Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “separability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Charge Separation at the Evaporation (Condensation) Front of Water and Ice. Charging of Spherical Droplets

Charge separation at evaporation (condensation) front of water and ice is analyzed. Relatively low distribution coefficient of protons and hydroxide ions between vapor and condensed phase that is less than the distribution coefficient of water molecules leads to accumulation of protons and hydroxide ions at the phase front upon evaporation and a decrease in the amount of such species upon condensation. Interphase charge separation is caused by the subsequent diffusion of nonequilibrium protons and hydroxide ions. The charge separation is also affected by the double electric layer generated by orientation defects at the water and ice surfaces. Dependences of electric field at a plane surface of water and ice on the rate of phase transformation are calculated. Electric charges of spherical water droplets are estimated at different field strengths and droplet radii.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cherenkov and scintillation light separation in organic liquid scintillators

The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3 % and 63 ± 8 % for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5 % and 38 ± 4 %. LAB/PPO data is consistent with a rise time of τ r = 0.72 ± 0.33 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cherenkov and scintillation separation in water-based liquid scintillator using an LAPPDTM

Abstract This manuscript describes measurements of water-based liquid scintillators (WbLS), demonstrating separation of the Cherenkov and scintillation components using a low energy $$\beta $$ β source and the fast timing response of a Large Area Picosecond Photodetector (LAPPD). Additionally, the time profiles of three WbLS mixtures, defined by the relative fractions of scintillating compound, are characterized, with improved sensitivity to the scintillator rise-time. The measurements were made using both an LAPPD and a conventional photomultiplier tube (PMT). All samples were measured with an effective resolution $$O\left( 100~\text {ps}\right) $$ O 100 ps , which allows for the separation of Cherenkov and scintillation light (henceforth C/S separation) by selecting on the arrival time of the photons alone. The Cherenkov purity of the selected photons is greater than 60% in all cases, with greater than 80% achieved for a sample containing 1% scintillator. This is the first demonstration of the power of synthesizing low light yield scintillators, of which WbLS is the canonical example, with fast photodetectors, of which LAPPDs are an emerging leader, and has direct implication for future mid- and large-scale detectors, such as Theia , ANNIE, and AIT-NEO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of stretching a flexible polyelectrolyte with varying charge separation

We calculated the force-extension curves for a flexible polyelectrolyte chain with varying charge separations by performing Monte Carlo simulations of a 5000 bead chain using a screened Coulomb interaction. At all charge separations, the force-extension curves exhibit a Pincus-like scaling regime at intermediate forces and a logarithmic regime at large forces. As the charge separation increases, the Pincus regime shifts to a larger range of forces and the logarithmic regime starts are larger forces. We also found that force-extension curve for the corresponding neutral chain has a logarithmic regime. Decreasing the diameter of bead in the neutral chain simulations removed the logarithmic regime, and the force-extension curve tends to the freely jointed chain limit. In conclusion, this result shows that only excluded volume is required for the high force logarithmic regime to occur.

97 MATHEMATICS AND COMPUTING↗

Phase-Separated, Epitaxial, Nanostructured LaMnO 3 +MgO Composite Cap Layer Films for Propagation of Pinning Defects in YBa 2 Cu 3 O 7-x Coated Conductors

Nanostructural modulation in the cap layer used in coated conductors can be a potential source for nucleating microstructural defects into the superconducting layer for improving the flux-pinning. We report on the successful fabrication of phase separated, epitaxial, nanostructured films comprised of LaMnO{sub 3} (LMO) and MgO via pulsed laser deposition (PLD) on biaxially-textured MgO metallic templates with a LMO buffer layer. Scanning Auger compositional mapping and transmission electron microscopy cross sectional images confirm the nanoscale, spatial modulation corresponding to the nanostructured phase separation in the film. YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} films (0.8 {micro}m thick) grown using PLD on such phase separated, nanostructured cap layers show reduced field dependence of the critical current density with an ? value of -0.38 (in J{sub c}-H{sup -{alpha}}).

36 MATERIALS SCIENCE↗

Realizing the Potential of Micro-Phase Separated Block Copolymer Electrolytes: Ion Domain Connectivity Plays a Prominent Role in Ion Conduction

Block copolymer electrolytes (BCEs) offer the prospect of membranes with high ionic conductivity at lower ion-exchange capacities leading to membranes with robust mechanical properties. However, the microphase separated structure of such BCE membranes and its impact on membrane conductivity is poorly understood. Most studies assume that aggregated ionic domains in microphase separated BCEs, or random copolymers, is sufficient to foster facile ion conductivity. However, microphase separation alone cannot spur rapid ion conduction. In this paper, we demonstrate that ion domain connectivity greatly influences ion conductivity in BCEs. The results emphasize the importance of maximizing ion domain connectivity while minimizing terminal defects to realize BCEs with optimal ion transport properties.

36 MATERIALS SCIENCE↗

Ion Conduction in Microphase-Separated Block Copolymer Electrolytes

Microphase separation of block copolymers provides a promising route towards engineering a mechanically robust ion conducting film for electrochemical devices. The separation into two different nano-domains enables the film to simultaneously exhibit both high ion conductivity and mechanical robustness, material properties inversely related in most homopolymer and random copolymer electrolytes. To exhibit the maximum conductivity and mechanical robustness, both domains would span across macroscopic length scales enabling uninterrupted ion conduction. One way to achieve this architecture is through external alignment fields that are applied during the microphase separation process. In this review, we present the progress and challenges for aligning the ionic domains in block copolymer electrolytes. A survey of alignment and characterization is followed by a discussion of how the nanoscale architecture affects the bulk conductivity and how alignment may be improved to maximize the number of participating conduction domains.

Kambe, Yu (ORCID:000000021422350X)↗

A single column separation method for barium isotope analysis of geologic and hydrologic materials with complex matrices

Abstract The increasing significance of barium (Ba) in environmental and geologic research in recent years has led to interest in the application of the Ba isotopic composition as a tracer for natural materials with complex matrices. Most Ba isotope measurement techniques require separation of Ba from the rest of sample prior to analysis. This paper presents a method using readily available materials and disposable columns that effectively separates Ba from a range of geologic and hydrologic materials, including carbonate minerals, silicate rocks, barite, river water, and fluids with high total dissolved solids and organic content such as oil and gas brines, rapidly and without need for an additional cleanup column. The technique involves off-the-shelf columns and cation exchange resin and a two-reagent elution that uses 2.5 N HCl followed by addition of 2.0 N HNO 3 . We present data to show that major matrix elements from almost any natural material are separated from Ba in a single column pass, and that the method also effectively reduces or eliminates isobaric interferences from lanthanum and cerium.

Matecha, R. M.↗

Doping fluctuation-driven magneto-electronic phase separation in La{sub 1-x}SrxCoO{sub 3} single crystals.

In recent years it has become clear that complex oxides provide an exceptional platform for the discovery of new physics as well as a considerable challenge to our understanding of correlated electrons. The tendency of these materials to display nanoscale electronic and magnetic inhomogeneity is a good example. Here, we have applied a variety of experimental techniques to investigate this magneto-electronic phase separation in a model system - the doped cobaltite La{sub 1-x}Sr{sub x}CoO{sub 3}. Comparing experimental data over a wide range of doping with statistical simulations, we conclude that the magneto-electronic inhomogeneity is driven solely by inevitable local compositional fluctuations at nanoscopic length scales. The phase separation is thus doping fluctuation-driven rather than electronically driven, meaning that more complex electronic phase separation models are not required to understand the observed phenomena in this material.

36 MATERIALS SCIENCE↗

Direct Analysis of Reversed-Phase HPTLC Separated Tryptic Protein Digests using a Liquid Microjunction Surface Sampling Probe/ESI-MS System

The sampling, ionization and detection of tryptic peptides separated in one-dimension on reversed phase HPTLC plates was performed using liquid microjunction surface sampling probe electrospray ionization mass spectrometry. Tryptic digests of five proteins (cytochrome c., myoglobin, beta-casein, lysozyme, and bovine serum albumin) were spotted on reversed phase HPTLC RP-8 F254s and HPTLC RP-18 F254s plates. The plates were then developed using 70/30 methanol/water with 0.1 M ammonium acetate. A dual purpose extraction/electrospray solution containing 70/30/0.1 water/methanol/formic acid was infused through the sampling probe during analysis of the developed lanes. Both full scan mass spectra and data dependent tandem mass spectra were acquired for each development lane to detect and verify the peptide distributions. Data dependent tandem mass spectra provided both protein identification and sequence coverage information. Highest sequence coverages were achieved for cytochrome c. and myoglobin (62.5% and 58.3%, respectively) on reversed phase RP-8 plates. While the tryptic peptides were separated enough for identification, the peptide bands did show some overlap with most peptides located in the lower half of the development lane. Proteins whose peptides were more separated gave higher sequence coverage. Larger proteins such as beta-casein and BSA which were spotted in lower relative amounts gave much lower sequence coverage than the smaller proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced capacity and stability for the separation of cesium in electrically switched ion exchange

Electrically switched ion exchange (ESIX) can be used to separate ionic contaminants from industrial wastewater, including that generated by the nuclear industry. The ESIX method involves sequential application of reduction and oxidation potentials to an ion exchange film to induce the respective loading and unloading of cesium. This technology is superior to conventional methods (e.g electrodialysis reversal or reverse osmosis) as it requires very little energy for ionic separation. In previous studies, ESIX films have demonstrated relatively low ion exchange capacities and limited film stabilities over repeated potential applications. In this study, the methodology for the deposition of electro-active films (nickel hexacyanoferrate) on nickel electrodes was modified to improve the ion exchange capacity for cesium removal using ESIX. Cyclic voltammetry was used to investigate the ion exchange capacity and stability. Scanning electron microscopy (SEM) was used to characterize the modified film surfaces. Additionally, the films were examined for the separation of cesium ions. This modified film preparation technique enhanced the ion exchange capacity and improves the film stability compared to previous methods for the deposition of ESIX films. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Discovery of Innovative Polymers for Next-Generation Gas-Separation Membranes using Interpretable Machine Learning

Polymer membranes perform innumerable separations with far-reaching environmental implications. Despite decades of research on membrane technologies, design of new membrane materials remains a largely Edisonian process. To address this shortcoming, we demonstrate a generalizable, accurate machine-learning (ML) implementation for the discovery of innovative polymers with ideal separation performance. Specifically, multitask ML models are trained on available experimental data to link polymer chemistry to gas permeabilities of He, H2, O2, N2, CO2, and CH4. Here, we interpret the ML models and extract chemical heuristics for membrane design, through Shapley Additive exPlanations (SHAP) analysis. We then screen over nine million hypothetical polymers through our models and identify thousands of candidates that lie well above current performance upper bounds. Notably, we discover hundreds of never-before-seen ultrapermeable polymer membranes with O2 and CO2 permeability greater than 104 and 105 Barrer, respectively. These hypothetical polymers are capable of overcoming undesirable trade-off relationship between permeability and selectivity, thus significantly expanding the currently limited library of polymer membranes for highly efficient gas separations. High-fidelity molecular dynamics simulations confirm the ML-predicted gas permeabilities of the promising candidates, which suggests that many can be translated to reality.

Yang, Jason↗

Hydrogen separation membranes annual report for FY 2010.

The objective of this work is to develop dense ceramic membranes for separating hydrogen from other gaseous components in a nongalvanic mode, i.e., without using an external power supply or electrical circuitry. The goal of this project is to develop dense hydrogen transport membranes (HTMs) that nongalvanically (i.e., without electrodes or external power supply) separate hydrogen from gas mixtures at commercially significant fluxes under industrially relevant operating conditions. These membranes will be used to separate hydrogen from gas mixtures such as the product streams from coal gasification, methane partial oxidation, and water-gas shift reactions. Potential ancillary uses of HTMs include dehydrogenation and olefin production, as well as hydrogen recovery in petroleum refineries and ammonia synthesis plants, the largest current users of deliberately produced hydrogen. This report describes the results from the development and testing of HTM materials during FY 2010.

01 COAL, LIGNITE, AND PEAT↗

Dynamic Absorption Model for Off-Gas Separation

Modeling and simulations will aid in the future design of U.S. advanced reprocessing plants for the recovery and recycle of actinides in used nuclear fuel. The specific fuel cycle separation process discussed in this report is the off-gas treatment system. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, a rate based, dynamic absorption model is being developed in gPROMS software. Inputs include liquid and gas stream constituents, column properties, liquid and gas phase reactions, number of stages, and inlet conditions. It simulates multiple component absorption with countercurrent flow and accounts for absorption by mass transfer and chemical reaction. The assumption of each stage being a discrete well-mixed entity was made. Therefore, the model is solved stagewise. The simulation outputs component concentrations in both phases as a function of time from which the rate of absorption is determined. Temperature of both phases is output as a function of time also. The model will be used able to be used as a standalone model in addition to in series with other off-gas separation unit operations. The current model is being generated based on NOx absorption; however, a future goal is to develop a CO2 specific model. The model will have the capability to be modified for additional absorption systems. The off-gas models, both adsorption and absorption, will be made available via the server or web for evaluation by customers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metal-organic and zeolite imidazolate frameworks (MOFs and ZIFs) for highly selective separations

Metal-organic and zeolite imidazolate frameworks (MOFs and ZIFs) have been investigated for the realization as separation media with high selectivity. These structures are held together with strong bonds, making them architecturally, chemically, and thermally stable. Therefore, employing well designed building units, it is possible to discover promising materials for gas and vapor separation. This grant was focused on the study of MOFs and ZIFs with these specific objectives: (i) to develop a strategy for producing MOFs and ZIFs that combine high surface areas with active sites for their use in gas adsorption and separation of small organic compounds, (ii) to introduce active sites in the framework by a post-synthetic modification and metalation of MOFs and ZIFs, and (iii) to design and synthesize MOFs with extremely high surface areas and large pore volumes to accommodate large amounts of guest molecules. By the systematic study, this effort demonstrated how to introduce active functional groups in the frameworks, and this is also the origin of a new strategy, which is termed isoreticular functionalization and metalation. However, a large pore volume is still a prerequisite feature. One of the solutions to overcome this challenge is an isoreticular expansion of a MOF's structure. With triangular organic linker and square building units, we demonstrated that MOF-399 has a unit cell volume 17 times larger than that of the first reported material isoreticular to it, and it has the highest porosity (94%) and lowest density (0.126 g cm -3 ) of any MOF reported to date. MOFs are not just low density materials; the guest-free form of MOF-210 demonstrates an ultrahigh porosity, whose BET surface area was estimated to be 6240 m 2 g -1 by N 2 adsorption measurements.

36 MATERIALS SCIENCE↗

Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 2: 2D Fast GC Separations

Conventional analysis by gas chromatography/ quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (~10 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm id) columns, and improved mass resolution and scan speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better instrument detection limits than quadrupole GC/MS, while still providing full mass spectral data. If the GC/TOF-MS can be operated to perform two-dimensional (2D) separations, the ability to resolve peaks of interest from interfering compounds is improved. In 2D chromatography, a second GC column with a different chemical phase than that of the first GC column is used to provide additional separation of analytes as they elute from the first column. Because the chemistry of the second GC column is different from the first, compounds that co-elute from the first column may be easily resolved after a separation on the second GC column (i.e., the peak capacity of the system is increased and the specificity of analyte detection is improved).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Palladium Membrane Scale-up for Hydrogen Separation

The main objective of this project was to construct, test, and demonstrate a Pd-Cu metallic tubular membrane micro-channel separator capable of producing 2 lb day -1 H 2 at 95% recovery when operating downstream of an actual coal gasifier. A key milestone for the project was to complete a pilot-scale gasifier test by 1 September 2011 and demonstrate the separation of 2 lb day -1 H 2 to verify progress toward the DOE's goals prior to down-selection for larger-scale (100 lb day -1 ) hydrogen separator development.

08 HYDROGEN↗