Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Integration of Biological, Physical/Chemical and Energy Efficient Systems in the CELSS Antarctic Analog: Performance of Prototype Systems and Issues for Life Support

The Controlled Ecological Life Support System (CELSS) Antarctic Analog Project (CAAP) is a joint endeavor between the National Science Foundation, Office of Polar Programs (NSF-OPP), and the National Aeronautics and Space Administration (NASA). The fundamental objective is to develop, deploy, and operate a testbed of advanced life support technologies at the Amundsen-Scott South Pole Station that enable the objectives of both the NSF and NASA. The functions of food production, water purification, and waste treatment, recycle, and reduction provided by CAAP will improve the quality of life for the South Pole inhabitants, reduce logistics dependence, enhance safety, and minimize environmental impacts associated with human presence on the polar plateau. Because of the analogous technical, scientific, and mission features with Planetary missions, such as a mission to Mars, CAAP provides NASA with a method for validating technologies and overall approaches to supporting humans. Prototype systems for waste treatment, water recycle, resource recovery and crop production are being evaluated in a testbed at Ames Research Center. The combined performance of these biological and physical/chemical systems as an integrated function in support of the human habitat will be discussed. Overall system performance will be emphasized. The effectiveness and efficiency of component technologies will be discussed in the context of energy and mass flow within the system and contribution to achieving a mass and energy conservative system. Critical to the discussion are interfaces with habitat functions outside of the closed-loop life support: the ability of the system to satisfy the life support requirements of the habitat and the ability to define input requirements. The significance of analog functions in relation to future Mars habitats will be discussed.

Bubenheim, David L.↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Solar energy in buildings: Implications for California energy policy

An assessment of the potential of active solar energy systems for buildings in California is summarized. The technology used for solar heating, cooling, and water heating in buildings is discussed. The major California weather zones and the solar energy designs are described, as well as the sizing of solar energy systems and their performance. The cost of solar energy systems is given both at current prices and at prices consistent with optimistic estimates for the cost of collectors. The main institutional barriers to the wide spread use of solar energy are summarized.

Hirshberg, A. S.↗

Solar energy collection system

A fixed, linear, ground-based primary reflector having an extended curved sawtooth-contoured surface covered with a metalized polymeric reflecting material, reflects solar energy to a movably supported collector that is kept at the concentrated line focus reflector primary. The primary reflector may be constructed by a process utilizing well known freeway paving machinery. The solar energy absorber is preferably a fluid transporting pipe. Efficient utilization leading to high temperatures from the reflected solar energy is obtained by cylindrical shaped secondary reflectors that direct off-angle energy to the absorber pipe. A seriatim arrangement of cylindrical secondary reflector stages and spot-forming reflector stages produces a high temperature solar energy collection system of greater efficiency.

Miller, C. G.↗

SNS Credited Pulse Energy Limit System Conceptual Design

The Controls Group at the Spallation Neutron Source (SNS) is designing a programmable signal processor based credited safety control that calculates pulsed beam energy based on beam kinetic energy and charge. The SNS Pulsed Energy Limit System (SPELS) must reli-ably shut off the beam if the average power exceeds 2.145 MW averaged over 60 seconds. This paper will cover the architecture and design choices needed to develop the system under the auspices of a programma-ble radiation-safety credit control. The authors will also introduce the concept of a graded failure approach that allows the credited system to continue operation in the presence of some faults.

Deibele, Craig↗

Conceptual Design Study of a Thermal Energy Storage System Using Granular Solids for Coal-fired Boilers

<span style="font-size: 12pt;">Presentation for the 2020 International Pittsburgh Coal Conference held virtually from September 8-11, 2020.</span><span style="font-size: 12pt;">Abstract: As electricity from various renewable energy sources is increasingly supplied to the power grid, the grid’s stability will be challenged. Proposed grid-stability solutions will need to address variability of sources, such as solar and wind energy, in order to alleviate problems such as overgeneration and ramping. In regions where increases in solar energy are prominent, such as California, the net power demand curve often referred to as “the Duck Curve,” has caused problems for energy dispatchers, due to over-generation and fast ramping demands. In this project, we investigated a conceptual design for a Thermal Energy Storage System (TESS) integrated into a coal-fired power plant to support grid-scale storage. Implementing a TESS into power plants can allow for an increase in renewable sources, increase grid resilience, and allow conventional coal-fired plants to operate more efficiently. For this project, a TESS using granular solids as the energy-storage media is integrated into a conventional coal-fired power plant. The purpose of the TESS is to store energy from the flue gas during low demand periods and transfer the energy to steam during peak demand periods. The storage allows the stabilization of combustion and related boiler components at low loads and provides the opportunity to avoid some shutdowns. This study uses thermodynamic properties of several candidate thermal storage materials to estimate the size of storage system required for several operating scenarios. </span>

Huckaby, E. David↗

Capacity optimization of nuclear power integration to meet dynamic industrial demand

To decarbonize their industrial facilities, The Dow Chemical Company has collaborated with Idaho National Laboratory (INL) to study the integration of nuclear power with an industrial chemical facility. Using Holistic Energy and Resource Optimization Network developed at INL for optimizing and analyzing integrated energy systems, a nuclear microreactor system was sized and evaluated for dynamic dispatch to Dow Silicones Corporation’s Carrollton, KY (USA) site for iloxane production. It was found that a 180 MW th system (12 × 15MW th ) with 75.1 MWh th of thermal energy storage could provide heat and power to the chemical facilities. In the process, this would reduce electricity imports by 99.9 % and reduce the Scope 1 and 2 emissions of the site by 292,100 tonnes CO 2 /yr (98.8 %). The primary novelty of this work is a first of a kind design and optimization of a microreactor powered integrated energy system to provide heat and power to a chemical plant using real plant data. This analysis will pave the way for future studies using dispatchable clean energy sources to reduce carbon emissions and commodity industries’ reliance on fossil fuels.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Chapter 7: Integrative Science

A key part of DOE's mission is addressing energy and environmental problems through transformative science and technology, which includes discovering and developing new energy systems and understanding and predicting their consequences at local to global scales. Enabling these advances are the fundamental scientific discoveries and tools delivered by the Office of Science. Implicit in DOE's mission is the need to understand the complex, multiscale interactions between energy systems and the environment. Attaining this knowledge requires an integrated research portfolio that promotes understanding and discovery across different subsystems of the overall energy system and enables sustainable prosperity through a vibrant bioeconomy.

Biological and Environmental Research Advisory Com↗

Midwest Nuclear-based Net-Zero Carbon Steelmaking Demonstration

Globally, the iron and steel industry accounts for around a quarter of GHG emissions from the manufacturing sector , which is about 7% of the 33 gigatonnes (Gt) of global CO 2 emissions . Thus, globally, the steel industry is a 2-3 Gt CO 2 per year emissions challenge. The steel industry is important to the U.S. economy with output equal to $0.5 trillion and domestic production capacity is critical to national defense, infrastructure, energy production, and transportation. President Biden’s executive order on climate identifies actions and policies to put the Nation on a path to achieve net-zero carbon emissions, economy-wide, by no later than 2050. To achieve this, deep carbon reductions in the power, transportation, buildings and capital-intensive industrial manufacturing segments such as steel, cement and chemicals need to be addressed. In its recent “Accelerating Decarbonization of the U.S. Energy System” report , the National Academy of Sciences (NAS) stated that, “while technology exists to decarbonize all parts of the energy system, some sectors remain at precommercial or first-of-a-kind demonstration stages and require significant improvement in cost and performance to become commercially viable.” The NAS goes on to state that these hard to decarbonize sectors include “aviation, shipping, and industrial subsectors such as steel, cement, and chemicals manufacturing .” The Administration has proposed a timeline to decarbonize energy, transportation and then industry and manufacturing. From a life-cycle approach, decarbonizing steel and other large industrial inputs are necessary to decarbonize transformations in energy and transportation. DOE’s TRI-Lab Consortium’s Integrated Energy Systems (IES) program is a collaboration amongst DOE’s three applied energy laboratories: the National Energy Technology Laboratory; National Renewable Energy Laboratory and Idaho National Laboratory. The IES approach looks at more tightly integrating low-carbon nuclear energy, renewable electricity, energy storage, load/demand balancing, and biomass (including plastics and other wastes) with one or more industrial processes that utilize heat and/or power from these clean and waste energy sources to produce a low-carbon commodity-scale product.

08 HYDROGEN↗

Creating a High Energy Alert System for the HAWC Gamma Ray Observatory [Slides]

One of the greatest mysteries in astrophysics is exactly how Cosmic Rays (CRs) are accelerated up to extremely high energies within our galaxy. Hadronic models of possible CR accelerators, including supernova remnants and pulsars, require the production of both gamma rays and neutrinos at these sources. Searching for coincidences between neutrino and the highest energy gamma ray observations can help confirm these theories. The High Altitude Water Cherenkov (HAWC) observatory is a ground based gamma ray observatory located at 4100m in Puebla, Mexico. HAWC is able to detect gamma rays with energies greater than 100 TeV, has a wide field of view, and a 95% duty cycle, making it ideal for these types of coincidence searches. This work aims to create a high energy alert system for HAWC, sending out an alert to other experiments for gamma ray events it sees above 56 TeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-tlie-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-the-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predictive-Maintenance Practices: For Operational Safety of Battery Energy Storage Systems

Changes in the Demand Profile and a growing role for renewable and distributed generation are leading to rapid evolution in the electric grid. These changes are beginning to considerably strain the transmission and distribution infrastructure. Utilities are increasingly recognizing that the integration of energy storage in the grid infrastructure will help manage intermittency and improve grid reliability. This recognition, coupled with the proliferation of state-level renewable portfolio standards and rapidly declining lithium-ion (Li-ion) battery costs, has led to a surge in the deployment of battery energy storage systems (BESSs). Additionally, although BESSs represented less than 1% of grid-scale energy storage in the United States in 2019, they are the preferred technology to meet growing demand because they are modular, scalable, and easy to deploy across diverse use cases and geographic locations.

25 ENERGY STORAGE↗