Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Precision timing measurement of phototube pulses using a flash analog-to-digital converter

We present the timing characteristics of the flash ADC readout of the GlueX forward calorimeter, which depends on precise measurement of arrival time of pulses from FEU 84-3 photomultiplier tubes to suppress backgrounds. The tests presented were performed using two different 250 MHz prototype flash ADC devices, one with eight-bit and one with 12-bit sampling depth. All measured time resolutions were better than 1 ns, independent of signal size, which is the design goal for the GlueX forward calorimeter. For pulses with an amplitude of 100 mV the timing resolution is 0.57±0.18 ns, while for 500 mV pulses it is 0.24±0.08 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision photon flux determination for photon tagging experiments

The Jefferson Laboratory PrimEx Collaboration has developed and implemented a method to control the tagged photon flux in photoproduction experiments at the 1% level over the photon energy range from 4.9 to 5.5 GeV. This method has been successfully implemented in a high precision measurement of the neutral pion lifetime. Here, we outline the experimental equipment and the analysis techniques used to accomplish this. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and a new method for post-bremsstrahlung electron counting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceleration of matrix element computations for precision measurements

The matrix element technique provides a superior statistical sensitivity for precision measurements of important parameters at hadron colliders, such as the mass of the top quark or the cross-section for the production of Higgs bosons. The main practical limitation of the technique is its high computational demand. Using the example of the top quark mass, we present two approaches to reduce the computation time of the technique by a factor of 90. First, we utilize low-discrepancy sequences for numerical Monte Carlo integration in conjunction with a dedicated estimator of numerical uncertainty, a novelty in the context of the matrix element technique. We then utilize a new approach that factorizes the overall jet energy scale from the matrix element computation, a novelty in the context of top quark mass measurements. The utilization of low-discrepancy sequences is of particular general interest, as it is universally applicable to Monte Carlo integration, and independent of the computing environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simulation model of front-end electronics for high-precision timing measurements with low-gain avalanche detectors

Here, we report simulation results of a study aiming to optimize parameters of a detector that uses low-gain avalanche detectors (LGAD) for high-precision timing measurements. The detector is assumed to be composed of a 50μm LGAD sensor coupled to front-end readout electronics which is used to measure the time of arrival of minimum ionizing particles. The simulation includes modeling of signal fluctuations in the LGAD sensor, variations of the analog bandwidth and signal-to-noise ratio (SNR) of the front-end electronics, time bin quantization, and radiation damage of the LGAD sensors. Two approaches to measure the timestamp are considered: leading edge and constant fraction. Simulated LGAD pulses before irradiation, and after irradiation with neutron fluences of 5×10 14 n/cm 2 and 1×10 15 n/cm 2 , are studied. The time resolution for a 50μm LGADs was found to be 35 ps for front-end electronics bandwidths larger than 350 MHz and SNRs larger than 30. The time resolution at SNR of 30 for fluences of 5×10 14 n/cm 2 and 1×10 15 n/cm 2 were found to be 31 ps and 37 ps, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high precision calibration of the nonlinear energy response at Daya Bay

A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment’s antineutrino detectors is observed. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by γ calibration points from deployed and naturally occurring radioactive sources, the β spectrum from 12 B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. With this beind said, less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurements of Long-Baseline Neutrino Oscillation at LBNF

In a long-baseline neutrino oscillation experiment, the primary physics objectives are to determine the neutrino mass hierarchy, to determine the octant of the neutrino mixing angle θ 23 , to search for CP violation in neutrino oscillation, and to precisely measure the size of any CP-violating effect that is discovered. This presentation provides a brief introduction to these measurements and reports on efforts to optimize the design of a long-baseline neutrino oscillation experiment, the status of LBNE, and the transition to an international collaboration at LBNF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision covariant one-boson-exchange potentials for np scattering below 350 MeV

All realistic potential models for the two-nucleon interaction are to some extent based on boson exchange. However, in order to achieve an essentially perfect fit to the scattering data, characterized by a chi2/Ndata~ 1, previous potentials have abandoned a pure one boson-exchange mechanism (OBE). Using a covariant theory, we have found a true OBE potential that fits the 2006 world np data below 350 MeV with a chi2/Ndata = 1.00 for 3612 data. Our potential has fewer adjustable parameters than previous high precision potentials, and also reproduces the experimental triton binding energy without introducing additional irreducible three-nucleon forces.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Study of Excited State Effects in Nucleon Matrix Elements

We present a dedicated precision analysis of the influence of excited states on the calculation of several nucleon matrix elements. This calculation is performed at fixed values of the lattice spacing, volume and pion mass that are typical of contemporary lattice computations. We focus on the nucleon axial charge, g{sub A}, for which we use 7,500 measurements, and on the average momentum of the unpolarized isovector parton distribution, x{sub u-d}, for which we use 23,000 measurements. All computations are done employing N{sub f}=2+1+1 maximally-twisted-mass Wilson fermions and non-perturbatively calculated renormalization factors. We find that excited state effects are negligible for g{sub A} and lead to a O(10%) downward shift for x{sub u-d}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Measurements of Beam Spin Asymmetries in Semi-Inclusive π 0 production

We present studies of single-spin asymmetries for neutral pion electroproduction in semi-inclusive deep-inelastic scattering of 5.776 GeV polarized electrons from an unpolarized hydrogen target, using the CEBAF Large Acceptance Spectrometer (CLAS) at the Thomas Jefferson National Accelerator Facility. A substantial sin Φ h amplitude has been measured in the distribution of the cross section asymmetry as a function of the azimuthal angle Φ h of the produced neutral pion. The dependence of this amplitude on Bjorken x and on the pion transverse momentum is extracted with significantly higher precision than previous data and is compared to model calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurement of the ratio of the charged kaon leptonic decay rates

A precision measurement of the ratio RK of the rates of kaon leptonic decays K+- --> e nu and K+- --> mu nu with the full data sample collected by the NA62 experiment at CERN in 2007-2008 is reported. The result, obtained by analysing ~150000 reconstructed K+- --> e nu candidates with 11% background contamination, is RK = (2.488+-0.010)*10^{-5}, in agreement with the Standard Model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision measurement of Compton scattering in the 5 GeV region

The cross section of atomic electron Compton scattering $\gamma + e \rightarrow \gamma^\prime + e^\prime $ was measured in the 4.40--5.475 GeV photon beam energy region by the {\em PrimEx} collaboration at Jefferson Lab with an accuracy of 2\% and less. The results are consistent with theoretical predictions that include next-to-leading order radiative corrections. The measurements provide the first high precision test of this elementary QED process at beam energies greater than 0.1 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the NΛ–NΣ coupled system with high precision correlation techniques at the LHC

The interaction of Λ and Σ hyperons (Y) with nucleons (N) is strongly influenced by the coupled-channel dynamics. Due to the small mass difference of the NΛ and NΣ systems, the sizable coupling strength of the NΣ↔NΛ processes constitutes a crucial element in the determination of the NΛ interaction. In this letter we present the most precise measurements on the interaction of pΛ pairs, from zero relative momentum up to the opening of the NΣ channel. The correlation function in the relative momentum space for pΛ ⊕$\bar{p}$$\bar{Λ}$ pairs measured in high-multiplicity triggered pp collisions at $\sqrt{s}$=13 TeV at the LHC is reported. The opening of the inelastic NΣ channels is visible in the extracted correlation function as a cusp-like structure occurring at relative momentum k*=289 MeV/c. This represents the first direct experimental observation of the NΣ↔NΛ coupled channel in the pΛ system. The correlation function is compared with recent chiral effective field theory calculations, based on different strengths of the NΣ↔NΛ transition potential. A weaker coupling, as possibly supported by the present measurement, would require a more repulsive three-body NNΛ interaction for a proper description of the Λ in-medium properties, which has implications on the nuclear equation of state and for the presence of hyperons inside neutron stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shape polarization in the tin isotopes near N = 60 from precision g-factor measurements on short-lived 11/2 - isomers

The g factors of 11/2 - isomers in semimagic 109 Sn and 111 Sn (isomeric lifetimes $\tau$ = 2.9(3) ns and $\tau$ = 14.4(7) ns, respectively) were measured by an extension of the Time Differential Perturbed Angular Distribution technique, which uses LaBr3 detectors and the hyperfine fields of a gadolinium host to achieve precise measurements in a new regime of short-lived isomers. The results, g(11/2 - ; 109 Sn) = -0.186(8) and g(11/2 - ; 111 Sn) = -0.214(4), are significantly lower in magnitude than those of the 11/2 - isomers in the heavier isotopes and depart from the value expected for a near pure neutron h 11/2 configuration. Broken-symmetry density functional theory calculations applied to the sequence of 11/2 - states reproduce the magnitude and location of this deviation. The g(11/2 - ) values are affected by shape core polarization; the odd Oh 11/2 neutron couples to J π = 2 + , 4 + , 6 + ... configurations in the weakly-deformed effective core, causing a decrease in the g-factor magnitudes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision tests of fundamental physics with η and η ' mesons

Decays of the neutral and long-lived $\eta$ and $\eta'$ mesons provide a unique, flavor-conserving laboratory to test low-energy Quantum Chromodynamics and search for new physics beyond the Standard Model. They have drawn world-wide attention in recent years and have inspired broad experimental programs in different high-intensity-frontier centers. Additionally, new experimental data will offer critical inputs to precisely determine the light quark mass ratios, $\eta$-$\eta'$ mixing parameters, and hadronic contributions to the anomalous magnetic moment of the muon. At the same time, it will provide a sensitive probe to test potential new physics. This includes searches for hidden photons, light Higgs scalars, and axion-like particles that are complementary to worldwide efforts to detect new light particles below the GeV mass scale, as well as tests of discrete symmetry violation. In this review, we give an update on theoretical developments, discuss the experimental opportunities, and identify future research needed in this field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ex vivo testing of immune responses in precision-cut lung slices

The aim of this study was the establishment of precision-cut lung slices (PCLS) as a suitable ex vivo alternative approach to animal experiments for investigation of immunomodulatory effects. For this purpose we characterized the changes of cytokine production and the expression of cell surface markers after incubation of PCLS with immunoactive substances lipopolysaccharide (LPS), macrophage-activating lipopeptide-2 (MALP-2), interferon {gamma} (IFN{gamma}), and dexamethasone. Viability of PCLS from wild-type and CD11c-enhanced yellow fluorescent protein (CD11-EYFP)-transgenic mice was controlled by measurement of lactate dehydrogenase (LDH) enzyme activity and live/dead fluorescence staining using confocal microscopy. Cytokines and chemokines were detected with Luminex technology and ELISA. Antigen presenting cell (APC) markers were investigated in living mouse PCLS in situ using confocal microscopy. LPS triggered profound pro-inflammatory effects in PCLS. Dexamethasone prevented LPS-induced production of cytokines/chemokines such as interleukin (IL)-5, IL-1{alpha}, TNF{alpha}, IL-12(p40), and RANTES in PCLS. Surface expression of MHC class II, CD40, and CD11c, but not CD86 was present in APCs of naive PCLS. Incubation with LPS enhanced specifically the expression of MHC class II on diverse cells. MALP-2 only failed to alter cytokine or chemokine levels, but was highly effective in combination with IFN{gamma} resulting in increased levels of TNF{alpha}, IL-12(p40), RANTES, and IL-1{alpha}. PCLS showed characteristic responses to typical pro-inflammatory stimuli and may thus provide a suitable ex vivo technique to predict the immunomodulatory potency of inhaled substances.

60 APPLIED LIFE SCIENCES↗