Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

PowerGridworld: A Framework for Multi-Agent Reinforcement Learning in Power Systems: Preprint

We present the PowerGridworld software package to provide users with a light-weight, modular, and customizable framework for creating power systems-focused, multi-agent gym environments that readily integrate with existing training frameworks for reinforcement learning (RL). While many frameworks exist for training multi-agent (MA) RL policies, none exist to rapidly prototype and develop the environments themselves, especially in the context of heterogeneous (composite, multi-device) power systems where power flow solutions are required to define grid-level variables and costs. PowerGridworld is an open-source software package that helps to fill this gap. To highlight PowerGridworld's key features, we present two case studies and demonstrate learning multi-agent RL policies using both OpenAI's MADDPG and RLLib's PPO algorithms where, in both cases, at least some subset of agents incorporate elements of the power flow solution at each time step as part of their reward (negative cost) structures.

MATHEMATICS AND COMPUTING↗

TU-G-BRD-01: Quantifying the Effectiveness of the Physics Pre-Treatment Plan Review for Detecting Errors in Radiation Therapy

Purpose: Physics pre-treatment plan review is crucial to safe radiation oncology treatments. Studies show that most errors originate in treatment planning, which underscores the importance of physics plan review. As a QA measure the physics review is of fundamental importance and is central to the profession of medical physics. However, little is known about its effectiveness. More hard data are needed. The purpose of this study was to quantify the effectiveness of physics review with the goal of improving it. Methods: This study analyzed 315 “potentially serious” near-miss incidents within an institutional incident learning system collected over a two-year period. 139 of these originated prior to physics review and were found at the review or after. Incidents were classified as events that: 1)were detected by physics review, 2)could have been detected (but were not), and 3)could not have been detected. Category 1 and 2 events were classified by which specific check (within physics review) detected or could have detected the event. Results: Of the 139 analyzed events, 73/139 (53%) were detected or could have been detected by the physics review; although, 42/73 (58%) were not actually detected. 45/73 (62%) errors originated in treatment planning, making physics review the first step in the workflow that could detect the error. Two specific physics checks were particularly effective (combined effectiveness of >20%): verifying DRRs (8/73) and verifying isocenter (7/73). Software-based plan checking systems were evaluated and found to have potential effectiveness of 40%. Given current data structures, software implementations of some tests such as isocenter verification check would be challenging. Conclusion: Physics plan review is a key safety measure and can detect majority of reported events. However, a majority of events that potentially could have been detected were NOT detected in this study, indicating the need to improve the performance of physics review.

60 APPLIED LIFE SCIENCES↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U control system (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-48: Imaging Origin-Radiation Isocenter Coincidence for Linac-Based SRS with Novalis Tx

Purpose To implement and evaluate an image-based Winston-Lutz (WL) test to measure the displacement between ExacTrac imaging origin and radiation isocenter on a Novalis Tx system using RIT V6.2 software analysis tools. Displacement between imaging and radiation isocenters was tracked over time. The method was applied for cone-based and MLC-based WL tests. Methods The Brainlab Winston-Lutz phantom was aligned to room lasers. The ExacTrac imaging system was then used to detect the Winston- Lutz phantom and obtain the displacement between the center of the phantom and the imaging origin. EPID images of the phantom were obtained at various gantry and couch angles and analyzed with RIT calculating the phantom center to radiation isocenter displacement. The RIT and Exactrac displacements were combined to calculate the displacement between imaging origin and radiation isocenter. Results were tracked over time. Results Mean displacements between ExacTrac origin and radiation isocenter were: VRT: −0.1mm ± 0.3mm, LNG: 0.5mm ± 0.2mm, LAT: 0.2mm ± 0.2mm (vector magnitude of 0.7 ± 0.2mm). Radiation isocenter was characterized by the mean of the standard deviations of the WL phantom displacements: σVRT: 0.2mm, σLNG: 0.4mm, σLAT: 0.6mm. The linac couch base was serviced to reduce couch walkout. This reduced σLAT to 0.2mm. These measurements established a new baseline of radiation isocenter-imaging origin coincidence. Conclusion The image-based WL test has ensured submillimeter localization accuracy using the ExacTrac imaging system. Standard deviations of ExacTrac-radiation isocenter displacements indicate that average agreement within 0.3mm is possible in each axis. This WL test is a departure from the tradiational WL in that imaging origin/radiation isocenter agreement is the end goal not lasers/radiation isocenter.

60 APPLIED LIFE SCIENCES↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

The upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U Control System (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

Boyer, M↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Failure Mechanism Traceability and Application in Human System Interface of Nuclear Power Plants using RESHA

In recent years, there has been considerable effort to modernize existing and new nuclear power plants with digital instrumentation and control systems (DI&C). However, there has also been considerable concern both by industry and regulatory bodies for the risk and consequence analysis of these systems. Of particular concern are digital common cause failures (CCFs) specifically related to software defects. These “misbehaviors” by the software can occur in both the control and monitoring of a system. While many new methods have been proposed to identify potential software failure modes, such as Systems-theoretic Process Analysis (STPA), Hazard and Consequence Analysis for Digital Systems (HAZCADS), etc., these methods are focused primarily on the control action pathway of a system. In contrast, the information feedback pathway lacks unsafe control actions (UCAs), which are typically related to software basic events; thus, assessment of software basic events in such systems is unclear. In this work, we present the idea of intermediate processors and unsafe information flow (UIF) to help safety analysts trace failure mechanisms in the feedback pathway and how they can be integrated into a fault tree for improved assessment capability. The concepts presented are demonstrated in two comprehensive case studies, a smart sensor integrated platform for unmanned autonomous vehicles and another on a representative advanced human system interface (HSI) for safety critical plant monitoring. The qualitative software basic events are identified, and a fault tree analysis is conducted based on a modified Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) methodology. The case studies demonstrate the use of UIF and intermediate processors in the fault tree to improve traceability of software failures in highly complex digital instrumentation feedback. The improved method can also clarify fault tree construction when multiple component dependencies are present in the system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Failure Mechanism Traceability and Application in Human System Interface of Nuclear Power Plants using RESHA

In recent years, there has been considerable effort to modernize existing and new nuclear power plants with digital instrumentation and control systems (DI&C). However, there has also been considerable concern both by industry and regulatory bodies for the risk and consequence analysis of these systems. Of particular concern are digital common cause failures (CCFs) specifically related to software defects. These “misbehaviors” by the software can occur in both the control and monitoring of a system. While many new methods have been proposed to identify potential software failure modes, such as Systems-theoretic Process Analysis (STPA), Hazard and Consequence Analysis for Digital Systems (HAZCADS), etc., these methods are focused primarily on the control action pathway of a system. In contrast, the information feedback pathway lacks unsafe control actions (UCAs), which are typically related to software basic events; thus, assessment of software basic events in such systems is unclear. In this work, we present the idea of intermediate processors and unsafe information flow (UIF) to help safety analysts trace failure mechanisms in the feedback pathway and how they can be integrated into a fault tree for improved assessment capability. The concepts presented are demonstrated in two comprehensive case studies, a smart sensor integrated platform for unmanned autonomous vehicles and another on a representative advanced human system interface (HSI) for safety critical plant monitoring. The qualitative software basic events are identified, and a fault tree analysis is conducted based on a modified Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) methodology. The case studies demonstrate the use of UIF and intermediate processors in the fault tree to improve traceability of software failures in highly complex digital instrumentation feedback. The improved method can also clarify fault tree construction when multiple component dependencies are present in the system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization and Portability of a Fusion OpenACC-based FORTRAN HPC Code from NVIDIA to AMD GPUs

NVIDIA has been the main provider of GPU hardware in HPC systems for over a decade. Most applications that benefit from GPUs have thus been developed and optimized for the NVIDIA software stack. Recent exascale HPC systems are, however, introducing GPUs from other vendors, e.g. with the AMD GPU-based OLCF Frontier system just becoming available. AMD GPUs cannot be directly accessed using the NVIDIA software stack, and require a porting effort by the application developers. This paper provides an overview of our experience porting and optimizing the CGYRO code, a widely-used fusion simulation tool based on FORTRAN with OpenACC-based GPU acceleration. While the porting from the NVIDIA compilers was relatively straightforward using the CRAY compilers on the AMD systems, the performance optimization required more fine-tuning. In the optimization effort, we uncovered code sections that had performed well on NVIDIA GPUs, but were unexpectedly slow on AMD GPUs. After AMD-targeted code optimizations, performance on AMD GPUs has increased to meet our expectations. Modest speed improvements were also seen on NVIDIA GPUs, which was an unexpected benefit of this exercise.

Sfiligoi, Igor↗

RAG for FLAG: AI Assistance for a Physics Code

Artificial intelligence (AI) has quickly become an important tool in scientific research, where significant efforts are underway to develop tools that will expedite the research process. One area of particular impact is scientific software, which can be particularly complex, and therefore time consuming to learn and use effectively. AI assistants are increasingly helping to streamline the process by performing tasks such as interactively answering user questions or suggesting solutions. Los Alamos National Laboratory (LANL) develops several advanced scientific codes, such as FLAG, which can be used to run multiphysics simulations. With this study, our goal was to develop an AI assistant for FLAG that could help make the process of understanding the software and running physics simulations more efficient. To develop an AI assistant for FLAG, we used a method called retrieval-augmented generation (RAG), which is a technique that uses information from relevant data sources to enhance the accuracy of large language models (LLMs). We used the FLAG user manual and other FLAG documentation as the knowledge base for the RAG system. When a user provides a query, RAG retrieves relevant sections from the knowledge base in response, then uses those excerpts to generate grounded and contextually rich answers. We found that our AI assistant was able to provide context aware answers and source references to user queries. To evaluate performance, we developed a set of 40 benchmark questions and compared the accuracy of the responses to those of two standard LLMs without retrieval. Our AI assistant significantly outperformed the standard LLMs at answering FLAG-related questions, with an 82.5% accuracy rate, compared to 47.5% for both of the standard LLMs. This has the potential to make the process of learning and using FLAG much easier, especially for new users. Ultimately, it supports LANL’s broader mission by empowering scientists and engineers to focus more on discovery and analysis rather than on navigating complex software systems.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-103: Setup Errors Analysis by Cone-Beam CT (CBCT)-Based Imaged-Guided Intensity Modulated Radiotherapy for Esophageal Cancer

Purpose: To quantify setup errors by pretreatment kilovolt cone-beam computed tomography(KV-CBCT) scans for middle or distal esophageal carcinoma patients. Methods: Fifty-two consecutive middle or distal esophageal carcinoma patients who underwent IMRT were included this study. A planning CT scan using a big-bore CT simulator was performed in the treatment position and was used as the reference scan for image registration with CBCT. CBCT scans(On-Board Imaging v1. 5 system, Varian Medical Systems) were acquired daily during the first treatment week. A total of 260 CBCT scans was assessed with a registration clip box defined around the PTV-thorax in the reference scan based on(nine CBCTs per patient) bony anatomy using Offline Review software v10.0(Varian Medical Systems). The anterior-posterior(AP), left-right(LR), superiorinferior( SI) corrections were recorded. The systematic and random errors were calculated. The CTV-to-PTV margins in each CBCT frequency was based on the Van Herk formula (2.5Σ+0.7σ). Results: The SD of systematic error (Σ) was 2.0mm, 2.3mm, 3.8mm in the AP, LR and SI directions, respectively. The average random error (σ) was 1.6mm, 2.4mm, 4.1mm in the AP, LR and SI directions, respectively. The CTV-to-PTV safety margin was 6.1mm, 7.5mm, 12.3mm in the AP, LR and SI directions based on van Herk formula. Conclusion: Our data recommend the use of 6 mm, 8mm, and 12 mm for esophageal carcinoma patient setup in AP, LR, SI directions, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The IQ-wall and IQ-station -- harnessing our collective intelligence to realize the potential of ultra-resolution and immersive visualization

We present a pair of open-recipe, affordably-priced, easy-to-integrate, and easy-to-use visualization systems. The IQ-wall is an ultra-resolution tiled display wall that scales up to 24 screens with a single PC. The IQ-station is a semi-immersive display system that utilizes commodity stereoscopic displays, lower cost tracking systems, and touch overlays. These systems have been designed to support a wide range of research, education, creative activities, and information presentations. They were designed to work equally well as stand-alone installations or as part of a larger distributed visualization ecosystem. We detail the hardware and software components of these systems, describe our deployments and experiences in a variety of research lab and university environments, and share our insights for effective support and community development.

97 MATHEMATICS AND COMPUTING↗

Report of the Final Configuration of the Johnson Noise Thermometry System

This document is a report on the final box and software configuration of the Johnson Noise Thermometry System being developed at ORNL. Much of this has been reported previously so that this report will be a systems-level summary of those reports, In addition we will describe some of the issues encountered during development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Models and Fast Simulation Algorithms for MARS Plants

With the successful commercialization of modular multilevel converters (MMC) and rapid increase in photovoltaic (PV) penetration and energy storage systems (ESS), one of the research areas being explored dynamically is integration of PV systems and ESS systems to MMCs. On this front, an integrated development of PV plants, ESS, and alternating- and direct-current (ac/dc) systems through Multi-Port Autonomous Reconfigurable Solar (MARS) plant is proposed and being researched upon. However, simulation of MARS systems on traditional existing software takes very long time (order of days) due to the presence of a large number of states and non-linear devices. Therefore, development of fast high fidelity models is of paramount importance to test the hardware design, control design and planning of power system expansions. In this context, two research objectives are addressed in this paper: firstly, an ultra fast single- or multi- CPU simulation algorithm to simulate the MARS system based on state-space models, hybrid discretization algorithm with a relaxation technique that reduces the imposed computational burden and a multi-rate method is presented. Secondly, a reduced order model of MARS is also presented. Both the developed techniques are validated with respect to reference PSCAD/EMTDC model.

Marthi, Phani Ratna Vanamali↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device

Purpose: To investigate the properties of a modified backscatter shielded electronic portal imaging device (BSS-EPID) and to develop a dose model to convert BSS-EPID images to dose in water as part of an improved system for dosimetry using EPIDs. Methods: The effectiveness of the shielding of the BSS-EPID was studied by comparing images measured with the BSS-EPID mounted on the support arm to images measured with the BSS-EPID removed from the support arm. A dose model was developed and optimized to reconstruct dose in water at different depths from measured BSS-EPID images. The accuracy of the dose model was studied using BSS-EPID images of 28 IMRT fields to reconstruct dose in water at depths of 2, 5, 10, and 20 cm and comparing to measured dose in water from a two-dimensional diode array at the same depths. The ability of the BSS-EPID system to operate independently of detector position was demonstrated by comparing the dose reconstruction of a 10 x 10 cm{sup 2} field using different detector offsets to that measured by a two-dimensional diode array. Results: The shielding of the BSS-EPID was found to be effective, with more than 99% of pixels showing less than 0.5% change due to the presence of the support arm and at most a 0.2% effect on the central axis for 2 x 2 cm{sup 2} fields to fully open 30 x 40 cm{sup 2} images. The dose model was shown to accurately reconstruct measurements of dose in water using BSS-EPID images with average {gamma} pass rates (2%, 2 mm criteria) of 92.5%, 98.7%, 97.4%, and 97.2% at depths of 2, 5, 10, and 20 cm, respectively, when compared to two-dimensional diode array measurements. When using 3%, 3 mm {gamma} criteria, the average pass rate was greater than 97% at all depths. Reconstructed dose in water for a 10 x 10 cm{sup 2} field measured with detector offsets as large as 10 cm agreed with each other and two-dimensional diode array measurements within 0.9%. Conclusions: The modified BSS-EPID and associated dose model provide an improved system for dosimetry measurements using EPIDs. Several important limitations of the current hardware and software are addressed by this system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Programmable Digital Devices used in Advanced Reactors

This paper introduces the concepts of common cause failure, diversity, and defense-in-depth used by the nuclear industry to analyze resilience in reactors. A survey of publicly traded and private companies building advanced reactors and their licensing status is presented. Safety and non-safety systems found in the NuScale Power design are summarized and the likely hardware and software categories used by those systems are enumerated. The importance of industry partners is highlighted. This paper also identifies an alternate path forward without industry partners to advance the knowledge needed to use artificial intelligence to analyze HBOMs and SBOMs to better understand reactor resiliency.

cybersecurity↗

Autonomous Inspection of Geologic Repositories: Current State of the Art and Future Directions

Geological repositories for nuclear waste, including spent nuclear fuel, present a significant challenge for traditional International Atomic Energy Agency (IAEA) safeguards tools due to their inaccessibility and demanding operational conditions. The IAEA has been working closely with Member State organizations currently involved in repository construction and planning, including Euratom, the Finnish and Swedish regulatory authorities, and relevant facility operators. However, the verification challenge remains unsolved, and there persists an out- standing need for tools and approaches that will help the IAEA verify that no nuclear material is diverted from a repository environment. The challenge is also not static. Activities must encompass verification of the design, prior to and during the construction/operation phase, and post backfill. Throughout these various phases, it is imperative that the IAEA maintains a continuity of knowledge (CoK) of all material including information on material inventory and flow. This paper highlights these challenges and outlines how they might be addressed by using remote or autonomous vehicles. Specifically, we discuss the current state of the art in robotic autonomy for known or partially known environment mapping and patrolling, as well as shared autonomy, where humans collaborate with closed loop autonomation to complete tasks. We explore the feasibility of using rovers for these verification tasks, along with the challenges associated with system implementation. Hardware and software suggestions are provided based on the adoption of similar technologies in other comparable areas and ability to close technical gaps. Lastly, human-robotic interactions are considered based on the challenges of the environment of the repository and effective deployment and continued operation of the robot system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗