Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

The Space Shuttle Columbia Accident Investigation and Reconstruction: Two Years Later

The Space Shuttle Columbia was lost during re-entry over two years ago. Since the release of the official materials-related findings in August of 2003, additional testing and analysis of select pieces of debris has continued. Microanalytical techniques, including EMPA, ESCA, and x-ray elemental dot mapping, were employed during the initial investigation; the results related the microstructural characteristics of deposit layers to the breach location in the leading edge of the left wing. Such characteristics included deposition order, composition, and distribution. Subsequent to the original efforts, new analytical data and information, not available at the time of the primary investigation, has been generated. This data was obtained via a low-vacuum SEM, fitted not only with a light-element EDS detector, but an XRF tube as well. Essentially, for elements up to sodium, classic EDS was utilized; above sodium, XRF was used. Predominantly, the elements of interest were aluminum, titanium, chromium, iron, nickel, and copper. The findings of both old and new data are compared, and their application to the overall accident investigation detailed.

McDanels, Steven J.↗

The Earth Occultation Technique with the Burst and Transient Source Experiment

The Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) is successfully being used as an all-sky hard X-ray monitor. The experiment consists of a set of eight uncollimated detectors sensitive to photons in the 20 keV to 2 MeV range. Since CGRO orbits the Earth at an altitude of about 450 km, about 33% of the sky, as viewed with BATSE, is covered by the Earth at any given time. The entire sky is subject to Earth occultation for some portion of CGRO's 52 day precession period. When a source sets below or rises above the Earth's limb, atmospheric attenuation produces step-like features in the BATSE data. The observed change in count rate in several energy bands provides a measurement of the source intensity and spectrum without sophisticated background models. These occultation features are used to locate and monitor astrophysical sources with BATSE when the source signal can be separated from the detector background. Examples of step searches, spectra, light curves, and transform imaging are presented.

Wilson, C. A.↗

Reconstructing the Sky Location of Gravitational-Wave Detected Compact Binary Systems: Methodology for Testing and Comparison

The problem of reconstructing the sky position of compact binary coalescences detected via gravitational waves is a central one for future observations with the ground-based network of gravitational-wave laser interferometers, such as Advanced LIGO and Advanced Virgo. Different techniques for sky localization have been independently developed. They can be divided in two broad categories: fully coherent Bayesian techniques, which are high latency and aimed at in-depth studies of all the parameters of a source, including sky position, and "triangulation-based" techniques, which exploit the data products from the search stage of the analysis to provide an almost real-time approximation of the posterior probability density function of the sky location of a detection candidate. These techniques have previously been applied to data collected during the last science runs of gravitational-wave detectors operating in the so-called initial configuration. Here, we develop and analyze methods for assessing the self consistency of parameter estimation methods and carrying out fair comparisons between different algorithms, addressing issues of efficiency and optimality. These methods are general, and can be applied to parameter estimation problems other than sky localization. We apply these methods to two existing sky localization techniques representing the two above-mentioned categories, using a set of simulated inspiralonly signals from compact binary systems with a total mass of equal to or less than 20M solar mass and nonspinning components. We compare the relative advantages and costs of the two techniques and show that sky location uncertainties are on average a factor approx. equals 20 smaller for fully coherent techniques than for the specific variant of the triangulation-based technique used during the last science runs, at the expense of a factor approx. equals 1000 longer processing time.

technique used↗

Volumetric leak detector

Portable volumetric leak detector measures leakage in the range of 5 to 40 cc/hr. The detector, a fluid displacing apparatus, measures the leakage of gases across valve seats and checks components and systems of components independent of size in relatively short periods of time.

Elser, M. J.↗

OSO-8 observations of Hercules X-1

The X-ray binary Her X-1 was observed by the GSFC cosmic X-ray detectors aboard OSO-8 between August 26 and September 3, 1975. The results reported are based on quick look tapes which contain less than 10% of the total time spent on source. Spectra were observed during different phases of the binary period including the anomalous low state (dip) in X-ray intensity. The normal high spectra is well represented by a power law with a short cutoff above approximately 25 keV. A significant and varying enhancement in the intensity around 6.7 keV was observed, suggesting the presence of an iron line. Absorption was seen in the spectrum immediately following eclipse. The dip spectrum is found to be considerably flattened. Also spectra are presented for different phases of the pulse period.

Pravdo, S. H.↗

Anisotropies in the fluxes of Pioneer 10 protons

One-hour-averaged fluxes of 1.8- to 2.15-MeV protons observed by the LET2 detector on Pioneer 10 on the inbound trajectory showed anisotropies attributable to corotation of Jupiter's magnetodisc only when Pioneer was near the dipole equator. Most of the time the anisotropy greatly exceeded the value expected from corotation. Gradients in the distribution function can be used to account for this excess anisotropy, but the amount of gradient required is unacceptably large by 1-2 orders of magnitude. If they were taken as real, these gradients would predict almost complete disappearance of these protons from Jupiter's magnetosphere in a matter of hours. The remedy is to introduce into the model of the distribution function proton flow along field lines away from the equator into both the southern and the northern hemisphere. The parallel flux at the southernmost latitudes reached by Pioneer can reach 25% of the product of proton density and velocity, i.e., 25% of the maximum possible.

Northrop, T. G.↗

Investigation of effects of temperature, salinity, and electrode design on the performance of an electrochemical coliform detector

The results of two research programs to determine the optimum detector design for measuring fecal coliforms in saline waters for operational systems are presented. One program was concerned with the effects of temperature and salinity on endpoint response time, and the other, the interaction between electrode configurations and the test organisms. Test results show that the endpoint response time is related to salinity and seawater temperature; however, these results can be minimized by the correct choice of growth media. Electrode configurations were developed from stainless steel, Parlodion-coated stainless steel, and platinum that circumvented problems associated with the commercial redox electrodes.

Grana, D. C.↗

Self-calibrating threshold detector

A self calibrating threshold detector comprises a single demodulating channel which includes a mixer having one input receiving the incoming signal and another input receiving a local replica code. During a short time interval, an incorrect local code is applied to the mixer to incorrectly demodulate the incoming signal and to provide a reference level that calibrates the noise propagating through the channel. A sample and hold circuit is coupled to the channel for storing a sample of the reference level. During a relatively long time interval, the correct replica code provides an output level which ranges between the reference level and a maximum level that represents incoming signal presence and synchronism with the replica code. A summer substracts the stored sample reference from the output level to provide a resultant difference signal indicative of the acquisition of the expected signal.

Barnes, J. R.↗

Heavy Cosmic Ray Measurement Aboard Spacelab-1

A stack of CR-39 plastic track detectors was exposed to cosmic radiation during the 10 days mission aboard Spacelab-1. A part of the stack was rotated one revolution within 7 days. The impact time of most of the particles was correlated with the orbit position of the shuttle and thus with geomagnetic field parameters. The analysis of heavy particles with charge Z greater than or equal to 6 in the energy range 50-150 MeV per nucleon with special emphasis on geomagnetically forbidden particles is reported.

Beaujean, R.↗

The velocity structure and turbulence at the center of the Orion Nebula

Using the Coude Feed System of the Kitt Peak National Observatory at its highest possible dispersion and a CCD detector with wide dynamic range it was possible to examine in detail the radial and turbulent velocities of the Orion Nebula at the seeing limit. For the first time, multiple components of the spectral lines were resolved and the Gaussian profiles fit to them. Using four different observing runs, two circular areas 2 minutes in diameter were observed, the first centered on the theta sup 1 Orionis and the second centered on theta sup 2 Orionis. The velocity resolution of 1 km/s combined with the angular resolution of 2 seconds allowed observation in detail at line splitting as well as the location and measurement of high internal motions, about -50 km/s with respect to the bulk of ionized matter. Because over 900 different positions were measured, modern statistical techniques were used for the analysis of turbulence, so that the dispersion relation and the structure function could be calculated and compared with predictions of the Kolmogorov theory. The random motions showed correlation with spatial separation, as expected for turbulence; but comparison with predictions of the classical theory for nebular turbulence showed poor agreement. If Kolmogorov theory applies, then the energy must be input at many scales.

Castaneda, Hector O.↗

Non-intrusive Space Shuttle Main Engine nozzle exit diagnostics

The results of a conceptual design study on the feasibility of nonintrusive optical diagnostics have shown that UV laser-excited Raman scattering can furnish reliable and accurate temperature and multiple-species data for the Space Shuttle Main Engine's exhaust flow. Enhanced OH flow tagging by UV photodissociation of H2O was used in velocity measurements; a time-delayed pulsed dye laser beam at 308 nm excites fluorescence from OH, and the location of the convected enhanced OH zone is measured with an optical multichannel detector.

Shirley, John A.↗

A programmable CCD driver circuit for multiphase CCD operation

A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.

Ewin, Audrey J.↗

Rocket plume spectrometry: A system permitting engine condition monitoring, as applied to the technology test bed engine

The appearance of visible objects in the exhaust plume of space shuttle main engines (SSME) during test firings is discussed. A program was undertaken to attempt to identify anomalous material resulting from wear, normal or excessive, of internal parts, allowing time monitoring of engine condition or detection of failure precursors. Measurements were taken during test firings at Stennis Space Center and at the Santa Suzanna facility in California. The results indicated that a system having high spectral resolution, a fast time response, and a wide spectral range was required to meet all requirements, thus two special systems have been designed and built. One is the Optical Plume Anomaly Detector (OPAD). The other instrument, which is described in this report, is the superspectrometer, an optical multichannel analyzer having 8,192 channels covering the spectral band 250 to 1,000 nm.

Powers, W. T.↗

The rate of neutron star binary mergers in the universe - Minimal predictions for gravity wave detectors

Of the many sources which gravitational wave observatories might see, merging neutron star binaries are the most predictable. Their waveforms at the observable frequencies are easy to calculate. And three systems which will merge in less than a Hubble time have already been observed as binary pulsars: two in the disk of the Galaxy, and one in a globular cluster. From the lifetimes and positions of these, a lower limit to the merger rate in the Galaxy and globular cluster system are inferred with confidence. Taking the merger rate in other galaxies to scale with the star formation rate, the merger rate expected in the local universe is computed. An ultraconservative lower limit to the rate gives three per year within 1 Gpc. The best estimate, still conservative in that it considers only systems like those already observed, gives three per year within 200 Mpc. An upper limit of three mergers per year within 23/h Mpc is set by the rate of Type Ib supernovae. The rates of black hole binary mergers and black hole-neutron star binary mergers are model-dependent, but could be comparable to the given rate of neutron-star binary mergers.

Phinney, E. S.↗

Report of the x ray and gamma ray sensors panel

Overall five major areas of technology are recommended for development in order to meet the science requirements of the Astrotech 21 mission set. These are: detectors for high resolution gamma ray spectroscopy, cryogenic detectors for improved x ray spectral and spatial resolution, advanced x ray charge coupled devices (CCDs) for higher energy resolution and larger format, extension to higher energies, liquid and solid position sensitive detectors for improving stopping power in the energy range 5 to 500 keV and 0.2 to 2 MeV. Development plans designed to achieve the desired capabilities on the time scales required by the technology freeze dates have been recommended in each of these areas.

Szymkowiak, Andrew↗

Laboratory scaled simulation of lidar cloud sounding experiments

The results of lidar measurements carried out on laboratory scale models of clouds are presented. Measurements on laboratory scale models are important since one has the knowledge of the relevant parameters of the diffusing medium, such as: scattering and absorption coefficients, phase function, homogeneity, shape, etc. Knowledge of these parameters enables one to use the results to test the reliability of theoretical and numerical investigations. To obtain a laboratory scaled model of a lidar system sounding a cloud, it is necessary to scale down all the geometrical quantities by the same factor to reduce distances of the order of kilometers to the order of meters, keeping the size and the optical depth of the diffusers unchanged. If a time resolution of the order of nanoseconds is necessary for a lidar sounding actual clouds, the corresponding time resolution for the laboratory model should be of the order of picoseconds. It is possible to obtain this resolution by using picosecond laser systems and fast electrooptical detectors like the streak camera. The results of the laboratory measurements showed that the multiple scattering effect strongly depends on the size of the diffusers, as well as on the concentration. The experimental results were compared with the numerical results of a Monte Carlo code. A generally good agreement was obtained.

Zaccanti, G.↗

Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

White, Richard M.↗

Modeling Studies of the MODIS Solar Diffuser Attenuation Screen and Comparison with On-Orbit Measurements

The MODIS instrument relies on solar calibration to achieve the required radiometric accuracy. This solar calibration occurs as the TERRA spacecraft comes up over the North Pole. The earth underneath the spacecraft is still dark for approximately one minute and the sun is just rising over the earth's north polar regions. During this time the sun moves through about 4 degrees, the scan mirror rotates about 19 times and about 50 frames (exposures) are made of the white solar diffuser. For some of MODIS'S bands the brightness of the screen is reduced, to prevent detector saturation, by means of a pinhole screen, which produces approximately 600 pinhole images of the sun within the field of view of any one detector. Previous attempts at creating a detailed radiometric model of this calibration scenario produced intensity variations on the focal planes with insufficient detail to be useful. The current computational approach produces results, which take into account the motion of the sun and the scan mirror and produces variations, which strongly resemble the observed focal plane intensity variations. The computational approach and results and a comparison with actual observational data are presented.

Waluschka, Eugene↗