Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Tracking Synthetic Particle Paths Generated in GATE with Multi-Positron Emission Particle Tracking (MPEPT)

Multi-Positron Emission Particle Tracking (MPEPT) is able to reconstruct the position of point-sources in a PET scanner to a high degree of accuracy. Experimental and simulated trajectories of activated point-sources are compared herein to validate the GATE model of our PET scanner, and test MPEPT performance. The trajectory followed by one point-source of activity 370000 Bq is simulated in GATE, and experimentally measured for velocities 0.18, 0.22. and 0.45 cm/s moving along the major axis of the detector bore. The average difference between the prescribed and predicted point-source positions is found to be approximately 0.3 mm. However, the number of Lines of Response (LOR) reported by GATE for the 370000 Bq source is larger than the number of LOR measured in the experiments. Additional testing of the accuracy of MPEPT is provided by the simulation of 20 point-sources of 20 Bq each placed around the surface of a sphere of radius 40 mm and moving radially inward to a radius of 20 mm at a constant velocity of 1 E-6 m/s. Point-source trajectories for the GATE simulation are compared to trajectories reconstructed from the GATE generated LOR using MPEPT. The average difference between prescribed and predicted point-source position is found to be approximately 0.72 mm. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Analysis Guidance in Safety Software Validation

Quantitative analysis in software development has been a challenging topic over the years in safety software. While qualitative processes for vigorous safety software verification and validation (V and V) have been provided through standard such as IEEE 1012, quantitative analysis for V and V tasks such as correctness, completeness or accuracy evaluation have not been formally defined. In practice, there are quantitative analyses in terms of using software metrics. Many of these software metrics are useful in analyzing the test results. Some of them are used for providing guidance in code evaluation activities e.g. numbers of line of codes not exceeding certain limits, recursive calls are not allowed, etc. However, few can be used for providing quantitative analysis guidance for the V and V tasks such as completeness evaluation. AREVA Federal Services (AFS) has provided services for many nuclear projects in US. Through compliance with IEEE 1012, AFS V and V processes have provided vigorous qualitative processes ensuring quality level of the software products used in the project meeting the required nuclear software level. In addition, quantitative analysis is developed to provide structured validation framework ensuring 'zero defect' in the software products. This paper describes some aspects of the quantitative approaches using a sample safety application. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dead-Time Correction of Pulsed Neutron Source Experiments with the Backward Extrapolation Method

This paper introduces a novel procedure to correct pulsed neutron source experimental data for dead-time effects. The procedure is based on the application of the backward extrapolation method to the reaction rate value in each time interval (bin) of the neutron counts distribution as a function of time. The theoretical framework has been successfully applied to the experimental data (timestamps) from the YALINA Thermal facility driven by a pulsed D-D neutron source. Dead-time effects may have more than 500 pcm (1 pcm=1 E-5) impact on the effective multiplication factor calculated by the area method. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of Impedance Void Meter Performance in Two-Phase Flow Measurement

Over the past sixty years, exclusive work has been done on two-phase flow measurement and plenty of measurement methods have been developed. Among them, impedance void meter is considered to be a simple instrument with a quick and reliable response. Impedance measurement technique in two-phase flow has existed for more than five decades. Impedance void meter consists of two electrodes flush mounted on the flow channel which allows measurements to be performed over the entire flow area. In principle, impedance void meter is based on the different electrical conductance of water and air. The two electrodes connected with cable and voltage supplies and the air-water mixture between them form a complete circuit. The change of gas fraction occupied in the flow area is reflected by the change of impedance in this part, and then the change of the voltage signal of the circuit. Using the relationship between void fraction and voltage signal, area averaged void fraction can be measured. In a previous study by Bolman et al., the flow pattern was found that has an effect on the performance of the impedance void meter. This is due to the difference of the flow structure that affects the impedance of the flow area. Olsen suggested that the impedance void meter should fulfill the following factors in order to get good measurement results: gas phase is finely dispersed in the measuring flow area; the channel cross section should be uninterrupted; there should be several bubble diameters between sources of current. For pipe measurement, it is impossible to meet all these requirement. In this case, it is necessary to use other independent void fraction measurement methods to calibrate impedance void meter. However, the calibration result varies for different flow patterns; thus for those situations in which identifying the flow pattern is difficult, the results may not be reliable. The possible solution should be found in an aspect of impedance void meter design itself. Much work has been done focusing on the geometric design of impedance void meters. This study found that the distance between the two electrodes of the impedance void meter has an effect on the measurement performance. The primary focus of this study is to characterize the performance and measurement range of an impedance void meter in regards to its geometry aspect. In order to achieve this goal, a sensitivity study of the electrode distance was performed by numerical simulation. Based on the simulation results, an experiment was performed using an impedance void meter with different electrode distances. Additionally, a gamma densitometer and a multi single-sensor conductivity probe were also applied for the measurement comparison. Drift flux model was also used for the experimental results comparison. (authors)

42 ENGINEERING↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of the GaAs displacement damage metric using updated nuclear data

The emerging use of the physics-based athermal recombination-corrected displacement per atom (arc-dpa) model for the displacement damage efficiency has motivated a re-evaluation of the historical empirically-derived GaAs damage response function with the purpose of highlighting needs for future analytical and experimental work. The 1-MeV neutron damage equivalence methodology used in the ASTM E-722 standard for GaAs has been re-evaluated using updated nuclear data. This yielded a higher fidelity representation of the GaAs displacement kerma and, through the use of the refined PKA recoil energy-dependent damage efficiency model, an updated 1-MeV(GaAs) displacement damage function. This re-evaluation included use of the Norgett-Robinson-Torrens (NRT) model for an updated threshold treatment, rather than the sharp-threshold Kinchin-Pease model used in the current ASTM standard. The underlying nuclear data evaluations have been updated to use the ENDF/VIII.0 {sup 75}As and TENDL-2019 {sup 71}Ga/{sup 69}Ga evaluations. The displacement kerma and 1-MeV-equivalent damage responses were calculated using a modified NJOY-2016 code which allowed for refinements in some of the damage models. This paper shows that an updated displacement damage function, based upon the latest nuclear data, is consistent with the experimental data used to develop the current ASTM E-722 GaAs standard. Using a double ratio approach to compare the available experimental data with the calculated response, the average legacy double ratio was found to be 0.97 ± 0.05 and the average updated double ratio was found to be 0.94 ± 0.05. (authors)

36 MATERIALS SCIENCE↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Reactor System Safety: A case for New and Advanced Reactors

This presentation covers a generic overview of reactor system safety testing, analysis, and related research and development (R&D) focusing on new and advanced reactor systems. This presentation is prepared for graduate-level student seminar talks. No specific reactor design information is provided. Only publicly available information and related published articles and book contents are utilized.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Criticality Accident Alarm System Modeling with SCALE

Criticality accident alarm systems (CAAS) can be difficult to analyze since they consist of both criticality calculations and deep-penetration radiation transport calculations. Radiation transport codes are typically optimized for one of those two aspects but not both. A three-dimensional CAAS modeling capability within SCALE 6 has been created by linking the KENO-VI criticality code to the MAVRIC shielding sequence. KENO-VI has been optimized for criticality calculations and used for over 20 years. MAVRIC is a new sequence in SCALE 6 designed for radiation transport in deep-penetration problems. MAVRIC contains features such as automated variance reduction and mesh tally capabilities, which are quite useful in CAAS modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Characterization of Nuclear Material at Idaho National Laboratory

A measurement plan and preliminary Monte Carlo simulations are presented for the investigation of well-defined mixed-oxide fuel pins. Measurement analysis including pulse-height distributions and time-dependent cross-correlation functions will be performed separately for neutrons and gamma rays. The utilization of Monte Carlo particle transport codes, specifically MCNP-PoliMi, is discussed in conjunction with the anticipated measurements. Four EJ-309 liquid scintillation detectors with an accurate pulse timing and digital, offline, optimized pulse-shape discrimination method will be used to prove the dependency of pulse-height distributions, cross-correlation functions, and material multiplicities upon fuel pin composition, fuel pin quantity, and detector geometry. The objective of the measurements and simulations is to identify novel methods for describing mixed-oxide fuel samples by relating measured quantities to fuel characteristics such as criticality, mass quantity, and material composition. This research has applications in nuclear safeguards and nonproliferation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Cibola flight experiment

The Cibola Flight Experiment (CFE) is an experimental small satellite carrying a reconfigurable processing instrument developed at the Los Alamos National Laboratory that demonstrates the feasibility of using FPGA-based high-performance computing for sensor processing in the space environment. The CFE satellite was launched on March 8, 2007 in low-earth orbit and has operated extremely well since its deployment. The nine Xilinx Virtex FPGAs used in the payload have been used for several high-throughput sensor processing applications and for single-event upset (SEU) monitoring and mitigation. This paper will describe the CFE system and summarize its operational results. In addition, this paper will describe the results from several SEU detection circuits that were performed on the spacecraft.

97 MATHEMATICS AND COMPUTING↗

Modeling of x-ray fluorescence using MCNPX and Geant4

X-Ray Fluorescence (XRF) is one of thirteen non-destructive assay techniques being researched for the purpose of quantifying the Pu mass in used fuel assemblies. The modeling portion of this research will be conducted with the MCNPX transport code. The research presented here was undertaken to test the capability of MCNPX so that it can be used to benchmark measurements made at the ORNL and to give confidence in the application of MCNPX as a predictive tool of the expected capability of XRF in the context of used fuel assemblies. The main focus of this paper is a code-to-code comparison between MCNPX and Geant4 code. Since XRF in used fuel is driven by photon emission and beta decay of fission fragments, both terms were independently researched. Simple cases and used fuel cases were modeled for both source terms. In order to prepare for benchmarking to experiments, it was necessary to determine the relative significance of the various fission fragments for producing X-rays.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rad-Hard SBC: Radiation-Hardened Single-Board Computer

As global reliance on satellites and their services increases, scientists and engineers will continue to feel pressure to reduce costs, save power, and reduce size and weight. Los Alamos researchers have developed the Rad-Hard SBC to alleviate this pressure. The invention is a radiation- and mechanically-hardened single-board computer that is small, lightweight, and uses less power than any commercially available space-grade computer. Rad-Hard SBC provides an affordable option for long-lasting satellites beyond low-Earth orbits. The computer enables researchers, businesses, and consumers broader access to space assets for their unique needs. The invention builds on the Lab's more than fifty years of experience in designing, manufacturing, and deploying instruments for use on satellites and deep space missions. A R&D 100 Award has recognized the innovation and value of the Rad-Hard SBC.

42 ENGINEERING↗

Simulation for Iron Calorimeter prototype detector of India-based Neutrino Observatory

The India-based Neutrino Observatory (INO) collaboration is proposing to build a 50 kton magnetized iron calorimeter (ICAL) detector in an underground laboratory to be located in South India. As a first step towards building the ICAL detector, a 35 ton prototype of the same design has been set up on the surface to track cosmic ray muons. This paper discusses the prototype detector geometry simulation by GEANT4, and the detector response to the cosmic muons. We have developed a track fitting procedure based on the Kalman Filter technique for the prototype detector when the detector is exposed to single muon tracks. The relevant track parameters i.e., momentum, direction and charge are reconstructed and analyzed. Finally we show the resolution of reconstructed momenta.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optoacoustic Microscopy for Investigation of Material Nanostructures-Embracing the Ultrasmall, Ultrafast, and the Invisible

The goal of this grant was the development of a new type of scanning acoustic microscope for nanometer resolution ultrasound imaging, based on ultrafast optoacoustics (>GHz). In the microscope, subpicosecond laser pulses was used to generate and detect very high frequency ultrasound with nanometer wavelengths. We report here on the outcome of the 3-year DOE/BES grant which involved the design, multifaceted construction, and proof-of-concept demonstration of an instrument that can be used for quantitative imaging of nanoscale material features – including features that may be buried so as to be inaccessible to conventional lightwave or electron microscopies. The research program has produced a prototype scanning optoacoustic microscope which, in combination with advanced computational modeling, is a system-level new technology (two patents issues) which offer novel means for precision metrology of material nanostructures, particularly those that are of contemporary interest to the frontline micro- and optoelectronics device industry. For accomplishing the ambitious technical goals, the research roadmap was designed and implemented in two phases. In Phase I, we constructed a “non-focusing” optoacoustic microscope instrument (“POAM”), with nanometer vertical (z-) resolution, while limited to approximately 10 micrometer scale lateral recolution. The Phase I version of the instrument which was guided by extensive acoustic and optical numerical modeling of the basic underlying acoustic and optical physics, featured nanometer scale close loop positioning between the optoacoustic transducer element and a nanostructured material sample under investigation. In phase II, we implemented and demonstrated a scanning version of the instrument (“SOAM”) where incident acoustic energy is focused, and scanned on lateral (x-y) spatial scale in the 100 nm range as per the goals of the project. In so doing we developed advanced numerical simulations to provide computational models of the focusing of multi-GHz acoustic waves to the nanometer scale and innovated a series fabrication approaches for a new type of broadband high-frequency acoustic focusing microscope objective by applying methods on nanoimprinting and focused-ion beam techniques. In the following, the Phase I and Phase II instrument development is reported as Section II. The first segment of this section describes the POAM instrument and its development, while including much of the underlying ultrafast acoustic physics which is common to all of our work for this grant. Then, the science and engineering of the SOAM instrument is described, including the methods of fabricating new types of acoustic microlenses. The results section is followed by reports on publications (Section III), Participants (Section IV), and statement of full use of the allocated grant funds (Section V).

36 MATERIALS SCIENCE↗

3D localization of electrophysiology catheters from a single x-ray cone-beam projection

Purpose: X-ray images allow the visualization of percutaneous devices such as catheters in real time but inherently lack depth information. The provision of 3D localization of these devices from cone beam x-ray projections would be advantageous for interventions such as electrophysiology (EP), whereby the operator needs to return a device to the same anatomical locations during the procedure. A method to achieve real-time 3D single view localization (SVL) of an object of known geometry from a single x-ray image is presented. SVL exploits the change in the magnification of an object as its distance from the x-ray source is varied. The x-ray projection of an object of interest is compared to a synthetic x-ray projection of a model of said object as its pose is varied. Methods: SVL was tested with a 3 mm spherical marker and an electrophysiology catheter. The effect of x-ray acquisition parameters on SVL was investigated. An independent reference localization method was developed to compare results when imaging a catheter translated via a computer controlled three-axes stage. SVL was also performed on clinical fluoroscopy image sequences. A commercial navigation system was used in some clinical image sequences for comparison. Results: SVL estimates exhibited little change as x-ray acquisition parameters were varied. The reproducibility of catheter position estimates in phantoms denoted by the standard deviations, (σ{sub x}, σ{sub y}, σ{sub z}) = (0.099 mm, 0.093 mm, 2.2 mm), where x and y are parallel to the detector plane and z is the distance from the x-ray source. Position estimates (x, y, z) exhibited a 4% systematic error (underestimation) when compared to the reference method. The authors demonstrated that EP catheters can be tracked in clinical fluoroscopic images. Conclusions: It has been shown that EP catheters can be localized in real time in phantoms and clinical images at fluoroscopic exposure rates. Further work is required to characterize performance in clinical images as well as the sensitivity to clinical image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-Based Upgrades to Observational Data Centers to Facilitate Data Interoperability

Focal Areas: (1) Data acquisition and assimilation enabled by machine learning, AI, and advanced methods including experimental/network design/optimization, unsupervised learning (including deep learning), and hardware-related efforts involving AI (e.g., edge computing). Focal areas 2 and 3 have critical dependencies to the modernization described. Key benefits to the focal areas: (1) Modernized observatory framework capable of agile adaptive observation, (2) Advanced instrument and data tagging supporting AI data acquisition for assimilation or validation, and (3) Widespread data interoperability bridging Earth system prediction scales

54 ENVIRONMENTAL SCIENCES↗