Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

The James Webb Space Telescope

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISIM optical metering structure is a roughly 2.2x1.7x2.2mY, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISM structure must meet its requirements at the approx.40K cryogenic operating temperature. The SIs are aligned to the structure s coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified.

Nowak, Maria↗

The Electrifying Future of Air Transportation

This presentation discusses the NASA Aeronautics Advanced Air Transport Technology Project’s perspective on electric, hybrid-electric, and related distributed propulsion technologies for future generations of large transport aircraft. Recent system studies commissioned by NASA and other organizations have identified these technologies as promising approaches to dramatically reduce aircraft fuel consumption, noise, and emissions. These technologies are part of the Project’s overall research portfolio aimed toward developing ultra-efficient commercial aircraft in conjunction with alternative low carbon propulsion and energy systems to enable safe and sustainable future growth in global aviation. It is anticipated that both room temperature and cryogenic electrical technologies will be needed in the future. Room temperature electrical systems are likely to impact aviation in the near term by making their way onto smaller aircraft and by augmenting traditional propulsion systems on larger aircraft, while cryogenic technologies will likely be needed in the far term to deliver the several tens of megawatts of propulsive power needed for large transport aircraft. The presentation outlines the opportunities and challenges for electric propulsion technologies for commercial aviation, and describes some of the related concepts and enabling technologies that are currently being developed.

Future↗

On-wafer, cryogenic characterization of ultra-low noise HEMT devices

Significant advances in the development of high electron-mobility field-effect transistors (HEMT's) have resulted in cryogenic, low-noise amplifiers (LNA's) whose noise temperatures are within an order of magnitude of the quantum noise limit (hf/k). Further advances in HEMT technology at cryogenic temperatures may eventually lead to the replacement of maser and superconducting insulator superconducting front ends in the 1- to 100-GHz frequency band. Key to identification of the best HEMT's and optimization of cryogenic LNA's are accurate and repeatable device measurements at cryogenic temperatures. This article describes the design and operation of a cryogenic coplanar waveguide probe system for the characterization and modeling of advanced semiconductor transistors at cryogenic temperatures. Results on advanced HEMT devices are presented to illustrate the utility of the measurement system.

Bautista, J. J.↗

Pressure- and Temperature-Sensitive Paint at 0.3-m Transonic Cryogenic Tunnel

Recently both Pressure- and Temperature-Sensitive Paint experiments were conducted at cryogenic conditions in the 0.3-m Transonic Cryogenic Tunnel at NASA Langley Research Center. This represented a re-introduction of the techniques to the facility after more than a decade, and provided a means to upgrade the measurements using newer technology as well as demonstrate that the techniques were still viable in the facility. Temperature-Sensitive Paint was employed on a laminar airfoil for transition detection and Pressure-Sensitive Paint was employed on a supercritical airfoil. This report will detail the techniques and their unique challenges that need to be overcome in cryogenic environments. In addition, several optimization strategies will also be discussed.

Watkins, A. Neal↗

Technology Demonstration Mission (TDM) evolvable Cryogenics (eCryo) Project Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) Diode Rake Assembly and Installation

NASA designed, assembled and installed a temperature diode rake into the SHIIVER test article for use of measuring liquid and gaseous hydrogen temperatures. Several special steps were taken to ensure that fluid temperatures were measured as opposed to structural temperatures. This document outlines design practices and methodologies that have become standard practice at Glenn Research Center to ensure the measurement of fluid temperatures for cryogenic systems research.

Cryogenic Fluid Management↗

Development and Acceptance Testing of the Dual Wheel Mechanism for the Tunable Filter Imager Cryogenic Instrument on the JWST

The James Webb Space Telescope (JWST) will carry four scientific instruments, one of which is the Tunable Filter Imager (TFI), which is an instrument within the Fine Guidance Sensor. The Dual Wheel (DW) mechanism is being designed, built and tested by COM DEV Ltd. under contract from the Canadian Space Agency. The DW mechanism includes a pupil wheel (PW) holding seven coronagraphic masks and two calibration elements and a filter wheel (FW) holding nine blocking filters. The DW mechanism must operate at both room temperature and at 35K. Successful operation at 35K comprises positioning each optical element with the required repeatability, for several thousand occasions over the five year mission. The paper discusses the results of testing geared motors and bearings at the cryogenic temperature. In particular bearing retainer design and PGM-HT material, the effects of temperature gradients across bearings and the problems associated with cooling mechanisms down to cryogenic temperatures. The results of additional bearing tests are described that were employed to investigate an abnormally high initial torque experienced at cryogenic temperatures. The findings of these tests, was that the bearing retainer and the ball/race system could be adversely affected by the large temperature change from room temperature to cryogenic temperature and also the temperature gradient across the bearing. The DW mechanism is now performing successfully at both room temperature and at cryogenic temperature. The life testing of the mechanism is expected to be completed in the first quarter of 2010.

Leckie, Martin↗

In Situ Formation of Ripplocations in Hybrid Organic–Inorganic MXenes

Abstract Inorganic–organic hybrid MXenes (h‐MXenes) are a family of 2D transition metal carbides and nitrides functionalized with alkylimido and alkylamido surface groups. Using cryogenic and room temperature scanning transmission electron microscopy (STEM) and electron energy‐loss spectroscopy (EELS), it is shown that ripplocations, a form of a fundamental defect in 2D and layered structures, are abundant in this family of materials. Furthermore, detailed studies of electron probe sample interactions, focusing on structural deformations caused by the electron beam are presented. The findings indicate that at cryogenic temperatures (≈100 K) and below a specific dose threshold, the structure of h‐MXenes remains largely intact. However, exceeding this threshold leads to electron beam‐induced deformation through ripplocations. Interestingly, the deformation behavior, required dose, and resultant structure are highly dependent on temperature. At 100 K, it is demonstrated that the electron beam can induce ripplocations in situ with a high degree of precision.

Chemistry↗

Accurate, rapid, temperature and liquid-level sensor for cryogenic tanks

Thermopiles measure ullage gas temperatures to within plus or minus 1.65 deg K between 20 and 300 deg K, and also serve as point liquid-level sensors. Thermopile technique measures smaller temperature differences by keeping the reference junctions inside the tank and near the temperature range of the measuring junction.

De Witt, R. L.↗

Reusable High-Temperature/Cryogenic Foam-Insulation System

Flightweight insulation withstands wide temperture cycling. Reusable insulation system for cryogenic containment vessels withstands repeated exposures to thermal environments that span ranges from cryogenic-fluid temperature {-425oF (-254oC)} to maximum use temperature of containment-tank material {+400oF (+204oC)}. System designed for use with high-speed flight vehicles.

Davis, Randall C.↗

Cryogenic Angle Measurement at NASA Langley

NASA’s National Transonic Facility is one of the few cryogenic wind-tunnel facilities in the world, where tunnel conditions may reach -250 F. Model angle of attack (AoA) at NTF is typically measured by an on-board accelerometer package that is exposed to the cryogenic tunnel conditions. These NTF AoA packages house two Q-Flex accelerometers in a compact heated environment in order to maintain constant temperature of the sensors for stability. Recently, drift in sensor output was observed in one of the NTF AoA packages. The drift is correlated with the AoA package temperature and cryogenic soak time. This paper studies the temperature and time dependent behavior of the NTF AoA packages, and reviews their design and calibration. Recommended improvements to the AoA packages are made to improve the stability of the model angle of attack measurements at cryogenic conditions.

Toro, Kenneth G.↗

On the Use of Liquid Nitrogen Droplets as Flow Tracers in Cryogenic Flow Facilities at NASA Langley Research Center

The injection of liquid nitrogen droplets to cool the gas temperature in cryogenic wind tunnels is discussed as a method of natural seeding for velocimetry-focused, particle-based, laser diagnostics. Historical observations and issues with seeding are presented for both ground-test facilities of interest in this work at NASA Langley: the 0.3-m Transonic Cryogenic Wind Tunnel (TCT) and the National Transonic Facility (NTF). Recent observations of natural seeding with a Rayleigh scattering instrument are presented in the two facilities, which motivated the purposeful use of a pulse-burst laser system to observe the particles directly with a sequentially operated laser sheet for the first time. Time-resolved image sequences of unevaporated liquid nitrogen droplets were readily acquired for tunnel total temperatures of 200 K and below. The preliminary results promote a discussion on the fitness of these natural particles as flow tracers for either a particle image velocimetry or a particle tracking velocimetry instrument in these high-Reynolds-number facilities.

cryogenic wind tunnels↗

Use of Au@Void@TiO 2 yolk-shell nanostructures to probe the influence of oxide crystallinity on catalytic activity for low-temperature oxidations

A series of Au@Void@TiO 2 yolk-shell structures were synthesized and characterized, and their catalytic activity was tested for the oxidation of carbon monoxide. The target of this study was to evaluate the effects of (1) the crystallinity of the TiO 2 shell and (2) the presence of titanate phases. Transmission electron microscopy and X-ray diffraction data show that increasing calcination temperatures, from 850 to 1250 K, leads to the formation of larger titania crystallites. These crystallites are typically in the form of anatase, but some rutile is also made at high temperatures. The general yolk-shell nanostructures retain their basic characteristics upon calcination and upon treatment with HCl (used to remove the titanate phases), but a few structural and chemical changes do take place: (1) the void-space diameter is reduced by approximately 10% when going from T Calc = 850 K to T Calc = 1250 K, a change that is accompanied by a decrease in the surface area (estimated from N 2 adsorption-desorption isotherms); (2) the shell thickness remains unaffected by either calcination or HCl treatment; (3) the pore volume also remains approximately constant with increasing calcination temperature in the catalysts free of titanates but diminishes significantly in the samples with titanate phases; (4) the mesoporosity is minimal in all yolk-shell nanostructures but more noticeable with the pure TiO 2 shells; (5) the titanates have high Na content (measured by X-ray photoelectron spectroscopy), but that Na is fully removed upon treatment with HCl; (6) no Ti 3+ was detectable in any of the samples, but silica, together with C and (minor amounts of) N, was present in all; (7) all Au is in metallic form; (8) two temperature regimes were observed for the catalytic oxidation of CO, as reported for other similar samples in the past, an Arrhenius regime around or above room temperature, and a cryogenic range going to temperatures as low as 120 K; (9) the latter regime is only seen with the samples containing titanate phases; (10) the titanates seem to also aid in the oxidation at higher temperatures; and (11) in general, increasing titania crystallinity leads to a decrease the catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal radiation properties of solids at low temperatures

This paper provides introductory remarks for the symposium session on thermal ra­diation properties of solids in the range 0°-200° K. A qualitative description is given of that part of the theory that is unique to low temperatures, after which experimental methods appropriate to low temperatures and present applications of low temperature data are sketched.

SOLIDS↗

Analysis and preliminary design of optical sensors for propulsion control

A fiber-optic sensor concept screening study was performed. Twenty sensor subsystems were identified and evaluated. Two concepts selected for further study were the Fabry-Perot fiber-optic temperature sensor and the pulse-width-modulated phosphorescent temperature sensor. Various designs suitable for a Fabry-Perot temperature sensor to be used as a remote fiber-optic transducer were investigated. As a result, a particular design was selected and constructed. Tests on this device show that spectral peaks are produced from visible white light, and the change in wavelength of the spectral peaks produced by a change in temperature is consistent with theory and is 36 nm/C for the first order peak. A literature search to determine a suitable phosphor for implementing the pulse-width-modulated fiber optic temperature sensor was conducted. This search indicated that such a device could be made to function for temperatures up to approximately 200 C. Materials like ZnCdS and ZnSe activated with copper will be particularly applicable to temperature sensing in the cryogenic to room temperature region. While this sensing concept is probably not applicable to jet engines, the simplicity and potential reliability make the concept highly desirable for other applications.

James, K. A.↗

NASA Marshall Space Flight Center In-Space Cryogenic Propulsion Capabilities and Applications to Human Exploration

The current focus on lunar exploration and future human missions to Mars is driving in-space propulsion system requirements toward higher performance cryogenic systems with long-duration storage and operational capabilities. Not only do these systems offer higher performance than storable propellant options, but they also enable the potential for in-situ propellant production. Future Mars transit systems are envisioned to utilize either high-thrust nuclear thermal propulsion (with liquid hydrogen propellant), or hybrid systems with both cryogenic chemical systems (likely LOX/CH4) for high acceleration maneuvers and nuclear electric systems for long duration high Isp maneuvers. Exploration architectures based on either of these options require the use of high-performance cryogenic propellants with long-duration storage capabilities for both in-space transportation as well as planetary descent and ascent functions. Current efforts focusing on lunar exploration also rely on cryogenic propellants (either LOX/LCH4 or LOX/LH2) for lunar transit and descent/ascent transportation functions. In-space cryogenic propulsion systems pose numerous technology challenges with respect to long-duration propellant storage and usage, including advanced insulation, tank stratification and pressure management, cryogenic refrigeration to reduce propellant loss through boil off, low leakage cryogenic valves, low temperature liquid acquisition, and cryogenic propellant transfer. NASA has invested in technology development efforts, demonstrating individual technologies and systems-level operations. NASA Marshal Space Flight Center has also invested in multiple test facilities and modular test rigs that allow ground demonstration of numerous integrated technologies and systems concepts of operations. Additional investments have been made to mature analytical capabilities and design tools. These capabilities, both test/demonstration & engineering design/analysis, are available to support internal efforts and industrial partners in the development of exploration and science mission systems. With this increased interest, it is critical to understand the current state of in-space cryogenic propulsion technology, determine risks to its successful application to human exploration, and prepare the engineering, test, and evaluation capabilities to support the ambitious plans for future systems. This paper provides a survey of recent developments in in-space cryogenic propulsion and cryogenic propellant management technologies, as well as facilities and engineering/analytical capabilities ready to support current and future exploration efforts.

Cryogenic propulsion, cryogenic fluid management, ↗

NASA Marshall Space Flight Center In-Space Cryogenic Propulsion Capabilities and Applications to Human Exploration

The current focus on lunar exploration and future human missions to Mars is driving in-space propulsion system requirements toward higher performance cryogenic systems with long-duration storage and operational capabilities. Not only do these systems offer higher performance than storable propellant options, but they also enable the potential for in-situ propellant production. Future Mars transit systems are envisioned to utilize either high-thrust nuclear thermal propulsion (with liquid hydrogen propellant), or hybrid systems with both cryogenic chemical systems (likely LOX/CH 4 ) for high acceleration manoeuvres and nuclear electric systems for long duration high Isp manoeuvres. Exploration architectures based on either of these options require the use of high-performance cryogenic propellants with long-duration storage capabilities for both in-space transportation as well as planetary descent and ascent functions. Current efforts focusing on lunar exploration also rely on cryogenic propellants (either LOX/LCH 4 or LOX/LH 2 ) for lunar transit and descent/ascent transportation functions. In-space cryogenic propulsion systems pose numerous technology challenges with respect to long-duration propellant storage and usage, including advanced insulation, tank stratification and pressure management, cryogenic refrigeration to reduce propellant loss through boil off, low leakage cryogenic valves, low temperature liquid acquisition, and cryogenic propellant transfer. NASA has invested in technology development efforts, demonstrating individual technologies and systems-level operations. NASA Marshal Space Flight Center has also invested in multiple test facilities and modular test rigs that allow ground demonstration of numerous integrated technologies and systems concepts of operations. Additional investments have been made to mature analytical capabilities and design tools. These capabilities (both test/demonstration & engineering design/analysis) are available to support both internal efforts and industrial partners in the development of exploration and science mission systems. With this increased interest, it is critical to understand the current state of in-space cryogenic propulsion technology, determine risks to its successful application to human exploration, and prepare the engineering, test, and evaluation capabilities to support the ambitious plans for future systems. This paper provides a survey of recent developments in in-space cryogenic propulsion and cryogenic propellant management technologies, as well as facilities and engineering/analytical capabilities ready to support current and future exploration efforts.

Cryogenic propulsion↗