be obtained in just two switching cycles. The paper details the principle of instant grid synchronization and presents both simulation and experimental results to substantiate the proposed method.

He, Yuchen↗

Enabling Technologies for Multinational Interconnected Smart Grid

The multinational interconnected smart grid is a crucial part for the construction of global energy internet, which requires various technologies to support. Based on the key technologies of multinational grid, this paper first states the importance of emerging information communication technologies, such as distributed cloud computing and blockchain, to the safe and stable operation of the grid. Then this paper discusses smart-grid control technologies for power dispatch and grid security. Finally, this paper talks about enabling power electronic technology and analyzes the relationship between power electronics, flexible AC transmission and HVDC transmission technology. To conclude, all these technologies play key roles in enabling multinational interconnected power systems.

Yang, Jianlin↗

Charaterization of Emerging Computing Architectures for Dynamic Simulation of Future Power Grids with Large-Scale Power Electronics

The increasing penetration of power electronics in power grids significantly raises the computing requirements in a real-time (and/or fast) simulation of the power grid. The real-time simulation is an enabler for evaluating controllers, protection systems, new equipment, and twinning. In this paper, emerging computing architectures such as tensor processing units (TPU), neural/neuromorphic processing units (NPU), and quantum processing units (QPU) are introduced and characterized for the real-time (and/or fast) simulation of power electronics-dominated power grids. The metrics and the process to characterize emerging computing architectures to perform real-time (and/or fast) simulations of future power grids with power electronics are discussed. Three of the emerging computing units are characterized based on these metrics and the process developed. This characterization will enable identification and comparison of emerging computing architectures that can perform real-time (and/or fast) simulation of future power grids.

Choi, Jongchan↗

Bio-Inspired Cyber Security for Smart Grid Deployments

mart grid technologies are transforming the electric power grid into a grid with bi-directional flows of both power and information. Operating millions of new smart meters and smart appliances will significantly impact electric distribution systems resulting in greater efficiency. However, the scale of the grid and the new types of information transmitted will potentially introduce several security risks that cannot be addressed by traditional, centralized security techniques. We propose a new bio-inspired cyber security approach. Social insects, such as ants and bees, have developed complex-adaptive systems that emerge from the collective application of simple, light-weight behaviors. The Digital Ants framework is a bio-inspired framework that uses mobile light-weight agents. Sensors within the framework use digital pheromones to communicate with each other and to alert each other of possible cyber security issues. All communication and coordination is both localized and decentralized thereby allowing the framework to scale across the large numbers of devices that will exist in the smart grid. Furthermore, the sensors are light-weight and therefore suitable for implementation on devices with limited computational resources. This paper will provide a brief overview of the Digital Ants framework and then present results from test bed-based demonstrations that show that Digital Ants can identify a cyber attack scenario against smart meter deployments.

McKinnon, Archibald D.↗

Electromagnetic Transient Simulation Algorithms for Evaluation of Large-Scale Extreme Fast Charging Systems (Distribution Grid Models)

The distribution and transmission grids are observing an increased penetration of power electronics in loads and generations. For example, there is increasing interest in integrating in extreme fast charging (XFC) systems for fast charging of electrical vehicles. As these systems are integrated, developing high-fidelity electromagnetic transient model of XFC systems in distribution grids and evaluating their interactions with the power grid would be of significant interest. This model will be utilized for design of XFC systems, to identify upgrades in distribution and/or transmission grids, for planning purposes by transmission planners or operators or owners, among others. It can also be utilized in operations for improved reliable performance of the grid and/or XFC station. The challenge with simulating these models is the high computational complexity introduced by the large number of states present in the system and the time-step needed to simulate the system. In this paper, advanced simulations algorithms are applied to reduce the computational complexity of simulating large-scale XFC systems. The algorithms include numerical stiffness-based segregation, time constant-based segregation, clustering and aggregation on differential algebraic equations (DAEs), and multi-order integration approaches. While the first three algorithms split the matrix that needs to be inverted from a large matrix to much smaller matrices, the final algorithm reduces the computational burden of applying higher-order integration approaches in the complete system. The comparison made in the previous sentence is with respect to use of homogeneous integration approaches used in conventional electromagnetic transient simulators like power systems computer aided design (PSCAD). The approaches mentioned here have resulted in speed-up of 36x in the simulation of a single distribution system with 15 XFCs.

Debnath, Suman↗

Proactive Posturing of Large Power Grid for Mitigating Hurricane Impacts

In the past decade, natural disasters such as hurricanes have challenged the operation and control of U.S. power grid more. It is crucial to develop proactive strategies to assist grid operators for better emergency response and minimized electricity service interruptions. In this paper, we propose a proactive posturing methodology of power system elements, and formulated a Security-Constrained Optimal Power Flow (SCOPF) that informed by cross-domain hurricane modeling and its potential impacts on the grid elements. Simulation results based on real-world power grid and historical hurricane event validated the applicability of the proposed optimization formulation, and show potential to enable grid operators and planners with interactive cross-domain data analytics in mitigating hurricane impacts.

power system emergency response, security constrai↗

Performance Evaluation of Next-Generation Grid Automation and Controls with High PV Penetration

This paper presents a hardware-in-the-loop (BIL) simulation to evaluate the performance of an advanced grid automation architecture, referred to as data-enhanced hierarchical control (DEHC), in achieving voltage regulation and conservation voltage reduction (CVR) in distribution networks with very high photovoltaic (PV) generation. This architecture comprises an advanced distribution management system (ADMS), a distributed energy resource management system (DERMS), and grid-edge devices working synergistically to provide the grid benefits. The HIL setup used for the evaluation includes ADMS, DERMS, and grid-edge devices. The DEHC performance is evaluated in two representative scenarios considering loose and tight constraints of the power factor at the substation. The results show that the DEHC architecture is effective in achieving voltage regulation and CVR and thus enables the grid integration of high levels of PV generation.

ADMS↗