Advanced surface treatments for medium-velocity superconducting cavities for high-accelerating gradient continuous-wave operation
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.
The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X--Y--U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using simple standard PCB fabrication techniques. Capacitive-sharing (X--Y--U)-strip readout allows simultaneous measurement of the Cartesian coordinates x and y of the position of the particles together with a third coordinate u along the diagonal axis in a single readout PCB. This provides a powerful tool to address multiple-hit ambiguity and enable pattern recognition capabilities in moderate particle flux environment of collider or fixed target experiments in high energy physics HEP) and nuclear physics (NP). We present in this paper the performance of a 10 cm × 10 cm triple-GEM detector with capacitive-sharing (X--Y--U)-strip anode readout. Spatial resolutions of the order of $\sigma_{x}^{res}$ = 71.6 $\pm$ 0.8 $\mu$m for X-strips, $\sigma_{y}^{res}$ = 56.2 $\pm$ 0.9 $\mu$m for Y-strips and $\sigma_{u}^{res}$ = 75.2 $\pm$ 0.9 $\mu$m for U-strips have been obtained at a beam test at Thomas Jefferson National Accelerator Facility (Jefferson Lab). Modifications of the readout design of future prototypes to improve the spatial resolution and challenges in scaling to large-area MPGDs are discussed.
The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.
The Mu2e experiment at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photo-multipliers and fast front-end, and digitization electronics. The digitization board is named DiRAC (Digitizer ReAdout Controller) and 140 cards are needed for the readout of the full calorimeter. The DiRACs are hosted in crates located on the external surface of calorimeter disks, inside the detector solenoid cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. Several version of prototypes were validated for operation in a high-vacuum (10−4 Torr) and under a 1T magnetic field. An extensive radiation hardness qualification campaign, carried out with photons, 14 MeV neutron beams, and 200 MeV protons, certified the DiRAC design to sustain doses up to 12 Krad, neutron fluences up to ∼ 1011 1 MeV neq/cm2, and very low occurrences of single-event effects. The qualification campaigns and quality assurance procedures will be reviewed.
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.
Here, we present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effectively confined, and read out through wavelength-shifting fibers. The 1-liter, 32-channel prototype demonstrates the capability for both spectroscopy and topological reconstruction of point-like events. The design, construction, and evaluation of the detector are described, including modeling of the scintillation liquid optical properties and the detector’s response to gamma rays of several energies. A mean position reconstruction error of 4.4 mm for 1.6 MeV-equivalent events and 7.4 mm for 0.8 MeV-equivalent events is demonstrated using a simple reconstruction approach analogous to center-of-mass.
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.
This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.
Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.
Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.
Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.
The dual radiator Ring Imaging Cherenkov (dRICH) detector is required to provide continuous hadron identification from ≈3 GeV/c up to ≈50 GeV/c, and to supplement electron and positron identification from a few hundred MeV/c up to about 15 GeV/c, in the forward (ion-side) end-cap of the ePIC experiment. Such an extended momentum range imposes the use of two radiators, gas and aerogel. The common imaging system, that ensures compactness and cost-effectiveness, is based on SiPM sensors to work in a high non-uniform magnetic field. During the R&D phase, the dual radiator principle and the single component performance have been validated. A status overview of the project is presented. The design and technological choices are discussed together with the results obtained from laboratory characterization of the component demonstrators and beam tests of the evolving prototypes.
This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.
Transition Radiation Detectors (TRDs) are widely used for particle identification in both high-energy physics and astroparticle physics. They are typically equipped with gaseous detectors. The main limitation of these types of detectors is that TR photons and ionization losses cannot be decoupled, which significantly reduces the particle separation power. Recent advancements in the development of pixel detectors based on GaAs sensors offer a unique opportunity to effectively detect TR photons and separate them from ionization losses. Such detectors represent novel devices that combine precise tracking capabilities with particle identification (PID) properties. The present work is dedicated to an experimental study of particle identification properties of the TRD prototype based on 500 μ m-thick GaAs sensor bonded to a Timepix3 chip. Studies were performed at the CERN SPS and it was shown that at a particle momentum of 20 GeV/c, the probability of misidentifying a hadron as an electron is below 10 −2 for an electron detection efficiency of 98%–99%, and it is 1 . 6⋅10 −4 for electron detection efficiency of 90%. This performance surpasses the electron/hadron rejection power of all known TRDs by an order of magnitude for the same detector length.
AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .
Fission power systems have demonstrated higher thermal energy density per unit mass than chemical systems. High mass specific energy density offers advantages in space thermal propulsion applications. In the 1960s, nuclear thermal propulsion (NTP) development included the ROVER/NERVA program, in which full-scale prototype reactors were tested on the ground using hydrogen as the reactor coolant and propellant. NTP systems are being revisited, with expectations of improved performance resulting from improved fuel materials, allowing propellant temperatures near 2,800 K and over 20 thermal propulsion cycles. An apparatus has been developed to test NTP fuel materials in a research reactor at temperature and in a radiation environment typical of the NTP application. Here, this paper presents the design constraints, preliminary scoping thermal analysis, and basic thermal qualification testing for the out-of-pile experiment set apparatus, or OUTSET.
The evaluation of hot channel factor (HCF) is of great significance to the quantification of safety margins for reactor designs. In this paper, HCFs for a sodium-cooled fast reactor (SFR) are evaluated with the Simulation-based High-efficiency Advanced Reactor Prototyping (SHARP) toolkit, which is developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign of DOE for multi-physics reactor performance and safety simulations. The high-fidelity neutronics and thermal hydraulics solvers PROTEUS and Nek5000 in the SHARP toolkit are coupled to perform the multi-physics simulations for HCF evaluation. The HCFs induced by cladding manufacturing tolerance, fissile content mal-distribution, wire orientation and uncertainties on the cladding, coolant, and fuel properties are evaluated for a reference core SFR design (AFR-100). The HCFs calculated with the SHARP toolkit are compared to legacy HCFs for similar reactor types. The comparison demonstrates the reduction or elimination of modeling uncertainties in the calculation of HCFs using high fidelity advanced modeling and simulation tools without the need of expensive experiments. Moreover, the reduction of the uncertainties on HCFs evaluation allows an increase in nominal parameters and safety margin, which in turn improves the economic competitiveness of the SFR.