Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

First constraints on WIMP-nucleon effective field theory couplings in an extended energy region from LUX-ZEPLIN

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead, South Dakota, USA, we report the initial limits on a model-independent nonrelativistic effective field theory describing the complete set of possible interactions of a weakly interacting massive particle (WIMP) with a nucleon. These results utilize the same 5.5 t fiducial mass and 60 live days of exposure collected for the LZ spin-independent and spin-dependent analyses while extending the upper limit of the energy region of interest by a factor of 7.5 to 270 keV. No significant excess in this high energy region is observed. Using a profile-likelihood ratio analysis, we report 90% confidence level exclusion limits on the coupling of each individual nonrelativistic WIMP-nucleon operator for both elastic and inelastic interactions in the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

Test of nuclear decay rate variation due to an antineutrino flux

Unexplained variations of the decay rate parameter for weak interaction decays such as β ± decay, electron capture, as well as strong interaction α decay have been reported. Because these variations have been presented by a number of groups, at various locations, using various types of detectors, different isotopes, and over extended periods of time, some researchers have interpreted the source of these variations as not from ambient environmental factors such as temperature, pressure, and humidity but via an unexplained fundamental interaction. The state of decay rate parameter variations experiments is reviewed, and the reported results are placed into a common comparable context by defining a phenomenological cross section. After that we make decay parameter measurements as a function of time at the level of 10 -5 in the presences of an antineutrino flux with an on-off cycle time of ≈ 30 days. This level of precision requires a detailed understanding of both systematic and statistical errors; otherwise, systematic errors in the measurement may mimic the decay events of fundamental interactions. The experiment searched for variation of the $^{54}_{25}$Mn, e - capture decay rate parameter and $^{137}_{55}$Cs, β - decay rate parameter both to a level of precision of 1 part in ≈10 5 by comparing the difference between the decay rate in the presence of an antineutrino flux ≈ 3 x 10 12 $\bar{ν}$ cm -2 s -1 and no flux measurements. The experiment was located 6.53 m from the reactor core of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Two weak interaction decays, one via electron capture and the other via β - decay, were selected because the final state and the time reverse state each contain a neutrino and antineutrino, covering arguments that the antineutrino flux may interact differently or not at all in one of the cases. The $\gamma$ spectra from both decays were collected and analyzed independently. The measured variation in the decay rate parameters are found to be δλ/λ =(0.034 ± 1.38) x10 -5 for $^{54}_{25}$Mn and δλ/λ =(0.67±1.56) x10 -5 for $^{137}_{55}$Cs. These results are consistent with no measurable decay rate parameter variation due to an antineutrino flux, yielding a 68% confidence level upper limit sensitivity for $^{54}_{25}$Mn δλ/λ ≤ 1.31 x 10 -5 or σ ≤ 1.29 x10 -25 cm 2 in cross section and for $^{137}_{55}$Cs δλ/λ ≤ 2.23 x 10 -5 or σ ≤ 5.69 x10 -27 cm 2 . The cross-section upper limit obtained in these null or no observable effect measurements are ≈ 10 4 times more sensitive than past experiments reporting positive results in 54 Mn and 137 Cs. . .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The hidden ion population of the magnetosphere

The presence of a cold ion population in the magnetosphere which is normally hidden from particle detector observation by the positive charging of the spacecraft is reported. Ion and electron data were obtained from particle detectors on the ATS 6 and SCATHA satellites designed to measure the 1-eV to 80-keV plasma population. The cold, isotropic ion population, with temperature 1 eV and density 10-100/cu cm, was detected only when the spacecraft were in eclipse, when spacecraft potential had dropped from +10 V in sunlight to +4 to +5 V. The hidden ion population was found at geosynchronous altitude only during geomagnetically quiet times and when there has been an absence of geomagnetic activity for several hours, and appears to coexist with the plasma sheet. More consistent measurements of the cold ion population at midnight or at other local times would require the biasing of the ion detector with respect to the spacecraft, or the controlling of spacecraft potential.

Olsen, R. C.↗

Search for Low mass Higgs Portal Scalars at the MicroBooNE Detector in the NuMI Beam

The MicroBooNE experiment exploits Liquid Argon Time Projection Chamber (LArTPC) technology to detect neutrinos from two beams at Fermilab, Chicago: on-axis Booster Neutrino Beam (BNB) and the off-axis Neutrinos at the Main Injector (NuMI) beam. While the aim of the experiment is to study the low-energy excess of electron neutrino events observed by the MiniBooNE experiment, to search for eV-scale sterile neutrinos and to characterise neutrino interactions on argon, it could also be exploited to probe Beyond Standard Model (BSM) Physics. This thesis presents a BSM search for low-mass Higgs Portal Scalars at MicroBooNE in the NuMI beam using data collected during the Run 1 and Run 3 data-taking periods with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target (POT). The Higgs Portal Model is an extension to the Standard Model in which a dark-sector scalar, $S$, mixes with the Higgs boson with mixing angle $\theta$ and acquires a coupling to the Standard Model fermions via the Higgs Yukawa coupling. We search for low-mass Higgs Portal scalars, in the mass range $100-200$ MeV, at MicroBooNE via the production channel $K \rightarrow \pi + S$, where scalars are produced from kaons decaying at rest in the NuMI target and beam dump, as well as kaons decaying in flight in the decay pipe of the NuMI beam. In the MicroBooNE detector, we search for the decay channel $S \rightarrow e^+e^-$, which is the only decay channel available to the scalars in the mass range of our search. The results are expressed as limits, at the 95\% confidence level, on the scalar-Higgs mixing angle $\theta$ for scalars in the mass range $100-200$ MeV.Date of Award1 Aug 2023Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometric correction process for the Landsat-4 Thematic Mapper

The processing approaches which form the basis of the Landsat-4 Thematic Mapper (TM) geometric correction system are summarized. The correction is accomplished in two phases. In the first phase, correction data are generated. The spacecraft position, TM frame attitude, TM scanning mirror position, and detector sampling are found as a function of time through a combination of flight segment measurements, ground segment modeling, and control point information. The data, along with the earth position and geoid model, are used to determine the earth location for each TM image sample. Then, using map projections, correction data can be generated which define the location of each TM image sample on the output coordinate system. In the second phase, the correction data are used to resample TM detector samples onto the output coordinate system.

Beyer, E. P.↗

Predicting Chandra CCD Degradation with the Chandra Radiation Model

Not long after launch of the Chandra X-Ray Observatory, it was discovered that the Advanced CCD Imaging Spectrometer (ACIS) detector was rapidly degrading due to radiation. Analysis by Chandra personnel showed that this degradation was due to 10w energy protons (100 - 200 keV) that scattered down the optical path onto the focal plane. In response to this unexpected problem, the Chandra Team developed a radiation-protection program that has been used to manage the radiation damage to the CCDs. This program consists of multiple approaches - scheduled sating of the ACIS detector from the radiation environment during passage through radiation belts, real-time monitoring of space weather conditions, on-board monitoring of radiation environment levels, and the creation of a radiation environment model for use in computing proton flux and fluence at energies that damage the ACIS detector. This radiation mitigation program has been very successful. The initial precipitous increase in the CCDs' charge transfer inefficiency (CTI) resulting from proton damage has been slowed dramatically, with the front-illuminated CCDS having an increase in CTI of only 2.3% per year, allowing the ASIS detector's expected lifetime to exceed requirements. This paper concentrates on one aspect of the Chandra radiation mitigation program, the creation of the Chandra Radiation Model (CRM). Because of Chandra's highly elliptical orbit, the spacecraft spends most of its time outside of the trapped radiation belts that present the severest risks to the ACIS detector. However, there is still a proton flux environment that must be accounted for in all parts of Chandra's orbit. At the time of Chandra's launch there was no engineering model of the radiation environment that could be used in the outer regions of the spacecraft's orbit, so the CRM was developed to provide the flux environment of 100 - 200 keV protons in the outer magnetosphere, magnetosheath, and solar wind regions of geospace. This presentation describes CRM, its role in Chandra operations, and its prediction of the ACIS CTI increase.

Minow, Joseph I.↗

Production and tests of the ADDC for the Micromegas detector of the ATLAS New Small Wheel

The Large Hadron Collider (LHC) at CERN will perform a series of upgrades to allow luminosity increases during the next physics runs expected from 2022 on. These will also significantly increase the trigger rates of all the detectors. As part of the ATLAS Phase-I upgrade, the current Small Wheel muon detectors will be replaced with state-of-the-art New Small Wheel (NSW) detectors to cope with the increased luminosity of the LHC. The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data from the resistive Micro-Mesh Gaseous Structure (Micromegas) detectors of the NSW. The ART ASIC on the ADDC is a customdesigned chip to receive theAddress in Real Time (ART) signals from theVMMfront-end ASIC and perform hit-selection processing. The processed trigger data is then sent to the Trigger Processor (TP) through optical links. A total of 512 ADDCs will be installed on the detector close to the front-end boards. Therefore, those cards must be able to work properly in a high radiation and magnetic field environment. Furthermore, after four rounds of prototyping, the ADDC production was launched in January of 2019. 600 ADDC boards have been produced and tested with an automated test stand. This test setup can simulate the front-end signals and provide "Level-1 Data Driver Card" (L1DDC) functions as well as part of the TP functions. Thus, the ADDC functionality and stability can be verified without the remaining NSW electronics. This paper describes the ADDC hardware prototype development, radiation and integration testing, and the ADDC automated production test procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

Developing a data-driven method to constrain the antiproton background in the Mu2e experiment

The Mu2e experiment will search for CLFV neutrinoless coherent muon to electron conversion in the field of an Al nucleus. The expected signal is a 104.97 MeV/c monochromatic $e^-$ (CE). CE-like $e^-$’s could also come from $\bar{p}$’s annihilating in the Stopping Target (ST). The background induced by $\bar{p}$’s is expected to be low but has a large systematic uncertainty. It cannot be suppressed by the time window cut used to reduce the prompt background. However, $p\bar{p}$ annihilation in the ST is the only source of events in the Mu2e detector with multiple tracks coming from the ST, simultaneous in time, each with a momentum in the signal window region. We exploited this unique feature and developed algorithms to identify and reconstruct multi-track events. This paper discusses the status and prospects of this data-driven method to constrain the $\bar{p}$ background at Mu2e.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing hole trap production due to proton irradiation in germanium cross-strip detectors

We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, [nσ] h , follows a linear relationship with the proton fluence, F p , with a slope of (5.4 ± 0.4) x 10 -11 cm/p + . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

Three-dimensional reconstruction of implosion stagnation in laser direct drive on OMEGA

Multidimensional effects on hot-spot formation must be considered to better understand the current limits on the performance of direct-drive inertial confinement fusion experiments on OMEGA with cryogenically layered solid deuterium–tritium targets. A comprehensive reconstruction effort has been established at the Laboratory for Laser Energetics to infer hot-spot and shell conditions at stagnation from a large collection of x-ray, neutron, and particle detectors along multiple lines of sight. Several time-gated and time-integrated x-ray imagers are being used to record the shape of the hot-spot plasma. A 3D hot-spot x-ray emission tomography technique has been developed to infer low-mode drive asymmetries from the hot-spot shape. A suite of neutron diagnostics is used to provide measurements of hot-spot flow velocity, ion temperature, and areal density. Here, the information obtained from the x-ray and neutron detectors will be combined into a coherent model of the shape of the hot spot and shell assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗