Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

First indirect x-ray imaging tests with an 88-mm diameter single crystal

Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

43 PARTICLE ACCELERATORS↗

HIGH-ENERGY X-RAY PINHOLE CAMERA FOR HIGH-RESOLUTION ELECTRON BEAM SIZE MEASUREMENTS

The Advanced Photon Source (APS) is developing a multi-bend achromat (MBA) lattice based storage ring as the next major upgrade, featuring a 20-fold reduction in emittance. Combining the reduction of beta functions, the electron beam sizes at bend magnet sources may be reduced to reach 5 – 10 µm for 10% vertical coupling. The x-ray pinhole camera currently used for beam size monitoring will not be adequate for the new task. By increasing the operating photon energy to 120 – 200 keV, the pinhole camera’s resolution is expected to reach below 4 µm. The peak height of the pinhole image will be used to monitor relative changes of the beam sizes and enable the feedback control of the emittance. We present the simulation and the design of a beam size monitor for the APS storage ring.

Yang, B.↗

Advanced Manufacturing of Alpha Double Prime Iron Nitride (ADPIN): An Innovative Rare Earth Element (REE) Free Ultra-High Performance Permanent Magnet for Clean Energy Applications

Iron nitride magnets offer the potential for large magnetic remanence magnets absent any rare earth materials [1]. This project was submitted in response to the funding opportunity announcement (FOA) from the Advanced Manufacturing Office (AMO) of the Office of Energy Efficiency & Renewable Energy (EERE) of the Department of Energy (DOE): DE-FOA-0001465: Advanced Manufacturing Projects for Emerging Research Exploration; Topic Area 1: Advanced Materials; Subtopic 1.1: Innovative Advanced Materials Manufacturing for Clean Energy to explore nitriding iron powder using a fluidized bed technique which if successful would accomplish nitriding the iron powder with reduce industrial energy intensity. Of particular concern when using metal powders at high temperatures in a fluidized bed reactor is the defluidization temperature of the bed, also known as the ‘bed collapse’ temperature. Above the defluidization temperature the metal powders can no longer fluidize and instead become an undesirable packed powder bed. Using the published results from the Institute of Process Engineering at the Chinese Academy of Sciences in Beijing, China, FeNix Magnetics was able to develop a spreadsheet calculation that allowed predictive guidelines for the defluidization temperature of iron powder based on the type of carrier gas, flow rate of the carrier gas, and the iron powder diameter. FeNix Magnetics was not able to conclude whether the temperatures to avoid bed defluidization that were achievable in a fluidized bed reactor actually resulted in nitriding the iron powder to the required level. In order to measure the amount of nitrogen in the iron powder, FeNix Magnetics contracted with the DOE sponsored Advanced Photon Source (APS) at Argonne National Laboratory to conduct X-Ray diffraction measurements. Unfortunately, due to COVID-19 restrictions, the DOE sponsored APS was closed and unable to provide X-Ray Diffraction measurements during this program.

36 MATERIALS SCIENCE↗

How Community Agreements Can Improve Workplace Culture in Physics

Equity, Diversity, and Inclusion (EDI) committees and Codes of Conduct (CoC) have become common in laboratories and physics departments across the country. However, very often these EDI committees and CoC are not equipped to provide practical consequences for violations, and therefore are mostly performative in nature. A considerable effort has been devoted by various groups within APS units and beyond the APS in developing instead what are now called Community Guidelines. Community Guidelines help implement the core principles in CoC, by setting expectations for participation in in-person events and virtual communication. When further accompanied by accountability and enforcement processes, they develop into Community Agreements. This White Paper discusses the elements necessary to create and implement an effective Community Agreement, reviews examples of Community Agreements in physics, and argues that physics collaborations, physics departments, and ultimately as many physics organizations as possible, however large or small, should have a Community Agreement in place. We advocate that Community Agreements should become part of the bylaws of any entity that has bylaws.

Barzi, Emanuela↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation timeframes and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford.

Lines, Amanda M.↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Chemical interaction matrix between reagents in a Purex based process

The United States Department of Energy (DOE) is the responsible entity for the disposal of the United States excess weapons grade plutonium. DOE selected a PUREX-based process to convert plutonium to low-enriched mixed oxide fuel for use in commercial nuclear power plants. To initiate this process in the United States, a Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF) is under construction and will be operated by Shaw AREVA MOX Services at the Savannah River Site. This facility will be licensed and regulated by the U.S. Nuclear Regulatory Commission (NRC). A PUREX process, similar to the one used at La Hague, France, will purify plutonium feedstock through solvent extraction. MFFF employs two major process operations to manufacture MOX fuel assemblies: (1) the Aqueous Polishing (AP) process to remove gallium and other impurities from plutonium feedstock and (2) the MOX fuel fabrication process (MP), which processes the oxides into pellets and manufactures the MOX fuel assemblies. The AP process consists of three major steps, dissolution, purification, and conversion, and is the center of the primary chemical processing. A study of process hazards controls has been initiated that will provide knowledge and protection against the chemical risks associated from mixing of reagents over the life time of the process. This paper presents a comprehensive chemical interaction matrix evaluation for the reagents used in the PUREX-based process. Chemical interaction matrix supplements the process conditions by providing a checklist of any potential inadvertent chemical reactions that may take place. It also identifies the chemical compatibility/incompatibility of the reagents if mixed by failure of operations or equipment within the process itself or mixed inadvertently by a technician in the laboratories. (aut0010ho.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials

Purpose: To provide quantitative information on the image registration differences from multiple systems for image-guided radiotherapy (IGRT) credentialing and margin reduction in clinical trials. Methods and Materials: Images and IGRT shift results from three different treatment systems (Tomotherapy Hi-Art, Elekta Synergy, Varian Trilogy) have been sent from various institutions to the Image-Guided Therapy QA Center (ITC) for evaluation for the Radiation Therapy Oncology Group (RTOG) trials. Nine patient datasets (five head-and-neck and four prostate) were included in the comparison, with each patient having 1-4 daily individual IGRT studies. In all cases, daily shifts were re-calculated by re-registration of the planning CT with the daily IGRT data using three independent software systems (MIMvista, FocalSim, VelocityAI). Automatic fusion was used in all calculations. The results were compared with those submitted from institutions. Similar regions of interest (ROIs) and same initial positions were used in registrations for inter-system comparison. Different slice spacings for CBCT sampling and different ROIs for registration were used in some cases to observe the variation of registration due to these factors. Results: For the 54 comparisons with head-and-neck datasets, the absolute values of differences of the registration results between different systems were 2.6 {+-} 2.1 mm (mean {+-} SD; range 0.1-8.6 mm, left-right [LR]), 1.7 {+-} 1.3 mm (0.0-4.9 mm, superior-inferior [SI]), and 1.8 {+-} 1.1 mm (0.1-4.0 mm, anterior-posterior [AP]). For the 66 comparisons in prostate cases, the differences were 1.1 {+-} 1.0 mm (0.0-4.6 mm, LR), 2.1 {+-} 1.7 mm (0.0-6.6 mm, SI), and 2.0 {+-} 1.8 mm (0.1-6.9 mm, AP). The differences caused by the slice spacing variation were relatively small, and the different ROI selections in FocalSim and MIMvista also had limited impact. Conclusion: The extent of differences was reported when different systems were used for image registration. Careful examination and quality assurance of the image registration process are crucial before considering margin reduction using IGRT in clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design Optimization of Innovative High-Level Waste Pipeline Unplugging Technologies - 13341

Florida International University (FIU) is currently working on the development and optimization of two innovative pipeline unplugging methods: the asynchronous pulsing system (APS) and the peristaltic crawler system (PCS). Experiments were conducted on the APS to determine how air in the pipeline influences the system's performance as well as determine the effectiveness of air mitigation techniques in a pipeline. The results obtained during the experimental phase of the project, including data from pipeline pressure pulse tests along with air bubble compression tests are presented. Single-cycle pulse amplification caused by a fast-acting cylinder piston pump in 21.8, 30.5, and 43.6 m pipelines were evaluated. Experiments were conducted on fully flooded pipelines as well as pipelines that contained various amounts of air to evaluate the system's performance when air is present in the pipeline. Also presented are details of the improvements implemented to the third generation crawler system (PCS). The improvements include the redesign of the rims of the unit to accommodate a camera system that provides visual feedback of the conditions inside the pipeline. Visual feedback allows the crawler to be used as a pipeline unplugging and inspection tool. Tests conducted previously demonstrated a significant reduction of the crawler speed with increasing length of tether. Current improvements include the positioning of a pneumatic valve manifold system that is located in close proximity to the crawler, rendering tether length independent of crawler speed. Additional improvements to increase the crawler's speed were also investigated and presented. Descriptions of the test beds, which were designed to emulate possible scenarios present on the Department of Energy (DOE) pipelines, are presented. Finally, conclusions and recommendations for the systems are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Management Processing Projects in the PRC - 16551

EnergySolutions continues to provide waste treatment solutions in the Peoples Republic of China (PRC). In 2015 ES had completed installation of systems at two different Nuclear power sites (Haiyang, an AP-1000{sup TM} site and Yangjiang, a CPR1000 site). This paper discusses progress on these two projects, and provides new information regarding the operation of the systems. The Yangjiang project became operational in the fall of 2015 while the Haiyang project will be done is nearly done with commissioning and is waiting for reactor operations. Haiyang Project: In the Shandong Province on China's northeast coast, EnergySolutions, as part of a consortium with China Power Investment (CPI) and Yuanda Environmental Protection Engineering Company (a PRC state-owned company), has designed and constructed the site's Site Rad Waste Treatment Facility (SRTF). The SRTF provides solid waste processing services for up to 8 AP-1000s{sup TM}. The SRTF performs the following functions: 1. Five year storage for HICs containing spent resin and filters from the nuclear power plants' waste liquid systems (WLS); 2. Sorting and Compaction System for solid waste generated from Nuclear Power Plant (NPP) operations. This system implements: a) Real time radiography to screen 200 liter waste drums for prohibited items, b) Pre-compaction, c) High Resolution Gamma Spectrophotometry (HRGS) for waste characterization, d) Supercompaction, e) Solidification of compacted drums inside overpack drums which are filled with 60 MPa compressive strength grout, and f) Automatic drum lidding which crimps the drum lid to the drum body. 3. Laundry services for NPP anti-contamination clothing. 4. At the nuclear islands, EnergySolutions is providing mobile liquid waste processing systems that utilize EnergySolutions Advanced Liquid Processing System ALPS{sup TM}/Advanced Injection Method System AIM{sup TM} processing systems to supplement the NPP's WLS system when radionuclide concentrations exceed release criteria. The spent resins and filters from the nuclear power plants are placed in EnergySolutions supplied HICs, dewatered using EnergySolutions Self Engaging Dewatering System (SEDS{sup TM}), and then placed in EnergySolutions 8-120B Type B cask for the transport of the HIC between the NPP and the SRTF and, ultimately, to a disposal site once it is ready for operations Yangjiang Project: EnergySolutions is providing liquid waste treatment system (TEU) and solid waste treatment system (TES) for Yangjiang units 3 and 4 for the China Nuclear Power Engineering Company (CNPEC). The Yangjiang site is located approximately 300 kilometers west of Hong Kong. The TEU system processes floor drain, chemical drain, and process drain tanks liquids to achieve a release concentration less than 37 Bq/l. The TES system receives spent resin and filters into HIC containers which are dewatered and subsequently transported to the Yangjiang sites QT building where they are stored for a period of up to 5 years or until a disposal site are available. TEU (Liquid waste treatment) consists of the following unit operations: - ALPS{sup TM}/AIM{sup TM} system, which includes two separate 8 vessel water treatment systems that consist of granular activated carbon (GAC), cation, anion ion and mixed bed media ion exchange (IX) columns; and: - A reverse osmosis system for final polishing, - TES (solid waste system), - SEDS (Self Engaging Dewatering System), - Shielding for the loading and storage of HICs, - Shielded transport container for the transfer of HIC to the QT building for storage, - Shielded transfer bell for the transport of spent filters from the NPP operating area to HIC. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks - 20380

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation time frames and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Side Cesium Removal for Hanford Tank Waste - Actual Waste Demonstrations - 20467

The US DOE and its contractors are evaluating several options for treating Hanford tank supernate streams to provide feed for the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant. At this time, the intent is to deploy a Tank-Side Cesium Removal system. The key unit operations for this process are filtration and cesium removal by ion exchange. To assess the anticipated performance of the system, tests with actual waste were performed with samples from Hanford tanks AW-102 and AP-107 to provide basis data regarding the performance of the system in treating these materials. The decanted supernate waste samples from tanks AW-102 and AP-107 were received directly by the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. These samples were then filtered to provide data on dead-end filtration with a Mott{sup TM} filter media grade 5. Subsequently, the samples were run through 10-milliliter ion exchange columns containing crystalline silicotitanate to assess the dynamic ion exchange performance of these feeds. Test results demonstrated that the planned TSCR operations should meet process performance expectations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chiral symmetry and Atiyah-Patodi-Singer index theorem for staggered fermions

We consider the Atiyah-Patodi-Singer (APS) index theorem corresponding to the chiral symmetry of a continuum formulation of staggered fermions called Kähler-Dirac fermions, which have been recently investigated as an ingredient in lattice constructions of chiral gauge theories. We point out that there are two notions of chiral symmetry for Kähler-Dirac fermions, both having a mixed perturbative anomaly with gravity leading to index theorems on closed manifolds. By formulating these theories on a manifold with boundary, we find the APS index theorems corresponding to each of these symmetries, necessary for a complete picture of anomaly inflow, using a recently discovered physics-motivated proof. We comment on a fundamental difference between the nature of these two symmetries by showing that a sensible local, symmetric boundary condition only exists for one of the two symmetries. This sheds light on how these symmetries behave under lattice discretization, and in particular on their use for recent symmetric-mass generation proposals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative analysis of cosmological simulations via angular power spectra

Cosmology is the study of the universe's origin, large-scale structure, and dynamics. One such area of study is understanding dark energy and dark matter. Dark matter has not been observed to interact with luminous matter other than through gravitational attractions, forming large scale structures observed throughout the universe. In this area, the primary model is the Lambda Cold Dark Matter (ΛCDM) model. This standard model consists of cosmological dark energy (Λ), cold dark matter (CDM), and normal luminous matter. We use Angular Power Spectra (APS) to compare simulated ΛCDM models with observed large-scale galaxy distributions from the DECam Local Volume Exploration Survey (DELVE). After ensuring that the simulations can produce APS which match observational results, we vary cosmological parameters to constrain the allowed ranges of parameter values that are consistent with the observed data.

Feithen, William↗

Neutron Skin Measurement of 208Pb and 48Ca Using Parity Violating Electron Scattering

Parity-violating electron scattering experiments (PVES) provides a clean probe of neutron densities that is model independent and free from strong interaction uncertainties in interpretation. The PREX-2 and CREX experiments were run in 2019 and 2020 at Jefferson laboratory measured the nucleon skin thickness, the difference between the r.m.s. neutron radius Rn and the r.m.s. proton radius Rp, of 208Pb and 48Ca via parity violating electroweak asymmetry in the elastic scattering of longitudinally polarized electrons. PREX-2 experiment was performed with 950 MeV electrons scattered at a 5¿ angle with Q2 = 0.00616 ± 0.00004 (GeV/c)2, while CREX used 2182 MeV electrons at the same angle with Q2 = 0.0297 ± 0.0002 (GeV/c)2. For PREX-2 the measured asymmetry was AP V = 550 ± 16 (stat.) ± (syst.) ppb, which corresponds to Rskin = 0.278 ± 0.078 (exp.) ± 0.012 (theo.) fm. The CREX asymmetry was AP V = 2668 ± 106 (stat.) ± 40 (syst.) ppb, which corresponds to Rskin = 0.121 ± 0.026 (exp.) ±0.024 (model) fm. One of the crucial systematic uncertainty that PREX-2 and CREX were sensitive to was the non-parity violating asymmetries that resulted from the helicity correlated false asymmetries in the polarized electron beam. There was a lot of work put towards understanding and suppressing the asymmetries arising from these effects. The parity violating asymmetry measurement required a very precise determination of the electron beam polarization. To accurately determine the beam polarization, a Compton polarimeter was used during both PREX-2 and CREX. A careful alignment of the laser to the Fabry-Perot cavity, data analysis and systematic control was employed to get a precise beam polarization result for the experiments. The PREX-2 measurement has broad implications for increasing our knowledge about neutron star structure and the equation of state of nuclear matter. The combined PREX and CREX results will have implications for future energy density functional calculations and the theory of nuclear structure.

Premathilake, Sachinthani↗

DESI DR1 Ly$α$ forest: 3D full-shape analysis and cosmological constraints

We perform an analysis of the full shapes of Lyman-$α$ (Ly$α$) forest correlation functions measured from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). Our analysis focuses on measuring the Alcock-Paczynski (AP) effect and the cosmic growth rate times the amplitude of matter fluctuations in spheres of $8$$h^{-1}\text{Mpc}$, $fσ_8$. We validate our measurements using two different sets of mocks, a series of data splits, and a large set of analysis variations, which were first performed blinded. Our analysis constrains the ratio $D_M/D_H(z_\mathrm{eff})=4.525\pm0.071$, where $D_H=c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, and the effective redshift is $z_\mathrm{eff}=2.33$. This is a factor of $2.4$ tighter than the Baryon Acoustic Oscillation (BAO) constraint from the same data. When combining with Ly$α$ BAO constraints from DESI DR2, we obtain the ratios $D_H(z_\mathrm{eff})/r_d=8.646\pm0.077$ and $D_M(z_\mathrm{eff})/r_d=38.90\pm0.38$, where $r_d$ is the sound horizon at the drag epoch. We also measure $fσ_8(z_\mathrm{eff}) = 0.37\; ^{+0.055}_{-0.065} \,(\mathrm{stat})\, \pm 0.033 \,(\mathrm{sys})$, but we do not use it for cosmological inference due to difficulties in its validation with mocks. In $Λ$CDM, our measurements are consistent with both cosmic microwave background (CMB) and galaxy clustering constraints. Using a nucleosynthesis prior but no CMB anisotropy information, we measure the Hubble constant to be $H_0 = 68.3\pm 1.6\;\,{\rm km\,s^{-1}\,Mpc^{-1}}$ within $Λ$CDM. Finally, we show that Ly$α$ forest AP measurements can help improve constraints on the dark energy equation of state, and are expected to play an important role in upcoming DESI analyses.

Cuceu, Andrei [LBL, Berkeley; Chicago U., KICP] (O↗

DOE CESER 6 GHz Interference Study

DOE CESER has sponsored Idaho National Laboratory (INL) to conduct an objective and independent study of potential 6 GHz interference from outdoor operation of unlicensed devices in the 6 GHz band on fixed service (FS) microwave communication links operated by electrical sector incumbents in that band. INL is collaborating with University of Notre Dame (UND), Electric Power Research Institute (EPRI), Lockard & White, Southern Company, and AT&T, to gather data with real-world 6 GHz interference experiments and identify (1) the potential for interference from unlicensed devices and (2) the interference necessary to cause harm to the incumbents. In addition to the functional assessment, a security assessment of the FCC mandated Automatic Frequency Coordination (AFC) System to regulate use of unlicensed 6 GHz standard power devices is also being conducted. A major objective is to create a science-based and defensible methodology used to produce the necessary data and to derive objective conclusions. This proven methodology can then be used to produce objective data and conclusions for other spectrum bands with similar incumbent uses including 4.4 – 4.9 GHz and 7.125 – 7.4 GHz, identified in the reconciliation bill that was adopted on July 4, 2025, as well as the National Spectrum Strategy discussions that are ongoing. This report contains 6 GHz field experiments and findings in the following real-world scenarios with commercial unlicensed standard power (SP) 6 GHz devices regulated by Automated Frequency Coordination (AFC): • University of Notre Dame (UND) Stadium with a capacity of 80,000 spectators, where Wi-Fi operating in 6 GHz has been deployed recently • Southern Company 6 GHz FS microwave link between Columbus and Fortson, Georgia Following are the following key findings from this study. 1. The AFC is under-protective of FS when line-of-sight exists along the path centerline. Data collected at Southern’s 6 GHz fixed link site shows significant erosion of as much as 21.4-24.4 dB of under-protection that can lead to potential service degradation under typical operating conditions. This first key finding is most likely the result of erroneous use of the RF propagation model. INL will collaborate with EPRI and the AFC Functional Requirements Working Group to submit a change request to the WinnForum TS-1014 standard towards correct use of the propagation model by the AFC. 2. There is additive interference effect of about 3 dB from nearly equal power interferers measured from simultaneous operation of two SP AP's operating co-channel with the FS receive from different locations along the path. This second key finding should be used to add the impact of additive interference of operation of multiple APs in the same geographical area, to the next generation of AFCs. INL will collaborate with FCC on the need for the AFC to consider additive interference. We also recommend that additional experiments are conducted on 6 GHz spectrum interference to further improve the AFC operation as the number of outdoor Wi-Fi devices continues to increase. These proposed steps and recommendations will make the co-existence of the incumbents and the 6 GHz outdoor Wi-Fi providers possible without any impact on the incumbents with a win-win outcome for all.

6 GHz↗

Planned Use of Pulsed Crab Cavities for Short X-Ray Pulse Generation at the Advanced Photon Source

Recently, we have explored application to the Advanced Photon Source (APS) of Zholents'[1] crab cavity scheme for production of short x-ray pulses. We assumed use of superconducting (SC) cavities in order to have a continuous stream of crabbed bunches and flexibility of operating modes. The challenges of the SC approach are related to the size, cost, and development time of the cavities and associated systems. A good case can be made [2] for a pulsed system using room-temperature cavities. APS has elected to pursue such a system in the near term, with the SC-based system planned for a later date. This paper describes the motivation for the pulsed system and gives an overview of the planned implementation and issues. Among these are overall configuration options and constraints, cavity design options, frequency choice, cavity design challenges, tolerances, instabilities, and diagnostics plans.

43 PARTICLE ACCELERATORS↗