Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the contribution to the signal of the increased number of out-of-time interactions per beam crossing following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (2015–2018) demonstrate a substantial improvement in the energy resolution of the calorimeter over a range of energies extending from a few GeV to several tens of GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic shower reconstruction and energy validation with Michel electrons and π 0 samples for the deep-learning-based analyses in MicroBooNE

This article presents the reconstruction of the electromagnetic activity from electrons and photons (showers) used in the MicroBooNE deep learning-based low energy electron search. The reconstruction algorithm uses a combination of traditional and deep learning-based techniques to estimate shower energies. We validate these predictions using two v μ -sourced data samples: charged/neutral current interactions with final state neutral pions and charged current interactions in which the muon stops and decays within the detector producing a Michel electron. Both the neutral pion sample and Michel electron sample demonstrate agreement between data and simulation. Finally, the absolute shower energy scale is shown to be consistent with the relevant physical constant of each sample: the neutral pion mass peak and the Michel energy cutoff.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Performance of the ALICE Electromagnetic Calorimeter

The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010–2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the detector, the procedures for data taking, reconstruction, and validation are explained. The methods used for the calibration and various derived corrections are presented in detail. Subsequently, the capabilities of the calorimeter to reconstruct and measure photons, light mesons, electrons and jets are discussed. The performance of the calorimeter is illustrated mainly with data obtained with test beams at the Proton Synchrotron and Super Proton Synchrotron or in proton-proton collisions at $\sqrt{s}$ = 13 TeV, and compared to simulations.

47 OTHER INSTRUMENTATION↗

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ELECTROMAGNETIC TRANSIENTS POWERED BY NUCLEAR DECAY IN THE TIDAL TAILS OF COALESCING COMPACT BINARIES

We investigate the possibility that long tidal tails formed during compact object mergers may produce optical transients powered by the decay of freshly synthesized r-process material. Precise modeling of the merger dynamics allows for a realistic determination of the thermodynamic conditions in the ejected debris. We combine hydrodynamic and full nuclear network calculations to determine the resultant r-process abundances and the heating of the material by their decays. The subsequent homologous structure is mapped into a radiative transfer code to synthesize emergent model light curves and determine how their properties (variability and color evolution) depend on the mass ratio and orientation of the merging binary. The radiation emanating from the ejected debris, though less spectacular than a typical supernova, should be observable in transient surveys and we estimate the associated detection rates. We find that it is unlikely that photometry alone will be able to distinguish between different binary mass ratios and the nature of the compact objects, emphasizing the need for spectroscopic follow-up of these events. The case for (or against) compact object mergers as the progenitors of short gamma-ray bursts can be tested if such electromagnetic transients are detected (or not) in coincidence with some bursts, although they may be obscured by on-axis afterglows.

79 ASTRONOMY AND ASTROPHYSICS↗

ON DISCOVERING ELECTROMAGNETIC EMISSION FROM NEUTRON STAR MERGERS: THE EARLY YEARS OF TWO GRAVITATIONAL WAVE DETECTORS

We present the first simulation addressing the prospects of finding an electromagnetic (EM) counterpart to gravitational wave (GW) detections during the early years of only two advanced detectors. The perils of such a search may have appeared insurmountable when considering the coarse ring-shaped GW localizations spanning thousands of square degrees using time-of-arrival information alone. Leveraging the amplitude and phase information of the predicted GW signal narrows the localization to arcs with a median area of only a few hundred square degrees, thereby making an EM search tractable. Based on the locations and orientations of the two LIGO detectors, we find that the GW sensitivity is limited to only two of the four sky quadrants. Thus, the rates of GW events with two interferometers is only ≈40% of the rate with three interferometers of similar sensitivity. Another important implication of the sky quadrant bias is that EM observatories in North America and Southern Africa would be able to systematically respond to GW triggers several hours sooner than Russia and Chile. Given the larger sky areas and the relative proximity of detected mergers, 1 m class telescopes with very wide-field cameras are well-positioned for the challenge of finding an EM counterpart. Identification of the EM counterpart amidst the larger numbers of false positives further underscores the importance of building a comprehensive catalog of foreground stellar sources, background active galactic nucleus and potential host galaxies in the local universe. This initial study is based on a small sample of 17 detected mergers; future works will expand this sample.

79 ASTRONOMY AND ASTROPHYSICS↗

PROSPECTS FOR JOINT GRAVITATIONAL-WAVE AND ELECTROMAGNETIC OBSERVATIONS OF NEUTRON-STAR-BLACK-HOLE COALESCING BINARIES

Coalescing neutron-star-black-hole (NS-BH) binaries are a promising source of gravitational-wave (GW) signals detectable with large-scale laser interferometers such as the Advanced Laser Interferometer Gravitational-Wave Observatory and Virgo. They are also one of the main short gamma-ray burst (SGRB) progenitor candidates. If the black hole (BH) tidally disrupts its companion, an SGRB may be ignited when a sufficiently massive accretion disk forms around the remnant BH. Detecting an NS-BH coalescence both in the GW and electromagnetic (EM) spectrum offers a wealth of information about the nature of the source. How much can actually be inferred from a joint detection is unclear, however, as a mass/spin degeneracy may reduce the GW measurement accuracy. To shed light on this problem and on the potential of joint EM+GW observations, we here combine recent semi-analytical predictions for the remnant disk mass with estimates of the parameter-space portion that is selected by a GW detection. We identify cases in which an SGRB ignition is supported, others in which it can be excluded, and finally others in which the outcome depends on the chosen model for the currently unknown NS equation of state. We pinpoint a range of systems that would allow us to place lower bounds on the equation of state stiffness if both the GW emission and its EM counterpart are observed. The methods we develop can broaden the scope of existing GW detection and parameter-estimation algorithms and could allow us to disregard about half of the templates in an NS-BH search following an SGRB trigger, increasing its speed and sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic frame-dragging correction to the electromagnetic solution of a compact neutron star

ABSTRACT Neutron stars are usually modelled as spherical, rotating perfect conductors with a predominant intrinsic dipolar magnetic field anchored to their stellar crust. Due to their compactness, General Relativity corrections must be accounted for in Maxwell’s equations, leading to modified interior and exterior electromagnetic solutions. We present analytical solutions for slowly rotating magnetized neutron stars, taking into account the magnetic frame-dragging correction. For typical compactness values, i.e. Rs ∼ 0.5 [R*], we show that the new terms lead to a per cent order correction in the magnetic field orientation and strength compared to the case, with no magnetic frame-dragging correction. Also, we obtain a self-consistent redistribution of the surface azimuthal current. We verify the validity of the derived solution through two-dimensional particle-in-cell simulations of an isolated neutron star. Defining the azimuthal electric and magnetic field amplitudes during the transient phase as observables, we prove that the magnetic frame-dragging correction reduces the transient wave amplitude, as expected from the analytical solution. We show that simulations are more accurate and stable, when we include all first-order terms. The increased accuracy at lower spatiotemporal resolutions translates into a reduction in simulation runtimes.

Torres, R. (ORCID:0000000291820228)↗

Quantum Langevin theory for two coupled phase-conjugated electromagnetic waves

We provide a general macroscopic phenomenological formula of quantum Langevin equations for two coupled phase-conjugated electromagnetic fields with linear loss (gain) and complex nonlinear coupling coefficient. The macroscopic phenomenological formula is obtained from the coupling matrix to preserve the field commutation relations and correlations, which does not require knowing the microscopic details of light-matter interaction and internal atomic structures. To validate this phenomenological formula, we take spontaneous four-wave mixing in a double-Λ four-level atomic system as an example to numerically confirm that our macroscopic phenomenological result is consistent with that obtained from the microscopic Heisenberg-Langevin theory. We find that a complex-valued nonlinear coupling coefficient can lead to noises even without linear gain or loss. Lastly, we apply the quantum Langevin equations to study the effects of linear gain and loss, complex phase mismatching, as well as complex nonlinear coupling coefficient in entangled photon pair (biphoton) generation, particularly to their temporal quantum correlations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conservation law for electromagnetic fields in a space-time-varying medium and its implications

We discuss the propagation of electromagnetic waves in a space-time modulated medium, for which neither energy nor momentum remains conserved. We have found a new conservation law when modulation moves at a constant speed v in a traveling-wave fashion. We use this law to study how light is scattered inside such a medium. We consider both the subluminal (v < c) andsuperluminal (v > c) cases and find that they differ considerably in terms of what remains conserved. We show that the total number of photons is conserved in the subluminal case. In contrast, it is the difference between the forward and backward moving photons that remains conserved in the superluminal case. We also study the reciprocity issue for a space-time modulated medium and found that reciprocity holds in all situations. Here, we develop a quantum formulation of our scattering problem and show that the subluminal case is similar to the action of a beam splitter. In the superluminal case, photon pairs can be generated from vacuum in a fashion analogous to the two-mode frequency down-conversion process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetically induced transparency with noisy lasers

We demonstrate and characterize two coherent phenomena that can mitigate the effects of laser phase noise for electromagnetically induced transparency (EIT): a laser-power-broadening-resistant resonance in the transmitted intensity cross correlation between EIT optical fields, and a resonant suppression of the conversion of laser phase noise to intensity noise when one-photon noise dominates over two-photon-detuning noise. Our experimental observations are in good agreement with both an intuitive physical picture and numerical calculations. The results have wide-ranging applications to spectroscopy, atomic clocks, and magnetometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetic modes in cavities made of negative-index metamaterials

We discuss electromagnetic modes in cavities formed by metamaterials with negative refraction and demonstrate that the straightforward approach to substitute negative values of the electric permittivity and the magnetic permeability leads to quasibound states with a negative quality factor. To ensure positive quality factors and a consistent physical interpretation of the quasibound states it is essential to include the frequency dispersion of the permittivity and the permeability, as required by positive field energy and causality. The basic mode equation and the boundary conditions including linear frequency dispersion are derived. As an example we consider a disklike cavity with deformed cross-sectional shape. The transition from the unphysical nondispersive case with negative quality factors to the dispersive case with positive quality factors is demonstrated numerically and in an analytical perturbative treatment.

36 MATERIALS SCIENCE↗

Dissipative light scattering by a trapped atom approaching electromagnetically-induced-transparency conditions

We study the time dependence of the spectrum of inelastically scattered radiation from a trapped atom. The atom is illuminated by two lasers tuned to the electromagnetically induced transparency (EIT) of the free atom. For counterpropagating laser beams, rapid removal of vibrational energy is observed as the atom approaches near-EIT conditions. We show that the imbalance in the sidebands of the scattered radiation spectrum explains quantitatively the cooling of the center-of-mass motion of the trapped atom. We also examine parameters critical for EIT cooling in situations far from the Lamb-Dicke limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entanglement between collective fields via phase-dependent electromagnetically induced transparency

We show that it is possible to obtain continuous variable entanglement for four optical fields via phase-dependent electromagnetically induced transparency in a four-level system in double-{Lambda} configuration. Due to quantum interference, the four fields constitute two quantum beats, behave as a pair of collective modes, and experience high cross Kerr nonlinearities. As a result, entanglement occurs between the two collective modes and between any two individual fields from the different collective modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Narrow-linewidth double-resonance optical pumping spectrum due to electromagnetically induced transparency in ladder-type inhomogeneously broadened media

Based on the cesium 6S{sub 1/2}-6P{sub 3/2}-8S{sub 1/2} ladder-type atomic system, double-resonance optical pumping (DROP) spectra including electromagnetically induced transparency (EIT) effects have been investigated with a room-temperature cesium vapor cell. For both cases of the probe and the coupling laser beams passing through the cesium vapor cell with the counter-propagation (CTP) and co-propagation (CP) configurations, the DROP spectra measured in the experiment display explicitly different linewidths. Thanks to the EIT effect, the linewidth of the DROP spectrum is explicitly narrower for the CTP configuration than for the CP configuration. Experimental results agree with the theoretical analysis considering Doppler averaging. Furthermore, when the coupling laser has moderate power, the DROP spectrum for the CTP configuration clearly shows two components: the narrow part due to the EIT effect and the broad part caused by optical pumping (but these two different components are never seen in the CP configuration). Also, the effect of the intensity of the coupling and probe lasers on the DROP spectra is investigated.

74 ATOMIC AND MOLECULAR PHYSICS↗