Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “File Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

TH-C-19A-03: Characterization of the Dose Per Pulse Dependence of Various Detectors Used in Quality Assurance of FFF Treatment Plans

Purpose: To present the dose per pulse dependence of various QA devices under Flattening Filter Free (FFF) conditions. Methods: Air and liquid filled ion chamber arrays, diode arrays, radiochromic film and optically stimulated luminescence detectors were investigated. All detectors were irradiated under similar conditions of varying dose per pulse on a TrueBeam linac. Dose per pulse was controlled by varying SSD from 70 to 160 cm providing a range from ~0.5 to ~3 mGy per pulse. MU rates of up to 2400 MU/min for 10X FFF and 1400 MU/min for the 6X FFF beam were used. Beam pulses were counted using the Profiler™ diode array and pulse timing was confirmed by examining linac node files. Delivered doses were calculated with the Eclipse™ treatment planning system. Results: The detectors show a range of behaviors depending on the detector type, as expected. Diode arrays show up to 4% change in sensitivity (sensitivity increases with increasing dose per pulse) over the range tested. Air and liquid ion chambers arrays show a change in sensitivity of up to 3% (air) and 6% (liquid) (sensitivity decreases with increasing dose per pulse) while film and OSLD do not demonstrate a dependence on dose per pulse. Conclusion: Dependence of detector response on dose per pulse varies considerably depending on detector design. Interplay between dose per pulse and MU rate also exists for some detectors. Due diligence is required to characterize detector response prior to implementation of a QA protocol for FFF treatment delivery. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. We intend to further investigate the implications of this for VMAT FFF patient specific quality assurance. T Karan and F Viel have received partial funding through the Varian Research program.

60 APPLIED LIFE SCIENCES↗

Sci—Sat AM: Stereo — 09: Accuracy of Liver Cancer Treatment on Cyberknife® with Synchrony™ Optical Tracking Throughout the Respiratory Cycle

The Cyberknife® robotic stereotactic body radiation therapy system is well-suited for treating liver lesions over the respiratory cycle as it includes room-mounted orthogonal x-ray tracking of internal fiducial markers and optical tracking of external markers. The Synchrony™ software generates a model of internal target positions during patient respiration and correlates it to the external optical tracking system for real-time optical-based position corrections of the linear accelerator during beam delivery. Although clinical studies have provided preliminary outcomes for liver lesions treated with the Cyberknife system, to date, there is little data demonstrating the ability of the Synchrony software to track targets in the liver, which deforms throughout the respiratory cycle. In this study, we investigated the respiratory motion model performance for predicting tumour motion. We conducted a retrospective analysis of fifteen liver cancer patients treated on the Cyberknife using the Synchrony optical tracking system. We analyzed Cyberknife tracking information stored in the log files to extract the left-right (LR), anterior-posterior (AP) and superior-inferior (SI) correlation errors between the model-predicted position and the internal fiducial centroid position determined by x-ray imaging. Only translational tracking and corrections were applied during treatment. Overall, the correlation errors were greatest in the SI direction. We calculated radial correlation errors, and determined that the 95{sup th}, 98{sup th} and 99{sup th} percentile errors were 3.4 mm, 4.4 mm and 5.1 mm, respectively. Based on translational correlation tracking errors we expect the clinical target volume will be within 3.4 mm of the planning target volume for 95 % of beam delivery time.

60 APPLIED LIFE SCIENCES↗

COMMON – Communications System Monitor v. 1.5

COMMON is a tool for collecting, storing, and displaying critical information to facilitate analysis on Microsoft Windows based IT systems. COMMON was developed to provide insight into the IT infrastructure for operational radiation detection systems, but is applicable to most Windows-based operating systems and TCP/IP network components. The COMMON tool aggregates a host of important Windows Management Instrumentation (WMI) information and as well as network ping responses to provide valuable insight into the performance of the IT system. A unique feature is the creation of daily output files (JSON) from the data collected for off site evaluation by subject matter experts.

Aragon, MonaL↗

Streaming Analytics and Data Engineering

SADE is a software package for rapidly assembling analytic pipelines to manipulate data. The packages consists of the engine that manages the data and coordinates the movement of data between the tasks performing a function, a set of core libraries consisting of plugins that perform common tasks, and a framework to extend the system supporting the development of new plugins. Currently through configuration files, a pipeline can be defined that maps the routing of data through a series of plugins. Pipelines can be run in a batch mode or can process streaming data; they can be executed from the command line or run through a Windows background service. There currently exists over a hundred plugins, over fifty pipeline configurations, and the software is now being used by about a half-dozen projects.

Source record↗

SARS-CoV2 Protein-Ligand Simulation Dataset: Layer 1 (Simulation Initial Conditions and Parameters)

A set of 24 protein structures/complexes from the SARS CoV-2 proteome and inputs prepared for simulation using the CHARMM36m forcefield in PDB and gromacs formats. Each system contains a pdb and gromacs top and related input files necessary for running a temperature replica-exchange simulation. In addition, we also include: charmm PSF files (generated from the gromacs topology), a list of temperatures at which replica-exchange simulations were done (tempRamp), example gromacs run input mdp files, and initial minimized structures where available (minimized.pdb).

60 APPLIED LIFE SCIENCES↗

Putting error bars on density functional theory dataset

This dataset contains submission files and raw output files from high-throughput DFT simulations to analyze the systemic errors in lattice constant, bulk moduli and formation energy predictions for a range of binary and ternary oxides using four exchange correlation functionals (LDA, PBE, PBEsol and vdW-DF-C09). This data was then used as the basis for employing materials informatics methods to predict the expected errors in the lattice constants of the studied compounds. Predicted errors were also used to better the DFT-predicted lattice parameters. Our results emphasize the link between the computed errors and the electron density and hybridization errors of a functional. In essence, these results provide “error bars” for choosing a functional for the creation of high-accuracy, high-throughput datasets as well as avenues for the development of XC functionals with enhanced performance, thereby enabling the accelerated discovery and design of new materials.

36 MATERIALS SCIENCE↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗

CO2 and CH4 leaf-level fluxes and soil porewater concentrations from common vegetation patches in Louisiana’s coastal wetlands

This dataset contains leaf-level flux and soil porewater concentration measurements of carbon dioxide (CO2) and methane (CH4 ) in plots in the footprint of Ameriflux sites US-LA2 and US-LA3. Leaf fluxes in US-LA2 were measured on patches dominated by Sagittaria lancifolia and co-dominated by Sagittaria lancifolia and Typha latifolia. In US-LA3, fluxes were measured from distinct Juncus roemerianus and Spartina alterniflora patches. The porewater concentrations were collected across a vertical profile (~50 cm depth) at centric locations within 25 m2 plots where we measured the leaf fluxes. US-LA3 included an additional set of measurements in open water spots. We aimed to evaluate differences in leaf fluxes and porewater pools of CO2 and CH4 of representative ecohydrological patches across a salinity gradient. We also used this dataset to help develop ELM-Wet, a more realistic representation of wetland carbon biogeochemical processes within the U.S. Department of Energy’s Energy Exascale Earth System Model (E3SM) Land Model version 1 (ELM v.1). The files can be opened with regular text editors or spreadsheet programs. Version 2.0 (8/26/2025): This is the latest version of this dataset. The update includes additional samples of soil porewater CH4/CO2 concentrations from June-2021 to November-2022, as well as minor adjustments made to V1 samples via changing Henry's solubility to account for porewater salinity. Additionally leaf-level measurments of spectral indices, PSRI, NDVI, and PRI have been added to complement Leaf-level flux measurements. All V1 data sets have been integrated into V2 sheets, ensuring data from the previous version is contained with the additional samples and consistent with V2 metadata.

54 ENVIRONMENTAL SCIENCES↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibrated Radar Wind Profiler Precipitation Observations and Vertical Velocity Retrievals

A radar wind profiler (RWP) data set collected during the 2-year Department of Energy Atmospheric Radiation Measurement (ARM) Observations and Modeling of the Green Ocean Amazon (GoAmazon2014/5) campaign is used to estimate vertical velocity, designate bulk meteorological echo classification (e.g., convective, stratiform), and provide calibrated radar reflectivity factor Z measurements (calibrated against collocated ground disdrometer and raingauge observations from T3). Additional fields include surface precipitation from rain gauge and ARM InterpolatedSonde streams utilized in the echo classification methods. This dataset follows methods established in Giangrande et al. [2013] and Giangrande et al. [2016] for informing on convective vertical velocities, mass flux and area coverage in Amazon convective cells from ARM RWP systems. If RWP datastreams were unavailable on a given date, files still contain raingauge and InterpolatedSonde information.

54 ENVIRONMENTAL SCIENCES↗

Thermal Radiation Analysis System (TRASYS)

A user's manual is presented for TRASYS, which is a digital software system with a generalized capability for solving radiation problems. Subroutines, file, and variable definitions are presented along with subroutine and function descriptions for the preprocessor. Definitions and descriptions of components of the processor are also presented.

Connor, R. J.↗

Radiometric calibration of the airborne imaging spectrometer

Several laboratory calibration tests were developed for the Airborne Imaging Spectrometer (AIS). The goals of these tests are to adjust the physical alignment of the detector within the optical system and set the spectral endpoints, and produce a calibration file of multipliers which equalizes the relative responses of each of the detector elements in the entire two-dimensional array. Tests are also performed as part of an ongoing effort to provide absolute radiometric calibration. The tests are described and the merits and limitations of each are discussed.

Tucker, D.↗

Calibrated Ancillary System (CAS) user's guide, volume 4

The Calibrated Ancillary System (CAS) provides real-time calibrated parameters from the orbiter downlink (ancillary data) to the Goddard Space Flight Center (GSFC). This user's guide contains the introduction to the equipment, operation, general procedures, and specific procedures of the CAS. Volume 4 presents the GSFC user mission planning procedures covering the mission planning main menu, bulletin board system, ancillary products menu, utility menu procedures, and ancillary support files procedures.

Source record↗

Input/Output Subroutine Library Program

Efficient, easy-to-use program moved easily to different computers. Purpose of NAVIO, Input/Output Subroutine Library, provides input/output package of software for FORTRAN programs that is portable, efficient, and easy to use. Implemented as hierarchy of libraries. At bottom is very small library containing only non-portable routines called "I/O Kernel." Design makes NAVIO easy to move from one computer to another, by simply changing kernel. NAVIO appropriate for software system of almost any size wherein different programs communicate through files.

Collier, James B.↗

The SPAN cookbook: A practical guide to accessing SPAN

This is a manual for remote users who wish to send electronic mail messages from the Space Physics Analysis Network (SPAN) to scientific colleagues on other computer networks and vice versa. In several instances more than one gateway has been included for the same network. Users are provided with an introduction to each network listed with helpful details about accessing the system and mail syntax examples. Also included is information on file transfers, remote logins, and help telephone numbers.

Mason, Stephanie↗

IMP: A performance code

IMP (Integrated Mission Program) is a simulation language and code used to model present and future Earth, Moon, or Mars missions. The profile is user controlled through selection from a large menu of events and maneuvers. A Fehlberg 7/13 Runge-Kutta integrator with error and step size control is used to numerically integrate the differential equations of motion (DEQ) of three spacecraft, a main, a target, and an observer. Through selection, the DEQ's include guided thrust, oblate gravity, atmosphere drag, solar pressure, and Moon gravity effects. Guide parameters for thrust events and performance parameters of velocity changes (Delta-V) and propellant usage (maximum of five systems) are developed as needed. Print, plot, summary, and debug files are output.

Dauro, Vincent A., Sr.↗

A procedure for automating CFD simulations of an inlet-bleed problem

A procedure was developed to improve the turn-around time for computational fluid dynamics (CFD) simulations of an inlet-bleed problem involving oblique shock-wave/boundary-layer interactions on a flat plate with bleed into a plenum through one or more circular holes. This procedure is embodied in a preprocessor called AUTOMAT. With AUTOMAT, once data for the geometry and flow conditions have been specified (either interactively or via a namelist), it will automatically generate all input files needed to perform a three-dimensional Navier-Stokes simulation of the prescribed inlet-bleed problem by using the PEGASUS and OVERFLOW codes. The input files automatically generated by AUTOMAT include those for the grid system and those for the initial and boundary conditions. The grid systems automatically generated by AUTOMAT are multi-block structured grids of the overlapping type. Results obtained by using AUTOMAT are presented to illustrate its capability.

Chyu, Wei J.↗