Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CM process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Determination of photophysical parameters of tryptophan molecules by methods of laser fluorimetry

The photophysical parameters of tryptophan molecules at a low concentration in aqueous solution are measured by the methods of nanosecond laser fluorimetry upon excitation by 266-nm laser pulses. Two-step processes (reversible and irreversible photochemical transformations) taking place in this case are described quantitatively and it is shown that they can be neglected at the exciting photon flux density F < 5x10{sup 24} cm{sup -2} s{sup -1} in {approx}10-ns pulses. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unraveling the mysteries of the Leo Ring: An absorption line study of an unusual gas cloud

Since the discovery of the large (2 × 10{sup 9} M{sub ☉}) intergalactic cloud known as the Leo Ring in the 1980s, the origin of this object has been the center of a lively debate. Determining the origin of this object is still important as we develop a deeper understanding of the accretion and feedback processes that shape galaxy evolution. We present Hubble Space Telescope/Cosmic Origins Spectrograph observations of three sightlines near the ring, two of which penetrate the high column density neutral hydrogen gas visible in 21 cm observations of the object. These observations provide the first direct measurement of the metallicity of the gas in the ring, an important clue to its origin. Our best estimate of the metallicity of the ring is ∼10% Z{sub ☉}, higher than expected for primordial gas but lower than expected from an interaction. We discuss possible modifications to the interaction and primordial gas scenarios that would be consistent with this metallicity measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (CEvNS) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer CEvNS over the background-only null hypothesis with greater than 3σ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2±0.7)×10 –39 cm 2 —consistent with the standard model prediction. In conclusion, the neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the CEvNS process and provides improved constraints on nonstandard neutrino interactions.

39 ≤ A ≤ 58↗

Etching with electron beam-generated plasmas: Selectivity versus ion energy in silicon-based films

In the ideal case, plasma-enhanced atomic layer etching enables the ability to not only remove one monolayer of material but also leave adjacent layers undamaged. This dual mandate requires fine control over the flux of species to ensure efficacy, while maintaining an often arduously low ion energy. Electron beam-generated plasmas are well-suited for etching at low ion energies as they are generally characterized by highly charged particle densities (10 10 –10 11 cm –3 ) and low electron temperatures (<1.0 eV), which provide the ability to deliver a large flux of ions whose energies are <5 eV. Raising the ion energy with substrate biasing thus enables process control over an energy range that extends down to values commensurate with the bond strength of most material systems. In this work, we discuss silicon nitride etching using pulsed, electron beam-generated plasmas produced in argon-SF6 backgrounds. We pay particular attention to the etch rates and selectivity versus oxidized silicon nitride and polycrystalline silicon as a function of ion energy from a few eV up to 50 eV. Here, we find the blanket etch rate of Si 3 N 4 to be in the range of 1 A/s, with selectivities (versus SiO 2 and poly-Si) greater than 10:1 when ion energies are below 30 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-268: Proton Radiosurgery End-To-End Testing Using Lucy 3D QA Phantom

Purpose: To check the overall accuracy of proton radiosurgery treatment delivery using ready-made circular collimator inserts and fixed thickness compensating boluses. Methods: Lucy 3D QA phantom (Standard Imaging Inc. WI, USA) inserted with GaFchromicTM film was irradiated with laterally scattered and longitudinally spread-out 126.8 MeV proton beams. The tests followed every step in the proton radiosurgery treatment delivery process: CT scan (GE Lightspeed VCT), target contouring, treatment planning (Odyssey 5.0, Optivus, CA), portal calibration, target localization using robotic couch with image guidance and dose delivery at planned gantry angles. A 2 cm diameter collimator insert in a 4 cm diameter radiosurgery cone and a 1.2 cm thick compensating flat bolus were used for all beams. Film dosimetry (RIT114 v5.0, Radiological Imaging Technology, CO, USA) was used to evaluate the accuracy of target localization and relative dose distributions compared to those calculated by the treatment planning system. Results: The localization accuracy was estimated by analyzing the GaFchromic films irradiated at gantry 0, 90 and 270 degrees. We observed 0.5 mm shift in lateral direction (patient left), ±0.9 mm shift in AP direction and ±1.0 mm shift in vertical direction (gantry dependent). The isodose overlays showed good agreement (<2mm, 50% isodose lines) between measured and calculated doses. Conclusion: Localization accuracy depends on gantry sag, CT resolution and distortion, DRRs from treatment planning computer, localization accuracy of image guidance system, fabrication of ready-made aperture and cone housing. The total deviation from the isocenter was 1.4 mm. Dose distribution uncertainty comes from distal end error due to bolus and CT density, in addition to localization error. The planned dose distribution was well matched (>90%) to the measured values 2%/2mm criteria. Our test showed the robustness of our proton radiosurgery treatment delivery system using ready-made collimator inserts and fixed thickness compensating boluses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-159: Characteristics of Fiber-Optic Radiation Sensor for Proton Therapeutic Beam

Purpose: A fiber-optic radiation sensor using Cerenkov radiation has been widely studied for use as a dosimeter for proton therapeutic beam. Although the fiber-optic radiation sensor has already been investigated for proton therapeutic, it has been examined relatively little work for clinical therapeutic proton beams. In this study, we evaluated characteristics of a fiber-optic radiation sensor for clinical therapeutic proton beams. We experimentally evaluated dose-rate dependence, dose response and energy dependence for the proton beam. Methods: A fiber-optic radiation sensor was placed in a water phantom. Beams with energies of low, middle and high were used in the passively-scattered proton therapeutic beam at the National Cancer Center in Korea. The sensor consists of two plastic optical fibers (POF). A reference POF and 2 cm longer POF were used to utilize the subtraction method for having sensitive volume. Each POF is optically coupled to the Multi-Anode Photo Multiplier Tube (MAPMT) and the MAPMT signals are processed using National Instruments Data Acquisition System (NI-DAQ). We were investigated dosimetric properties including dose-rate dependence, dose response and energy dependence. Results: We have successfully evaluated characteristics of a fiber optic radiation sensor using Cerenkov radiation. The fiber-optic radiation sensor showed the dose response linearity and low energy dependence. In addition, as the dose-rate was increased, Cerenkov radiation increased linearly. Conclusion: We evaluated the basic characteristics of the fiber optic radiation sensor, the dosimetry tool, to raise the quality of proton therapy. Based on the research, we developed a real time dosimetry system of the optic fiber to confirm the real time beam position and energy for therapeutic proton pencil beam.

60 APPLIED LIFE SCIENCES↗

In-situ measurement of pyrolysis and combustion gases from biomass burning using swept wavelength external cavity quantum cascade lasers

Broadband high-speed absorption spectroscopy using swept-wavelength external cavity quantum cascade lasers (ECQCLs) is applied to measure multiple pyrolysis and combustion gases in biomass burning experiments. Two broadly-tunable swept-ECQCL systems were used, with the first tuned over a range of 2089-2262 cm -1 (4.42 – 4.79 µm) to measure spectra of CO 2 , H 2 O, and CO. The second was tuned over a range of 920-1150 cm -1 (8.70 – 10.9 µm) to measure spectra of ammonia (NH 3 ), ethene (C 2 H 4 ), and methanol (MeOH). Absorption spectra were measured continuously at a 100 Hz rate throughout the burn process, including inhomogeneous flame regions, and analyzed to determine time-resolved gas concentrations and temperature. The results provide in-situ, dynamic information regarding gas-phase species as they are generated, close to the biomass fuel source.

09 BIOMASS FUELS↗

The RHIC Polarized Source Upgrade

The basic limitations on the high-intensity H - ion beam production were experimentally studied in charge-exchange collisions of the neutral atomic hydrogen beam in the Na- vapor jet ionizer cell. These studies are the part of the polarized source upgrade (to 10 mA peak current and 85% polarization) project for RHIC. In the source the atomic hydrogen beam of a 5-10 keV energy and total (equivalent) current up to 5 A is produced by neutralization of proton beam in pulsed hydrogen gas target. Formation of the proton beam (from the surface of the plasma emitter with a low transverse ion temperature ~0.2 eV) is produced by four-electrode spherical multi-aperture ion-optical system with geometrical focusing. The hydrogen atomic beam intensity up t o 1.0 A /cm 2 (equivalent) was obtained in the Na-jet ionizer aperture of a 2.0 cm diameter. At the first stage of the experiment H- beam with 36 mA current, 5 keV energy and ~1.0 cm·mrad normalized emittance was obtained using the flat grids and magnetic focusing. The experimental results of the high-intensity neutral hydrogen beam generation and studies of the charge-exchange polarization processes of this intense beam will be presented.

43 PARTICLE ACCELERATORS↗

Convective and Turbulent Motions in Nonprecipitating Cu. Part III: Characteristics of Turbulence Motions

Velocity field in a nonprecipitating Cu under BOMEX conditions, simulated by SAM with 10-m resolution and spectral bin microphysics is separated into the convective part and the turbulent part, using a wavelet filtering. In Part II of the study properties of convective motions of this Cu were investigated. Here in Part III of the study, the parameters of cloud turbulence are calculated in the cloud updraft zone at different stages of cloud development. The main points of this study are (i) application of a fine-scale LES model of a single convective cloud allowed a direct estimation of turbulence parameters using the resolved flow in the cloud and (ii) the separation of the resolved flow into the turbulence flow and the nonturbulence flow allowed us to estimate different turbulent parameters with sufficient statistical accuracy. We calculated height and time dependences of the main turbulent parameters such as turbulence kinetic energy (TKE), spectra of TKE, dissipation rate, and the turbulent coefficient. It was found that the main source of turbulence in the cloud is buoyancy whose contribution is described by the buoyancy production term (BPT). The shear production term (SPT) increases with height and reaches its maximum near cloud top, and so does BPT. In agreement with the behavior of BPT and SPT, turbulence in the lower cloud part (below the inversion level) is weak and hardly affects the processes of mixing and entrainment. The fact that BPT is larger than SPT determines many properties of cloud turbulence. For instance, the turbulence is nonisotropic, so the vertical component of TKE is substantially larger than the horizontal components. Another consequence of the fact that BPT is larger than STP manifests itself in the finding that the turbulence spectrum largely obeys the -11/5 Bolgiano–Obukhov scaling. The classical Kolmogorov -5/3 scaling dominates for the low part of a cloud largely at the dissolving stage of cloud evolution. Using the spectra obtained we evaluated an “effective” dissipation rate which increases with height from nearly zero at cloud base up to 20 cm 2 s -3 near cloud top. The coefficient of turbulent diffusion was found to increase with height and ranged from 5 m 2 s -1 near cloud base to 25 m 2 s -1 near cloud top. In conclusion, the possible role of turbulence in the process of lateral entrainment and mixing is discussed.

54 ENVIRONMENTAL SCIENCES↗

Dolomites in hydrated fine-grained Antarctic micrometeorites: Effective tools for analyzing secondary processes

We report detailed transmission electron microscope (TEM) observations of carbonates from one hydrated fine-grained Antarctic micrometeorite (H-FgMM). These carbonates show the occurrence of complex chemical variations and microstructures that provide important evidence regarding the formation and evolution of rarely analyzed H-FgMMs. The chemical variations were identified at both micrometer and nanometer scales, indicating that these carbonates formed under localized fluid conditions that suggest a variable chemical microenvironment. Individual carbonates grew from isolated reservoirs of fluid. Moreover, these carbonates contain manganese amounts almost twice as high as those measured in CM chondrites but similar to those identified in CI chondrites. Their particular compositions indicate reducing and progressively evolving conditions in the fluid from which these carbonates precipitated, probably due to water consumption during phyllosilicates formation. In addition to the compositional variability, microstructural features are pervasive in these carbonates, similar to those described in heavily shocked meteorites indicating that these carbonates were probably modified during shock processes after their formation. Since carbonates are highly susceptible to shock metamorphism, we suggest that it is essential to investigate their structure in detail before interpreting the isotopic measurements related to the time of their formation. Additionally, associated with carbonates, ubiquitous phosphates were identified in the micrometeorite analyzed. Future studies of these mineral associations will provide us further insight into the formation and evolution of asteroids, especially since they were both identified in the surface materials of Ryugu and Bennu.

58 GEOSCIENCES↗

Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to compare internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SWIFT AND FERMI OBSERVATIONS OF X-RAY FLARES: THE CASE OF LATE INTERNAL SHOCK

Simultaneous Swift and Fermi observations of gamma-ray bursts (GRBs) offer a unique broadband view of their afterglow emission, spanning more than 10 decades in energy. We present the sample of X-ray flares observed by both Swift and Fermi during the first three years of Fermi operations. While bright in the X-ray band, X-ray flares are often undetected at lower (optical), and higher (MeV to GeV) energies. We show that this disfavors synchrotron self-Compton processes as the origin of the observed X-ray emission. We compare the broadband properties of X-ray flares with the standard late internal shock model, and find that in this scenario, X-ray flares can be produced by a late-time relativistic (Γ > 50) outflow at radii R ∼ 10{sup 13}-10{sup 14} cm. This conclusion holds only if the variability timescale is significantly shorter than the observed flare duration, and implies that X-ray flares can directly probe the activity of the GRB central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THERMALIZATION IN GAMMA-RAY BURST JETS AND THE PEAK ENERGIES OF PHOTOSPHERIC SPECTRA

The low-energy spectral slopes of the prompt emission of most gamma-ray bursts (GRBs) are difficult to reconcile with radiatively efficient optically thin emission models irrespective of the radiation mechanism. An alternative is to ascribe the radiation around the spectral peak to a thermalization process occurring well inside the Thomson photosphere. This quasi-thermal spectrum can evolve into the observed non-thermal shape by additional energy release at moderate to small Thomson optical depths, which can readily give rise to the hard spectral tail. The position of the spectral peak is determined by the temperature and Lorentz factor of the flow in the thermalization zone, where the total number of photons carried by the jet is established. To reach thermalization, dissipation alone is not sufficient and photon generation requires an efficient emission/absorption process in addition to scattering. We perform a systematic study of all relevant photon production mechanisms searching for possible conditions in which thermalization can take place. We find that a significant fraction of the available energy should be dissipated at intermediate radii, {approx}10{sup 10} to a few Multiplication-Sign 10{sup 11} cm, and the flow there should be relatively slow: the bulk Lorentz factor could not exceed a few tens for all but the most luminous bursts with the highest E {sub pk} values. The least restrictive constraint for successful thermalization, {Gamma} {approx}< 20, is obtained if synchrotron emission acts as the photon source. This requires, however, a non-thermal acceleration deep below the Thomson photosphere transferring a significant fraction of the flow energy to relativistic electrons with Lorentz factors between 10 and 100. Other processes require bulk flow Lorentz factors of order of a few for typical bursts. We examine the implications of these results to different GRB photospheric emission models.

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication of micro-hollow fiber by electrospinning process in near-critical carbon dioxide

Electrospinning is a simple technique that has gained much attention because of its capability and feasibility in the fabrication of large quantities of fibers from polymer with diameters ranging in nano-microscale. These fibers provided high surface area to volume ratios, and it was of considerable interest for many applications, such as nanoparticle carriers in controlled release, scaffolds in tissue engineering, wound dressings, military wear with chemical and biological toxin-resistance, nanofibrous membranes or filters, and electronic sensors. Recently there has been a great deal of progress in the potential applications of hollow fibers in microfluids, photonics, and energy storage. In this work, electrospinning was conducted under high-pressure carbon dioxide (CO{sub 2}) to reduce the viscosity of polymer solution. The experiments were conducted at 313 K and ∼8.0 MPa. Polymer solution containing 5 wt% polymers which prepared in dichloromethane (DCM) with polyvinylpyrrolidone (PVP) to poly-L-lactic acid (PLLA) ratio 80:20 was used as a feed solution. The applied voltage was 15 kV and the distance of nozzle and collector was 8 cm. The morphology and structure of the fibers produced were observed using scanning electron microscopy (SEM). Under pressurized CO{sub 2}, PVP electrospun was produced without bead formation with diameter ranges of 608.50 - 7943.19 nm. These behaviors hold the potential to considerably improve devolatilization electrospinning processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we have the ability to quantitatively evaluate and track our afterloader performance for a technically challenging ERCP brachytherapy procedure.

60 APPLIED LIFE SCIENCES↗

Novel Solution Process for Fabricating Ultra-Thin-Film Absorber Layers in Fe 2 SiS 4 and Fe 2 GeS 4 Photovoltaics

Fe 2 SiS 4 and Fe 2 GeS 4 crystalline materials posses direct bandgaps of ~1.55 and ~1.4 eV respectively and an absorption coefficient larger than 10^5 cm–1; their theoretical potential as solar photovoltaic absorbers has been demonstrated. However, no solar devices that employ either Fe 2 SiS 4 or Fe 2 GeS 4 have been reported to date. In the presented work, nanoprecursors to Fe 2 SiS 4 and Fe 2 GeS 4 have been fabricated and employed to build ultra-thin-film layers via spray coating and rod coating methods. Temperature-dependent X-Ray diffraction analyses of nanoprecursors coatings show an unprecedented low temperature for forming crystalline Fe 2 SiS 4 and Fe 2 GeS 4 . Fabricating of ultra-thin-film photovoltaic devices utilizing Fe 2 SiS 4 and Fe 2 GeS 4 as solar absorber material is presented.

14 SOLAR ENERGY↗

Experimental and computational studies of the kinetics of the reaction of hydrogen peroxide with the amidogen radical

In this work, the pulsed-laser photolysis/laser-induced fluorescence method is used to study the kinetics of the reaction of NH 2 with H 2 O 2 to yield a second-order rate constant of (2.42 ± 0.55) × 10 –14 cm 3 molecule –1 s –1 at 412 K in 10–22 mbar of Ar bath gas. There are no prior measurements for comparison. To check this value and enable reliable extrapolation to other temperatures, we also compute thermal rate constants for this process over the temperature range 298–3000 K via multi-structural canonical variational transition-state theory with small-curvature multidimensional tunneling (MS-CVT/SCT). The CVT/SCT rate constants are derived using a dual-level direct dynamics approach utilizing single-point CCSD(T)-F12b/cc-pVQZ-F12 energies—corrected for core-valence and scalar relativistic effects—and M06-2X/MG3S geometries, gradients, and Hessians—for all stationary and non-stationary points along the reaction path. The multistructural method with torsional anharmonicity, based on a coupled torsional potential, is then employed to calculate correction factors for the rate constants, accounting for the comprehensive effects of torsional anharmonicity on the kinetics of this reaction system. The final MS-CVT/SCT rate constants are found to be in good agreement with our measurements and can be expressed in modified Arrhenius form as 2.13 × 10 –15 (T/298 K) 4.02 exp(–513 K/T) cm 3 molecule –1 s –1 over the temperature range of 298–3000 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-61: A Practical Process for Fabricating Passive Scatter Proton Beam Modulation Compensation Filters Using 3D Printing

Purpose: The purpose of this project was to devise a practical fabrication process for passive scatter proton beam compensation filters (CF) that is competitive in time, cost and effort using 3D printing. Methods: DICOM compensator filter files for a proton beam were generated by our Eclipse (Varian, Inc.) treatment planning system. The compensator thickness specifications were extracted with in-house software written in Matlab (MathWorks, Inc.) code and written to a text file which could be read by the Rhinoceros 5, computer-aided design (CAD) package (Robert McNeel and Associates), which subsequently generated a smoothed model in a STereoLithographic also known as a Standard Tesselation Language file (STL). The model in the STL file was subsequently refined using Netfabb software and then converted to printing instructions using Cura. version 15.02.1. for our 3D printer. The Airwolf3D, model HD2x, fused filament fabrication (FFF) 3D printer (Airwolf3D.com) was used for our fabrication system with a print speed of 150mm per second. It can print in over 22 different plastic filament materials in a build volume of 11” x 8” x 12”. We choose ABS plastic to print the 3D model of the imprint for our CFs. Results: Prints of the CF could be performed at a print speed of 70mm per second. The time to print the 3D topology for the CF for the 14 cm diameter snout of our Mevion 250 proton accelerator was less than 3 hours. The printed model is intended to subsequently be used as a mold to imprint a molten wax cylindrical to form the compensation after cooling. The whole process should be performed for a typical 3 beam treatment plan within a day. Conclusion: Use of 3D printing is practical and can be used to print a 3D model of a CF within a few hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗