Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Broadband Outdoor Radiometer Calibration (BORCAL) Process for the Atmospheric Radiation Measurement (ARM) Program: Second Edition

The Atmospheric Radiation Measurement program (ARM) maintains a fleet of monitoring stations to aid in the improved scientific understanding of the basic physics related to radiative feedback processes in the atmosphere, particularly the interactions among clouds and aerosols. ARM obtains continuous measurements and conducts field campaigns to provide data products that aid in the improvement and further development of climate models. All of the measurement campaigns include a suite of solar measurements. The Solar Radiation Research Laboratory at the National Renewable Energy Laboratory supports ARM's full suite of stations in a number of ways, including troubleshooting issues that arise as part of the data-quality reviews; managing engineering changes to the standard setup; and providing calibration services and assistance to the full fleet of solar-related instruments, including pyranometers, pyrgeometers, pyrheliometers, as well as the temperature/relative humidity probes, multimeters, and data acquisition systems that are used in the calibrations performed at the Southern Great Plains Radiometer Calibration Facility. This paper discusses all aspects related to the support provided to the calibration of the instruments in the solar monitoring fleet.

14 SOLAR ENERGY↗

INL CRMO XRF Special Report No. 3: INL CRMO XRF Calibration Methods for the Analysis of Ceramics and Brick

This report details the analytical methods used by the Idaho National Laboratory Cultural Resource Management Office to characterize ceramic and brick artifacts using X-ray fluorescence spectrometry. More specifically, this report provides details on instrumentation, analysis times, and matrix-specific calibration protocols for ceramic materials. Calibration curves were developed to adjust raw instrumental output for 13 elements using a suite of reference standards made from historic brick borrowed from the Yale Peabody Museum. Calibration curves were validated by plotting predicted values against published reference values for the calibration set as well as a certified soil reference standard (SRM 2711a).

36 MATERIALS SCIENCE↗

New Strategies for Time Delay Estimation during System Calibration for UAV-Based GNSS/INS-Assisted Imaging Systems

The need for accurate 3D spatial information is growing rapidly in many of today’s key industries, such as precision agriculture, emergency management, infrastructure monitoring, and defense. Unmanned aerial vehicles (UAVs) equipped with global navigation satellite systems/inertial navigation systems (GNSS/INS) and consumer-grade digital imaging sensors are capable of providing accurate 3D spatial information at a relatively low cost. However, with the use of consumer-grade sensors, system calibration is critical for accurate 3D reconstruction. In this study, ‘consumer-grade’ refers to cameras that require system calibration by the user instead of by the manufacturer or other high-end laboratory settings, as well as relatively low-cost GNSS/INS units. In addition to classical spatial system calibration, many consumer-grade sensors also need temporal calibration for accurate 3D reconstruction. This study examines the accuracy impact of time delay in the synchronization between the GNSS/INS unit and cameras on-board UAV-based mapping systems. After reviewing existing strategies, this study presents two approaches (direct and indirect) to correct for time delay between GNSS/INS recorded event markers and actual time of image exposure. Our results show that both approaches are capable of handling and correcting this time delay, with the direct approach being more rigorous. When a time delay exists and the direct or indirect approach is applied, horizontal accuracy of 1–3 times the ground sampling distance (GSD) can be achieved without either the use of any ground control points (GCPs) or adjusting the original GNSS/INS trajectory information.

47 OTHER INSTRUMENTATION↗

THE CARMA PAIRED ANTENNA CALIBRATION SYSTEM: ATMOSPHERIC PHASE CORRECTION FOR MILLIMETER WAVE INTERFEROMETRY AND ITS APPLICATION TO MAPPING THE ULTRALUMINOUS GALAXY ARP 193

Phase fluctuations introduced by the atmosphere are the main limiting factor in attaining diffraction limited performance in extended interferometric arrays at millimeter and submillimeter wavelengths. We report the results of C-PACS, the Combined Array for Research in Millimeter-Wave Astronomy Paired Antenna Calibration System. We present a systematic study of several hundred test observations taken during the 2009–2010 winter observing season where we utilize CARMA's eight 3.5 m antennas to monitor an atmospheric calibrator while simultaneously acquiring science observations with 6.1 and 10.4 m antennas on baselines ranging from a few hundred meters to ∼2 km. We find that C-PACS is systematically successful at improving coherence on long baselines under a variety of atmospheric conditions. We find that the angular separation between the atmospheric calibrator and target source is the most important consideration, with consistently successful phase correction at CARMA requiring a suitable calibrator located ≲6° away from the science target. We show that cloud cover does not affect the success of C-PACS. We demonstrate C-PACS in typical use by applying it to the observations of the nearby very luminous infrared galaxy Arp 193 in {sup 12}CO(2-1) at a linear resolution of ≈70 pc (0.″12 × 0.″18), 3 times better than previously published molecular maps of this galaxy. We resolve the molecular disk rotation kinematics and the molecular gas distribution and measure the gas surface densities and masses on 90 pc scales. We find that molecular gas constitutes ∼30% of the dynamical mass in the inner 700 pc of this object with a surface density ∼10{sup 4} M{sub ⊙} pc{sup −2}; we compare these properties to those of the starburst region of NGC 253.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the Voyager ultraviolet spectrometers and the composition of the heliosphere neutrals: reassessment

The data harvest from the Voyagers’ (V 1 and V 2) Ultraviolet Spectrometers (UVS) covers encounters with the outer planets, measurements of the heliosphere sky-background, and stellar spectrophotometry. Because their period of operation overlaps with many ultraviolet missions, the calibration of V1 and V2 UVS with other spectrometers is invaluable. Here we revisit the UVS calibration to assess the intriguing sensitivity enhancements of 243% (V1) and 156% (V2) proposed recently. Using the Lyα airglow from Saturn, observed in situ by both Voyagers, and remotely by International Ultraviolet Explorer (IUE), we match the Voyager values to IUE, taking into account the shape of the Saturn Lyα line observed with the Goddard High Resolution Spectrograph on board the Hubble Space Telescope. For all known ranges of the interplanetary hydrogen density, we show that the V1 and V2 UVS sensitivities cannot be enhanced by the amounts thus far proposed. The same diagnostic holds for distinct channels covering the diffuse He i 58.4 nm emission. Our prescription is to keep the original calibration of the Voyager UVS with a maximum uncertainty of 30%, making both instruments some of the most stable EUV/FUV spectrographs in the history of space exploration. In that frame, we reassess the excess Lyα emission detected by Voyager UVS deep in the heliosphere, to show its consistency with a heliospheric but not galactic origin. Our finding confirms results obtained nearly two decades ago—namely, the UVS discovery of the distortion of the heliosphere and the corresponding obliquity of the local interstellar magnetic field (∼40{sup ∘} from upwind) in the solar system neighborhood—without requiring any revision of the Voyager UVS calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

An Eigenvector-Based Method of Radio Array Calibration and Its Application to the Tianlai Cylinder Pathfinder

We propose an eigenvector-based formalism for the calibration of radio interferometer arrays. In the presence of a strong dominant point source, the complex gains of the array can be obtained by taking the first eigenvector of the visibility matrix. We use the stable principle component analysis method to help separate outliers and noise from the calibrator signal to improve the performance of the method. This method can be applied with poorly known beam model of the antenna, is insensitive to outliers or imperfections in the data, and has low computational complexity. It thus is particularly suitable for the initial calibration of the array, which can serve as the initial point for more accurate calibrations. We demonstrate this method by applying it to the cylinder pathfinder of the Tianlai experiment, which aims to measure the dark energy equation of state using the baryon acoustic oscillation features in the large-scale structure by making intensity mapping observation of the redshifted 21 cm emission of the neutral hydrogen (H i). The complex gain of the array elements and the beam profile in the east–west direction (short axis of the cylinder) are successfully obtained by applying this method to the transit data of bright radio sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Spitzer IRAC Photometry of JWST Calibration Stars

We present infrared photometry of all 36 potential JWST calibrators for which there is archival Spitzer IRAC data. This photometry can then be used to inform the stellar models necessary to provide absolute calibration for all JWST instruments. We describe in detail the steps necessary to measure IRAC photometry from archive retrieval to photometric corrections. To validate our photometry, we examine the distribution of uncertainties from all detections in all four IRAC channels as well as compare the photometry and its uncertainties to those from models, ALLWISE, and the literature. Seventy-five percent of our detections have standard deviations per star of all observations within each channel of less than 3%. The median standard deviations are 1.2%, 1.3%, 1.1%, and 1.9% in [3.6]–[8.0], respectively. We find less than 8% standard deviations in differences of our photometry with ALLWISE and excellent agreement with literature values (less than 3% difference), lending credence to our measured fluxes. JWST is poised to do groundbreaking science, and accurate calibration and cross-calibration with other missions will be part of the underpinnings of that science.

47 OTHER INSTRUMENTATION↗

Insights from Synthetic Star-forming Regions. III. Calibration of Measurement and Techniques of Star Formation Rates

Through an extensive set of realistic synthetic observations (produced in Paper I), we assess in this part of the paper series (Paper III) how the choice of observational techniques affects the measurement of star formation rates (SFRs) in star-forming regions. We test the accuracy of commonly used techniques and construct new methods to extract the SFR, so that these findings can be applied to measure the SFR in real regions throughout the Milky Way. We investigate diffuse infrared SFR tracers such as those using 24 μ m, 70 μ m and total infrared emission, which have been previously calibrated for global galaxy scales. We set up a toy model of a galaxy and show that the infrared emission is consistent with the intrinsic SFR using extra-galactic calibrated laws (although the consistency does not prove their reliability). For local scales, we show that these techniques produce completely unreliable results for single star-forming regions, which are governed by different characteristic timescales. We show how calibration of these techniques can be improved for single star-forming regions by adjusting the characteristic timescale and the scaling factor and give suggestions of new calibrations of the diffuse star formation tracers. We show that star-forming regions that are dominated by high-mass stellar feedback experience a rapid drop in infrared emission once high-mass stellar feedback is turned on, which implies different characteristic timescales. Moreover, we explore the measured SFRs calculated directly from the observed young stellar population. We find that the measured point sources follow the evolutionary pace of star formation more directly than diffuse star formation tracers.

79 ASTRONOMY AND ASTROPHYSICS↗

The Complete Calibration of the Color–Redshift Relation (C3R2) Survey: Survey Overview and Data Release 1

A key goal of the Stage IV dark energy experiments Euclid , LSST, and WFIRST is to measure the growth of structure with cosmic time from weak lensing analysis over large regions of the sky. Weak lensing cosmology will be challenging: in addition to highly accurate galaxy shape measurements, statistically robust and accurate photometric redshift (photo- z ) estimates for billions of faint galaxies will be needed in order to reconstruct the three-dimensional matter distribution. Here we present an overview of and initial results from the Complete Calibration of the Color–Redshift Relation (C3R2) survey, which is designed specifically to calibrate the empirical galaxy color–redshift relation to the Euclid depth. These redshifts will also be important for the calibrations of LSST and WFIRST . The C3R2 survey is obtaining multiplexed observations with Keck (DEIMOS, LRIS, and MOSFIRE), the Gran Telescopio Canarias (GTC; OSIRIS), and the Very Large Telescope (VLT; FORS2 and KMOS) of a targeted sample of galaxies that are most important for the redshift calibration. We focus spectroscopic efforts on undersampled regions of galaxy color space identified in previous work in order to minimize the number of spectroscopic redshifts needed to map the color–redshift relation to the required accuracy. We present the C3R2 survey strategy and initial results, including the 1283 high-confidence redshifts obtained in the 2016A semester and released as Data Release 1.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the Total Carbon Column Observing Network using Aircraft Profile Data

The Total Carbon Column Observing Network (TCCON) produces precise measurements of the column average dry-air mole fractions of CO{sub 2}, CO, CH{sub 4}, N{sub 2}O and H{sub 2}O at a variety of sites worldwide. These observations rely on spectroscopic parameters that are not known with sufficient accuracy to compute total columns that can be used in combination with in situ measure ments. The TCCON must therefore be calibrated to World Meteorological Organization (WMO) in situ trace gas measurement scales. We present a calibration of TCCON data using WMO-scale instrumentation aboard aircraft that measured profiles over four TCCON stations during 2008 and 2009. The aircraft campaigns are the Stratosphere-Troposphere Analyses of Regional Transport 2008 (START-08), which included a profile over the Park Falls site, the HIAPER Pole-to-Pole Observations (HIPPO-1) campaign, which included profiles over the Lamont and Lauder sites, a series of Learjet profiles over the Lamont site, and a Beechcraft King Air profile over the Tsukuba site. These calibrations are compared with similar observations made during the INTEX-NA (2004), COBRA-ME (2004) and TWP-ICE (2006) campaigns. A single, global calibration factor for each gas accurately captures the TCCON total column data within error.

54 ENVIRONMENTAL SCIENCES↗

Model Calibration with Markov Chain Monte Carlo Tutorial

The purpose of this tutorial is to demonstrate how to use Markov chain Monte Carlo (MCMC) to calibrate a model. By calibration, we mean the selection of model parameters (and, when relevant, structures). A common goal in model development and diagnostics is calibration, or the identification of model structures and parameters which are consistent with data. While models can be calibrated through hand-tuning parameters or minimizing simple error metrics such as root-mean-square-error (RMSE), these approaches can underrepresent the probabilistic nature of the data-generating process, as well as the potential for multiple model configurations to be consistent with the data. Probabilistic uncertainty quantification, which is the topic of this notebook, can address these concerns. This tutorial is presented as an appendix to the e-book: Addressing Uncertainty in MultiSector Dynamics Research.

Markov chain Monte Carlo↗

(abstract) Radiometric Calibration of the Multi-angle Imaging Spectro-Radiometer

The EOS/MISR instrument has completed preflight calibration and characterization of its nine cameras. The radiometric calibration requirements includes absolute radiometric accuracy to 3 percent. To meet this challenging requirement MISR has employed detector based calibration methodology. The source, a 1.65 m integrating sphere, is spatially and spectrally featureless. Thus, when viewing scenes that are likewise homogeneous, the sensor incident radiance is easily retrieved to high accuracy. To enhance the radiance product for arbitrary scene types, however, MISR is planning to incorporate spectral out-of-band, point-spread function deconvolution, and pixel nonuniformity of response corrections. A summary of the preflight calibration is presented in this paper, as well as the error uncertainties for specific scene types with and without these processing corrections.

radiometric calibration EOS MISR↗

Design and Field-of-View Calibration of 114-660-GHz Optics of the Earth Observing System Microwave Limb Sounder

This paper describes the optics design and field-of view (FOV) calibration for five radiometers covering 114-660 GHz which share a common antenna in the Microwave Limb Sounder instrument on the National Aeronautics and Space Administration's Aura satellite. Details of near-field pattern measurements are presented. Estimated systematic scaling uncertainties (3/spl sigma/) on calibrated limb emissions, due to FOV calibration uncertainties, are below 0.4%. 3/spl sigma/ uncertainties in beamwidth and relative pointing of radiometer boresights are 0.006A(deg) and 0.003A(deg) , respectively. The uncertainty in modeled instrument response, due to the scan dependence of FOV patterns, is less than +/- 0.24 K equivalent blackbody temperature. Refinements to the calibration using in-flight data are presented.

Calibration↗

On-Orbit Maneuver Calibrations for the Stardust Spacecraft

The Stardust spacecraft, launched February 7, 1999, successfully delivered its sample return capsule to the Utah Test and Training Range on January 15, 2006. The entry maneuver strategy included a trajectory correction at entry minus 10 days (TCM18) targeted to entry with the inclusion of a final biased fixed direction maneuver at entry minus 29 hours (TCM19). To meet the stringent entry targeting requirements necessary for human safety and capsule integrity, a campaign of maneuver calibrations were undertaken in summers of 2003 and 2005 to improve performance for both maneuvers. The results of the calibration program are reported here. The in-flight calibrations included a series of several turns to various final attitudes via deadband walks about each of the three spacecraft axes, as well as 12 in-place burns with magnitudes between 0.5 and 1.0 m/s, the range initially expected for TCM19. The turn and burn calibrations as well as the performance of TCM 17, 18 and 19 are discussed.

maneuver↗

Landsat TM and ETM+ Thermal Band Calibration

Landsat-5 Thematic Mapper (TM) has been imaging the Earth since March 1984 and Landsat-7 Enhanced Thematic Mapper Plus (ETM+) was added to the series of Landsat instruments in April 1999. The stability and calibration of the ETM+ has been monitored extensively since launch. Though not monitored for many years, TM now has a similar system in place to monitor stability and calibration. University teams have been evaluating the on-board calibration of the instruments through ground-based measurements since 1999. This paper considers the calibration efforts for the thermal band, Band 6, of both the Landsat-5 and Landsat-7 instruments.

Thematic Mapper (TM)↗

Challenges of In-Flight Calibrations for the Mars Reconnaissance Orbiter Payload

The Mars Reconnaissance Orbiter is the most complex spacecraft that has ever been sent to investigate the Red Planet. A major part of what makes this mission so complex is the suite of instruments that were selected. The instruments on MRO vary from a simple imaging system, not much larger than a pocket knife to the largest camera ever flown to another planet. Not only does the size of the instruments vary, so do the scientific investigations associated with each instrument. In order to ensure that this payload suite would be able to satisfy all of its science objectives, a major effort was put forth by the MRO Project to ensure these instruments were well calibrated prior to the start of the Primary Science Phase. The in-flight calibration plan for MRO proved to be quite challenging, given the often conflicting requirements due to the varying capability of each of the instruments and the desire to constrain the workload on the Mission Operations personnel. The quality of data returned by MRO since the start of the Primary Science Phase is a tribute to the effort that was put forth to characterize the in-flight performance of the instruments. This paper will describe the challenges associated with the planning and implementation of the various calibration events on MRO, and will exhibit some of the results from those calibrations.

Mars Reconnaissance Orbiter (MRO)↗

Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation

Cosmic microwave background (CMB) polarimeters aspire to measure the faint B-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence, rotation of the polarization of the CMB arising from parity-violating physics, which would produce nonzero expectation values for the CMB's temperature to B-mode correlation (TB) and E-mode to B-mode correlation (EB) spectra. However, instrumental systematic effects can also cause these TB and EB correlations to be nonzero. In particular, an overall miscalibration of the polarization orientation of the detectors produces TB and EB spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the BB spectrum. We find that BICEP1 three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of alpha = −2.77deg +/- 0.86deg (statistical) +/- 1.3deg (systematic). We have revised the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We also account for the (negligible) impact of measured beam systematic effects. We investigate the polarization rotation for the BICEP1 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either of these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the TB and EB spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological B-mode spectrum from leaked E-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from r < 0.70 to r < 0.65 at 95% confidence.

three-year↗

NASA Glenn Icing Research Tunnel: 2014 Cloud Calibration Procedure and Results

The results of the December 2013 to February 2014 Icing Research Tunnel full icing cloud calibration are presented. The calibration steps included establishing a uniform cloud and conducting drop size and liquid water content calibrations. The goal of the calibration was to develop a uniform cloud, and to generate a transfer function from the inputs of air speed, spray bar atomizing air pressure and water pressure to the outputs of median volumetric drop diameter and liquid water content. This was done for both 14 CFR Parts 25 and 29, Appendix C ('typical' icing) and soon-to-be released Appendix O (supercooled large drop) conditions.

liquid water content↗