Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Editorial announcements and information — ICFA Beam Dynamics Newsletter No. 81

This is a general information article of the ICFA Beam Dynamics Newsletter No. 81. Thus, it contains two forewords from the Editor-in-Chief and the issue editor, a workshop and conference report section, a recent Ph.D. thesis section, a forthcoming beam dynamics events section, and a section of announcements from the beam dynamics panel.

47 OTHER INSTRUMENTATION↗

Computational approaches to Coherent Synchrotron Radiation in two and three dimensions

Coherent Synchrotron Radiation (CSR) is an important and often detrimental effect in particle accelerators. While one-dimensional models have been successfully used to design and explain the behavior of modern machines, questions remain about their domain of validity. In recent years, two- and three-dimensional models have been developed that are amenable to efficient numerical computation. This article gives an overview of CSR computation from its discovery through the present state of the art.

43 PARTICLE ACCELERATORS↗

Editorial announcements and information — ICFA Beam Dynamics Newsletter No. 82

This is a general information article of the ICFA Beam Dynamics Newsletter No. 81. It contains two forewords from the Editor-in-Chief and the issue editor, a workshop and conference report section, a recent Ph.D. thesis section, a forthcoming beam dynamics events section, and a section of announcements from the beam dynamics panel.

43 PARTICLE ACCELERATORS↗

Concept of circular-linear energy recovery accelerator to probe the energy frontier

Energy-frontier accelerators provide powerful tools performing high precision measurements confirming the fundamentals of the physics and broadening new research horizons. Such machines are either driven by circular or linear accelerators. The circular machines, having the centre-of-mass (CM) energy values reaching 200 GeV (for leptons) and above, experience beam energy loss and quality dilution, for example, due to synchrotron radiation, limiting the overall CM energy achievable and requiring a constant energy top-up to compensate the loss and the beam quality dilution. Linear colliders overcome these limitations, while the finite capabilities of generating high average current beams limits the luminosity. This is partially compensated by the quality of the colliding beams. In this work, we suggest a novel design of circular-linear accelerator based on the merging of the “non-emitting”, low-energy storage rings and energy recovery linear accelerators. We suggest using the recently considered dual-axis asymmetric cavities to enable the operation of such a system, and in particular the energy recovery from spent, high-intensity beams. The machine considered, under the scope of the SNOWMASS-2021 initiative, can be potentially used to reach ultimate energy frontiers in high-energy physics as well as to drive next generation light sources. The merging of circular and linear systems, and applications of dual axes cavities, should allow the maintaining of high beam quality, high luminosity, and high energy efficiency, while offering a flexible energy management and opening clear opportunity for reducing the running cost. We note that the numbers shown in the paper are for illustration purpose and can be improved further.

43 PARTICLE ACCELERATORS↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Parametrizations of coupled betatron motion for strongly coupled lattices

The coupling of transverse motion is a natural occurrence in particle accelerators, either in the form of a residual coupling arising from imperfections or originating by design from strong systematic coupling fields. While the first can be treated perturbatively, the latter requires a robust approach adapted to strongly coupled optics, and a parametrization of the linear optics must be performed to explore beam dynamics in such peculiar lattices. This work highlights the key physical interpretations of the main parametrization formalisms to describe linear coupled optics, along with explicit links and comparisons of these parametrizations. Concepts rarely illustrated in other works, such as forced mode flips and local coupling, are explored in detail, clarifying some anomalies that can arise in lattice functions. The analytical methods have been implemented in a reference Python package and connected with ray-tracing and integration codes to explore examples of strongly coupled lattices, which are discussed in detail to highlight the key physical interpretations of the parametrizations and characteristics of the lattices.

47 OTHER INSTRUMENTATION↗

Editorial announcements and information — ICFA Beam Dynamics Newsletter No. 85

This is a general information article of the ICFA Beam Dynamics Newsletter No. 85. It contains foreword from the Editor-in-Chief and the issue editor, a workshop and conference report section, a recent Ph.D. thesis section, a forthcoming beam dynamics events section, and a section of announcements from the beam dynamics panel.

43 PARTICLE ACCELERATORS↗

D–MOPH–25: diverse MOF–molecule pairs for Henry’s constants prediction

Computational methods like grand-canonical Monte Carlo simulations and machine learning (ML) have accelerated metal–organic frameworks (MOF) exploration but are typically limited to a narrow range of adsorbates due to data availability and force field constraints. In this study, we introduce a dataset of diverse MOF–molecule pairs for Henry’s constant prediction, D–MOPH–25, which systematically explores a diverse chemical space by combining 113 molecular adsorbates with over 5000 MOF structures through an active learning process. D–MOPH–25 constitutes the most diverse adsorbate dataset used in any ML study of molecular adsorption in MOFs to date. Our workflow builds a benchmark for predicting Henry’s constants at 300 K, leveraging conformal prediction for uncertainty quantification. Assessment through Shannon entropy and uniform manifold approximation and projection confirms the comprehensiveness of D–MOPH–25 while highlighting the importance of robust classification to filter out unphysical data points in regression tasks. Although future enhancements in model architecture and sampling criteria could improve predictive performance, our dataset already spans the target space using only 2.31% of total possibilities. This comprehensive dataset facilitates assessment of model generalizability across adsorbate species and can establish a foundation for high-throughput MOF screening and ML-driven separation processes.

active learning↗

Adaptive X-ray imaging with reinforcement learning

X-ray imaging is a powerful technique to scan samples in a variety of contexts including biological, environmental and materials science, but commonly requires a synchrotron light source to produce X-rays at sufficient intensity. As these facilities are expensive to operate, the available beam time is limited and always in high demand. Particularly if the illuminated samples are sparse, standard raster scanning methods can be time-consuming, with a majority of that time being spent on areas of the image that carry little information. To increase the efficiency and maximize the information gain for a given time budget, we split the scanning process into a series of steps where previous measurements are used to inform the decision making and adapt the exposure distribution at later stages of the sequence. We formulate this task as a reinforcement learning problem where the goal is to produce a sequence of exposure maps that maximize a predefined scalar metric. We demonstrate the potential of this approach in simulations where the adaptive illumination can accelerate the measurement process by up to an order of magnitude compared with standard raster scanning. Finally, we present the first results from deploying the trained agents on an X-ray fluorescence beamline at the Stanford Synchrotron Radiation Lightsource.

Reinforcement Learning↗

Adaptive Control Parameters for Dispersal of Multi-Agent Mobile Ad Hoc Network (MANET) Swarms

A mobile ad hoc network is a collection of independent nodes that communicate wirelessly with one another. This paper investigates nodes that are swarm robots with communications and sensing capabilities. Each robot in the swarm may operate in a distributed and decentralized manner to achieve some goal. This paper presents a novel approach to dynamically adapting control parameters to achieve mesh configuration stability. The presented approach to robot interaction is based on spring force laws (attraction and repulsion laws) to create near-optimal mesh like configurations. In prior work, we presented the extended virtual spring mesh (EVSM) algorithm for the dispersion of robot swarms. This paper extends the EVSM framework by providing the first known study on the effects of adaptive versus static control parameters on robot swarm stability. The EVSM algorithm provides the following novelties: 1) improved performance with adaptive control parameters and 2) accelerated convergence with high formation effectiveness. Simulation results show that 120 robots reach convergence using adaptive control parameters more than twice as fast as with static control parameters in a multiple obstacle environment.

42 ENGINEERING↗

Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets

Purpose: The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters C1 and C2. The authors have investigated the effect on the absorbed dose distribution of the values given to these parameters in the target. Methods: A monoenergetic 6.26 MeV electron pencil beam from a point source was simulated impinging normally on a cylindrical tungsten target. Electrons leaving the tungsten were discarded. Radial absorbed dose profiles were obtained at 1.5 cm of depth in a water phantom located at 100 cm for values of C1 and C2 in the target both equal to 0.1, 0.01, or 0.001. A detailed simulation case was also considered and taken as the reference. Additionally, lateral dose profiles were estimated and compared with experimental measurements for a 6 MV photon beam of a Varian Clinac 2100 for the cases of C1 and C2 both set to 0.1 or 0.001 in the target. Results: On the central axis, the dose obtained for the case C1 = C2 = 0.1 shows a deviation of (17.2% ± 1.2%) with respect to the detailed simulation. This difference decreases to (3.7% ± 1.2%) for the case C1 = C2 = 0.01. The case C1 = C2 = 0.001 produces a radial dose profile that is equivalent to that of the detailed simulation within the reached statistical uncertainty of 1%. The effect is also appreciable in the crossline dose profiles estimated for the realistic geometry of the Linac. In another simulation, it was shown that the error made by choosing inappropriate transport parameters can be masked by tuning the energy and focal spot size of the initial beam. Conclusions: The use of large path lengths for the condensed simulation of electrons in a Linac target with PENELOPE conducts to deviations of the dose in the patient or phantom. Based on the results obtained in this work, values of C1 and C2 larger than 0.001 should not be used in Linac targets without further investigation.

07 ISOTOPE AND RADIATION SOURCES↗

Backscatter dose effects for high atomic number materials being irradiated in the presence of a magnetic field: A Monte Carlo study for the MRI linac

Purpose: To quantify and explain the backscatter dose effects for clinically relevant high atomic number materials being irradiated in the presence of a 1.5 T transverse magnetic field. Methods: Interface effects were investigated using Monte Carlo simulation techniques. We used GPUMCD (v5.1) and GEANT4 (v10.1) for this purpose. GPUMCD is a commercial software written for the Elekta AB, MRI linac. Dose was scored using GPUMCD in cubic voxels of side 1 and 0.5 mm, in two different virtual phantoms of dimensions 20 × 20 × 20 cm and 5 × 5 × 13.3 cm, respectively. A photon beam was generated from a point 143.5 cm away from the isocenter with energy distribution sampled from a histogram representing the true Elekta, MRI linac photon spectrum. A slab of variable thickness and position containing either bone, aluminum, titanium, stainless steel, or one of the two different dental filling materials was inserted as an inhomogeneity in the 20 × 20 × 20 cm phantom. The 5 × 5 × 13.3 cm phantom was used as a clinical test case in order to explain the dose perturbation effects for a head and neck cancer patient. The back scatter dose factor (BSDF) was defined as the ratio of the doses at a given depth with and without the presence of the inhomogeneity. Backscattered electron fluence was calculated at the inhomogeneity interface using GEANT4. A 1.5 T magnetic field was applied perpendicular to the direction of the beam in both phantoms, identical to the geometry in the Elekta MRI linac. Results: With the application of a 1.5 T magnetic field, all the BSDF’s were reduced by 12%–47%, compared to the no magnetic field case. The corresponding backscattered electron fluence at the interface was also reduced by 45%–64%. The reduction in the BSDF at the interface, due to the application of the magnetic field, is manifested in a different manner for each material. In the case of bone, the dose drops at the interface contrary to the expected increase when no magnetic field is applied. In the case of aluminum, the dose at the interface is the same with and without the presence of the aluminum. For all of the other materials the dose increases at the interface. Conclusions: The reduction in dose at the interface, in the presence of the magnetic field, is directly related to the reduction in backscattered electron fluence. This reduction occurs due to two different reasons. First, the electron spectrum hitting the interface is changed when the magnetic field is turned on, which results in changes in the electron scattering probability. Second, some electrons that have curved trajectories due to the presence of the magnetic field are absorbed by the higher density side of the interface and no longer contribute to the backscattered electron fluence.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR)

Purpose: DEAR is a radiation therapy technique utilizing synchronized motion of gantry and couch during delivery to optimize dose distribution homogeneity and penumbra for treatment of superficial disease. Dose calculation for DEAR is not yet supported by commercial TPSs. The purpose of this study is to demonstrate the feasibility of using a web-based Monte Carlo (MC) simulation tool (VirtuaLinac) to calculate dose distributions for a DEAR delivery. Methods: MC simulations were run through VirtuaLinac, which is based on the GEANT4 platform. VirtuaLinac utilizes detailed linac head geometry and material models, validated phase space files, and a voxelized phantom. The input was expanded to include an XML file for simulation of varying mechanical axes as a function of MU. A DEAR XML plan was generated and used in the MC simulation and delivered on a TrueBeam in Developer Mode. Radiographic film wrapped on a cylindrical phantom (12.5 cm radius) measured dose at a depth of 1.5 cm and compared to the simulation results. Results: A DEAR plan was simulated using an energy of 6 MeV and a 3×10 cm{sup 2} cut-out in a 15×15 cm{sup 2} applicator for a delivery of a 90° arc. The resulting data were found to provide qualitative and quantitative evidence that the simulation platform could be used as the basis for DEAR dose calculations. The resulting unwrapped 2D dose distributions agreed well in the cross-plane direction along the arc, with field sizes of 18.4 and 18.2 cm and penumbrae of 1.9 and 2.0 cm for measurements and simulations, respectively. Conclusion: Preliminary feasibility of a DEAR delivery using a web-based MC simulation platform has been demonstrated. This tool will benefit treatment planning for DEAR as a benchmark for developing other model based algorithms, allowing efficient optimization of trajectories, and quality assurance of plans without the need for extensive measurements.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-03: Pre-Treatment Surface Imaging Based Collision Detection

Purpose: Modern radiotherapy increasingly employs large immobilization devices, gantry attachments, and couch rotations for treatments. All of which raise the risk of collisions between the patient and the gantry / couch. Collision detection is often achieved by manually checking each couch position in the treatment room and sometimes results in extraneous imaging if collisions are detected after image based setup has begun. In the interest of improving efficiency and avoiding extra imaging, we explore the use of a surface imaging based collision detection model. Methods: Surfaces acquired from AlignRT (VisionRT, London, UK) were transferred in wavefront format to a custom Matlab (Mathworks, Natick, MA) software package (CCHECK). Computed tomography (CT) scans acquired at the same time were sent to CCHECK in DICOM format. In CCHECK, binary maps of the surfaces were created and overlaid on the CT images based on the fixed relationship of the AlignRT and CT coordinate systems. Isocenters were added through a graphical user interface (GUI). CCHECK then compares the inputted surfaces to a model of the linear accelerator (linac) to check for collisions at defined gantry and couch positions. Note, CCHECK may be used with or without a CT. Results: The nominal surface image field of view is 650 mm × 900 mm, with variance based on patient position and size. The accuracy of collision detections is primarily based on the linac model and the surface mapping process. The current linac model and mapping process yield detection accuracies on the order of 5 mm, assuming no change in patient posture between surface acquisition and treatment. Conclusions: CCHECK provides a non-ionizing method to check for collisions without the patient in the treatment room. Collision detection accuracy may be improved with more robust linac modeling. Additional gantry attachments (e.g. conical collimators) can be easily added to the model.

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-09: Validation of a Novel Therapeutic X-Ray Array Source and Collimation System

Purpose: We have experimentally characterized and simulated the dosimetric properties and spatial fidelity of a novel X-ray array source and collimation system called SPHINX that has the potential to generate complex intensity modulated X-ray beams by varying the electron beam intensity only, and without any moving parts like in multi-leaf collimators. Methods: We investigated the spatial fidelity and the X-ray performances of a SPHINX prototype in tungsten, using a Cyber Knife and the experimental high-energy electron beam line at XTA at SLAC National Laboratory. Dose distributions were recorded with gafchromic films, placed at the distal end of SPHINX and at several depths in a solid water phantom. The geometry of SPHINX and of the experimental set-ups was also modeled in Monte Carlo (MC) simulations with the FLUKA code, used to reproduce the experimental results and, after validation, to predict and optimize the performance and design of the SPHINX. Results: The results indicate significant particle leakage through the channels during a single-channel irradiation for high incident energies, followed by a rapid decrease for energies of clinical interest. When the collimator channels are used as target, the photon production increases, however at expense of the beam size that is also enlarged. The illumination of all channels simultaneously shows a fairly even transmission of the beam. Conclusion: With the measurements we have verified the MC models and the uniformity of beam transmission through SPHINX, and we have evaluated the importance of particle leakage through adjacent channels. These results can be used to optimize SPHINX design through the validated MC simulations. Funding: Weston Havens Foundation, Office of the Dean of Medical School and Office of the Provost (Stanford University). Loo, Maxim, Borchard, Tantawi are co-founders of TibaRay Inc. Loo and Tantawi are TibaRay Inc. board members. Loo and Maxim received grants from Varian Medical Systems and RaySearch Laboratory.

60 APPLIED LIFE SCIENCES↗

Progress in the development of the community Particle Accelerator Lattice Standard (PALS)

The Particle Accelerator Lattice Standard (PALS) is a community effort to create an open standard to promote lattice information exchange for particle accelerators. PALS development is a community-wide international effort involving accelerator physicists from multiple institutions. While it started as a lattice standard for beam dynamics simulations, it is now being extended to support other particle accelerator activities, in particular accelerator operation. With new accelerators that are becoming more complex, larger collaborations and the increasing imprint of artificial intelligence in all accelerator activities (from design to operation to workforce development), the imperative for a common, standardized accelerator ontology has been transitioning from “nice-to-have” to “must-have”. We will present the status of the project, its relations to other projects, including to two of the particle accelerator projects of the newly announced US DOE Genesis Mission: the Multi-Office Accelerator Team (MOAT) project and the Nuclear physics AI-Ready Accelerator Data (NARAD) project.

Brynes, A. [Science and Technology Facilities Coun↗

Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring

The primary radiological safety concern for the top-off injection, with the beam line front end safety shutters open, is the scenario where electrons could be conveyed down to the beam line through the front end due to the erroneous combination of lattice magnetic field settings and beam energy. It is of paramount importance to ensure that such events are of remote possibility. Particle tracking simulations by the NSLS-II Accelerator Physicists have shown that by a set of interlocking requirements of the lattice magnetic fields and by the implementation of physical apertures, the errant electron beam can be confined to the front end components within the storage ring.

36 MATERIALS SCIENCE↗

An Update on MicroBooNE’s Inclusive Single Photon Low Energy Excess Search

The MicroBooNE detector is a Liquid Argon Time Project Chamber (LArTPC) detector whose primary design goal is to understand the "low-energy-excess" anomaly seen by MiniBooNE. MicroBooNE's currently published results see no excess consistent with the MiniBooNE observation, emphasizing a need for improved searches in more channels. This note summarizes MicroBooNE's inclusive single photon selection using Wire-Cell reconstruction and pattern recognition, which is used to search for a low-energy-excess (LEE) anomaly in the inclusive single photon channel. The selection is similar to the Wire-Cell inclusive electron neutrino selection, but with a different signal definition and some modifications and additions to the pattern recognition tools. A selection with 7.0% efficiency and 40.2% purity is achieved for our targeted single photon signal simulated events.

43 PARTICLE ACCELERATORS↗