Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Photometric and CCD direct image observation of comet Encke

Attempted detection of periodic variations in brightness of the comet Encke is described. Viewing problems due to the position, faintness, and rate of motion of the comet are discussed. The failure of attempts to perform photoelectric photometry and CCD imaging is described. Photometric observations of the prototype Earth crosser, (1862) Apollo, are described and a photoelectric light curve of observations made during a four-hour period is presented.

Mccrosky, R. E.↗

Time-domain Brillouin scattering theory for probe light and acoustic beams propagating at an angle and acousto-optic interaction at material interfaces

A theory has been developed to interpret time-domain Brillouin scattering (TDBS) experiments involving coherent acoustic pulse (CAP) and light pulse beams propagating at an angle to each other. It predicts the influence of the directivity pattern of their acousto-optic interaction on TDBS signals when heterodyne detection of acoustically scattered light is in backward direction to incident light. The theory reveals relationships between the carrier frequency, amplitude and duration of acoustically induced ”wave packets” in light transient reflectivity signals, and factors such as CAP duration, widths of light and sound beams, and their interaction angle. It describes the transient dynamics of these wave packets when the light and CAP encounter material interfaces, and how the light scattering by the incident CAP transforms into scattering by the reflected and transmitted CAPs. The theory suggests that single-point TDBS experiments can determine not only depth positions of buried interfaces but also their local inclinations/orientations.

42 ENGINEERING↗

Three‐trophic level food webs support the safety of a biocontrol agent 3 years after release

Biological control (biocontrol) is a powerful tool for managing invasive alien species and assisting the restoration of native ecosystems. Rigorous post‐release monitoring of biocontrol agents is critical to evaluate the success of biocontrol programs; however, this is still rarely implemented. Here, we combined the use of species interaction networks with a Before‐After Control‐Impact design to evaluate the target and non‐target, direct and indirect effects of the Australian gall wasp Trichilogaster acaciaelongifoliae , released to control the invasive plant Acacia longifolia in Portugal. We compared the structure of plant‐galling insect‐parasitoid food webs before and 3 years after the release of the biocontrol agent. Exhaustive sampling did not detect any non‐target effects, either direct (on non‐target plants) or indirect (on other galling insects via shared plants). Additionally, no significant changes were detected in network structure that could be related to the establishment of the biocontrol agent. This study shows that monitoring biocontrol at the community level is possible and that, when carefully planned, biocontrol poses minimal risk of non‐target effects.

López‐Núñez, Francisco A. [Centre for Functional E↗

Fully depleted charge‐coupled device design and technology development

Abstract We describe the advancement of fully depleted charge‐coupled device (CCD) technology for scientific applications. Recent efforts on 650–725 m‐thick CCDs for direct dark‐matter and radiation detection with single‐electron sensitivity are described, as well as the technology transfer of the fully depleted CCD technology to 200 mm‐wafer fabrication facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Nature of Magnetic Excitations in the High-Field Phase of α–RuCl 3

We present comprehensive electron spin resonance (ESR) studies of in-plane oriented single crystals of α–RuCl 3 , a quasi-two-dimensional material with honeycomb structure, focusing on its high-field spin dynamics. The measurements were performed in magnetic fields up to 16 T, applied along the [110] and [100] directions. Several ESR modes were detected. Combining our findings with recent inelastic neutron- and Raman-scattering data, we identified most of the observed excitations. Most importantly, we show that the low-temperature ESR response beyond the boundary of the magnetically ordered region is dominated by single- and two-particle processes with magnons as elementary excitations. In conclusion, the peculiarities of the excitation spectrum in the vicinity of the critical field are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large-scale efficient mid-wave infrared optoelectronics based on black phosphorus ink

The mid-wave infrared (MWIR), ranging from 2 to 5 micrometers, is of substantial interest for chemical sensing, imaging, and spectroscopy. Black phosphorus (bP)–based MWIR light emitters and detectors have been shown to outperform the state-of-the-art for commercial devices due to the low Auger recombination coefficient of bP. However, the scalability of these devices remains a challenge. Here, we report a bP ink formula that preserves the exceptional MWIR optoelectronic properties of bP to deposit centimeter-scale, uniform, and pinhole free films with a photoluminescence quantum yield higher than competing III-V and II-VI semiconductors with similar bandgaps at high excitation regime. As a proof of concept, we use bP ink as a “phosphor” on a red commercial light-emitting diode to demonstrate bright MWIR light emission. We also show that these films can be integrated into heterostructure device architectures with electron and hole selective contacts for direct-injected light emission and detection in MWIR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Background Adaptive Radiation Detection (BARD) v1.0.0

The Background Adaptive Radiation Software can be deployed with static sensors in urban environments. It provides a real-time robust radiation detection based on a unique adaptive learning approach. Local radiation background models are automatically learnt for various environmental conditions, and monitored/re-trained, and selected over time for optimal radiation anomaly detection, informed by source templates directly derived from the data.

Abgrall, Nicolas↗

Geophysical and Planetary Acoustics on Balloons

Natural events and human activity often generate acoustic waves capable of traveling tens to tens of thousands of kilometers across the globe. Ground-based acoustic sensors are limited to dry land and often suffer from wind noise. In contrast, balloon borne acoustic sensors can cross oceans, polar ice caps, and other inhospitable areas, greatly expanding sensor coverage. Since they move with the mean wind speed, their background noise levels are exceptionally low. In the last six years, such sensors have recorded sounds from colliding ocean waves, surface and buried chemical explosions, thunder, wind/mountain interactions, wind turbines, aircraft, and possibly meteors and the aurora. These results have led to new insights on acoustic heating of the upper atmosphere, the detectability of underground explosions, and directional sound fields generated by ocean waves.

47 OTHER INSTRUMENTATION↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Review of In Situ Sensing for Directed Energy Deposition for Industrial Part Quality Assessment

As the use additive manufacturing (AM) processes continues to grow in critical industries, improved quality assurance methods are becoming increasingly sought after for qualification and certification of AM components. Traditional nondestructive evaluation of printed components is often unable to supply the required confidence in print quality to justify qualification and certification, but the layer-by-layer nature of AM provides unprecedented opportunities for in situ quality inspection. This document summarizes recent developments in process monitoring research specifically related to Directed Energy Deposition (DED). Particular attention is given to three aspects of the highlighted manuscripts: (1) the type of sensors used, (2) features extracted from each sensor modality, and (3) analysis of extracted features for AM quality assessment. Based on the review of the state-of-the-art, several observations have been made. First, none of the reviewed works have applied their trained models to real part geometries, with many of the works relying on single track experiments, thin-walled structures, and cubes. Similarly, there have not been any works demonstrating model generalizability, i.e., a model trained on data from one build allows for fruitful analysis of data from another build. Many works used machine learning techniques to distinguish different process regimes (i.e., normal, keyholing, lack-of-fusion), but very few papers have investigated stochastic variation in an already “optimized” process. Sensor fusion approaches are also limited in the DED sensing literature, but the few works that have employed such techniques have demonstrated the benefits. Finally, registration of in situ data to the build coordinate system is of paramount importance to producing industrially relevant in situ monitoring systems. Data registration allows direct correlations between process anomalies detected in the process monitoring data to localized departures in part quality, but such techniques are generally lacking in the current literature.

36 MATERIALS SCIENCE↗

Stellar Bragg crystal X-ray spectrometry on OSO-1

A high sensitivity crystal X-ray spectrometer for use on the Orbiting Solar Observatory (mission 1) satellite is described. This instrument will be used to obtain both solar and stellar spectra in the energy range 2 to 8 keV. In the stellar mode, the shape of the continua, the strength of lines, and the strength of recombination and absorption edge were determined. If lines or edges are detected, such data will provide direct evidence regarding the physical conditions in the emitting and absorbing regions. If only upper bounds are established, the data can be used to constrain theoretical models. In any case, precise continuum shapes will be established for a number of the brighter X-ray sources. Numerical estimates of the sensitivity of the instrument for these various purposes are given.

Landecker, P. B.↗

Decision-directed detector for overlapping PCM/NRZ signals.

A decision-directed (DD) technique for the detection of overlapping PCM/NRZ signals in the presence of white Gaussian noise is investigated. The performance of the DD detector is represented by probability of error Pe versus input signal-to-noise ratio (SNR). To examine how much improvement in performance can be achieved with this technique, Pe's with and without DD feedback are evaluated in parallel. Further, analytical results are compared with those found by Monte Carlo simulations. The results are in good agreement.

Wang, C. D.↗

A flash photolysis-resonance fluorescence study of the formation of O(D-1) in the photolysis of water and reaction of O(D-1) with H2, Ar and He

The relative importance of two primary processes in the photolyis of water: (1) H2O + h (nu) yields H + OH, and (2) H2O + h (nu) yields H2 + OD-1 were determined in a direct manner by time resolved detection (via resonance fluorescence) of H and O formed in processes 1 and 2 respectively. The initially formed OD-1 was deactivated to ground state OP-3 prior to detection via resonance fluorescence. The relative quantum yields for processes 1 and 2 are 0.89 and 0.11 for the wavelength interval 105 to 145nm and = to or greater than 0.99, and = to or less than 0.01 for the wavelength interval 145 to 185nm. Rate constants at 300 K for the reactions OD-1 + H2, + Ar, and + He are presented.

Stief, L. J.↗

Effluent sampling of Titan 3 C vehicle exhaust

Downwind in situ ground-level measurements of the exhaust from a Titan 3 C launch vehicle were made during a normal launch. The measurement activity was conducted as part of an overall program to obtain field data for comparison with the multilayer dispersion model currently being used to predict the behavior of rocket vehicle exhaust clouds. All measurements were confined to land, ranging from the launch pad to approximately 2 kilometers downwind from the pad. Measurement systems included detectors for hydrogen chloride (HCl), carbon dioxide (CO2), and particulates (Al2O3). Airborne and ground-based optical systems were employed to monitor exhaust cloud rise, growth, and movement. These measurement systems, located along the ground track (45 deg azimuth from the launch pad) of the exhaust cloud, showed no effluents attributable to the launch. Some hydrogen chloride and aluminum oxide were detected in the surface wind direction (15 deg azimuth) from the pad. Comparisons with the model were made in three areas: (1) assumption of cloud geometry at stabilization; (2) prediction of cloud stabilization altitude; and (3) prediction of the path of cloud travel. In addition, the importance of elemental analyses of the particulate samples is illustrated.

Gregory, G. L.↗

Shadow mask for X-ray spectrometer

Imaging technique may be used in series with flat or conical Bragg crystals to separate spatial/spectral convolution when spectrometer is scanned across extended source emitting at more than one wavelength. Technique allows line direction and continuum to be detected and provides data for spatial mapping of source.

Woodgate, B. E.↗