Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BYPASSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

EUV FEL light source based on energy recovery linac with on-orbit laser plasma injection

We report on a week-long study of a conceptual design of EUV FEL light source based on an energy recovery linac with on-orbit laser plasma accelerator injection scheme. We carried out this study during USPAS Summer 2023 session of Unifying Physics of Accelerators, Lasers and Plasma applying the art of inventiveness TRIZ. An ultrashort Ti-sapphire laser accelerates electron beams from a gas target with mean energy of 20 MeV, which are then ramped up to 1 GeV in a five-turn scheme with a series of fixed field alternating magnets and two superconducting RF cavities (100 MeV per cavity per turn). The electron beam is then bypassed to an undulator line optimized to generate EUV light of 13.5 nm at kW level in a single pass.

43 PARTICLE ACCELERATORS↗

Design of an optical amplifier for amplified OSC in IOTA facility at Fermilab

Optical stochastic cooling (OSC) is a cutting-edge beam cooling technology to reduce, control the 3 dimensional spread and the motion of particle beams. It has recently been successfully, experimentally, demonstrated in Fermilab's IOTA storage ring, marking a major step forward in beam cooling. OSC has the potential to significantly improve both the performance and flexibility as a beam cooling system. One promising way to boost OSC performance is by adding a high-gain optical amplifier. However, this amplifier must be carefully designed to meet the specific constraints of the OSC system. A major challenge lies in the limited optical delay, which is just 6 mm for the case of IOTA, set by the beam bypass, restricts us to use a short-length gain medium. This, along with IOTA’s high repetition rate and the relatively long duration of the optical pulses, limits the peak power available for the pump laser without damaging the crystal, which is crucial for achieving strong nonlinear gain. Additionally, it's essential to preserve the phase coherence of the undulator radiation during amplification, which further complicates the amplifier design. This report details a specialized amplifier setup that addresses these challenges, includes simulations of the integrated system, and summarizes the latest experimental progress and results.

Mondal, Abhishek [Fermilab]↗

ASGarD: Adaptive Sparse Grid Discretization

Many areas of science exhibit physical processes that are described by high dimensional partial differential equations (PDEs), e.g., the 4D, 5D and 6D models describing magnetized fusion plasmas, models describing quantum chemistry, or derivatives pricing. Such problems are affected by the so-called “curse of dimensionality” where the number of degrees of freedom (or unknowns) required to be solved for scales as N D where N is the number of grid points in any given dimension D. A simple, albeit naive, 6D example is demonstrated in the left panel of Figure 1. With N = 1000 grid points in each dimension, the memory required just to store the solution vector, not to mention forming the matrix required to advance such a system in time, would exceed an exabyte - and also the available memory on the largest of supercomputers available today. The right panel of Figure 1 demonstrates potential savings for a range of problem dimensionalities and grid resolution. While there are methods to simulate such high-dimensional systems, they are mostly based on Monte-Carlo methods, which rely on a statistical sampling such that the resulting solutions include noise. Since the noise in such methods can only be reduced at a rate proportional to $\sqrt{N_p}$ where N p is the number of Monte-Carlo samples, there is a need for continuum, or grid/mesh-based methods for high-dimensional problems, which both do not suffer from noise and bypass the curse of dimensionality. We present a simulation framework that provides such a method using adaptive sparse grids.

97 MATHEMATICS AND COMPUTING↗

Correlations to predict frictional pressure loss of hydraulic-fracturing slurry in coiled tubing

Compared with conventional-tubing fracturing, coiled-tubing (CT) fracturing has several advantages. CT fracturing has become an effective stimulation technique for multizone oil and gas wells. It is also an attractive production-enhancement method for multiseam coalbed-methane wells, and wells with bypassed zones. The excessive frictional pressure loss through CT has been a concern in fracturing. The small diameter of the string limits the cross-sectional area open to flow. Furthermore, the tubing curvature causes secondary flow and results in extra flow resistance. This increased frictional pressure loss results in high surface pumping pressure. The maximum possible pump rate and sand concentration, therefore, have to be reduced. To design a CT fracturing job properly, it is essential to predict the frictional pressure loss through the tubing accurately. This paper presents correlations for the prediction of frictional pressure loss of fracturing slurries in straight tubing and CT. They are developed on the basis of full-scale slurry-flow tests with 11/2-in. CT and slurries prepared with 35 lbm/1,000 gal of guar gel. The extensive experiments were conducted at the full-scale CT-flow test facility. The proposed correlations have been verified with the experimental data and actual field CT-fracturing data. Case studies of wells recently fractured are provided to demonstrate the application of the correlations. The correlations will be useful to the CT engineers in their hydraulics design calculations.

01 COAL, LIGNITE, AND PEAT↗

Surfactant-Aided Low-Salinity Waterflooding for Low-Temperature Carbonate Reservoirs

Carbonate reservoirs tend to be oil-wet/mixed-wet and heterogeneous because of mineralogy and diagenesis. The objective of this study is to improve oil recovery in low-temperature dolomite reservoirs using low-salinity and surfactant-aided spontaneous imbibition. The low-salinity brine composition was optimized using ζ-potential measurements, contact-angle (CA) experiments, and a novel wettability-alteration measure. Significant wettability alteration was observed on dolomite rocks at a salinity of 2,500 ppm. We evaluated 37 surfactants by performing CA, interfacial-tension (IFT), and spontaneous-imbibition experiments. Here, three (quaternary ammonium) cationic and one (sulfonate) anionic surfactants showed significant wettability alteration and produced 43–63% of original oil in place (OOIP) by spontaneous imbibition. At a low temperature (35°C), oil recovery by low-salinity effect is small compared with that by wettability-altering surfactants. Coreflood tests were performed with a selected low-salinity cationic surfactant solution. A novel coreflood was proposed that modeled heterogeneity and dynamic imbibition into low-permeability regions. The results of the “heterogeneous” coreflood were consistent with that of spontaneous-imbibition tests. These experiments demonstrated that a combination of low-salinity brine and surfactants can make originally oil-wet dolomite rocks more water-wet and improve oil recovery from regions bypassed by waterflood at a low temperature of 35°C.

02 PETROLEUM↗

Direct Injection of Biomineralizing Agents to Restore Injectivity and Wellbore Integrity

Summary In this manuscript, we describe the second of two field demonstrations of microbially induced calcium carbonate precipitation (MICP) performed in a failed waterflood injection well in Indiana. In 2012, fracture-related flow pathways developed in the wellbore cement, causing injection water to bypass the oil-bearing formation and enter a high-permeability sandstone thief zone, thereby substantially decreasing injection pressure. In the first field demonstration, our study team characterized the well's mode of failure and successfully applied MICP to decrease flow through the defective cement. However, because the MICP treatment was conducted using a bailer delivery system, the degree of permeability reduction achievable was not adequate to fully restore the historic injection pressure of 1,400 psi at 1 gal/min. For the second field demonstration (reported herein), a direct injection system was developed that substantially increased the injection volume of MICP-promoting fluids. Two strategies were implemented to produce more ureolytic microbes: resuspending concentrated frozen cells immediately before injection and scaling up the bioreactor growth capacity. Multiple pulses of microbes and urea-calcium media were pumped into a string of 1-in.-diameter tubing separated by brine spacers and injected continuously at a flow rate of 3.4 to 1.4 gal/min. During the third day of injection, an injection pressure of 1,384 psi at a flow rate of 1.4 gal/min was achieved, and the experiment was terminated. This study demonstrates that MICP can be successfully used in large-volume applications where the time frame for the delivery of reactants is limited. This finding has significant relevance for commercialization of the MICP biotechnology in the oil and gas industry.

Engineering↗

Experimental Study of Microgel Conformance-Control Treatment for a Polymer-Flooding Reservoir Containing Superpermeable Channels

Summary Polymer flooding has been widely used to improve oil recovery. However, its effectiveness would be diminished when channels (e.g., fractures, fracture-like channels, void-space conduits) are present in a reservoir. In this study, we designed a series of particular sandwich-like channel models and tested the effectiveness and applicable conditions of micrometer-sized preformed particle gels (PPGs, or microgels) in improving the polymer-flooding efficiency. We studied the selective penetration and placement of the microgel particles, and their abilities for fluid diversion and oil-recovery improvement. The results suggest that polymer flooding alone would be inefficient to achieve a satisfactory oil recovery as the heterogeneity of the reservoir becomes more serious (e.g., permeability contrast kc/km > 50). The polymer solution would vainly flow through the channels and leave the majority of oil in the matrices behind. Additional conformance-treatment efforts are required. We tried to inject microgels in an attempt to shut off the channels. After the microgel treatment, impressive improvement of the polymer-flooding performance was observed in some of our experiments. The water cut could be reduced significantly by as high as nearly 40%, and the sweep efficiency and overall oil recovery of the polymer flood were improved. The conditions under which the microgel-treatment strategy was effective were further explored. We observed that the microgels form an external impermeable cake at the very beginning of microgel injection and prevent the gel particles from entering the matrices. Instead, the microgel particles could selectively penetrate and shut off the superpermeable channels under proper conditions. Our results suggest that the 260-µm microgel particles tested in this study are effective to attack the excessive-water-production problem and improve the oil recovery when the channel has a high permeability (>50 darcies). The gels are unlikely to be effective for channels that are less than 30 darcies because of the penetration/transport difficulties. After the gels effectively penetrate and shut off the superpermeable channel, the subsequent polymer solution is diverted to the matrices (i.e., the unswept oil zones) to displace the bypassed oil. Overall, this study provides important insights to help achieve successful polymer-flooding applications in reservoirs with superpermeable channels.

Engineering↗

Nanoparticle-Surfactant Stabilized Strong Foam for Enhanced Oil Recovery in High-Salinity Fractured Carbonate Reservoirs

Summary Foam flooding can minimize bypassing in gasfloods in fractured reservoirs. Finding a foam formulation effective in high-salinity brine is challenging, especially with divalent cations, e.g., American Petroleum Institute (API) brine (8% NaCl with 2% CaCl2). When formulating with nanoparticles, the colloidal dispersion stability is difficult due to the dramatic reduction in zeta potential and the Debye length at high salinity. The aim of this work was to develop a strong foam in API brine at the ambient temperature, using a nonionic surfactant and ethyl cellulose nanoparticles (ECNP), for gasflooding in fractured carbonate reservoirs. ECNPs was synthesized and dispersed in API brine using a nonionic surfactant (also denoted as SF). SF and SF/ECNP foams were generated, and their stability was studied at atmospheric pressure and 950 psi. Foam mobility was measured in a sandpack at high pressure. Foam flood experiments were conducted in oil-saturated fractured carbonate cores. The nonionic surfactant proved to be a good dispersion agent for ECNP in API brine. The SF/ECNP mixture stabilized foam in API brine, even in the presence of oil. Injecting a partially miscible gas (below its minimum miscibility pressure) as an SF foam into a fractured core more than doubles the oil recovery over injection of the gas alone. The injection of the strong foam (SF/ECNP) further improves the oil recovery over that of the SF foam, indicating the synergy between ECNP and surfactant. ECNP accumulates in the foam lamella and induces larger pressure gradients in the fracture to divert more gas into the matrix for oil displacement.

Engineering↗

Modeling, Design, and Testing of a Novel Biphasic Solvent-Enabled Absorption System for Post-Combustion Carbon Capture

A novel absorption process enabled by a new class of biphasic solvents for post-combustion carbon capture (BiCAP) is presently being developed at the University of Illinois at Urbana-Champaign. The new biphasic solvents are water-lean solvent blends that develop dual liquid phases with the absorbed CO2 highly enriched in one of the phases. These solvents are superior in CO2 capacity and have high thermal and oxidative stability compared to MEA. The BiCAP technology features a unique process configuration of multi-stage CO2 absorption and liquid–liquid phase separation during CO2 absorption, allowing continual separation and removal of the CO2-enriched liquid phase for maintaining low solvent viscosity and a fast absorption rate. A 40 kWe-scale skid has recently been constructed at the Abbott Power Plant in Champaign, IL, to test the BiCAP solvent in continuous operation with a slipstream of real post-combustion flue gas. Along with improvements in the stripping configuration including cold feed bypass, the process is expected to achieve a minimum reboiler duty of 2,210 kJ/kg CO2 captured at a stripper operating pressure of 6 bar.

20 FOSSIL-FUELED POWER PLANTS↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

Parametric Testing and Evaluation of a Novel Biphasic Absorption Process for Post-Combustion Carbon Capture

A novel biphasic CO2 absorption process (BiCAP) is being developed at the University of Illinois. BiCAP is enabled by using a new class of biphasic solvents developed based on multi-property criteria for postcombustion carbon capture. The process was previously demonstrated at the lab-scale, including in 10 kWe absorption and desorption column systems. In the current study, the process has been scaled up by building and testing a 40 kWe integrated capture skid at a power plant. Parametric tests for two biphasic solvents were conducted with the synthetic flue gas made of bottle CO2 gas and air to validate the performance and operational flexibility of the unit with respect to varying process or operating conditions. Operation of the phase separator, which is unique equipment to BiCAP, was verified to be stable and efficient. Two liquid phases could be separated via static settlement based on a density difference and >90% of the CO2 absorbed was concentrated in the separated CO2-rich phase. Results of parametric tests showed that the minimum heat duty appeared at the optimal stripping pressure. A higher stripping temperature was more favourable to improve overall energy performance. Introducing a secondary cold solvent feed stream to the top of the stripper via bypassing the cross heat exchanger helped reduce the heat loss carried with water vapour. Test results also revealed that the heat duty requirement was comparable when the CO2 concentration in flue gas decreased from ~11 to 4 vol.% as the phase separation decoupled the absorption and desorption steps in BiCAP. Under typical steady-state conditions, both biphasic solvents lowered the process heat duty by >40% compared with the reference 30 wt.% monoethanolamine solvent.

Absorption↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Unitarity cuts of the worldsheet

We compute the imaginary parts of genus-one string scattering amplitudes. Following Witten’s i\varepsilon i ε prescription for the integration contour on the moduli space of worldsheets, we give a general algorithm for computing unitarity cuts of the annulus, Möbius strip, and torus topologies exactly in \alpha' α ′ . With the help of tropical analysis, we show how the intricate pattern of thresholds (normal and anomalous) opening up arises from the worldsheet computation. The result is a manifestly-convergent representation of the imaginary parts of amplitudes, which has the analytic form expected from Cutkosky rules in field theory, but bypasses the need for performing laborious sums over the intermediate states. We use this representation to study various physical aspects of string amplitudes, including their behavior in the (s,t) ( s , t ) plane, exponential suppression, decay widths of massive strings, total cross section, and low-energy expansions. We find that planar annulus amplitudes exhibit a version of low-spin dominance: at any finite energy, only a finite number of low partial-wave spins give an appreciable contribution to the imaginary part.

97 MATHEMATICS AND COMPUTING↗

Applying Quantum Tomography to Hadronic Interactions

A proper description of inclusive reactions is expressed with density matrices. Quantum tomography reconstructs density matrices from experimental observables. We review recent work that applies quantum tomography to practical experimental data analysis. Almost all field-theoretic formalism and modeling used in a traditional approach is circumvented with great efficiency. Tomographically-determined density matrices can express information about quantum systems which cannot in principle be expressed with distributions defined by classical probability. Topics such as entanglement and von Neumann entropy can be accessed using the same natural language where they are defined. A deep relation exists between separability, as defined in quantum information science, and factorization, as defined in high energy physics. Factorization acquires a non-perturbative definition when expressed in terms of a conditional form of separability. An example illustrates how to go from data for momentum 4-vectors to a density matrix while bypassing almost all the formalism of the Standard Model.

Martens, J. C.↗

Nanometer-scale siRNA carriers incorporating peptidomimetic oligomers: physical characterization and biological activity

Synthetic short interfering RNA (siRNA) oligonucleotides can trigger the RNA interference pathway and lead to selective gene silencing. Despite considerable enthusiasm and investment, formidable challenges remain that may deter translating this breakthrough discovery into clinical applications. In particular, the development of efficient, nontoxic, nonimmunogenic methods for delivering siRNA in vivo has proven to be exceptionally challenging. Thorough analysis of the relationship between the structure and function of siRNA carrier systems, both in isolation and in complex with RNA, will facilitate the design of efficient nonviral siRNA delivery vehicles. In this study, we explore the relationship between the physicochemical characteristics and the biological activity of “lipitoid” compounds as potent siRNA delivery vehicles. Lipitoids are cationic peptidomimetic oligomers incorporating a peptoid and a phospholipid moiety. Lipitoids can associate with siRNA oligonucleotides and self-assemble into spherical lipitoid-based nanoparticles (LNPs), with dimensions that are dependent upon the medium and the stoichiometric ratio between the cationic monomers of the lipitoid and anionic siRNA oligonucleotides. The morphology, gene silencing efficiency, and cytotoxicity of the siRNA-loaded LNPs are similarly sensitive to the stoichiometry of the complexes. The medium in which the LNPs are formed affects the assembled cargo particles’ characteristics such as particle size, transfection efficiency, and stability. Formation of the LNPs in the biological, serum-free medium OptiMEM resulted in LNPs an order of magnitude larger than LNPs formed in water, and were twice as efficient in siRNA transfection compared to LNPs formed in water. Inhibitor studies were conducted to elucidate the efficiency of lysosomal escape and the uptake mechanism of the siRNA-loaded LNPs. Our results suggest that these lipitoid-based, siRNA-loaded spherical LNPs are internalized through a lipid raft-dependent and dynaminmediated pathway, circumventing endosomal and lysosomal encapsulation. The lipitoid-siRNA nanospheres proved to be suitable platforms for investigating the critical parameters determining the efficiency of transfection agents, revealing the necessity for conducting characterization studies in biological media. The investigation of the LNP internalization pathway points to an alternative uptake route that bypasses the lysosome, explaining the surprisingly high efficiency of LNPs and suggesting that the uptake mechanism should be probed rather than assumed for the next generation of rationally designed transfection agents.

59 BASIC BIOLOGICAL SCIENCES↗

Next Generation Nuclear Plant Phenomena Identification and Ranking Tables (PIRTs) Volume 2: Accident and Thermal Fluids Analysis PIRTs

An accident, thermal fluids, and reactor physics phenomena identification and ranking process was conducted by a panel of experts on the next generation nuclear plant (NGNP) design (consideration given to both pebble-bed and prismatic gas-cooled reactor configurations). Safety-relevant phenomena, importance, and knowledge base were assessed for the following event classes: (1) normal operation (including some reactor physics aspects), (2) general loss of forced circulation (G-LOFC), (3) pressurized loss-of-forced circulation (P-LOFC), (4) depressurized loss-of-forced circulation (D-LOFC), (5) air ingress (following D-LOFC), (6) reactivity transients - including anticipated transients without scram (ATWS), (7) processes coupled via intermediate heat exchanger (IHX) (IHX failure with molten salt), and (8) steam/water ingress. The panel's judgment of the importance ranking of a given phenomenon (or process) was based on the effect it had on one or more figures of merit or evaluation criteria. These included public and worker dose, fuel failure, and primary (and other safety) system integrity. The major phenomena of concern that were identified and categorized as high importance combined with medium to low knowledge follow: (1) core coolant bypass flows (normal operation), (2) power/flux profiles (normal operation), (3) outlet plenum flows (normal operation), (4) reactivity-temperature feedback coefficients for high-plutonium-content cores (normal operation and accidents), (5) fission product release related to the transport of silver (normal operation), (6)emissivity aspects for the vessel and reactor cavity cooling system (G-LOFC), (7) reactor vessel cavity air circulation and heat transfer (G-LOFC), and (8)convection/radiation heating of upper vessel area (P-LOFC).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computational Fluid Dynamics Modeling of the Bonneville Project: Tailrace Spill Patterns for Low Flows and Corner Collector Smolt Egress

In 2003, an extension of the existing ice and trash sluiceway was added at Bonneville Powerhouse 2 (B2). This extension started at the existing corner collector for the ice and trash sluiceway adjacent to Bonneville Powerhouse 2 and the new sluiceway was extended to the downstream end of Cascade Island. The sluiceway was designed to improve juvenile salmon survival by bypassing turbine passage at B2, and placing these smolt in downstream flowing water minimizing their exposure to fish and avian predators. In this study, a previously developed computational fluid dynamics model was modified and used to characterized tailrace hydraulics and sluiceway egress conditions for low total river flows and low levels of spillway flow. STAR-CD v4.10 was used for seven scenarios of low total river flow and low spill discharges. The simulation results were specifically examined to look at tailrace hydraulics at 5 ft below the tailwater elevation, and streamlines used to compare streamline pathways for streamlines originating in the corner collector outfall and adjacent to the outfall. These streamlines indicated that for all higher spill percentage cases (25% and greater) that streamlines from the corner collector did not approach the shoreline at the downstream end of Bradford Island. For the cases with much larger spill percentages, the streamlines from the corner collector were mid-channel or closer to the Washington shore as they moved downstream. Although at 25% spill at 75 kcfs total river, the total spill volume was sufficient to "cushion" the flow from the corner collector from the Bradford Island shore, areas of recirculation were modeled in the spillway tailrace. However, at the lowest flows and spill percentages, the streamlines from the B2 corner collector pass very close to the Bradford Island shore. In addition, the very flow velocity flows and large areas of recirculation greatly increase potential predator exposure of the spillway passed smolt. If there is concern for egress issues for smolt passing through the spillway, the spill pattern and volume need to be revisited.

54 ENVIRONMENTAL SCIENCES↗

OECD/MCCI 2-D Core Concrete Interaction (CCI) tests : final report February 28, 2006.

Although extensive research has been conducted over the last several years in the areas of Core-Concrete Interaction (CCI) and debris coolability, two important issues warrant further investigation. The first issue concerns the effectiveness of water in terminating a CCI by flooding the interacting masses from above, thereby quenching the molten core debris and rendering it permanently coolable. This safety issue was investigated in the EPRI-sponsored Melt Attack and Coolability Experiments (MACE) program. The approach was to conduct large scale, integral-type reactor materials experiments with core melt masses ranging up to two metric tons. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanism(s) that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.20 m. This decoupling is not expected for a typical reactor cavity, which has a span of 5-6 m. Even though the crust may mechanically bond to the reactor cavity walls, the weight of the coolant and the crust itself is expected to periodically fracture the crust and restore contact with the melt. Although crust fracturing does not ensure that coolability will be achieved, it nonetheless provides a pathway for water to recontact the underlying melt, thereby allowing other debris cooling mechanisms to proceed. A related task of the current program, which is not addressed in this particular report, is to measure crust strength to check the hypothesis that a corium crust would not be strong enough to sustain melt/crust separation in a plant accident. The second important issue concerns long-term, two-dimensional concrete ablation by a prototypic core oxide melt. As discussed by Foit the existing reactor material database for dry cavity conditions is solely one-dimensional. Although the MACE Scoping Test was carried out with a two-dimensional concrete cavity, the interaction was flooded soon after ablation was initiated to investigate debris coolability. Moreover, due to the scoping nature of this test, the apparatus was minimally instrumented and therefore the results are of limited value from the code validation viewpoint. Aside from the MACE program, the COTELS test series also investigated 2-D CCI under flooded cavity conditions. However, the input power density for these tests was quite high relative to the prototypic case. Finally, the BETA test series provided valuable data on 2-D core concrete interaction under dry cavity conditions, but these tests focused on investigating the interaction of the metallic (steel) phase with concrete. Due to these limitations, there is significant uncertainty in the partition of energy dissipated for the ablation of concrete in the lateral and axial directions under dry cavity conditions for the case of a core oxide melt. Accurate knowledge of this 'power split' is important in the evaluation of the consequences of an ex-vessel severe accident; e.g., lateral erosion can undermine containment structures, while axial erosion can penetrate the basemat, leading to ground contamination and/or possible containment bypass. As a result of this uncertainty, there are still substantial differences among computer codes in the prediction of 2-D cavity erosion behavior under both wet and dry cavity conditions. In light of the above issues, the OECD-sponsored Melt Coolability and Concrete Interaction (MCCI) program was initiated at Argonne National Laboratory. The project conducted reactor materials experiments and associated analysis to achieve the following technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focused on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term 2-D core-concrete interactions under both wet and dry cavity conditions. Data from the various tests conducted as part of the program are being used to develop and validate models and codes that are used to extrapolate the experimental findings to plant conditions. Achievement of these technical objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs of future plants. The project completed three large scale CCI experiments to address the second technical objective defined above.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗