Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Stirling Convertor Dynamic Test Approach and Results

The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Convertors (ASC) at NASA GRC undergo a vibration test sequence intended to simulate the vibration history that an ASC would experience when used in an ASRG for a space mission. This sequence includes testing at workmanship and flight acceptance levels interspersed with periods of extended operation to simulate prefueling and post fueling. The final step in the test sequence utilizes additional testing at flight acceptance levels to simulate launch. To better replicate the acceleration profile seen by an ASC incorporated into an ASRG, the input spectra used in testing the convertors was modified based on dynamic testing of the ASRG Engineering Unit (ASRG EU) at LM. This paper outlines the overall test approach, summarizes the test results from the ASRG EU, describes the incorporation of those results into the test approach, and presents the results of applying the test approach to the ASC-1 #3 and #4 convertors. The test results include data from several accelerometers mounted on the convertors as well as the piston position and output power variables.

Meer, David W.↗

RAVIS: Resource Forecast and Ramp Visualization for Situational Awareness of Variable Renewable Generation

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an innovative, open-source tool for visualizing variable renewable resource forecasts and alerts for significant up- and down-ramps in renewable generation and the consequent system net load. The modular dashboard of RAVIS contains configurable panes for viewing probabilistic time-series forecasts, ramp event alerts on the look-ahead timeline, and spatially resolved resource sites, and forecasts. For comprehensive situational awareness, the tool can add additional data layers from simulation and independent system operator (ISO) market clearing data---including electric line utilization, nodal price, and available generation flexibility---in response to continuously updated renewable forecasts. This paper introduces the RAVIS technology suite employed to provide optimum visualization and flexible design characteristics. The paper also illustrates some use cases of the tool using site-specific solar power forecast data obtained from the IBM Watt-Sun forecasting platform for the California ISO and Midcontinent ISO footprints. The source code for RAVIS is public (https://github.com/ravis-nrel/ravis), and the intended users are forecasters, utility planners, ISO operators, and researchers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

DSCOVR/EPIC-derived global hourly and daily downward shortwave and photosynthetically active radiation data at 0.1° × 0.1° resolution

Downward shortwave radiation (SW) and photosynthetically active radiation (PAR) play crucial roles in Earth system dynamics. Spaceborne remote sensing techniques provide a unique means for mapping accurate spatiotemporally continuous SW–PAR, globally. However, any individual polar-orbiting or geostationary satellite cannot satisfy the desired high temporal resolution (sub-daily) and global coverage simultaneously, while integrating and fusing multisource data from complementary satellites/sensors is challenging because of co-registration, intercalibration, near real-time data delivery and the effects of discrepancies in orbital geometry. The Earth Polychromatic Imaging Camera (EPIC) on board the Deep Space Climate Observatory (DSCOVR), launched in February 2015, offers an unprecedented possibility to bridge the gap between high temporal resolution and global coverage and characterize the diurnal cycles of SW–PAR globally. In this study, we adopted a suite of well-validated data-driven machine-learning models to generate the first global land products of SW–PAR, from June 2015 to June 2019, based on DSCOVR/EPIC data. The derived products have high temporal resolution (hourly) and medium spatial resolution (0.1°×0.1°), and they include estimates of the direct and diffuse components of SW–PAR. We used independently widely distributed ground station data from the Baseline Surface Radiation Network (BSRN), the Surface Radiation Budget Network (SURFRAD), NOAA's Global Monitoring Division and the U.S. Department of Energy's Atmospheric System Research (ASR) program to evaluate the performance of our products, and we further analyzed and compared the spatiotemporal characteristics of the derived products with the benchmarking Clouds and the Earth's Radiant Energy System Synoptic (CERES) data. We found both the hourly and daily products to be consistent with ground-based observations (e.g., hourly and daily total SWs have low biases of -3.96 and -0.71 W m -2 and root-mean-square errors (RMSEs) of 103.50 and 35.40 W m -2 , respectively). The developed products capture the complex spatiotemporal patterns well and accurately track substantial diurnal, monthly, and seasonal variations in SW–PAR when compared to CERES data. They provide a reliable and valuable alternative for solar photovoltaic applications worldwide and can be used to improve our understanding of the diurnal and seasonal variabilities of the terrestrial water, carbon and energy fluxes at various spatial scales.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Converter Performance Considering Static and Dynamic Device Part-to-Part Variability

This paper presents a methodology to incorporate and analyze the impact of semiconductor device part-to-part variation on power converter performance. By integrating extensive static and dynamic device characterization data with an automated compact model generation process that reflects manufacturing variability, device models with inherent variability features are utilized in converter simulations for a comprehensive assessment of performance impacts. The traditional converter performance evaluation process typically yields fixed efficiency values, often dismissing the inherent part-to-part variability caused by the manufacturing process of semiconductor devices. To address this limitation, a large population of devices was characterized to capture variations in static parameters-such as transfer, output, and capacitance characteristics-as well as dynamic behaviors, including switching losses. This data-driven approach enables the development of individual compact models, which were then integrated into converter simulations to evaluate efficiency ranges rather than single point estimated values. The converter simulation results show that part-to-part component variation can lead to significant efficiency deviations, exceeding several percentage points in high-power conversion applications. By offering a more accurate representation of converter behavior under real-world manufacturing conditions, this methodology enables designers to anticipate performance variability, improving the robustness of power converter designs.

device characterization↗

Turbulence statistical analysis of the L-H transition and RMPs in KSTAR

Here, we investigate the turbulence statistics associated with low-to-high confinement (L-H) transitions and externally applied resonant magnetic perturbations (RMPs) in KSTAR. Time-series fluctuations of electron density n e , electron temperature T e , and the time derivative of the poloidal magnetic field dB θ /dt (Mirnov coils) are analysed using information-geometric measures (information rate Γ and information length $\mathcal{L}$ = ∫ Γ dt), together with kurtosis κ and variance σ 2 . In low-density upper single-null plasmas (n e ~ 1.2 x 10 19 m -3 ), a ~80 kHz magnetic mode coupling n e , T e , dB θ /dt and emerges prior to the L-H transition and persists into the edge-localised modes H-mode. Edge-localised RMPs (ERMPs) suppress this coherent mode but enhance intermittency, producing frequent bursts that abruptly reshape the time-dependent probability density functions (PDFs) and generate large spikes in Γ (with smaller changes in κ), signalling ERMP-driven departures from quasi-stationarity. The impact of ERMPs on background fluctuation levels depends on density, radial location, and the fluctuating variable itself ($\tilde{n}$, $\tilde{T}$, $\dot{B}$ θ ), whereas $\mathcal{L}$ provides a robust, regime-agnostic measure of cumulative statistical reorganisation and spatial decorrelation. In particular, at low density we observe weaker coupling between $\tilde{n}$ and $\tilde{T}$, along with a tendency toward decreased radial correlation-most clearly for $\tilde{T}$-under ERMPs. Overall, information geometry cleanly captures intermittent events, quantifies non-equilibrium PDF evolution, and offers a compact, cross-diagnostic metric for assessing resonant magnetic perturbation effects on edge transport and correlation across densities, radial locations, and confinement states.

Kim, Eun-jin [Coventry Univ. (United Kingdom); Seo↗

Measurement of Deformation Heterogeneity During Shale Swelling Using Digital Image Correlation

Abstract Rock-fluid interactions in shale formations are one of the main sources of wellbore instability issues and inadequate stimulation performance. For better planning of fracturing operations and optimizing production from these reservoirs, it is important to understand the mechanisms behind these interactions. These issues are especially prevalent in clay-rich shales, such as Tuscaloosa Marine Shale, which is the subject of this study. Conventional techniques to quantify these shale-fluid interactions comprise of measuring swelling in powdered rock grains or measurement of deformation in the whole pieces of the core using a linear variable differential transformer and strain gages. However, the contribution from individual laminae to overall deformation cannot be evaluated using these methods. In this study, we developed an experimental setup to evaluate the spatial deformation in shale during interaction with water using digital image correlation (DIC). Deformation of two shale samples, with 34 wt% to 51 wt% clay content, was studied. White paint was used to generate a random speckle pattern on the specimen and then immersed in deionized water. The deformation process was captured using a digital camera and images were analyzed using DIC to quantify the deformation. The implementation of the DIC technique enables the visualization and quantification of spatial deformation in the specimen during interacting with water. The results show the localization of large strains in select laminations. The results provide a better understanding of shale deformation when interacting with water in comparison to traditional measurements that can provide only an average strain value.

Energy & Fuels↗

Soil Surface Runoff Scheme for Improving Land-Hydrology and Surface Fluxes in Simple SiB (SSiB)

Evapotranspiration on land is hard to measure and difficult to simulate. On the scale of a GCM grid, there is large subgrid-scale variability of orography, soil moisture, and vegetation. Our hope is to be able to tune the biophysical constants of vegetation and soil parameters to get the most realistic space-averaged diurnal cycle of evaporation and its climatology. Field experiments such as First ISLSCP Field Experiment (FIFE), Boreal Ecosystem-Atmosphere Study (BOREAS), and LBA help a great deal in improving our evapotranspiration schemes. However, these improvements have to be matched with, and coupled to, consistent improvement in land-hydrology; otherwise, the runoff problems will intrinsically reflect on the soil moisture and evapotranspiration errors. Indeed, a realistic runoff simulation also ensures a reasonable evapotranspiration simulation provided the precipitation forcing is reliable. We have been working on all of the above problems to improve the simulated hydrologic cycle. Through our participation in the evaluation and intercomparison of land-models under the behest of Global Soil Wetness Project (GSWP), we identified a few problems with Simple SiB (SSIB; Xue et al., 1991) hydrology in regions of significant snowmelt. Sud and Mocko (1999) show that inclusion of a separate snowpack model, with its own energy budget and fluxes with the atmosphere aloft and soil beneath, helps to ameliorate some of the deficiencies of delayed snowmelt and excessive spring season runoff. Thus, much more realistic timing of melt water generation was simulated with the new snowpack model in the subsequent GSWP re-evaluations using 2 years of ISLSCP Initiative I forcing data for 1987 and 1988. However, we noted an overcorrection of the low meltwater infiltration of SSiB. While the improvement in snowmelt timing was found everywhere, the snowmelt infiltration has became excessive in some regions, e.g., Lena river basin. This leads to much reduced runoff in many basins as compared to observations. We believe this is a consequence of neglect of the influence of subgrid-scale variations in orography that affects the production of surface runoff.

Sud, Y. C.↗

RAVIS: Resource Forecast and Ramp Visualization for Situational Awareness of Variable Renewable Generation: Preprint

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an innovative, open-source tool for visualizing variable renewable resource forecasts and alerts for significant up- and down-ramps in renewable generation and the consequent system net load. The modular dashboard of RAVIS contains configurable panes for viewing probabilistic time-series forecasts, ramp event alerts on the look-ahead timeline, and spatially resolved resource sites, and forecasts. For comprehensive situational awareness, the tool can add additional data layers from simulation and independent system operator (ISO) market clearing data—including electric line utilization, nodal price, and available generation flexibility—in response to continuously updated renewable forecasts. This paper introduces the RAVIS technology suite employed to provide optimum visualization and flexible design characteristics. The paper also illustrates some use cases of the tool using site-specific solar power forecast data obtained from the IBM Watt-Sun forecasting platform for the California ISO and Midcontinent ISO footprints. The source code for RAVIS is public (https://github.com/ravis-nrel/ravis), and the intended users are forecasters, utility planners, ISO operators, and researchers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Industry Partnerships & Their Role In Reducing Natural Gas Supply Chain Greenhouse Gas Emissions – Phase 2

This analysis is the product of collaboration between Our Nation’s Energy Future (ONE Future) and the United States (U.S.) Department of Energy (DOE) National Energy Technology Laboratory (NETL). This analysis is an update to Phase 1 of the collaboration between ONE Future and NETL. Phase 1 had three objectives: 1. Calculate a greenhouse gas (GHG) emission profile representative of ONE Future’s supply chain, including methane (CH 4 ) emission rates. 2. Compare ONE Future’s emission profile to the emission profile for the U.S. natural gas supply chain. 3. Evaluate specific emission reduction opportunities. Phase 2 has two key enhancements over Phase 1: 1. The reporting year of the data is updated from 2016 to 2017. 2. The emission profiles and the specific emission reduction opportunities are regionalized for the ONE Future supply chain. The ONE Future supply chain is based on data provided by ONE Future members for all their U.S. onshore assets. ONE Future’s data are mostly representative of their participation in the Greenhouse Gas Reporting Program (GHGRP) administered by the Environmental Protection Agency (EPA) and is supplemented by ONE Future facilities that are not required to report to GHGRP. The U.S. scenario is based on NETL’s life cycle analysis (LCA) of natural gas extraction and power generation, which also uses data from the GHGRP (but does not include non-GHGRP facilities). In addition to the data from these sources, NETL accounted for uncertainty due to data variability, data limitations, and variability in liquids unloading frequency and event duration. This report is a re-issue of the 2020 study (published on July 28, 2020). It revises the device count in the mitigation strategy “pipeline pump-down before maintenance” in the Marginal Abatement Cost (MAC) Analysis section of the report (Section 7). Please see the addendum for more details on this revision and resultant changes. This revision does not change most of our conclusions and recommendations. It only changes the total methane reduced from all the mitigation opportunities (low cost and high cost) from 6.5 Bcf CH 4 /yr to 4.8 Bcf CH 4 /yr.

03 NATURAL GAS↗

Representing surface heterogeneity in land–atmosphere coupling in E3SMv1 single-column model over ARM SGP during summertime

Abstract. The Earth's land surface features spatial and temporal heterogeneity over a wide range of scales below those resolved by current Earth system models (ESMs). State-of-the-art land and atmosphere models employ parameterizations to represent their subgrid heterogeneity, but the land–atmosphere coupling in ESMs typically operates on the grid scale. Communicating the information on the land surface heterogeneity with the overlying atmospheric boundary layer (ABL) remains a challenge in modeling land–atmosphere interactions. In order to account for the subgrid-scale heterogeneity in land–atmosphere coupling, we implement a new coupling scheme in the Energy Exascale Earth system model version 1 (E3SMv1) that uses adjusted surface variances and covariance of potential temperature and specific water content as the lower boundary condition for the atmosphere model. The new lower boundary condition accounts for both the variability of individual subgrid land surface patches and the inter-patch variability. The E3SMv1 single-column model (SCM) simulations over the Atmospheric Radiation Measurement (ARM) Southern Great Plain (SGP) site were performed to assess the impacts. We find that the new coupling parameterization increases the magnitude and diurnal cycle of the temperature variance and humidity variance in the lower ABL on non-precipitating days. The impacts are primarily attributed to subgrid inter-patch variability rather than the variability of individual patches. These effects extend vertically from the surface to several levels in the lower ABL on clear days. We also find that accounting for surface heterogeneity increases low cloud cover and liquid water path (LWP). These cloud changes are associated with the change in cloud regime indicated by the skewness of the probability density function (PDF) of the subgrid vertical velocity. In precipitating days, the inter-patch variability reduces significantly so that the impact of accounting for surface heterogeneity vanishes. These results highlight the importance of accounting for subgrid heterogeneity in land–atmosphere coupling in next-generation ESMs.

54 ENVIRONMENTAL SCIENCES↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

A Regional-Scale Assessment of Satellite Derived Precipitable Water Vapor Across The Amazon Basin

Atmospheric water vapor is widely recognized as a key climate variable, linking an assortment of poorly understood and complex processes. It is a major element of the hydrological cycle and provides a mechanism for energy exchange among many of the Earth system components. Reducing uncertainty in our current knowledge of water vapor and its role in the climate system requires accurate measurement, improved modeling techniques, and long-term prediction. Satellites have the potential to satisfy these criteria, as well as provide high resolution measurements that are not available from conventional sources. The focus of this paper is to examine the temporal and mesoscale variations of satellite derived precipitable water vapor (PW) across the Amazon Basin. This region is pivotal in the functioning of the global climate system through its abundant release of latent heat associated with heavy precipitation events. In addition, anthropogenic deforestation and biomass burning activities in recent decades are altering the conditions of the atmosphere, especially in the planetary boundary layer. A physical split-window (PSW) algorithm estimates PW using images from the GOES satellites along with the NCEP/NCAR Reanalysis data that provides the first guess information. Retrievals are made at a three-hourly time step during daylight hours in the Amazon Basin and surrounding areas for the months of June and October in 1988 (dry year) and 1995 (wet year). Spatially continuous fields are generated 5 times daily at 12Z, 15Z, 18Z, 21Z, and 00Z. These fields are then averaged to create monthly and 3 hourly monthly grids. Overall, the PSW estimates PW reasonable well in the Amazon with MAE ranging from 3.0 - 9.0 mm and MAE/observed mean around 20% in comparison to radiosonde observations. The distribution of PW generally mimics that of precipitation. Maximum values (42 - 52 mm) are located in the Northwest whereas minimum values (18 - 27 mm) are found along Brazil's East coast. Aside from the East coast, PW has a stronger north-south gradient than that of rainfall. As for the temporal variation of PW, June (1988 and 1995) experiences a peak about 1400 local time, corresponding to a maximum in air temperature. In contrast, October (1988 and 1995) experiences a maximum early in the day, 1100 local time, with a gradual decrease toward nighttime.

DeLiberty, Tracy↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Landscape-scale Characterization of Arctic Tundra Vegetation Composition, Structure, and Function with a Multi-sensor Unoccupied Aerial System: Supporting Data.

Airborne remote sensing data collected using the Brookhaven National Laboratory's (BNL) heavy-lift unoccupied aerial system (UAS) octocopter platform, the Osprey, operated by the Terrestrial Ecosystem Science and Technology (TEST) group (https://www.bnl.gov/testgroup). This package includes data from three flights flown over the NGEE-Arctic Council, Kougarok and Teller sites in July, 2018. The Osprey is a multi-sensor UAS platform that simultaneously measures very high spatial resolution optical red/green/blue (RGB) and thermal infrared (TIR) surface 'skin' temperature imagery, as well as surface reflectance at 1 nm intervals in the visible to near-infrared spectral range 350 - 1000 nm measured at regular intervals along each flight path. Derived image products include ortho-mosaiced RGB and TIR images, an RGB-based digital surface model (DSM) using the structure from motion (SfM) technique, digital terrain model (DTM), and a canopy height model (CHM). In addition, a VNIR surface reflectance file is provided for the trigger locations collected during each flight campaign. Ancillary aircraft data, flight mission parameters, and general flight conditions provided by the onboard flight and data collection computers are also included. Unprocessed and processed data products are included in this package (processing levels 0-3). Data and metadata are provided as text (*.txt, *.json, *.kml, *hdr, *.enp), tabular (*.dat, *.csv, *.waypoint, ENVI format (no extension)), point cloud (*.laz) and image (*.jpg, *.tif, *png) formats. This metadata document contains flight campaign, instrument and file metadata, along with a description of data processing levels, data products and file naming scheme.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy?s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗