Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Accelerator mass spectrometry of Strontium-90 for homeland security, environmental monitoring, and human health

Strontium-90 is one of the most hazardous materials managed by agencies charged with protecting the public from radiation. Traditional radiometric methods have been limited by low sample throughput and slow turnaround times. Mass spectrometry offers the advantage of shorter analysis times and the ability to measure samples immediately after processing, however conventional mass spectrometric techniques are susceptible to molecular isobaric interferences that limit their overall sensitivity. In contrast, accelerator mass spectrometry is insensitive to molecular interferences and we have therefore begun developing a method for determination of {sup 90}Sr by accelerator mass spectrometry. Despite a pervasive interference from {sup 90}Zr, our initial development has yielded an instrumental background of {approx} 10{sup 8} atoms (75 mBq) per sample. Further refinement of our system (e.g., redesign of our detector, use of alternative target materials) is expected to push the background below 10{sup 6} atoms, close to the theoretical limit for AMS. Once we have refined our system and developed suitable sample preparation protocols, we will utilize our capability in applications to homeland security, environmental monitoring, and human health.

07 ISOTOPE AND RADIATION SOURCES↗

High Resolution Photon Timing with MCP-PMTs: A Comparison of a Commercial Constant Fraction Discriminator (CFD) with the ASIC-based Waveform Digitizers TARGET and WaveCatcher

There is a considerable interest to develop new time-of-flight detectors using, for example, micro-channel-plate photodetectors (MCP-PMTs). The question we pose in this paper is if new waveform digitizer ASICs, such as the WaveCatcher and TARGET, operating with a sampling rate of 2-3 GSa/s can compete with 1GHz BW CFD/TDC/ADC electronics. We have performed a series of measurements with these waveform digitizers coupled to MCP-PMTs operating at low gain and with a signal equivalent to {approx}40 photoelectrons. The tests were done with a laser diode on detectors operating under the same condition used previously in SLAC and Fermilab beam tests. Our test results indicate that one can achieve similar resolution with both methods. Although the commercial CFD-based electronics does exist and performs very well, it is difficult to implement on a very large scale, and therefore the custom electronics is needed. In addition, the analog delay line requirement makes it very difficult to incorporate CFD discriminators in ASIC designs.

43 PARTICLE ACCELERATORS↗

THz pulses from 4th generation X-ray light sources: Perspectives for fully synchronized THz pump X-ray probe experiments

In this paper the prospects of terahertz (THz) pulses generated at 4th generation X-ray light sources are presented on the example of recent results from a prototype set-up at the soft X-ray FEL FLASH. It is shown, that the THz pulses from the relativistic ultra short electron bunches have unique properties, that at FLASH are utilized for novel THz pump X-ray probe experiments with a robust few fs resolution. Based on these experiences it is discussed, how future facilities can benefit from implementation of similar or further improved instrumentation.

43 PARTICLE ACCELERATORS↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experiment to measure interplanetary and solar electrons

The paper describes an ISEE experiment designed to study interplanetary and solar electrons in the energy range between solar wind and galactic cosmic rays. The instrumentation is designed to identify and measure electron fluxes with high energy resolution and high sensitivity from approximately 2 keV to 1 MeV. Angular distributions of these electrons will also be obtained; in addition, energetic ions above 50 keV will be measured. Measurements of particle acceleration in solar flares, solar radio emission, interplanetary particles and shock wave acceleration, and low energy electron propagation are discussed. The instrumentation is described with emphasis on the semiconductor telescopes, the electrostatic analyzer, and the electronics.

Anderson, K. A.↗

hls4ml: An Open-Source Codesign Workflow to Empower Scientific Low-Power Machine Learning Devices

Accessible machine learning algorithms, software, and diagnostic tools for energy-efficient devices and systems are extremely valuable across a broad range of application domains. In scientific domains, real-time near-sensor processing can drastically improve experimental design and accelerate scientific discoveries. To support domain scientists, we have developed hls4ml, an open-source software-hardware codesign workflow to interpret and translate machine learning algorithms for implementation with both FPGA and ASIC technologies. We expand on previous hls4ml work by extending capabilities and techniques towards low-power implementations and increased usability: new Python APIs, quantization-aware pruning, end-to-end FPGA workflows, long pipeline kernels for low power, and new device backends include an ASIC workflow. Taken together, these and continued efforts in hls4ml will arm a new generation of domain scientists with accessible, efficient, and powerful tools for machine-learning-accelerated discovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument Front-Ends at Fermilab During Run II

The optimization of an accelerator relies on the ability to monitor the behavior of the beam in an intelligent and timely fashion. The use of processor-driven front-ends allowed for the deployment of smart systems in the field for improved data collection and analysis during Run II. This paper describes the implementation of the two main systems used: National Instruments LabVIEW running on PCs, and WindRiver's VxWorks real-time operating system running in a VME crate processor.

43 PARTICLE ACCELERATORS↗

Studies of acceleration processes in the corona using ion measurements on the solar probe mission

The energy spectra and composition of particles escaping from the Sun provide essential information on mechanisms responsible for their acceleration, and may also be used to characterize the regions where they are accelerated and confined and through which they propagate. The suprathermal energy range, which extends from solar wind energies (approximately 1 KeV) to about 1 MeV/nucleon, is of special interest to studies of nonthermal acceleration processes because a large fraction of particles is likely to be accelerated into this energy range. Data obtained from near earth observations of particles in the suprathermal energy range are reviewed. The necessary capabilities of an a ion composition experiment in the solar probe mission and the required ion measurements are discussed. A possible configuration of an instrument consisting of an electrostatic deflection system, modest post acceleration, and a time of flight versus energy system is described as well as its possible location on the spacecraft.

Gloeckler, G.↗

Nuclear physics detector technology applied to plant biology research

The ability to detect the emissions of radioactive isotopes through radioactive decay (e.g. beta particles, x-rays and gamma-rays) has been used for over 80 years as a tracer method for studying natural phenomena. More recently a positron emitting radioisotope of carbon: {sup 11}C has been utilized as a {sup 11}CO{sub 2} tracer for plant ecophysiology research. Because of its ease of incorporation into the plant via photosynthesis, the {sup 11}CO{sub 2} radiotracer is a powerful tool for use in plant biology research. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using {sup 11}CO{sub 2}. Presently there are several groups developing and using new PET instrumentation for plant based studies. Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) is involved in PET detector development for plant imaging utilizing technologies developed for nuclear physics research. The latest developments of the use of a LYSO scintillator based PET detector system for {sup 11}CO{sub 2} tracer studies in plants will be briefly outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of a dielectric material in an ion source on the ion beam current density and ion beam energy

To understand a strong focusing phenomenon that occurs in a low-energy hydrogen ion beam, the electron temperature, the electron density, and the space potential in an ion source with cusped magnetic fields are measured before and after the transition to the focusing state using an electrostatic probe. The experimental results show that no significant changes are observed before or after the transition. However, we found unique phenomena that are characterized by the position of the electrostatic probe in the ion source chamber. Specifically, the extracted ion beam current density and energy are obviously enhanced in the case where the electrostatic probe, which is covered by a dielectric material, is placed close to an acceleration electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Lag of a Friez Type Cup Anemometer

Tests on a Friez type cup anemometer have been made in the variable density wind tunnel of the Langley Memorial Aeronautical Laboratory to calibrate the instrument and to determine its suitability for velocity measurements of wind gusts. The instrument was calibrated against a Pitot-static tube placed directly above the anemometer at air densities corresponding to sea level, and to an altitude of approximately 6000 feet. Air-speed acceleration tests were made to determine the lag in the instrument reading. The calibration results indicate that there should be an altitude correction. It is concluded that the cup anemometer is too sluggish for velocity measurements of wind gusts.

INSTRUMENTS - ANEMOMETERS - FRIEZ↗

Early experiments in charged particle beams from the Space Shuttle

Characteristics of studies on board the Shuttle involving the interaction of particle beams with the atmosphere and the ionosphere, and the effects of the beams on the electrical potential of the platform, are discussed. Noting that the Shuttle allows greater weight and power demands by scientific payloads than previous satellite launches, the OSS-1 Vehicle Charging and Potential experiment and the Spacelab 1 Particle Accelerator and Phenomena Induced by Charged Particle Beams are described. Instrumentation details are provided, including charge and current probes, the Spherical Retarding Potential Analyzer, the Fast Pulse Electron Generator, and digital control and interface units. The SEPAC equipment, which comprises an electron beam accelerator, and MPD plasma jet, and diagnostic units are detailed, and operating procedures and experiment objectives are outlined.

Raitt, W. J.↗

Simultaneous measurement of gravity acceleration and gravity gradient with an atom interferometer

We demonstrate a method to measure the gravitational acceleration with a dual cloud atom interferometer; the use of simultaneous atom interferometers reduces the effect of seismic noise on the gravity measurement. At the same time, the apparatus is capable of accurate measurements of the vertical gravity gradient. The ability to determine the gravity acceleration and gravity gradient simultaneously and with the same instrument opens interesting perspectives in geophysical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GLAST and Suzaku: Study on Cosmic-Ray Acceleration And Interaction in the Cosmos

The Gamma-Ray Large Area Space Telescope (GLAST) is an international and multiagency mission scheduled for launch in the fall 2007. The Large Area Telescope (LAT), the primary instrument of the mission, will survey the high energy sky found to be very dynamic and surprisingly diverse by its predecessor the Energetic Gamma Ray Experiment Telescope (EGRET). GLAST-LAT will have a much improved sensitivity when compared with EGRET and extend the higher energy coverage to {approx} 300 GeV. The instrument is now mounted on the spacecraft and undergoing a suite of pre-flight tests. Data analysis software has been tried out by collaborators in two rounds of 'Data Challenges' using simulated observations including backgrounds. The instrument performance and observational data on selected sources presented here have been obtained through the Data Challenges in the collaborative efforts. There are features in the GLAST-LAT observation possibly unfamiliar to X-ray astronomers: (1) GLAST will operate mostly in the survey mode; (2) the foreground objects (gas, dust, and star-light) become gamma-ray sources; (3) multiple sources will be 'confused' because of the wide point-spread-function. The last two features will pose a challenge for analysis on extended Galactic sources such as supernova remnants and pulsar wind nebulae: multi-wavelength study with X-ray instruments like Suzaku and atmospheric Chrenkov telescopes will become essential to dig out the underlying physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LANSCE beam instrumentation and the LANSCE refurbishment project

The heart of the LANSCE accelerator complex consists of Cockroft-Walton-type injectors, a drift-tube linac (DTL) and a side-coupled linac (CCL). These systems are approaching 40 years of age and a project to re-establish high-power capability and to extend the lifetime is underway. Many of the present beam diagnostic systems are difficult to maintain, and the original beam position monitors don't provide any data at all. These deficiencies hamper beam tuning and trouble-shooting efforts. One thrust of the refurbishment project is to restore reliable operation of the diagnostic systems. This paper describes the present diagnostics systems and their limitations and the envisaged next-generation systems. The emphasis will be on the uses and requirements for the systems rather than the solutions and engineering aspects of the refurbishment.

43 PARTICLE ACCELERATORS↗

Fabrication and testing of high-performance all-metal neutron guides and axisymmetric mirrors by electrochemical replication

Neutron scattering is one of the most useful methods of studying the structure of matter, with applications to biomedical, structural, magnetic and energy-related materials. Neutron-scattering instruments are installed around research reactors or accelerator-based neutron sources, and neutron guides are critical components of these facilities. They are neutron-transport optical devices consisting of state-of-the-art mirrors often tens of meters long. Here we demonstrate a novel fabrication method of all-metallic neutron guides and axisymmetric mirrors by electroplating from precision mandrels. The process allows for the fabrication of single-piece all-metal guides of prismatic and axisymmetric shapes. We also demonstrate supermirror guides and axisymmetric focusing supermirrors produced with the same technology. We present the fabrication and tests of the multilayer-coated replicated guides and optic and show that the mandrel is reproduced with high fidelity and reliability. Furthermore, such supermirror optics will provide game-changing improvements in neutron techniques.

36 MATERIALS SCIENCE↗

Power distribution studies for CMS forward tracker

The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory is carrying out R&D investigations for the upgrade of the power distribution system of the Compact Muon Solenoid (CMS) Pixel Tracker at the Large Hadron Collider (LHC). Among the goals of this effort is that of analyzing the feasibility of alternative powering schemes for the forward tracker, including DC to DC voltage conversion techniques using commercially available and custom switching regulator circuits. Tests of these approaches are performed using the PSI46 pixel readout chip currently in use at the CMS Tracker. Performance measures of the detector electronics will include pixel noise and threshold dispersion results. Issues related to susceptibility to switching noise will be studied and presented. In this paper, we describe the current power distribution network of the CMS Tracker, study the implications of the proposed upgrade with DC-DC converters powering scheme and perform noise susceptibility analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perspectives of future observations on particle acceleration in the heliosphere

The development of the quantitative study of particle acceleration processes in the outer heliosphere into the foreseeable future is outlined. In the near future, the combination of spacecraft, new improved instrumentation, and powerful plasma simulations are expected to enhance the understanding of acceleration processes in the near-earth environment, on the sun, and in the outer heliosphere. The multispacecraft mission CLUSTER will allow the most detailed view of the bow shock, while spacecraft passing through various regions of the inner and outer heliosphere are to provide the large-scale view needed to understand the heliospheric boundary. Improvements in ionic charge resolution and collecting power are to elucidate fractionation processes.

Moebius, Eberhard↗