Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Rovibrational energy transfer in the He-C{sub 3} collision: Potential energy surface and bound states

We present a four-dimensional potential energy surface (PES) for the collision of C{sub 3} with He. Ab initio calculations were carried out at the coupled-cluster level with single and double excitations and a perturbative treatment of triple excitations, using a quadruple-zeta basis set and mid-bond functions. The global minimum of the potential energy is found to be −26.9 cm{sup −1} and corresponds to an almost T-shaped structure of the van der Waals complex along with a slightly bent configuration of C{sub 3}. This PES is used to determine the rovibrational energy levels of the He-C{sub 3} complex using the rigid monomer approximation (RMA) and the recently developed atom-rigid bender approach at the Close Coupling level (RB-CC). The calculated dissociation energies are −9.56 cm{sup −1} and −9.73 cm{sup −1}, respectively at the RMA and RB-CC levels. This is the first theoretical prediction of the bound levels of the He-C{sub 3} complex with the bending motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy Spectrum of Ultrahigh-Energy Cosmic Rays across Declinations -90° to +44.8° as Measured at the Pierre Auger Observatory

The energy spectrum of cosmic rays above 2.5 EeV has been measured across the declination range - 9 0 ° ≤ δ ≤ + 44.8 ° using ∼ 310 000 events accrued at the Pierre Auger Observatory from an exposure of ( 104 900 ± 3 100 ) km 2 sr yr . No significant variations of energy spectra with declination are observed, after allowing or not for nonuniformities across the sky arising from the well-established dipolar anisotropies in the arrival directions of ultrahigh-energy cosmic rays. Here, the instep feature in the spectrum at ≃ 10 EeV reported previously is now established at a significance above 5 σ . Within the statistics, the energy spectra are indistinguishable across declinations so disfavoring an origin for the instep from a few distinctive sources.

Abdul Halim, A. [University of Adelaide]↗

Changes in the Zero-Point Energy of the Protons as the Source of the Binding Energy of Water to A-Phase DNA

The measured changes in the zero-point kinetic energy of the protons are entirely responsible for the binding energy of water molecules to A phase DNA at the concentration of 6 water molecules/base pair. The changes in kinetic energy can be expected to be a significant contribution to the energy balance in intracellular biological processes and the properties of nano-confined water. The shape of the momentum distribution in the dehydrated A phase is consistent with coherent delocalization of some of the protons in a double well potential, with a separation of the wells of 0.2 Angst .

74 ATOMIC AND MOLECULAR PHYSICS↗

Modeling and Assessment of Integrated Hydroelectric Power and Hydrogen Energy Storage

Environmental and regulatory constraints are increasingly posing challenges to the optimal operation of hydroelectric facilities. Hydrogen energy storage (HES) is well-suited to address these challenges.Using excess or low-cost hydroelectric power during off-peak hours to produce hydrogen can help reduce water spills and unlock opportunities for energy arbitrage. Moreover, the oxygen byproduct of electrolysis can be used to improve the dissolved oxygen (DO) levels in tailrace water. %, a key water quality metric for hydroelectric facilities.This paper presents an innovative framework for modeling and assessing the integrated hydroelectric-hydrogen system, considering subsystem constraints and coupling, benefits in spill water reduction and DO mitigation, as well as diverse hydrogen utilization, including re-electrification, blending with natural gas, and direct sales. Comprehensive case studies were conducted to assess the techno-economic performance of the integrated system in different deployment scenarios.

Energy storage, Hydrogen, Hydropower, Optimization↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Wave Energy Converter Control Competition: Overview

Over the past two years, a wave energy converter control systems competition (WECCCOMP) has been in progress, with the objective of comparing different wave energy converter (WEC) control paradigms on a standard benchmark problem. The target system is a point absorber, corresponding to a single float with an absolute reference, of the WaveStar WEC prototype. The system was modelled in WEC-Sim, with the hydrodynamic parameters validated against tank test data. Competitors were asked to design and implement a WEC control system for this model, with performance evaluated across six sea states. The evaluation criteria included a weighted combination of average converted power, peak/average power, and the degree to which the system physical constraints were exploited or temporarily exceeded.

16 TIDAL AND WAVE POWER↗

Umbilical Fatigue Analysis for a Wave Energy Converter

Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.

50 EE - Wind and Water Power Program - Water (EE-4↗

Lessons Learned from Net Zero Energy Assessments and Renewable Energy Projects at Military Installations

Report highlights the increase in resources, project speed, and scale that is required to achieve the U.S. Department of Defense (DoD) energy efficiency and renewable energy goals and summarizes the net zero energy installation assessment (NZEI) process and the lessons learned from NZEI assessments and large-scale renewable energy projects implementations at DoD installations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Michigan Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the Michigan Uniform Energy Code

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Michigan homeowners. Moving to the 2012 IECC from the Michigan Uniform Energy Code is cost-effective over a 30-year life cycle. On average, Michigan homeowners will save $\$$10,081 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$604 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Metering Best Practices Applied in the National Renewable Energy Laboratory's Research Support Facility: A Primer to the 2011 Measured and Modeled Energy Consumption Datasets

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Services du Centre de Solutions Pour Les Energies Propres (Fact Sheet) [Clean Energy Solutions Center Services]

This is the French translation of the Clean Energy Solutions Center services fact sheet. The Clean Energy Solutions Center (Solutions Center) helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NREL's Clean Energy Policy Analyses Project: 2009 U.S. State Clean Energy Data Book

This data book provides a summary of the status of state-level energy efficiency and renewable energy (taken together as clean energy) developments and supporting policy implementation. It is intended as a reference book for those interested in the progress of the states and regions toward a clean energy economy. Although some national-scale data are given in the initial section, the data are mostly aggregated by states and region, and no data on federal- or utility-level policies are presented here.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Washington Clean Energy Fund: Energy Storage System Performance Test Plans and Data Requirements

This report documents the test plans, including detailed duty cycles, used in evaluating the technical performance of five energy storage systems (ESSs) sponsored by the Washington State Clean Energy Fund (CEF). These ESSs were installed at three participating utilities’ (Avista, Snohomish Public Utility District or SnoPUD, and Puget Sound Energy or PSE) designated sites. Under each test plan, a number of baseline and use case tests are defined. This report documents the test plan for each utility, including duty cycles, data and performance reporting requirements. Baseline tests defined in this report mainly focus on determining an initial or reference performance for each ESS, which may be compared with the performance at any later time to assess the state of health of the ESS. Parameter values of a given ESS obtained from baseline tests are applied for different modeling purposes and use case tests. The stored energy capacity test is the first test conducted in the baseline test program, which generates data to calculate round trip efficiency (RTE). The response time and ramp rate tests provide the time required for an ESS to change from zero to full charging/discharging rate and hence the ramp rate, which is important in understanding ESS performance for applications calling for fast response. Internal resistance testing of ESS cells is also conducted in conjunction with the response time and ramp rate tests. Finally, the baseline tests include frequency regulation (FR) and peak shaving (PS) tests based on real-world duty cycles. Upon completion of the baseline tests, use case tests are conducted at each of the storage sites with duty cycles developed to meet the site-specific criteria and conditions. The use cases are grouped according to their intended target benefits within the electric infrastructure topology (e.g., transmission versus distribution). Although an ESS may be located on the low-voltage side of a substation that provides power to a distribution feeder, a use case that addresses bulk power services could still be provided and would be grouped under the transmission or bulk-power benefits. Use cases for ESS applications deep into the distribution circuit would be categorized under the distribution system cases.

25 ENERGY STORAGE↗

Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

This report provides an assessment as to whether new buildings constructed to the commercial energy-efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The purpose of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Economic Development Benefits from Wind Energy in Nebraska: A Report for the Nebraska Energy Office (Revised)

This report focuses on the economic development impacts estimated from building and operating 7,800 MW of new wind power in Nebraska. This level of development is on the scale envisioned in the Department of Energy (DOE) report 20% Wind Energy by 2030. A practical first step to building 7,800 of wind is completing 1,000 MW. We also include the estimated economic impacts to Nebraska from building 1,000 MW of wind power. Our primary analysis indicates that the development and construction of approximately 7,800 MW of wind energy in Nebraska by 2030 will support 20,600 to 36,500 annual full-time equivalents (AFTE). In addition, operating the full 7,800 MW of wind energy could support roughly 2,000 to 4,000 full-time workers throughout the operating life of the wind facilities (LFTE). Nebraska's economy is estimated to see an average annual boost in economic activity ranging from $140 million to $260 million solely from construction and development related activities between 2011 and 2030. An additional boost of $250 - $442 million annually is estimated from operating 7,800 MW of wind capacity.

17 WIND ENERGY↗

Uncertainty Quantification in Wind Plant Energy Estimation: Preprint

Data characterizing a wind power plant's production is important for the validation, calibration, and refinement of the wake loss models used to simulate performance for pre-construction energy estimates. In this process, there is the potential for significant variation in the methods used by an analyst for, first, the preparation of the operational production data for comparison to model data and, second, the generation of analogous production data from simulations. In this work, the uncertainty introduced by these method variations is quantified by considering ensembles of analysis methods. Specifically, 1920 methods variations were developed for preparing the operational data as a predictable production benchmark and simulations taking as input sample sets of the observed wind resource ranged in size from covering 4% to 125% of a full year were run using 3 engineering wake loss models in FLORIS simulations. The benchmark and simulation input uncertainties place lower bounds on the precision of the calibration between the simulation model estimates and operational benchmark data. Even within subsets of method variations (representative of what might be seen within a single company), the uncertainty in the predictable expected production is estimated to be between 1% and 3% the median predictable expected production while the uncertainty in the simulated expected production remains at best on the order of 2%. To put this into context: the simulated expected production is very closely related to the annual energy production (AEP) metric commonly used to quantify a plant's predicted performance and a 3% error in the pre-construction AEP estimate can result in a $17M loss due to additional financing costs for a typical 100MW Texas plant.

17 WIND ENERGY↗

Grand Challenges: wind energy research needs for a global energy transition

Wind energy is anticipated to play a central role in enabling a rapid transition from fossil fuels to a system based largely on renewable power. For wind power to fulfill its expected role as the backbone – providing nearly half of the electrical energy – of a renewable-based, carbon-neutral energy system, critical challenges around design, manufacture, and deployment of land and offshore technologies must be addressed. During the past 3 years, the wind research community has invested significant effort toward understanding the nature and implications of these challenges and identifying associated gaps. The outcomes of these efforts are summarized in a series of 10 articles, some under review by Wind Energy Science (WES) and others planned for submission during the coming months. This letter explains the genesis, significance, and impacts of these efforts.

17 WIND ENERGY↗