Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Description of the Prometheus Program Alternator/Thruster Integration Laboratory (ATIL)

The Project Prometheus Alternator Electric Thruster Integration Laboratory's (ATIL) primary two objectives are to obtain test data to influence the power conversion and electric propulsion systems design, and to assist in developing the primary power quality specifications prior to system Preliminary Design Review (PDR). ATIL is being developed in stages or configurations of increasing fidelity and complexity in order to support the various phases of the Prometheus program. ATIL provides a timely insight of the electrical interactions between a representative Permanent Magnet Generator, its associated control schemes, realistic electric system loads, and an operating electric propulsion thruster. The ATIL main elements are an electrically driven 100 kWe Alternator Test Unit (ATU), an alternator controller using parasitic loads, and a thruster Power Processing Unit (PPU) breadboard. This paper describes the ATIL components, its development approach, preliminary integration test results, and current status.

Baez, Anastacio N.↗

Dust Tolerant EVA-Compatible Connectors

The objectives of this project are to develop connectors (quick disconnects and umbilical systems) that can be repetitively and reliably mated and de-mated during Lunar surface extra-vehicular activities. These standardized interfaces will be required for structural integrity and commodities transfer between linked surface elements. QD's fittings are needed for EVA spacesuit Primary Life Support Systems as well as liquid cooled garment circulation and suit heat rejection. Umbilical electro-mechanical systems (connectors) are needed between discrete surface systems for transfer of air, power, fluid (water), and data must be capable of being operated by extra vehicular astronaut crew members and/or robotic assistants. There exists an urgent need to prevent electro-statically charged dust and debris from clogging and degrading the interface seals and causing leakage and spills of hazardous commodities, contaminating the flowstream, and degrading the mechanisms needed for umbilical connection. Other challenges include modularity, standardization, autonomous operation, and lifetime sealing issues.

Mueller, Robert P.↗

The Feasibility of Moving PMU Data in the Future Power Grid

The power grid is a complex network connecting electricity providers with their consumers. With an increasing consumer base requiring more resources and the requirement to integrate significant renewable sources, maintaining the network requires new and innovative management solutions. To manage this complexity and provide precise, real-time views of the grid, Phasor Measurement Units (PMUs) are undergoing widespread deployment. These units provide measurements as often as 60 times per second, with an accurate time identifier attached to each reading, enabling real-time monitoring of the network. However, this new capability generates much more data than the current infrastructure is designed to handle. With the expectation that there will eventually be tens of thousands of PMUs monitoring the transmission lines, the power community is looking towards accumulating multiple terabytes of data per day - several orders of magnitude beyond current data acquisition rates. This has led to questions being raised in the power community about whether or not a significant research effort is required to effectively transfer the volume of information generated by these new data streams. This paper answers that question by comparing a worst-case data generation scenario with several alternative networking protocols and historical trends in protocol advancement. Based on this analysis we are able to conclude that transferring the information between the PMUs and the resulting data repositories is feasible. We recognize that there are issues beyond transferring the data that need to be addressed such as effective access to historical data, data transfer latency, cyber security, and data analysis. There is also an extensive engineering trade-off that the power companies will need to make to decide the best mix of networking protocols for their particular PMU deployments, since that requires significant assumptions about proprietary information including deployment cost, deployment schedules, PMU locations, and available resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ADMS Test Bed Updates

This webinar will present results from a joint project with utility partner Xcel Energy in which we evaluated their ADMS application for volt-var optimization using different levels of model quality. We were able to help Xcel Energy understand the trade-offs of telemetry measurements and model quality when managing a feeder's voltage profile to maximize energy conservation. We simulated scenarios with varying levels of model quality and measurement density to evaluate Xcel's options for best using its ADMS. The results help Xcel and other utilities understand how network data affects voltage management as grid operations see continued growth in solar photovoltaic (PV) systems and electric vehicles (EVs).

ADMS↗

DETAIL Component Scaling and Methodology Comparison

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is a research facility in development. Its aim is to emulate the daily interactions among power production industry systems and receive real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (DSS) and Hierarchical Two-Tiered Scaling (H2TS) (methodologies that enable systems to scale and project or extrapolate data sets to desired environments while conserving the observed behavior based on first principles) were applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System (TEDS) facility and solid-oxide electrolysis cell in the High Temperature Hydrogen Electrolysis (HTHE) facility. Both thermocline and electrolysis cell systems were successfully scaled, and test cases were conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facilities. The research results represented a case for the thermocline system that required signals to be accelerated without altering the stored energy. To enhance the quality of the accelerated data, error propagation analyses were conducted on DSS post-processing terms to determine the consequences of raw-data-associated errors.

08 HYDROGEN↗

Preliminary Development of a Nuclide Inventory Code for HTGR

Nuclide inventory calculation for a reactor core is the basis of radiation protection, shielding design and radioactive environmental impact assessment of the power plant. HTR-PM (high-temperature gas-cooled reactor pebble-bed module) under construction in China is one of the candidates for Gen-IV advanced nuclear power system.1 In the design stage of HTR-PM, KORIGEN has been utilized in the inventory calculation.2 However, the current version of KORIGEN was developed several decades ago. In order to improve the design capability of the analysis code package for HTR-PM, a new computer code for nuclide inventory calculation called NUIT (Nuclide Inventory Tool) is being developed based on the DEPTH3 code. The NUIT code tries to utilize accurate and efficient burnup solvers, incorporate well-validated and most recent nuclear data libraries, and provide user-friendly IO interface. This paper presents the preliminary work in the development of NUIT.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

Modeling and Detection of Future Cyber-Enabled DSM Data Attacks

Demand-Side Management (DSM) is an essential tool to ensure power system reliability and stability. In future smart grids, certain portions of a customer’s load usage could be under the automatic control of a cyber-enabled DSM program, which selectively schedules loads as a function of electricity prices to improve power balance and grid stability. In this scenario, the security of DSM cyberinfrastructure will be critical as advanced metering infrastructure and communication systems are susceptible to cyber-attacks. Such attacks, in the form of false data injections, can manipulate customer load profiles and cause metering chaos and energy losses in the grid. The feedback mechanism between load management on the consumer side and dynamic price schemes employed by independent system operators can further exacerbate attacks. To study how this feedback mechanism may worsen attacks in future cyber-enabled DSM programs, we propose a novel mathematical framework for (i) modeling the nonlinear relationship between load management and real-time pricing, (ii) simulating residential load data and prices, (iii) creating cyber-attacks, and (iv) detecting said attacks. In this framework, we first develop time-series forecasts to model load demand and use them as inputs to an elasticity model for the price-demand relationship in the DSM loop. This work then investigates the behavior of such a feedback loop under intentional cyber-attacks. We simulate and examine load-price data under different DSM-participation levels with three types of random additive attacks: ramp, sudden, and point attacks. We conduct two investigations for the detection of DSM attacks. The first studies a supervised learning approach, with various classification models, and the second studies the performance of parametric and nonparametric change point detectors. Results conclude that higher amounts of DSM participation can exacerbate ramp and sudden attacks leading to better detection of such attacks, especially with supervised learning classifiers. We also find that nonparametric detection outperforms parametric for smaller user pools, and random point attacks are the hardest to detect with any method.

97 MATHEMATICS AND COMPUTING↗

Error analysis in the measurement of average power with application to switching controllers

Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.

Maisel, J. E.↗

System Study: Emergency Power System 1998–2018

This report presents an unreliability evaluation of the emergency power system (EPS) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the EPS results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: Emergency Power System 1998-2020

This report presents an unreliability evaluation of the emergency power system (EPS) at 104 U.S. commercial nuclear power plants. Demand, run hours, and failure data from 1998 through 2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. Statistically significant decreasing trends were identified in the industry-wide estimates of EPS system start-only mission as well as EPS system unreliability (8-hour mission).

99 GENERAL AND MISCELLANEOUS↗

Steel Creek, Pen Branch, and D-Area Watershed Stream Gauging Stations

A network of stream gauging systems were installed in the Steel Creek, Pen Branch, D-Area Discharge Canal, and the D006 Stream in support of the groundwater modeling efforts for the P-Area Groundwater Operable Unit (OU); Chemical, Metals, and Pesticides (CMP) Pits OU; and the D-Area Watershed, respectively. Each location is monitored by a MACE Floseries3 FloPro data logger and a MACE doppler ultrasonic area/velocity sensor. Each stream gauging system is powered by an internal 12-volt battery supplied by a solar panel with a trickle charger. Information collected by each data logger is logged internally and telecommunicated via a cellular network to an online server for real time analysis and monitoring. The MACE doppler ultrasonic area/velocity sensor can measure stream depth and velocities to give output values of flow rates, total flow, net flow, and volumes. The water depth is measured by a ceramic pressure transducer located on the top of the sensor. The velocity is measured by a continuous wave doppler sensor to give an average velocity across the whole stream profile. This report discusses the equipment and methods used to install continuous stream gauging stations and provides a summary of data collected through FY2025.

54 ENVIRONMENTAL SCIENCES↗

SystemBurn: Principles of Design and Operation, Release 2.0

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 2.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 3.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

Benchmark↗

Stratoscope 2 integrating television camera

The development, construction, test and delivery of an integrating television camera for use as the primary data sensor on Flight 9 of Stratoscope 2 is described. The system block diagrams are presented along with the performance data, and definition of the interface of the telescope with the power, telemetry, and communication system.

Source record↗

Analysis of Trade-Off Between Power Saving and Response Time in Disk Storage Systems

It is anticipated that in the near future disk storage systems will surpass application servers and will become the primary consumer of power in the data centers. Shutting down of inactive disks is one of the more widespread solutions to save power consumption of disk systems. This solution involves spinning down or completely shutting off disks that exhibit long periods of inactivity and placing them in standby mode. A file request from a disk in standby mode will incur an I/O cost penalty as it takes time to spin up the disk before it can serve the file. In this paper, we address the problem of designing and implementing file allocation strategies on disk storage that save energy while meeting performance requirements of file retrievals. We present an algorithm for solving this problem with guaranteed bounds from the optimal solution. Our algorithm runs in O(nlogn) time where n is the number of files allocated. Detailed simulation results and experiments with real life workloads are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Big Data For Operation and Maintenance Cost Reduction

The purpose of this research is to develop a first-of-a-kind framework for integrating Big Data capability into the daily activities of our current fleet of nuclear power plants. Big Data is traditionally defined as data sets with high volume, velocity, and heterogeneity, and the existing Big Data analytics capabilities are now widely popular in fields such as finance, weather, e-commerce, healthcare and sports. In the nuclear industry, while the volume and velocity of data may present computational challenges for existing analytics capabilities, data heterogeneity are seen to present the major challenge. This research project mainly focuses on incorporating the wide range of data heterogeneities in nuclear power plants into an integrated Big Data Analytics capability. The primary end-product of this project is a Big Data framework that is capable of dealing with the large volume and heterogeneity of the data found in nuclear power plants to extract timely and valuable information on equipment performance. The framework can generate system insights that are actionable relations between measurable impacts and the corresponding maintenance action plans and enable optimization of plant operation and maintenance based on the extracted information. The developed framework is capable of handling heterogeneous data including both image data and time-series sensor data. Specifically, this developed framework includes the following components. The first component is an overarching maintenance ontology which includes system insights required by maintenance optimization. The maintenance ontology interacts with other components in the developed framework. The second component handles Piping & Instrumentation Diagram (P&ID) data. It can be used to extract system components and their relations automatically from the P&IDs. This extracted information is stored in the first component, i.e., maintenance ontology, and is also used as input to the third component, i.e., a tool for generating the fault tree for the corresponding system. The generated fault tree in turn is stored in the ontology for assessing risk that is used as a criterion in maintenance policy optimization. The fourth component is a tool for inferring the parameters in the Markov degradation model for a nuclear system. It uses basic information from the ontology. The fifth component is a tool for assessing the degradation level using sensor measurement data, for example, pressure, flowrate. This tool can be used for determining corrective maintenance actions. The results obtained from components four and five are returned to the ontology. The sixth component of the framework is a tool for optimizing the maintenance policy for a nuclear system of interest. It takes certain basic information from the ontology, e.g., costs of maintenance actions and system failures, as input, and returns the optimal maintenance policy to the ontology. This tool can be used for determining predictive maintenance actions. A set of experiments have also been conducted to verify the algorithms developed in this project for nuclear system degradation monitoring. The experiments are based on four solenoid valves, similar to the ones used in nuclear power plants. The analyses based on the experimental data using two algorithms, i.e., the Randomized Window Decomposition (RWD) algorithm and the particle filtering algorithm, and the results are introduced in the report. The Big Data framework developed in this project can be used as a support tool in daily activities of plant operation and maintenance and will reduce current costs while maintaining or improving safety levels. Overall, the project will not only benefit existing reactors, however it will open new frontiers to realize the long overdue value of Big Data Analytics in the nuclear sphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗