Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Vegetation Warming Experiment: 15N Uptake Experiment Arctagrostis latifolia Canopy Traits, Utqiagvik (Barrow), Alaska, 2018

This dataset consists of measured Arctagrostis latifolia canopy traits harvested from vegetation warming experiment enclosures and paired control plots located on the BEO, Utqiavik, Alaska. Harvest types include both natural abundance and enriched A. latifolia. Canopy traits measured include leaf area index (LAI), specific leaf area (SLA) and maximum height. Vegetation warming chambers (Zero Power) were deployed on the Barrow Environmental Observatory (BEO), Utqiavik, Alaska. These chambers (Figure 1) consistently elevated air temperatures by approximately 4°C using a self-venting system described by Lewin et al (2017). Five chambers were deployed from June 17, 2018 to September 24, 2018 on the BEO within a 1 km2 area centered on 71.275N, -156.641W. Each chamber was co-located with an ambient plot where temperatures were not manipulated on patches of tundra containing the target species Arctagrostis latifolia. An intensive field campaign in late July investigated the impact of warming had on A. latifolia biomass, chemistry, and uptake of 15N labeled ammonia that was injected into the surface soils for one week. Initial measurements were taken on July 21, 2018. Harvest occurred on July 27, 2018. Water-extractable nutrients in soils were measured in July following harvests of A. latifolia plants and underlying soils. Availability of ammonia, nitrate, and phosphate throughout the growing season was measured by extracting nutrients bound to anion and cation binding resins deployed from July through September. Environmental variables (thaw depth, surface soil temperatures, surface soil moisture) were measured. Leaf traits and root traits of A. latifolia were also measured. This dataset includes one csv file and one pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature: Supporting Data

This dataset was used to assess the potential of a Distributed Temperature Profiling System developed and presented in the article named "A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature" and submitted to Cryosphere. There are three comma-delimited data files (.csv). Each of them contains snow or soil temperature with times (UTC) in the first column and temperature at various vertical distance from the ground surface (positive means in air/snow) or below the ground surface (negative means in soil). The measurements were acquired every 15 minutes. Data collected at the East River, Colorado site with two probes: 1) measuring air/snow temperature from 1.1 m above the ground surface to the ground surface (with 5 or 10 cm spacing between sensors) and 2) measuring soil temperature from the ground surface to 0.7 m depth (with 5 or 10 cm spacing between sensors). Data collected at the Teller road (mile 27) site near Nome, Alaska with one probe: measuring soil temperature from 5 cm above the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors). Additional metadata included in *.csv and *.pdf files. NGEE Arctic Project Summary: The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

CLMU Anthropogenic Heat Sensitivity Experiments

User namelist settings, code changes, and driving scripts to set to CLM5 on NERSC for deciphering the sensitivity of urban canopy air temperature to anthropogenic heat flux experiments. More details are available in README.md.

Earth Systems↗

BSEC VPRM 10m Hourly Biogenic Fluxes in Baltimore (2021)

Model outputs from the Vegetation Photosynthesis and Respiration Model (VPRM: version from Horne et al. in prep). Model remote sensing inputs come from Sential 2-derived EVI and LSWI. Model meteorological inputs for two-meter air temperature and shortwave incoming come from the BSEC WRF 2021 Control Run (Foust, W. 2023). Plant functional Types (PFTs) are spatially classified using the Chesapeake Bay Program 2018 land use land cover product. The final biogenic flux (µmol CO2 m^-2 s^-1) outputs of NEE, RESP, and GEE are a weighted average based on the portion of PFTs within the cell. Individual PFT outputs are saved inside PFT directories (e.g., Crops, Grass, etc.) inside the specific month directory. Model outputs are denoted as a negative flux into the land system (i.e., photosynthesis) and a positive flux as a net release into the overlying atmosphere. Respiration (RESP) fluxes are positive and combine heterotrophic (only soil) and autotrophic sources. Gross ecosystem exchange (GEE) is a negative flux driven by only photosynthetic activity from vegetation, and the Net ecosystem exchange (NEE) is the sum of the two (i.e., NEE=RESP+GEE). Data Characteristics Spatial Resolution: 10m Temporal Resolution: Hourly File Format: VPRM_ _BSEC. .tif (Hour is in UTC) For more information on the model results, please email Jason Horne (jph6488@psu.edu). References: Foust, W. (2023). BSEC WRF 2021 Control Run Output (v0.1.0) [Data set]. MSD-LIVE Data Repository. https://data.msdlive.org/records/m0e6m-vvq17

Baltimore↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Thermistor connector assembly increases accuracy of measurements

Isolation of the thermistor from spurious heat transfer for accurately measuring ambient air temperatures is accomplished by a mounting consisting of a transparent plastic film bonded to a U-shaped phenolic board with depositions of aluminum on each face and upper edge, and a variable capacitor for fine tuning.

Source record↗

Cold sea survival.

Two prototype three-man life rafts were evaluated during the winter months in Arctic waters off Kodiak Island, Alaska, to assess potential survival problems and determine tolerance limits. Each raft incorporated thermal characteristics specifically designed for cold water. Water and air temperatures varied from 0 to +2 C and -5 to +4 C respectively. All subjects were removed upon reaching subjective tolerance. The results showed that none of the clothing assemblies was adequate to maintain a person in comfort even with dry boarding. No significant biochemical shifts in the blood or urine were found. The TUL raft was found to be superior in its thermal characteristics and afforded better subject protection. General tolerance for cold water immersion, wet and dry, and cold water raft exposures are depicted graphically, based on previously reported data.

Veghte, J. H.↗

Fatigue flaw growth and NDI evaluation for preventing through cracks in spacecraft tankage structures

A program was conducted to determine the fatigue-crack propagation behavior of parent and welded 2219-T87 aluminum alloy sheet under controlled cyclic stress conditions in room temperature air and 300 F air. Specimens possessing an initial surface defect of controlled dimensions were cycled under constant load amplitude until the propagating fatigue crack penetrated the back surface of the specimen. A series of precracked specimens were prepared to determine optimum penetrant, X-ray, ultrasonic, and eddy current nondestructive inspection procedures.

Pettit, D. E.↗

Climatology of Urban-regional Systems

Urbanized areas have come to be significant if not dominant components of many regional land surfaces. They represent perhaps the most dramatic recent change man has made in his environment - a change that may well burgeon in the foreseeable future as greater percentages of world populations crowd into metropolitan areas. The climate of urban-regional systems is involved because temperature, air, and pollutants added to the air are significant aspects of this change. During the past two years, substantial progress has been made in the application of remote sensing techniques to the study of urban climatology by programs jointly sponsored by NASA and the United States Geological Survey. The initial effort has endeavored with considerable success to map terrestrial radiation emission or the general thermal state of the land surface with the aid of imaging radiometers (mechanical-optical scanners).

Pease, R. W.↗

Geophysical aspects of remote sensing

Results obtained through the NASA Earth Resources Aircraft Program at Mill Creek, Oklahoma, provide a case history example of the application of remote sensing to the identification of geologic rock units. Thermal infrared images are interpreted by means of a sequence of models of increasing complexity. The roles of various parameters are examined: rock properties (thermal inertia, albedo, emissivity), site location (latitude), season (sun's declination), atmospheric effects (cloud cover, transmission, air temperature), and topographic orientation (slope, azimuth). The results obtained at this site also illustrate the development of an important application of remote sensing in geologic identification. Relatively pure limestones and dolomites of the Mill Creek test area can be differentiated in nighttime infrared images, and facies changes between them can be detected along and across strike. The predominance on the earth's surface of sedimentary rocks, of which limestone and dolomite are major members, indicates the importance of this discrimination.

Watson, K.↗

Evaluation of an experimental short-length annular combustor: One-side-entry dilution airflow concept

A test program was conducted to evaluate an experimental short-length annular combustor that uses a one-side-entry dilution airflow concept. The combustor design features scoops on the outer liner for controlling the primary- and secondary-zone airflow distribution. Combustor inlet total pressures were limited to 62 N/sq cm (90 psia) with inlet-air temperatures from 590 K (600 F) to 890 K (1150 F). At a diffuser inlet Mach number of 0.25, the exit temperature pattern factor was 0.44 with an average exit temperature of 1436 K (2124 F) and a total pressure loss of 4.3 percent. At a diffuser inlet Mach number of 0.31, the exit temperature pattern factor was reduced to 0.29 with an average exit temperature of 1450 K (2151 F) and a total pressure loss of 6.1 percent. Nominal combustion efficiencies of 100 percent were obtained with the ASTM A-1 fuel. Exhaust gas emissions, smoke, and altitude relight data are included with exit-temperature profiles and distribution patterns.

Humenik, F. M.↗