Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Radiometric performance of the Voyager cameras

The Voyager Imaging Experiment provided high-quality data of Jupiter and the Galilean satellites with the two flyby trajectories in March and July of 1979. Moderately accurate radiometric measurements have been made using these data. This paper evaluates the radiometric results and describes the inflight and ground geometric and radiometric correction factors. The radiometric quantities of intensity I and geometric albedo I/F are derived, and scaling factors for each of the filters are tabulated for correcting the 'calibrated' data from the Image Processing Laboratory at JPL. In addition, the key characteristics of both Voyager I and Voyager 2 cameras are tabulated.

Danielson, G. E.↗

On the linearity of the SWP camera of the international ultraviolet explorer /IUE/ - A correction algorithm

An algorithm is presented for correcting IUE low resolution spectral images obtained with the SWP camera for some of the non-linearity effects reported by Bohlin et al. (1980). The non-linearity problem, which affects SWP images processed at Goddard Space Flight Center in the period May 22, 1978 to July 7, 1979 and at VILSPA in the period June 14, 1978 to August 6, 1979, was essentially due to the use of an Intensity Transfer Function (ITF) that erroneously included a blank image in the 20 percent exposure level. The correction algorithm described here was adopted by the three IUE Agencies in November 1979 as being suitable for most IUE users. It has the advantages to be applicable to any kind of low resolution SWP spectra, to introduce errors which are usually less than the intrinsic photometric errors, and to be of simple application. The results obtained by applying the method to a representative set of spectra of both point and extended sources are reported. In addition, a new evaluation of linearity and reproducibility of the SWP spectral data is provided, based on the improved ITF.

Holm, A.↗

Modulated Multiple Slit Camera for improved localization of gamma ray bursts

An instrument is described in which a cylindrical modulation collimator is added to one half of a Multiple Slit Camera (MSC) coded-aperture imaging system. The instrument provides gamma-ray burst positions from a single spacecraft that are as precise as the best positions from the long-baseline network of interplanetary spacecraft. The determination of fine positions is described, and the fine-position capability is shown to operate over about two-thirds of the MSC's nearly all-sky field of view. It is noted that the addition of the modulation collimator only slightly reduces the system's sensitivity and can improve the location precision for gamma-ray bursts and slower hard-X-ray transients to about 0.1 sq arcmin.

Gorenstein, P.↗

An example of the performance of the space telescope planetary camera

A ground-based CCD picture of the relatively local dwarf irregular galaxy Sextans B is used to simulate a Space Telescope Planetary Camera image of a similar galaxy at the distance of the Virgo cluster. The gains to be had with the Space Telescope are discussed graphically.

Hoessel, J. G.↗

High-speed motion picture camera experiments of cavitation in dynamically loaded journal bearings

A high-speed camera was used to investigate cavitation in dynamically loaded journal bearings. The length-diameter ratio of the bearing, the speeds of the shaft and bearing, the surface material of the shaft, and the static and dynamic eccentricity of the bearing were varied. The results reveal not only the appearance of gas cavitation, but also the development of previously unsuspected vapor cavitation. It was found that gas cavitation increases with time until, after many hundreds of pressure cycles, there is a constant amount of gas kept in the cavitation zone of the bearing. The gas can have pressures of many times the atmospheric pressure. Vapor cavitation bubbles, on the other hand, collapse at pressures lower than the atmospheric pressure and cannot be transported through a high-pressure zone, nor does the amount of vapor cavitation in a bearing increase with time. Analysis is given to support the experimental findings for both gas and vapor cavitation. Previously announced in STAR as N82-20543

Hamrock, B. J.↗

Spas color camera

The procedures to be followed in assessing the performance of the MOS color camera are defined. Aspects considered include: horizontal and vertical resolution; value of the video signal; gray scale rendition; environmental (vibration and temperature) tests; signal to noise ratios; and white balance correction.

Toffales, C.↗

Image dissector camera system study

Various aspects of a rendezvous and docking system using an image dissector detector as compared to a GaAs detector were discussed. Investigation into a gimbled scanning system is also covered and the measured video response curves from the image dissector camera are presented. Rendezvous will occur at ranges greater than 100 meters. The maximum range considered was 1000 meters. During docking, the range, range-rate, angle, and angle-rate to each reflector on the satellite must be measured. Docking range will be from 3 to 100 meters. The system consists of a CW laser diode transmitter and an image dissector receiver. The transmitter beam is amplitude modulated with three sine wave tones for ranging. The beam is coaxially combined with the receiver beam. Mechanical deflection of the transmitter beam, + or - 10 degrees in both X and Y, can be accomplished before or after it is combined with the receiver beam. The receiver will have a field-of-view (FOV) of 20 degrees and an instantaneous field-of-view (IFOV) of two milliradians (mrad) and will be electronically scanned in the image dissector. The increase in performance obtained from the GaAs photocathode is not needed to meet the present performance requirements.

Howell, L.↗

In-situ measurements of alloy oxidation/corrosion/erosion using a video camera and proximity sensor with microcomputer control

Two noncontacting and nondestructive, remotely controlled methods of measuring the progress of oxidation/corrosion/erosion of metal alloys, exposed to flame test conditions, are described. The external diameter of a sample under test in a flame was measured by a video camera width measurement system. An eddy current proximity probe system, for measurements outside of the flame, was also developed and tested. The two techniques were applied to the measurement of the oxidation of 304 stainless steel at 910 C using a Mach 0.3 flame. The eddy current probe system yielded a recession rate of 0.41 mils diameter loss per hour and the video system gave 0.27.

Deadmore, D. L.↗

High resolution bone mineral densitometry with a gamma camera

A technique by which the regional distribution of bone mineral can be determined in bone samples from small animals is described. The technique employs an Anger camera interfaced to a medical computer. High resolution imaging is possible by producing magnified images of the bone samples. Regional densitometry of femurs from oophorectomised and bone mineral loss.

Leblanc, A.↗

High spatial resolution observations of NGC 7027 with a 10 micron array camera

First observations of a planetary nebula with an infrared charge injection device (CID) array camera are reported. The 10 micron images of NGC 7027 have spatial resolution comparable to that of the highest resolution (less than 2 arcsec) radio aperture-synthesis maps of this source. A much closer correspondence between the mid-infrared and radio appearance of NGC 7027 was found than was known previously, confirming that warm dust is coextensive and well mixed with the gas in the ionized zone. Using maps at three wavelengths, the spatial dependence of the shape of the 8-13 micron spectrum within the nebula is examined. The dip at 9.60 microns is shallowest in regions of enhanced optical extinction (as determined from new images near 4000 and 9000 A obtained with an optical charge coupled device). The 9.60 micron emission is strongest in these same positions. It is shown that the results may be explained not by silicate absorption, but by a combination of emission from two distinct grain populations, one of which is also partly responsible for the variation in extinction across the nebula.

Arens, J. F.↗

Wide-Angle, Wide-Band Camera for Remote Imaging

Improved ultraviolet-to-infrared camera design combines high resolution and relatively wide field of view in remote-imaging system. Although design intended for satellite-borne system to give information on such Earth features as vegetation, pollution, and land formation mineral deposits, optical principle also useful in ground-based or airborne high-resolution television for imaging objects at great distances.

Atcheson, P. D.↗

Time Series Photometry with a CCD Camera

Time series observations of a field in the cluster NGC 4755 with a CCD camera are used to show that differential photometry between stars on the CCD frame is limited in accuracy mostly by photon statistics, over a 5 magnitude range. Scintillation noise appears to be almost entirely suppressed. The maximum accuracy possible is limited by the storage capacity of the CCD to about 0.001 mag.

Walker, A. R.↗

Astronomical applications of the new Goddard Si:Bi 16 x 16 array camera system

An improved 4-18 micron array camera system has been developed at NASA Goddard Space Flight Center for astronomical protometry, using 16 x 16 Si:Bi (bismuth dope silicon) accumulation mode charge injection device (AMCID) with 256 active pixels. An astronomical observing program using this device has been carried out. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Steward Observatory Mt. Lemmon 60 and 61-inch telescopes in May 1983, and at the NASA Infrared Telescope Facility (IRTF) at Mauna Kea in August 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.

Lamb, G.↗

Results from the transition region camera

Three series of high resolution ultra-violet pictures of the sun have been obtained during the three flights of rocket experiment T.R.C. Transition Region Camera) which took place on 3 July 1979, 23 September 1980 and 13 July 1982. These pictures reveal many structures in Ly alpha and ultraviolet continua at 160 nm and 220 nm. The scientific objectives, instrumentation, flight conditions and campaigns of simultaneous observations are described. The contribution of T.R.C. to solar physics is discussed in the framework of chromospheric multicomponent models, magnetic flux tubes, local heating and periodic structures in the chromosphere.

Foing, B. H.↗

Wind dynamic range video camera

A television camera apparatus is disclosed in which bright objects are attenuated to fit within the dynamic range of the system, while dim objects are not. The apparatus receives linearly polarized light from an object scene, the light being passed by a beam splitter and focused on the output plane of a liquid crystal light valve. The light valve is oriented such that, with no excitation from the cathode ray tube, all light is rotated 90 deg and focused on the input plane of the video sensor. The light is then converted to an electrical signal, which is amplified and used to excite the CRT. The resulting image is collected and focused by a lens onto the light valve which rotates the polarization vector of the light to an extent proportional to the light intensity from the CRT. The overall effect is to selectively attenuate the image pattern focused on the sensor.

Craig, G. D.↗