Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity

Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largest five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ{sup ¯}, defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MAS{sup D} is normalized to the maximum diaphragmatic displacement and MAS{sup V} is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value ranging from 0.25 to 0.93. The DFT calculation was within 3 s per 1DRW. Correlations were found between 1DRW periodicity and 4DCT artifact severity: −0.71 for MAS{sup D} and −0.73 for MAS{sup V}. A BPI greater than 0.85 in a 1DRW suggests minimal motion artifacts in the corresponding 4DCT images. Conclusions: The breathing periodicity index and motion-artifact severity index are introduced to assess the relationship between 1DRW and 4DCT. A correlation between 1DRW periodicity and 4DCT artifact severity has been established. The 1DRW periodicity provides a rapid means to estimate 4DCT image quality. The rapid 1DRW analysis and the correlative relationship can be applied prospectively to identify irregular breathers as candidates for breath coaching prior to 4DCT scan and retrospectively to select high-quality 4DCT images for clinical motion-management research.

60 APPLIED LIFE SCIENCES↗

Estimation of neutron spectrum in the low-level gamma spectroscopy system using unfolding procedure

The radiation resulting from neutron interactions with Ge nuclei in active volume of HPGe detectors is one of the main concerns in low-level gamma spectroscopy measurements [1,2]. It is usually not possible to measure directly spectrum of neutrons which strike detector. This paper explore the possibility of estimation of neutron spectrum using measured activities of certain Ge(n,γ) and Ge(n,n’) reactions (obtained from low-level gamma measurements), available ENDF cross section data and unfolding procedures. In this work HPGe detector with passive shield made from commercial low background lead was used for the measurement. The most important objective of this study was to reconstruct muon induced neutron spectrum created in the shield of the HPGe detector. MAXED [3] and GRAVEL [4] algorithms for neutron spectra unfolding were used. The results of those two algorithms were compared and we analyzed the sensitivity of the unfolding procedure to the various input parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnosing Bias in Modeled Soil Moisture/runoff Coefficient Correlation Using the SMAP Level 4 Soil Moisture Product

The physical parameterization of key processes in land surface models (LSMs) remains uncertain, and new techniques are required to evaluate LSM accuracy over coarse spatial scales. Given the role of soil moisture in the partitioning of surface water fluxes (between infiltration, runoff and evapotranspiration), surface soil moisture (SSM) estimates represent an important observational benchmark for such evaluations. Here, we apply SSM estimates from the NASA Soil Moisture Active Passive Level 4 product (SMAP_L4) to diagnose bias in the coupling between SSM and surface runoff for multiple Noah-Multiple Physics (Noah-MP) LSM parameterization cases. Results demonstrate that Noah-MP surface runoff parameterizations often underestimate the coupling strength between pre-storm SSM and the event-scale runoff coefficient (RC; defined as the ratio between event-scale streamflow and precipitation volumes). This bias squanders RC information contained in pre-storm SSM and reduces RC estimation skill. Such bias can be quantified against an observational benchmark calculated using streamflow observations and SMAP_L4 SSM and applied to explain a substantial fraction of the observed basin-to-basin (and case-to-case) variability in the skill of event-scale Noah-MP RC estimates. Based on this concept, a novel case selection strategy for ungauged basins is introduced and demonstrated to successfully identify poorly performing Noah-MP parameterization cases.

SSM↗

BlendPATH (Blending Pipeline Analysis Tool for Hydrogen) [SWR-24-10]

BlendPATH provides case-by-case techno-economic analysis for potential projects where hydrogen is blended into a natural gas transmission pipeline. BlendPATH estimates 1) the transmission pipeline modifications and operating conditions necessary to blend hydrogen to a user specified volume faction of hydrogen in pipeline gas and 2) the incremental capital and operating expenses to prepare said transmission pipeline for hydrogen blending. BlendPATH is developed in Python and requires SAInt, a underlying commercial natural gas pipeline network modeling software, to run. Pipeline modification and operation condition estimation is guided by ASME B31.12. The intent of this software is to target application for projects in the initial project assessment stage and provide the user with the capability of assess promising opportunities before the use proceeds with further detailed pipeline evaluation based on a probable economic outcome.

Kee, Jamie↗

International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic disease along the circumference of the epidural space. Conclusions: This report provides consensus guidelines for target volume definition for spinal metastases receiving upfront SRS in common clinical situations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of radar at non-attenuating wavelengths as a tool for the estimation of rain attenuation at frequencies above 10 GHz

The paper describes radar techniques and modeling procedures for estimating slant path attenuation and site diversity performance. The estimation results of an ongoing experiment at Wallops Island, Virginia are examined. At this location a high resolution S-band radar (0.4 deg beamwidth) monitors the reflectivity at contiguous pulse volumes approximately colocated with an earth space-path along which the Comstar beacon signal at 28.56 GHz is received. Radar estimated levels of rain attenuation at 28.56 GHz are compared with directly measured values both on a case by case basis as well as statistically for summer and winter periods. Use is made of ground disdrometer measurements in the radar estimation scheme.

Goldhirsh, J.↗

Knowledge-based prediction of plan quality metrics in intracranial stereotactic radiosurgery

Purpose: The objective of this work was to develop a comprehensive knowledge-based methodology for predicting achievable dose–volume histograms (DVHs) and highly precise DVH-based quality metrics (QMs) in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans. Accurate QM estimation can identify suboptimal treatment plans and provide target optimization objectives to standardize and improve treatment planning. Methods: Correlating observed dose as it relates to the geometric relationship of organs-at-risk (OARs) to planning target volumes (PTVs) yields mathematical models to predict achievable DVHs. In SRS, DVH-based QMs such as brain V{sub 10Gy} (volume receiving 10 Gy or more), gradient measure (GM), and conformity index (CI) are used to evaluate plan quality. This study encompasses 223 linear accelerator-based SRS/SRT treatment plans (SRS plans) using volumetric-modulated arc therapy (VMAT), representing 95% of the institution’s VMAT radiosurgery load from the past four and a half years. Unfiltered models that use all available plans for the model training were built for each category with a stratification scheme based on target and OAR characteristics determined emergently through initial modeling process. Model predictive accuracy is measured by the mean and standard deviation of the difference between clinical and predicted QMs, δQM = QM{sub clin} − QM{sub pred}, and a coefficient of determination, R{sup 2}. For categories with a large number of plans, refined models are constructed by automatic elimination of suspected suboptimal plans from the training set. Using the refined model as a presumed achievable standard, potentially suboptimal plans are identified. Predictions of QM improvement are validated via standardized replanning of 20 suspected suboptimal plans based on dosimetric predictions. The significance of the QM improvement is evaluated using the Wilcoxon signed rank test. Results: The most accurate predictions are obtained when plans are stratified based on proximity to OARs and their PTV volume sizes. Volumes are categorized into small (V{sub PTV} < 2 cm{sup 3}), medium (2 cm{sup 3} < V{sub PTV} < 25 cm{sup 3}), and large (25 cm{sup 3} < V{sub PTV}). The unfiltered models demonstrate the ability to predict GMs to ∼1 mm and fractional brain V{sub 10Gy} to ∼25% for plans with large V{sub PTV} and critical OAR involvements. Increased accuracy and precision of QM predictions are obtained when high quality plans are selected for the model training. For the small and medium V{sub PTV} plans without critical OAR involvement, predictive ability was evaluated using the refined model. For training plans, the model predicted GM to an accuracy of 0.2 ± 0.3 mm and fractional brain V{sub 10Gy} to 0.04 ± 0.12, suggesting highly accurate predictive ability. For excluded plans, the average δGM was 1.1 mm and fractional brain V{sub 10Gy} was 0.20. These δQM are significantly greater than those of the model training plans (p < 0.001). For CI, predictions are close to clinical values and no significant difference was observed between the training and excluded plans (p = 0.19). Twenty outliers with δGM > 1.35 mm were identified as potentially suboptimal, and replanning these cases using predicted target objectives demonstrates significant improvements on QMs: on average, 1.1 mm reduction in GM (p < 0.001) and 23% reduction in brain V{sub 10Gy} (p < 0.001). After replanning, the difference of δGM distribution between the 20 replans and the refined model training plans was marginal. Conclusions: The results demonstrate the ability to predict SRS QMs precisely and to identify suboptimal plans. Furthermore, the knowledge-based DVH predictions were directly used as target optimization objectives and allowed a standardized planning process that bettered the clinically approved plans. Full clinical application of this methodology can improve consistency of SRS plan quality in a wide range of PTV volume and proximity to OARs and facilitate automated treatment planning for this critical treatment site.

60 APPLIED LIFE SCIENCES↗

The multiple depleted mantle components in the Hawaiian-Emperor chain

Oceanic island basalts are targeted for geochemical study because they provide a direct window into mantle composition and a wealth of information on the dynamics and timescales associated with Earth mixing. Previous studies mainly focused on the shield volcanic stage of oceanic islands and the more fusible, enriched mantle components that are easily distinguished in those basalts. Mantle depleted compositions are typically more difficult to resolve unless large amounts of this material participated in mantle melting (e.g., mid-ocean ridges), or unique processes allow for their compositions to be erupted undiluted, such as very small degrees of melting of a source with minimal fusible enriched components (e.g., rejuvenated basalts) or as xenoliths (e.g., abyssal peridotites). Mantle depleted components, defined here as material with low time-integrated Rb/Sr (low 87 Sr/ 86 Sr) and high time-integrated Sm/Nd and Lu/Hf ratios (high 143 Nd/ 144 Nd and 176 Hf/ 177 Hf) relative to primitive mantle, derive from a potentially very large volume reservoir (up to 80% of the mantle), and therefore need adequate characterization in order estimate the composition of the Earth and mantle-derived melts. Here, this review focuses on mantle depleted compositions in oceanic island basalts using the Hawaiian-Emperor chain as a case study. The Hawaiian-Emperor chain is the ~6000 km long geological record of the deeply sourced Hawaiian mantle plume, active for >81 Myr. Hawaiian volcanism evolves through four volcanic stages as a volcano traverses the Hawaiian plume: alkalic preshield, tholeiitic shield (80–90% volcano volume), alkalic postshield (~1%), and silica undersaturated rejuvenated (<0.1%). We report Pb-Sr-Nd-Hf isotope compositions and trace element concentrations of three rejuvenated Northwest Hawaiian Ridge basalts and compare them to an exhaustive compiled dataset of basalts from the Hawaiian Islands to the Emperor Seamounts. The Northwest Hawaiian Ridge (NWHR) includes 51 volcanoes spanning ~42 m.y. between the bend in the Hawaiian-Emperor chain and the Hawaiian Islands where there is no high-precision isotopic data published on the rejuvenated-stage over ~47% of the chain. NWHR and Hawaiian Island rejuvenated basalts are geochemically similar, indicating a consistent source for rejuvenated volcanism over ~12.5 million years. In contrast, shield-stage basalts from the oldest Emperor Seamounts are more depleted in isotopic composition (i.e., higher 176 Hf/ 177 Hf, and 143 Nd/ 144 Nd with lower 87 Sr/ 86 Sr and 208 Pb*/ 206 Pb*) and trace element concentrations (i.e., much lower concentrations of highly incompatible elements) than all other depleted Hawaiian basalts younger than the bend, including NWHR rejuvenated basalts. The strongly depleted source for the oldest Emperor Seamounts (>70 Ma) was likely related to interaction with the Kula-Pacific-Izanagi mid-ocean ridge spreading system active near the Hawaiian plume in the Late Cretaceous. In contrast, the incompatible trace element ratios of NWHR rejuvenated basalts require a distinct source in the Hawaiian mantle plume that was imprinted by ancient (>1 Ga) partial melting, likely ancient recycled oceanic lithosphere. This review of the geochemistry of Hawaiian depleted components documents the need for the sampling of multiple distinctive depleted compositions, each preferentially melted during specific periods of Hawaiian plume activity. This suggests that the composition of depleted components can evolve during the lifetime of the mantle plume, as observed for enriched components in the Hawaiian mantle plume. Changes in the composition of depleted components are dominantly controlled by the upper mantle tectonic configurations at the time of eruption (i.e., proximity to a mid-ocean ridge), as this effect overwhelms the signal imparted by potentially sampling different lower mantle components through time.

07 ISOTOPE AND RADIATION SOURCES↗

Toward an Understanding of Surface Layer Formation, Growth, and Transformation at the Glass–Fluid Interface

Silicate glass is a metastable and durable solid that has application to a number of energy and environmental challenges (e.g., microelectronics, fiber optics, and nuclear waste storage). If allowed to react with water over time silicate glass develops an altered layer at the solid-fluid interface. In this study, we used borosilicate glass (LAWB45) as model material to develop a robust understanding of altered layer formation (i.e., amorphous hydrated surface layer and crystalline reaction products). Experiments were conducted at high surface area-to-volume ratio (~200,000 m-1) and 90 °C in the pressurized unsaturated flow (PUF) apparatus for 1.5-years to facilitate the formation of thick altered layers and allow for the effluent solution chemistry to be monitored continuously. A variety of microscopy techniques were used to characterized reacted grains and suggest the average altered layer thickness is 13.2 ± 8.3 μm with the hydrated and clay layer representing 74.8% and 25.2% of the total altered layer, respectively. This estimate is within the experimental error of the value estimated from the B release rate data (~10 ±1 μm/yr) over the 1.5-year duration. PeakForce® quantitative nanomechanical mapping results suggest the hydrated layer has a modulus that ranges between ~20 to 40 GPa, which is in the range of porous silica that contains from ~20 to ~50% porosity, yet significantly lower than dense silica (~70 to 80 GPa). Scanning transmission electron microscopy (STEM) images confirm the presence of pores and an analysis of a higher resolution image of a region provides a qualitative estimate of ≥ 22% porosity in this layer with variations in the hydrated layer in void volume with increasing distance from the unaltered glass. Chemical composition analyses, based on a combination of time-of-flight secondary-ion mass spectrometry (ToF-SIMS) and scanning electron microscopy with X-ray energy dispersive spectroscopy (EDS) and STEM-EDS, clearly show that the altered layer is mainly composed of Al, H, Si, and O with the clay layer being enriched in Li, Zn, Fe, and Mg. The amorphous hydrated layer is enriched in Ca, H, and Zr with a minor amount of K. Furthermore, ToF-SIMS results also suggest the B profile is anti-correlated with the H profile in the hydrated layer. Our selected-area electron diffraction results suggest the structure of the hydrated layer closely resembles opal-AG (amorphous gel-like) with an average crystallite size of ~0.7 nm which is smaller than the critical nucleus for silica nanoparticles (i.e., 1.4 to 3 nm). These results suggest the hydrated layer is more consistent with a polymeric gel rather than a colloidal gel and is comprised of molecular units (<1 nm in size) that result from the difficult to hydrolyze bonds, such as Si—O—Zr units, during the glass corrosion process. The size of individual particles or molecular units is a function of formation conditions (e.g., pH, ionic strength, nano-confinement, solute composition) in the hydrated layer.

36 MATERIALS SCIENCE↗

An approach to assessing stochastic radiogenic risk in medical imaging

Purpose: This letter suggests a formalism, the medical effective dose (MED), that is suitable for assessing stochastic radiogenic risks in diagnostic medical procedures. Methods: The MED is derived from radiobiological and probabilistic first principals, including: (1) The independence of radiation-induced biological effects in neighboring voxels at low doses; (2) the linear no-threshold assumption for stochastic radiation injury (although other dose-response relationships could be incorporated, instead); (3) the best human radiation dose-response data currently available; and (4) the built-in possibility that the carcinogenic risk to an irradiated organ may depend on its volume. The MED involves a dose-risk summation over irradiated voxels at high spatial resolution; it reduces to the traditional effective dose when every organ is irradiated uniformly and when the dependence of risk on organ volumes is ignored. Standard relative-risk tissue weighting factors can be used with the MED approach until more refined data become available. Results: The MED is intended for clinical and phantom dosimetry, and it provides an estimate of overall relative radiogenic stochastic risk for any given dose distribution. A result of the MED derivation is that the stochastic risk may increase with the volume of tissue (i.e., the number of cells) irradiated, a feature that can be activated when forthcoming radiobiological research warrants it. In this regard, the MED resembles neither the standard effective dose (E) nor the CT dose index (CTDI), but it is somewhat like the CT dose-length product (DLP). Conclusions: The MED is a novel, probabilistically and biologically based means of estimating stochastic-risk-weighted doses associated with medical imaging. Built in, ab initio, is the ability to link radiogenic risk to organ volume and other clinical factors. It is straightforward to implement when medical dose distributions are available, provided that one is content, for the time being, to accept the relative tissue weighting factors published by the International Commission of Radiological Protection (ICRP). It requires no new radiobiological data and avoids major problems encountered by the E, CTDI, and CT-E formalisms. It makes possible relative inter-patient dosimetry, and also realistic intercomparisons of stochastic risks from different protocols that yield images of comparable quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-135: Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

Purpose: To estimate the clinical relevance of approximations made in analytical dose calculation methods (ADCs) used for treatment planning on tumor coverage and tumor control probability (TCP) in proton therapy. Methods: We compared dose distributions planned with ADC to delivered dose distributions (as determined by TOPAS Monte Carlo (MC) simulations). We investigated 10 patients per site for 5 treatment sites (head-and-neck, lung, breast, prostate, liver). We evaluated differences between the two dose distributions analyzing dosimetric indices based on the dose-volume-histograms, the γ-index and the TCP. The normal tissue complication probability (NTCP) was estimated for the bladder and anterior rectum for the prostate patients. Results: We find that the target doses are overestimated by the ADC by 1–2% on average for all patients considered. All dosimetric indices (the mean dose, D95, D50 and D02, the dose values covering 95%, 50% and 2% of the target volume, respectively) are predicted within 5% of the delivered dose. A γ-index with a 3%/3mm criteria had a passing rate for target volumes above 96% for all patients. The TCP predicted by the two algorithms was up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head-and-neck and lung patients, respectively. Differences in NTCP for anterior-rectum and bladder for prostate patients were less than 3%. Conclusion: We show that ADC provide adequate dose distributions for most patients, however, they can Result in underdosage of the target by as much as 5%. The TCP was found to be up to 11% lower than predicted. Advanced dose-calculation methods like MC simulations may be necessary in proton therapy to ensure target coverage for heterogeneous patient geometries, in clinical trials comparing proton therapy to conventional radiotherapy to avoid biases due to systematic discrepancies in calculated dose distributions, and, if tighter range margins are considered. Fully funded by NIH grants.

60 APPLIED LIFE SCIENCES↗

MASKED AREAS IN SHEAR PEAK STATISTICS: A FORWARD MODELING APPROACH

The statistics of shear peaks have been shown to provide valuable cosmological information beyond the power spectrum, and will be an important constraint of models of cosmology in forthcoming astronomical surveys. Surveys include masked areas due to bright stars, bad pixels etc., which must be accounted for in producing constraints on cosmology from shear maps. We advocate a forward-modeling approach, where the impacts of masking and other survey artifacts are accounted for in the theoretical prediction of cosmological parameters, rather than correcting survey data to remove them. We use masks based on the Deep Lens Survey, and explore the impact of up to 37% of the survey area being masked on LSST and DES-scale surveys. By reconstructing maps of aperture mass the masking effect is smoothed out, resulting in up to 14% smaller statistical uncertainties compared to simply reducing the survey area by the masked area. We show that, even in the presence of large survey masks, the bias in cosmological parameter estimation produced in the forward-modeling process is ≈1%, dominated by bias caused by limited simulation volume. We also explore how this potential bias scales with survey area and evaluate how much small survey areas are impacted by the differences in cosmological structure in the data and simulated volumes, due to cosmic variance.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-207B-09: Margin Reduction for Planning Target Volume (PTV) in Patients with Localized Prostate Cancer: Impact On Delivered Dose and Quality of Life

Purpose: To estimate the delivered (cumulative) dose to targets and organs at risk for localized prostate cancer patients treated with reduced PTV margins and to evaluate preliminary patient reported quality-of-life (QOL). Methods: Under an IRB-approved protocol, 20 prostate cancer patients (including 11 control patients) were treated with reduced planning margins (5 mm uniform with 4 mm at prostate/rectum interface). Control patients had standard margin (10/6 mm)-based treatments. A parameter-optimized Elastix algorithm along with energy-mass mapping was used to deform and resample dose of the day onto the planning CT for each fraction to estimate the delivered dose over all fractions. QOL data were collected via Expanded Prostate cancer Index Composite (EPIC-26) questionnaires at time points pre-treatment, post-treatment, and at 2, 6, 12, 18 month follow-ups. Standardized QOL scores [range: 0–100] were determined and baseline-corrected by subtracting pre-treatment QOL data. Mean QOL differences between the margin reduced group and control group (QOLmr-QOLcontrol) were calculated for first 18 months. Results: The difference between the cumulative mean dose (Dmean) and the planned mean dose (±SD) for PTV, prostate, bladder, and rectum were −2.2±1.0, 0.3±0.5, −0.7±2.6, and −2.1±1.3 Gy respectively for the margin-reduced group, and −0.8±2.0, 0.9±1.4, - 0.7±3.1 and −1.0±2.4 Gy for the control group. Difference between the two groups was statistically insignificant (p=0.1). Standardized and baseline corrected QOLmr-QOLcontrol for EPIC domains categorized as “Urinary Incontinence”, “Urinary Irritative/Obstructive”, “Bowel”, “Sexual”, and “Hormonal” were 0.6, 12.1, 9.1, 13.3, and −0.9 for the 18 months following radiation therapy (higher values better). Delivered dose to rectum showed a weak correlation to “Bowel” domain (Pearson’s coefficient −0.24, p<0.001), while bladder dose did not correlate to Urinary Incontinence/Irritative/Obstructive QOL domains. Conclusion: The margin-reduced group exhibited clinically meaningful improvement of QOL without compromising the PTV dose. A larger number of patients and greater follow-up is needed to draw unequivocal conclusions. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Shuttle/Agena study. Volume 2, part 3: Preliminary test plans

Proposed testing for the Agena tug program is based upon best estimates of shuttle and Agena tug requirements and upon the Agena configuration currently envisioned to meet these requirements. The proposed tests are presented in development, qualification, system, and launch base test plans. These plans are based upon generalized requirements and assumed situations. The limitations of this study precluded all but minimal consideration of related shuttle orbiter and shuttle ground systems. The test plans include provisions for all testing from major component to systems level, identified as necessary to aid in confirmation of the modified Agena configuration for the space tug; considerations that crew safety requirements and new environmental conditions from shuttle interface effects do impose some new Agena testing requirements; considerations that many existing Agena flight-qualified components will be utilized and qualification testing will be minimal; testing not only for the Agena tug but also for new or modified items of handling or servicing equipment for supporting the Agena factory-to-launch sequence; and the assembly of required testing into a sequence-ordered series of events.

Source record↗

AgRISTARS. Preliminary technical results review of FY81 experiments, volume 2: Fiscal year 1981/1982 "corn and soybeans pilot" experiment

The performance of the technology exhibited significant proportion estimation errors, specifically, high mean error in both corn and soybeans area estimation. The data systems, technical approaches, and data assessment of the pilot experiment were reviewed. Results of proportion estimations procedure performance evaluations, and sensitivity evaluations are presented. The role of the pilot experiment in foreign technology development is discussed.

Source record↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗