Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Branch Flow Model: Relaxations and Convexification-Part I

We propose a branch flow model for the analysis and optimization of mesh as well as radial networks. The model leads to a new approach to solving optimal power flow (OPF) that consists of two relaxation steps. The first step eliminates the voltage and current angles and the second step approximates the resulting problem by a conic program that can be solved efficiently. For radial networks, we prove that both relaxation steps are always exact, provided there are no upper bounds on loads. For mesh networks, the conic relaxation is always exact but the angle relaxation may not be exact, and we provide a simple way to determine if a relaxed solution is globally optimal. We propose convexification of mesh networks using phase shifters so that OPF for the convexified network can always be solved efficiently for an optimal solution. We prove that convexification requires phase shifters only outside a spanning tree of the network and their placement depends only on network topology, not on power flows, generation, loads, or operating constraints. Part I introduces our branch flow model, explains the two relaxation steps, and proves the conditions for exact relaxation. Part II describes convexification of mesh networks, and presents simulation results.

Farivar, M↗

Branch Flow Model: Relaxations and Convexification-Part II

We propose a branch flow model for the analysis and optimization of mesh as well as radial networks. The model leads to a new approach to solving optimal power flow (OPF) that consists of two relaxation steps. The first step eliminates the voltage and current angles and the second step approximates the resulting problem by a conic program that can be solved efficiently. For radial networks, we prove that both relaxation steps are always exact, provided there are no upper bounds on loads. For mesh networks, the conic relaxation is always exact but the angle relaxation may not be exact, and we provide a simple way to determine if a relaxed solution is globally optimal. We propose convexification of mesh networks using phase shifters so that OPF for the convexified network can always be solved efficiently for an optimal solution. We prove that convexification requires phase shifters only outside a spanning tree of the network and their placement depends only on network topology, not on power flows, generation, loads, or operating constraints. Part I introduces our branch flow model, explains the two relaxation steps, and proves the conditions for exact relaxation. Part II describes convexification of mesh networks, and presents simulation results.

Farivar, M↗

A Two-Stage Decomposition Approach for AC Optimal Power Flow

The alternating current optimal power flow (AC-OPF) problem is critical to power system operations and planning, but it is generally hard to solve due to its nonconvex and large-scale nature. Furthermore, this paper proposes a scalable decomposition approach in which the power network is decomposed into a master network and a number of subnetworks, where each network has its own AC-OPF subproblem. This formulates a two-stage optimization problem and requires only a small amount of communication between the master and subnetworks. The key contribution is a smoothing technique that renders the response of a subnetwork differentiable with respect to the input from the master problem, utilizing properties of the barrier problem formulation that naturally arises when subproblems are solved by a primal-dual interior-point algorithm. Consequently, existing efficient nonlinear programming solvers can be used for both the master problem and the subproblems. The advantage of this framework is that speedup can be obtained by processing the subnetworks in parallel, and it has convergence guarantees under reasonable assumptions. The formulation is readily extended to instances with stochastic subnetwork loads. Numerical results show favorable performance and illustrate the scalability of the algorithm which is able to solve instances with more than 11 million buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network-Level Optimization for Unbalanced Power Distribution System: Approximation and Relaxation

The nonlinear programming (NLP) problem to solve distribution-level optimal power flow (D-OPF) poses convergence issues and does not scale well for unbalanced distribution systems. The existing scalable D-OPF algorithms either use approximations that are not valid for an unbalanced power distribution system, or apply relaxation techniques to the nonlinear power flow equations that do not guarantee a feasible power flow solution. In this paper, we propose scalable D-OPF algorithms that simultaneously achieve optimal and feasible solutions by solving multiple iterations of approximate, or relaxed, D-OPF subproblems of low complexity. The first algorithm is based on a successive linear approximation of the nonlinear power flow equations around the current operating point, where the D-OPF solution is obtained by solving multiple iterations of a linear programming (LP) problem. The second algorithm is based on the relaxation of the nonlinear power flow equations as conic constraints together with directional constraints, which achieves optimal and feasible solutions over multiple iterations of a second-order cone programming (SOCP) problem. Finally, it is demonstrated that the proposed algorithms are able to reach an optimal and feasible solution while significantly reducing the computation time as compared to an equivalent NLPD-OPF model for the same distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Transmission and Distribution AC Optimal Power Flow

The current separate transmission and distribution energy management system faces multiple challenges associated with integrating distributed generators (DGs) into future grids. These challenges, such as a voltage rise issue resulting in curtailment of DGs, are difficult to solve via the current separate energy management. Thus, coordination between transmission and distribution is suggested, and a coordinated transmission and distribution AC optimal power flow (TDOPF) is proposed in this paper. A mathematical TDOPF model is established and analyzed in a master-slave structure. A heterogeneous decomposition algorithm (HGD), which is inspired by heterogeneous transmission and distribution characteristics, is proposed to solve the TDOPF in a distributed manner. The HGD is compared to other typical multi-area OPF decomposition algorithms and the differences are discussed. Numerical tests verify the benefit of the TDOPF to both transmission and distribution systems. The TDOPF improves economic operations, mitigates voltage rises, and decreases boundary bus mismatches. Hence, more DGs can be accommodated by the grid. In addition, a series of numerical tests indicate that the HGD competitively solves the TDOPF.

decomposition↗

A Novel Framework for Optimizing Ramping Capability of Hybrid Energy Storage Systems

Hybrid Energy Storage System has been widely applied in aerospace, electric vehicle, and microgrid applications. The advantages are that they include complimentary technologies with both high power and energy capabilities. HESS have the potential to be useful to the bulk power systems, for example to increase the value of energy produced by variable generation resource through enabling participation in ancillary service markets. Actualizing the benefits of HESSs requires optimizing the combined ramping capability of aggregated HESS resources. To provide quality ancillary service, source of HESSs locating at multiple sites of variable generation resource must be optimally sized and cohesively controlled. Optimizing aggregated resources can be formulated as an optimization problem. Successfully solving this problem not only requires using effective solution methods but also depends on accurately and rapidly setting the necessary parameters in the problem formula. This article proposes a novel framework with double-layer structure to solve the optimization problem of aggregating ramping capability. Program developed on the upper layer focuses on solving the optimization of aggregating ramping capability among multiple HESSs and is compatible with most existing optimization algorithms. Program on lower layer of the framework targets at optimizing the local control of a single HESS based on a thorough analytics of HESS operation strategy presented in this article. Result of local optimization is also provided to upper layer program for updating the parameters in formula of optimization problem. Real time hardware-in-the-loop test is conducted to verify the performance of the optimization framework developed. The work presented is expected to provide guidance for implementing this framework in practical operation.

Luo, Yushen↗

Physics-Informed Neural Networks for Heat Transfer Problems

Abstract Physics-informed neural networks (PINNs) have gained popularity across different engineering fields due to their effectiveness in solving realistic problems with noisy data and often partially missing physics. In PINNs, automatic differentiation is leveraged to evaluate differential operators without discretization errors, and a multitask learning problem is defined in order to simultaneously fit observed data while respecting the underlying governing laws of physics. Here, we present applications of PINNs to various prototype heat transfer problems, targeting in particular realistic conditions not readily tackled with traditional computational methods. To this end, we first consider forced and mixed convection with unknown thermal boundary conditions on the heated surfaces and aim to obtain the temperature and velocity fields everywhere in the domain, including the boundaries, given some sparse temperature measurements. We also consider the prototype Stefan problem for two-phase flow, aiming to infer the moving interface, the velocity and temperature fields everywhere as well as the different conductivities of a solid and a liquid phase, given a few temperature measurements inside the domain. Finally, we present some realistic industrial applications related to power electronics to highlight the practicality of PINNs as well as the effective use of neural networks in solving general heat transfer problems of industrial complexity. Taken together, the results presented herein demonstrate that PINNs not only can solve ill-posed problems, which are beyond the reach of traditional computational methods, but they can also bridge the gap between computational and experimental heat transfer.

Engineering↗

Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT)

Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider a cost function consisting two terms, the first enforcing a desired dose distribution and the second guaranteeing a smooth dose rate variation between successive gantry angles. A gantry rotation is discretized into 180 beam angles and for each beam angle, only one MLC aperture is allowed. The apertures are generated one by one in a sequential way. At each iteration of the column generation method, a deliverable MLC aperture is generated for one of the unoccupied beam angles by solving a subproblem with the consideration of MLC mechanic constraints. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. When all 180 beam angles are occupied, the optimization completes, yielding a set of deliverable apertures and associated dose rates that produce a high quality plan. Results: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation without any couch/collimator rotations. High quality VMAT plans have been generated for all ten cases with extremely high efficiency. It takes only 5-8 min on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18-31 s on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such plans. Conclusions: The authors have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable high quality treatment plans at very high efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗

A voxel-based finite element model for the prediction of bladder deformation

Purpose: A finite element (FE) bladder model was previously developed to predict bladder deformation caused by bladder filling change. However, two factors prevent a wide application of FE models: (1) the labor required to construct a FE model with high quality mesh and (2) long computation time needed to construct the FE model and solve the FE equations. In this work, we address these issues by constructing a low-resolution voxel-based FE bladder model directly from the binary segmentation images and compare the accuracy and computational efficiency of the voxel-based model used to simulate bladder deformation with those of a classical FE model with a tetrahedral mesh. Methods: For ten healthy volunteers, a series of MRI scans of the pelvic region was recorded at regular intervals of 10 min over 1 h. For this series of scans, the bladder volume gradually increased while rectal volume remained constant. All pelvic structures were defined from a reference image for each volunteer, including bladder wall, small bowel, prostate (male), uterus (female), rectum, pelvic bone, spine, and the rest of the body. Four separate FE models were constructed from these structures: one with a tetrahedral mesh (used in previous study), one with a uniform hexahedral mesh, one with a nonuniform hexahedral mesh, and one with a low-resolution nonuniform hexahedral mesh. Appropriate material properties were assigned to all structures and uniform pressure was applied to the inner bladder wall to simulate bladder deformation from urine inflow. Performance of the hexahedral meshes was evaluated against the performance of the standard tetrahedral mesh by comparing the accuracy of bladder shape prediction and computational efficiency. Results: FE model with a hexahedral mesh can be quickly and automatically constructed. No substantial differences were observed between the simulation results of the tetrahedral mesh and hexahedral meshes (<1% difference in mean dice similarity coefficient to manual contours and <0.02 cm difference in mean standard deviation of residual errors). The average equation solving time (without manual intervention) for the first two types of hexahedral meshes increased to 2.3 h and 2.6 h compared to the 1.1 h needed for the tetrahedral mesh, however, the low-resolution nonuniform hexahedral mesh dramatically decreased the equation solving time to 3 min without reducing accuracy. Conclusions: Voxel-based mesh generation allows fast, automatic, and robust creation of finite element bladder models directly from binary segmentation images without user intervention. Even the low-resolution voxel-based hexahedral mesh yields comparable accuracy in bladder shape prediction and more than 20 times faster in computational speed compared to the tetrahedral mesh. This approach makes it more feasible and accessible to apply FE method to model bladder deformation in adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First-order convex feasibility algorithms for x-ray CT

Purpose: Iterative image reconstruction (IIR) algorithms in computed tomography (CT) are based on algorithms for solving a particular optimization problem. Design of the IIR algorithm, therefore, is aided by knowledge of the solution to the optimization problem on which it is based. Often times, however, it is impractical to achieve accurate solution to the optimization of interest, which complicates design of IIR algorithms. This issue is particularly acute for CT with a limited angular-range scan, which leads to poorly conditioned system matrices and difficult to solve optimization problems. In this paper, we develop IIR algorithms which solve a certain type of optimization called convex feasibility. The convex feasibility approach can provide alternatives to unconstrained optimization approaches and at the same time allow for rapidly convergent algorithms for their solution-thereby facilitating the IIR algorithm design process. Methods: An accelerated version of the Chambolle-Pock (CP) algorithm is adapted to various convex feasibility problems of potential interest to IIR in CT. One of the proposed problems is seen to be equivalent to least-squares minimization, and two other problems provide alternatives to penalized, least-squares minimization. Results: The accelerated CP algorithms are demonstrated on a simulation of circular fan-beam CT with a limited scanning arc of 144 Degree-Sign . The CP algorithms are seen in the empirical results to converge to the solution of their respective convex feasibility problems. Conclusions: Formulation of convex feasibility problems can provide a useful alternative to unconstrained optimization when designing IIR algorithms for CT. The approach is amenable to recent methods for accelerating first-order algorithms which may be particularly useful for CT with limited angular-range scanning. The present paper demonstrates the methodology, and future work will illustrate its utility in actual CT application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control algorithms for dynamic attenuators

Purpose: The authors describe algorithms to control dynamic attenuators in CT and compare their performance using simulated scans. Dynamic attenuators are prepatient beam shaping filters that modulate the distribution of x-ray fluence incident on the patient on a view-by-view basis. These attenuators can reduce dose while improving key image quality metrics such as peak or mean variance. In each view, the attenuator presents several degrees of freedom which may be individually adjusted. The total number of degrees of freedom across all views is very large, making many optimization techniques impractical. The authors develop a theory for optimally controlling these attenuators. Special attention is paid to a theoretically perfect attenuator which controls the fluence for each ray individually, but the authors also investigate and compare three other, practical attenuator designs which have been previously proposed: the piecewise-linear attenuator, the translating attenuator, and the double wedge attenuator. Methods: The authors pose and solve the optimization problems of minimizing the mean and peak variance subject to a fixed dose limit. For a perfect attenuator and mean variance minimization, this problem can be solved in simple, closed form. For other attenuator designs, the problem can be decomposed into separate problems for each view to greatly reduce the computational complexity. Peak variance minimization can be approximately solved using iterated, weighted mean variance (WMV) minimization. Also, the authors develop heuristics for the perfect and piecewise-linear attenuators which do not requirea priori knowledge of the patient anatomy. The authors compare these control algorithms on different types of dynamic attenuators using simulated raw data from forward projected DICOM files of a thorax and an abdomen. Results: The translating and double wedge attenuators reduce dose by an average of 30% relative to current techniques (bowtie filter with tube current modulation) without increasing peak variance. The 15-element piecewise-linear dynamic attenuator reduces dose by an average of 42%, and the perfect attenuator reduces dose by an average of 50%. Improvements in peak variance are several times larger than improvements in mean variance. Heuristic control eliminates the need for a prescan. For the piecewise-linear attenuator, the cost of heuristic control is an increase in dose of 9%. The proposed iterated WMV minimization produces results that are within a few percent of the true solution. Conclusions: Dynamic attenuators show potential for significant dose reduction. A wide class of dynamic attenuators can be accurately controlled using the described methods.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-9A-03: Simultaneous Deconvolution and Segmentation for PET Tumor Delineation Using a Variational Method

Purpose: To implement a new method that integrates deconvolution with segmentation under the variational framework for PET tumor delineation. Methods: Deconvolution and segmentation are both challenging problems in image processing. The partial volume effect (PVE) makes tumor boundaries in PET image blurred which affects the accuracy of tumor segmentation. Deconvolution aims to obtain a PVE-free image, which can help to improve the segmentation accuracy. Conversely, a correct localization of the object boundaries is helpful to estimate the blur kernel, and thus assist in the deconvolution. In this study, we proposed to solve the two problems simultaneously using a variational method so that they can benefit each other. The energy functional consists of a fidelity term and a regularization term, and the blur kernel was limited to be the isotropic Gaussian kernel. We minimized the energy functional by solving the associated Euler-Lagrange equations and taking the derivative with respect to the parameters of the kernel function. An alternate minimization method was used to iterate between segmentation, deconvolution and blur-kernel recovery. The performance of the proposed method was tested on clinic PET images of patients with non-Hodgkin's lymphoma, and compared with seven other segmentation methods using the dice similarity index (DSI) and volume error (VE). Results: Among all segmentation methods, the proposed one (DSI=0.81, VE=0.05) has the highest accuracy, followed by the active contours without edges (DSI=0.81, VE=0.25), while other methods including the Graph Cut and the Mumford-Shah (MS) method have lower accuracy. A visual inspection shows that the proposed method localizes the real tumor contour very well. Conclusion: The result showed that deconvolution and segmentation can contribute to each other. The proposed variational method solve the two problems simultaneously, and leads to a high performance for tumor segmentation in PET. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant Nos. 60971112 and 61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-BRD-10: An Evaluation of Three Robust Optimization Approaches in IMPT Treatment Planning

Purpose: Various robust optimization approaches have been proposed to ensure the robustness of intensity modulated proton therapy (IMPT) in the face of uncertainty. In this study, we aim to investigate the performance of three classes of robust optimization approaches regarding plan optimality and robustness. Methods: Three robust optimization models were implemented in our in-house IMPT treatment planning system: 1) L2 optimization based on worst-case dose; 2) L2 optimization based on minmax objective; and 3) L1 optimization with constraints on all uncertain doses. The first model was solved by a L-BFGS algorithm; the second was solved by a gradient projection algorithm; and the third was solved by an interior point method. One nominal scenario and eight maximum uncertainty scenarios (proton range over and under 3.5%, and setup error of 5 mm for x, y, z directions) were considered in optimization. Dosimetric measurements of optimized plans from the three approaches were compared for four prostate cancer patients retrospectively selected at our institution. Results: For the nominal scenario, all three optimization approaches yielded the same coverage to the clinical treatment volume (CTV) and the L2 worst-case approach demonstrated better rectum and bladder sparing than others. For the uncertainty scenarios, the L1 approach resulted in the most robust CTV coverage against uncertainties, while the plans from L2 worst-case were less robust than others. In addition, we observed that the number of scanning spots with positive MUs from the L2 approaches was approximately twice as many as that from the L1 approach. This indicates that L1 optimization may lead to more efficient IMPT delivery. Conclusion: Our study indicated that the L1 approach best conserved the target coverage in the face of uncertainty but its resulting OAR sparing was slightly inferior to other two approaches.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-01: A 3D Solver of Linear Boltzmann Transport Equation Based On a New Angular Discretization Method with Positivity for Photon Dose Calculation Benchmarked with Geant4

Purpose: The Linear Boltzmann Transport Equation (LBTE) solved through statistical Monte Carlo (MC) method provides the accurate dose calculation in radiotherapy. This work is to investigate the alternative way for accurately solving LBTE using deterministic numerical method due to its possible advantage in computational speed from MC. Methods: Instead of using traditional spherical harmonics to approximate angular scattering kernel, our deterministic numerical method directly computes angular scattering weights, based on a new angular discretization method that utilizes linear finite element method on the local triangulation of unit angular sphere. As a Result, our angular discretization method has the unique advantage in positivity, i.e., to maintain all scattering weights nonnegative all the time, which is physically correct. Moreover, our method is local in angular space, and therefore handles the anisotropic scattering well, such as the forward-peaking scattering. To be compatible with image-guided radiotherapy, the spatial variables are discretized on the structured grid with the standard diamond scheme. After discretization, the improved sourceiteration method is utilized for solving the linear system without saving the linear system to memory. The accuracy of our 3D solver is validated using analytic solutions and benchmarked with Geant4, a popular MC solver. Results: The differences between Geant4 solutions and our solutions were less than 1.5% for various testing cases that mimic the practical cases. More details are available in the supporting document. Conclusion: We have developed a 3D LBTE solver based on a new angular discretization method that guarantees the positivity of scattering weights for physical correctness, and it has been benchmarked with Geant4 for photon dose calculation.

97 MATHEMATICS AND COMPUTING↗

TH-E-BRE-02: A Forward Scattering Approximation to Dose Calculation Using the Linear Boltzmann Transport Equation

Purpose: To investigate the use of the linear Boltzmann transport equation as a dose calculation tool which can account for interface effects, while still having faster computation times than Monte Carlo methods. In particular, we introduce a forward scattering approximation, in hopes of improving calculation time without a significant hindrance to accuracy. Methods: Two coupled Boltzmann transport equations were constructed, one representing the fluence of photons within the medium, and the other, the fluence of electrons. We neglect the scattering term within the electron transport equation, resulting in an extreme forward scattering approximation to reduce computational complexity. These equations were then solved using a numerical technique for solving partial differential equations, known as a finite difference scheme, where the fluence at each discrete point in space is calculated based on the fluence at the previous point in the particle's path. Using this scheme, it is possible to develop a solution to the Boltzmann transport equations by beginning with boundary conditions and iterating across the entire medium. The fluence of electrons can then be used to find the dose at any point within the medium. Results: Comparisons with Monte Carlo simulations indicate that even simplistic techniques for solving the linear Boltzmann transport equation yield expected interface effects, which many popular dose calculation algorithms are not capable of predicting. Implementation of a forward scattering approximation does not appear to drastically reduce the accuracy of this algorithm. Conclusion: Optimized implementations of this algorithm have been shown to be very accurate when compared with Monte Carlo simulations, even in build up regions where many models fail. Use of a forward scattering approximation could potentially give a reasonably accurate dose distribution in a shorter amount of time for situations where a completely accurate dose distribution is not required, such as in certain optimization algorithms.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-270: Diffusion Synthetic Acceleration for Linear Boltzmann Transport Equation

Purpose: Linear Boltzmann transport equation (LBTE) is as accurate as the Monte Carlo method (MC) for dose calculation in photon/particle therapy (LBTE is a deterministic and Eulerian formulation and MC is a statistical and Lagrangian description). An advantage of LBTE is that numerous acceleration techniques can be utilized for acceleration. This work is to explore the acceleration of LBTE via diffusion synthetic acceleration (DSA). Methods: For simplicity, two-dimensional, steady-state, and within-group LBTE is considered with two angular dimensions and two spatial dimensions. The discrete ordinate method is developed for solving this integro-differential equation. The angular variables are discretized using a level-symmetric quadrature set on the unit sphere. The spatial variables are discretized on the structured grid based on the diamond scheme. The source-iteration method (SI) is used to solve the discretized system.Since SI is slow in optically thick and highly scattering regime. DSA is developed to accelerate SI. The motivation for DSA is that diffusion equation (DE) is a good approximation of LBTE in the above regime. However, DE is much cheaper than LBTE computationally since DE only involves spatial variables. Thus, in each DSA iteration, DSA adds to the SI step a computationally-negligible DE step, i.e., to first solve DE with the SI residual as source term, and then compensate the SI solution with DE solution. Results: DSA was benchmarked and compared with SI. The difference between two methods was within 0.12% which verifies the accuracy of DSA, while DSA demonstrated the great advantage in speed, e.g., the reduction of iteration number to 6% and 4% respectively for cases with 100 and 1,000 scattering-absorption ratio that commonly occur in clinical dose calculation. Conclusion: DSA has been developed as one of many possible means for accelerating the numerical solver of LBTE for dose calculation. The authors were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

WE-D-213-04: Preparing for Parts 2 & 3 of the ABR Nuclear Medicine Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

WE-D-213-00: Preparing for the ABR Diagnostic and Nuclear Medicine Physics Exams

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗