Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Metal hydride differential scanning calorimetry as an approach to compositional determination of mixtures of hydrogen isotopologues and helium

Gaseous mixtures of diatomic hydrogen isotopologues and helium are often encountered in the nuclear energy industry and in analytical chemistry. Compositions of stored mixtures can vary due to interactions with storage and handling materials. When tritium is present, it decays to form ions and helium-3, both of which can lead to further compositional variation. Monitoring of composition is typically achieved by mass spectrometry, a method that is bulky and energy-intensive. Mass spectrometers disperse sample material through vacuum pumps, which is especially troublesome if tritium is present. Moreover, our ultimate goal is to create a compact, fast, low-power sensor that can determine composition with minimal gas consumption and waste generation, as a complement to mass spectrometry that can be instantiated more widely. We propose calorimetry of metal hydrides as an approach to this, due to the strong isotope effect on gas absorption, and demonstrate the sensitivity of measured heat flow to atomic composition of the gas. Peak shifts are discernible when mole fractions change by at least 1%. A mass flow restriction results in a unique dependence of the measurement on helium concentration. We present a mathematical model as a first step toward prediction of the peak shapes and positions. The model includes a useful method to compute estimates of phase diagrams for palladium in the presence of arbitrary mixtures of hydrogen isotopologues. As a result, we expect that this approach can be used to deduce unknown atomic compositions from measured calorimetric data over a useful range of partial pressures of each component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses

A major update to the mass spectrometry imaging (MSI) software MSiReader is presented, offering a multitude of newly added features critical to MSI analyses. MSiReader is a free, open-source, and vendor-neutral software written in the MATLAB platform and is capable of analyzing most common MSI data formats. A standalone version of the software, which does not require a MATLAB license, is also distributed. The newly incorporated data analysis features expand the utility of MSiReader beyond simple visualization of molecular distributions. The MSiQuantification tool allows researchers to calculate absolute concentrations from quantification MSI experiments exclusively through MSiReader software, significantly reducing data analysis time. An image overlay feature allows the incorporation of complementary imaging modalities to be displayed with the MSI data. A polarity filter has also been incorporated into the data loading step, allowing the facile analysis of polarity switching experiments without the need for data parsing prior to loading the data file into MSiReader. A quality assurance feature to generate a mass measurement accuracy (MMA) heatmap for an analyte of interest has also been added to allow for the investigation of MMA across the imaging experiment. Most importantly, as new features have been added performance has not degraded, in fact it has been dramatically improved. These new tools and the improvements to the performance in MSiReader v1.0 enable the MSI community to evaluate their data in greater depth and in less time. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

Mass spectrometry imaging (MSI) has primarily been applied in localizing biomolecules within biological matrices. Although well-suited, the application of MSI for comparing thousands of spatially defined spotted samples has been limited. One reason for this is a lack of suitable and accessible data processing tools for the analysis of large arrayed MSI sample sets. In this paper, the OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http://openmsi.nersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was evaluated by analyzing an MSI data set of a high-throughput glycoside hydrolase activity screen comprising 384 samples arrayed onto a NIMS surface at a 450 μm spacing, decreasing analysis time >100-fold while maintaining robust spot-finding. The utility of OMAAT was demonstrated for screening metabolic activities of different sized soil particles, including hydrolysis of sugars, revealing a pattern of size dependent activities. Finally, these results introduce OMAAT as an effective toolkit for analyzing spatially defined samples in MSI. OMAAT runs on all major operating systems, and the source code can be obtained from the following GitHub repository: https://github.com/biorack/omaat.

47 OTHER INSTRUMENTATION↗

Exhaustive Product Analysis of Three Benzene Discharges by Microwave Spectroscopy

Using chirped and cavity microwave spectroscopies, automated double resonance, new high-speed fitting and deep learning algorithms, and large databases of computed structures, the discharge products of benzene alone, or in combination with molecular oxygen or nitrogen, have been exhaustively characterized between 6.5 and 26 GHz. In total, more than 3300 spectral features were observed; 89% of these, accounting for 97% of the total intensity, have now been assigned to 152 distinct chemical species and 60 of their variants (i.e., isotopic species and vibrationally excited states). Roughly 50 of the products are entirely new or poorly characterized at high resolution, including many heavier by mass than the precursor benzene. These findings provide direct evidence for a rich architecture of two- and three-dimensional carbon and indicate that benzene growth, particularly the formation of ring–chain molecules, occurs facilely under our experimental conditions. The present analysis also illustrates the utility of microwave spectroscopy as a precision tool for complex mixture analysis, irrespective of whether the rotational spectrum of a product species is known a priori or not. From this large quantity of data, for example, it is possible to determine with confidence the relative abundances of different product masses, but more importantly the relative abundances of different isomers with the same mass. We review the complementary nature of this type of analysis to traditional mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical and electronic properties of sub-surface conducting layers in diamond created by MeV B-implantation at elevated temperatures

Boron implantation with in-situ dynamic annealing is used to produce highly conductive sub-surface layers in type IIa (100) diamond plates for the search of a superconducting phase transition. Here, we demonstrate that high-fluence MeV ion-implantation, at elevated temperatures avoids graphitization and can be used to achieve doping densities of 6 at. %. In order to quantify the diamond crystal damage associated with implantation Raman spectroscopy was performed, demonstrating high temperature annealing recovers the lattice. Additionally, low-temperature electronic transport measurements show evidence of charge carrier densities close to the metal-insulator-transition. After electronic characterization, secondary ion mass spectrometry was performed to map out the ion profile of the implanted plates. The analysis shows close agreement with the simulated ion-profile assuming scaling factors that take into account an average change in diamond density due to device fabrication. Finally, the data show that boron diffusion is negligible during the high temperature annealing process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid Analysis of Inorganic Species in Herbaceous Materials Using Laser-Induced Breakdown Spectroscopy [plus supplemental information]

Inorganic compounds in biomass, often referred to as ash, are known to be problematic in the thermochemical conversion of biomass to bio-oil or syngas and, ultimately, hydrocarbon fuels because they negatively influence reaction pathways, contribute to fouling and corrosion, poison catalysts, and impact waste streams. The most common ash-analysis methods, such as inductively coupled plasma-optical emission spectrometry/mass spectrometry (ICP-OES/MS), require considerable time and expensive reagents. Laser-induced breakdown spectroscopy (LIBS) is emerging as a technique for rapid analysis of the inorganic constituents in a wide range of biomass materials. This study compares analytical results using LIBS data to results obtained from three separate ICP-OES/MS methods for 12 samples, including six standard reference materials. Analyzed elements include aluminum, calcium, iron, magnesium, manganese, phosphorus, potassium, sodium, and silicon, and results show that concentrations can be measured with an uncertainty of approximately 100 parts per million using univariate calibration models and relatively few calibration samples. These results indicate that the accuracy of LIBS is comparable to that of ICP-OES methods and indicate that some acid-digestion methods for ICP-OES may not be reliable for Na and Al. These results also demonstrate that germanium can be used as an internal standard to improve the reliability and accuracy of measuring many elements of interest, and that LIBS can be used for rapid determination of total ash in biomass samples. Key benefits of LIBS include little sample preparation, no reagent consumption, and the generation of meaningful analytical data instantaneously.

09 BIOMASS FUELS↗

Methods of chemical and phase composition analysis of gallstones

This review presents the instrumental methods used for chemical and phase composition investigation of gallstones. A great body of data has been collected in the literature on the presence of elements and their concentrations, obtained by fluorescence microscopy, X-ray fluorescence spectroscopy, neutron activation analysis, proton (particle) induced X-ray emission, atomic absorption spectroscopy, high-resolution gamma-ray spectrometry, electron paramagnetic resonance. Structural methods—powder X-ray diffraction, infrared spectroscopy, Raman spectroscopy—provide information about organic and inorganic phases in gallstones. Stone morphology was studied at the macrolevel with optical microscopy. Results obtained by analytical scanning and transmission electron microscopy with X-ray energy dispersive spectrometry are discussed. The chemical composition and structure of gallstones determine the strategy of removing stone from the body and treatment of patients: surgery or dissolution in the body. Therefore one chapter of the review describes the potential of dissolution methods. Early diagnosis and appropriate treatment of the disease depend on the development of clinical methods for in vivo investigation, which gave grounds to present the main characteristics and potential of ultrasonography (ultrasound scanning), magnetic resonance imaging, and X-ray computed tomography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Knudsen measurements of the sublimation and the heat of formation of GeSe

Knudsen effusion studies of the sublimation of polycrystalline GeSe have been performed employing mass spectrometry. The results demonstrate that GeSe vaporizes congruently under present experimental conditions according to the reaction: GeSe(s) yields GeSe(g). The mean values for the third-law heat and second-law entropy of reaction based on direct mass-loss data are 42.0 + or - 1.5 kcal/mole and 42.3 + or - 1.6 eu respectively. From these data the standard heat of formation was calculated to be -10.1 + or - 2.0 kcal/mole, and the standard absolute entropy was determined to be 16.9 + or - 2.0 eu.

Wiedemeier, H.↗

Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

In the history of manned spaceflight, environmental monitoring has relied heavily on archival sampling. For short missions, this type of sample collection was sufficient; returned samples provided a snapshot of the presence of chemical and biological contaminants in the spacecraft air and water. However, with the construction of the International Space Station (ISS) and the subsequent extension of mission durations, soon to be up to one year, the need for enhanced, real-time environmental monitoring became more pressing. The past several years have seen the implementation of several real-time monitors aboard the ISS, complemented with reduced archival sampling. The station air is currently monitored for volatile organic compounds (VOCs) using gas chromatography-differential mobility spectrometry (Air Quality Monitor [AQM]). The water on ISS is analyzed to measure total organic carbon and biocide concentrations using the Total Organic Carbon Analyzer (TOCA) and the Colorimetric Water Quality Monitoring Kit (CWQMK), respectively. The current air and water monitors provide important data, but the number and size of the different instruments makes them impractical for future exploration missions. It is apparent that there is still a need for improvements in environmental monitoring capabilities. One such improvement could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for target compounds present in air samples, and many of the compounds are also targets for water quality monitoring, this instrument provides a logical starting point to evaluate the feasibility of this approach. In this presentation, we will discuss our recent studies aimed at determining an appropriate method for introducing VOCs from water samples into the gas phase and our current work, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target analytes at the relevant concentrations at which they are routinely detected in archival water samples from the ISS.

Wallace, William T.↗

Proteomics

Proteomics aims to characterize the spatial distribution and temporal dynamics of proteins in biological systems, the protein response to environmental stimuli, and the differences in protein states between diseased and control biological systems. Mass spectrometry (MS) plays a crucial role in enabling the analysis of proteomes and typically is the method of choice for identifying proteins present in biological systems. Peptide (and consequently protein) identifications are made by comparing measured masses to calculated values obtained from genome data. Several methodologies based on MS have been developed for the analysis of proteomes. The complexity of the biological systems requires that the proteome be separated prior to analysis. Both gel based and liquid chromatography based separations have proven very useful in this regard. Typically, separated proteins are analyzed with MS either intact (top-down proteomics) or are digested into peptides (bottom-up) prior to MS analysis. Additionally, several procedures, with and without stable isotopic labeling, have been introduced to facilitate protein quantitation (e.g. characterize changes in protein abundances between given biological states).

59 BASIC BIOLOGICAL SCIENCES↗

Investigating the Effects of Chemical Gradients on Performance and Reliability within Perovskite Solar Cells with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS), a powerful analytical technique sensitive to all components of perovskite solar cell (PSC) materials, can differentiate between the various organic species within a PSC absorber or a complete device stack. The ability to probe chemical gradients through the depth of a device (both organic and inorganic), with down to 100 nm lateral resolution, can lead to unique insights into the relationships between chemistry in the absorber bulk, at grain boundaries, and at interfaces as well as how they relate to changes in performance and/or stability. In this essay, the technique is described; then, from the literature, several examples of how TOF-SIMS have been used to provide unique insight into PSC absorbers and devices are covered. Finally, the common artifacts that can be introduced if the data are improperly collected, as well as methods to mitigate these artifacts are discussed.

14 SOLAR ENERGY↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

W T Wallace↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

William T. Wallace↗

An in vivo imaging-based assay for detecting protein interactions over a wide range of binding affinities

Identifying and characterizing protein interactions are fundamental steps towards understanding and modeling biological networks. Methods that detect protein interactions in intact cells rather than buffered solutions are likely more relevant to natural systems since molecular crowding events in the cytosol can influence the diffusion and reactivity of individual proteins. One in vivo, imaging-based method relies on the co-localization of two proteins of interest fused to DivIVA, a cell division protein from Bacillus subtilis, and green fluorescent protein (GFP). We have modified this imaging-based assay to facilitate rapid cloning by constructing new vectors encoding N- and C-terminal DivIVA or GFP molecular tag fusions based on site-specific recombination technology. The sensitivity of the assay was defined using a well-characterized protein interaction system involving the eukaryotic nuclear import receptor subunit, Importin (Imp ) and variant nuclear localization signals (NLS) representing a range of binding affinities. These data demonstrate that the modified co-localization assay is sensitive enough to detect protein interactions with Kd values that span over four orders of magnitude (1nM to 15 M). Lastly, this assay was used to confirm numerous protein interactions identified from mass spectrometry-based analyses of affinity isolates as part of an interactome mapping project in Rhodopseudomonas palustris

59 BASIC BIOLOGICAL SCIENCES↗

One-pot transformation of lignocellulosic biomass into crude bio-oil with metal chlorides via hydrothermal and supercritical ethanol processing

Grape seeds were deconstructed in both hydrothermal and supercritical ethanol media with a combination of two metal chlorides (TiCl 4 :MgCl 2 ) to produce bio-oils. The use of metal chloride additives in supercritical ethanol achieved the highest bio-oil yield of 49.2 wt% (300 °C, 30 min). Both the hydrothermal and supercritical ethanol deconstruction with the additives (TiCl 4 :MgCl 2 = 4 mmol:4mmol) produced the bio-oils with a higher heating value (HHV) of 35 MJ/Kg. Here, gas chromatography-mass spectrometry (GC-MS) analysis of the bio-oils showed that the major products in bio-oils from the hydrothermal deconstruction were acids while the majority products in bio-oils form the supercritical ethanol deconstruction were esters. Nuclear magnetic resonance (NMR) data of the bio-oils suggested that both hydrothermal and supercritical ethanol deconstruction with metal chlorides significantly reduced the non-condensed OH and oxygenated lignin sub-units in bio-oils; while only supercritical ethanol deconstruction with metal chlorides reduced the aliphatic OH and O-alkylated structures in bio-oils.

09 BIOMASS FUELS↗

Tracing fetal and childhood exposure to lead using isotope analysis of deciduous teeth

We report progress in using the isotopic composition and concentration of Pb in the dentine and enamel of deciduous teeth to provide a high resolution time frame of exposure to Pb during fetal development and early childhood. Isotope measurements (total Pb and {sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb ratios) were acquired by laser ablation inductively coupled mass spectrometry at contiguous 100 micron intervals across thin sections of the teeth; from the outer enamel surface to the pulp cavity. Teeth samples (n=10) were selected from two cohorts of children, aged 5–8 years, living in NE England. By integrating the isotope data with histological analysis of the teeth, using the daily incremental lines in dentine, we were able to assign true estimated ages to each ablation point (first 2–3 years for molars, first 1–2 years for incisors+pre-natal growth). Significant differences were observed in the isotope composition and concentration of Pb between children, reflecting differences in the timing and sources of exposure during early childhood. Those born in 2000, after the withdrawal of leaded petrol in 1999, have the lowest dentine Pb levels (<0.2 µg Pb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.126–2.079) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.879–0.856) ratios that correlate very closely with modern day Western European industrial aerosols (PM{sub 10}, PM{sub 2.5}) suggesting that diffuse airborne pollution was probably the primary source and exposure pathway. Legacy lead, if present, is insignificant. For those born in 1997, dentine lead levels are typically higher (>0.4 µgPb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.145–2.117) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.898–0.882) ratios that can be modelled as a binary mix between industrial aerosols and leaded petrol emissions. Short duration, high intensity exposure events (1–2 months) were readily identified, together with evidence that dentine provides a good proxy for childhood changes in the isotope composition of blood Pb. Our pilot study confirms that laser ablation Pb isotope analysis of deciduous teeth, when carried out in conjunction with histological analysis, permits a reconstruction of the timing, duration and source of exposure to Pb during early childhood. With further development, this approach has the potential to study larger cohorts and appraise environments where the levels of exposure to Pb are much higher. - Highlights: • Reconstructing a high resolution chronology of early childhood exposure to lead. • Combined laser ablation lead isotope – histological analysis of children's teeth. • Using dentine to recover information on the intensity, duration and source of lead. • Importance of industrial airborne lead pollution in a post-leaded petrol era.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗