High resolution identification and quantification of diffuse deep groundwater discharge in mountain rivers using continuous boat-mounted helium measurements

Discharge of deeply sourced groundwater to streams is difficult to locate and quantify, particularly where both discrete and diffuse discharge points exist, but diffuse discharge is one of the primary controls on solute budgets in mountainous watersheds. The noble gas helium is a unique identifier of deep groundwater discharge because groundwater with long residence times is commonly enriched in helium. In this study, a portable mass spectrometer was used to measure longitudinal variation in dissolved helium concentrations in two mountainous rivers at high spatial resolution not feasible with traditional sampling techniques. Helium profiles were then simulated using a mass-balance model to quantify longitudinal variation in groundwater discharge to the receiving rivers. Results indicate helium concentrations were enriched by multiple orders of magnitude above atmospheric equilibrium in both rivers and that this persisted for up to 18 km below observed pulse inputs in the Colorado River. Helium mass-balance models match observed longitudinal patterns with the exception of sharp initial increases in helium observed in the rivers. Increased longitudinal groundwater discharge rates correspond to mapped geologic structures in both watersheds that likely transport deep geothermal water. Models show variable sensitivity to spatial assignment of input variables representing the groundwater source, illustrating the importance of collecting data from discrete groundwater discharges where possible. The methodology shows promise for field experiments designed to assess air–water exchange rates and to quantify total groundwater discharge from a combination of discrete and diffuse sources.

Deep groundwater↗

Flash-X: A multiphysics simulation software instrument

Flash-X is a highly composable multiphysics software system that can be used to simulate physical phenomena in several scientific domains. It derives some of its solvers from FLASH, which was first released in 2000. Flash-X has a new framework that relies on abstractions and asynchronous communications for performance portability across a range of increasingly heterogeneous hardware platforms. Flash-X is meant primarily for solving Eulerian formulations of applications with compressible and/or incompressible reactive flows. It also has a built-in, versatile Lagrangian framework that can be used in many different ways, including implementing tracers, particle-in-cell simulations, and immersed boundary methods.

97 MATHEMATICS AND COMPUTING↗

Spray: Sparse Reductions of Arrays in OPEN MP

We present SPRAY, an open-source header-only C++ library for sparse reductions of arrays. SPRAY is meant for applications in which a large array is collaboratively updated by multiple threads using an associative and commutative operation such as +=. Especially when each thread accesses only parts of the array, SPRAY can perform significantly better than OPENMP's built-in reduction clause or atomic updates, while also using less memory than the former. SPRAY provides both an easy-to-use interface that can serve as a drop-in replacement for OPENMP reductions and a selection of reducer objects that accumulate the final result in different thread-safe ways. We demonstrate SPRAY through multiple test cases including the LULESH shock hydrodynamics code and a transpose-matrix-vector multiplication for sparse matrices stored in CSR format. SPRAY reductions outperform built-in OPENMP reductions consistently, in some cases improving run time and memory overhead by 20X, and even beating domain-specific approaches such as Intel MKI, by over 2X in some cases. Furthermore, SPRAY reductions have a minimal impact on the code base, requiring only a few lines of source code changes. Once in place, SPRAY reduction schemes can be switched easily, allowing performance portability and tuning opportunities by separating performance-critical implementation details from application code.

OpenMP↗

Trilinos: Enabling Scientific Computing across Diverse Hardware Architectures at Scale

Trilinos is a community-developed, open-source software framework that facilitates building large-scale, complex, multiscale, multiphysics simulation code bases for scientific and engineering problems. Since the Trilinos framework has undergone substantial changes to support new applications and new hardware architectures, this document is an update to “An Overview of the Trilinos project” by Heroux et al. (ACM Transactions on Mathematical Software, 31(3):397–423, 2005). It describes the design of Trilinos, introduces its new organization in product areas, and highlights established and new features available in Trilinos. Particular focus is put on the modernized software stack based on the Kokkos ecosystem to deliver performance portability across heterogeneous hardware architectures. This article also outlines the organization of the Trilinos community and the contribution model to help onboard interested users and contributors.

Heterogeneous Hardware Architectures↗

MAGMA: Enabling exascale performance with accelerated BLAS and LAPACK for diverse GPU architectures

MAGMA (Matrix Algebra for GPU and Multicore Architectures) is a pivotal open-source library in the landscape of GPU-enabled dense and sparse linear algebra computations. With a repertoire of approximately 750 numerical routines across four precisions, MAGMA is deeply ingrained in the DOE software stack, playing a crucial role in high-performance computing. Notable projects such as ExaConstit, HiOP, MARBL, and STRUMPACK, among others, directly harness the capabilities of MAGMA. In addition, the MAGMA development team has been acknowledged multiple times for contributing to the vendors’ numerical software stacks. Looking back over the time of the Exascale Computing Project (ECP), we highlight how MAGMA has adapted to recent changes in modern HPC systems, especially the growing gap between CPU and GPU compute capabilities, as well as the introduction of low precision arithmetic in modern GPUs. We also describe MAGMA’s direct impact on several ECP projects. Maintaining portable performance across NVIDIA and AMD GPUs, and with current efforts toward supporting Intel GPUs, MAGMA ensures its adaptability and relevance in the ever-evolving landscape of GPU architectures.

97 MATHEMATICS AND COMPUTING↗

kokkos-fft: A shared-memory FFT for the Kokkos ecosystem

kokkos-fft provides a unified, performance-portable interface for Fast Fourier Transforms (FFTs) within the Kokkos ecosystem (C. Trott et al., 2021). It seamlessly integrates with leading local FFT libraries including FFTW, cuFFT, rocFFT, and oneMKL. Designed for simplicity and efficiency, kokkos-fft offers a user experience akin to numpy.fft for in-place and out-of-place transforms, while leveraging the raw speed of vendor-optimized libraries. A demonstration solving 2D Hasegawa-Wakatani turbulence with the Fourier spectral method illustrates how kokkos-fft can deliver significant speedups over Python-based alternatives without drastically increasing code complexity, empowering researchers to perform high-performance FFTs simply and effectively.

97 MATHEMATICS AND COMPUTING↗

Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector. One of the difficult technical challenges is to discriminate the chlorine-based chemical agents. Especially, CN, CNB, CNS and CG have similar chemical compositions to make it hard to discriminate them with a higher confidence. Current identification algorithms for PINS systems with 252-Cf sources have been improved and updated continuously as more field data became available, and new algorithms was studied to complement the current algorithms by adopting the Gaussian Bayes classifier. These new algorithms were intended to be applied to a subset of chlorine-based chemical agents, and their main goal is discriminate CN, CNB, CNS and CG with their ratios of the chlorine neutron inelastic 1763keV peak to the chlorine thermal neutron capture 1959keV peak, which is referred to as the “Cl i/c” or “clic” ratio in this study. The Cl i/c ratios were assumed to follow Gaussian distributions with the means and the standard deviations unique to their corresponding chemical agents. The prior probabilities of these four chemical agents were optimized with a collection of field data to achieve the best performance in terms of precision or positive predictive value (PPV). Finally, their posterior probabilities as functions of the Cl i/c ratio were implemented in the current version of PINS analysis software in order to be tested with more field data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

bolt: A GPU-Accelerated Solver for Marginally Collisional Kinetic Physics Using a High- Resolution Constrained Transport Scheme

Collisionless and marginally collisional plasmas are very expensive to simulate due to high dimensionality and large scale separations, especially in global problems with additional length scales. bolt addresses this challenge by achieving high performance on GPUs using the arrayfire performance portability library. We have demonstrated accuracy on a range of test problems, and the bolt code paper is currently in preparation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next Generation Chemical Agent Detection Architecture [Poster]

Sandia National Labs (SNL)-designed, portable chemical warfare agent (CWA) detection systems consist of three-stages: collection, separation, and detection. We use microfabrication technologies to miniaturize these stages and to reduce the overall size, weight, power, and (potentially) cost of the final system. Our newest system consists of a multi-dimensional separation stage and an miniature ion mobility spectrometer (IMS) detector for unprecedented system sensitivity, selectivity, and depth of target list.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood

Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.

36 MATERIALS SCIENCE↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

ExINP-ENA Ice-Nucleating Particle Concentrations - PINE

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) observatory on Graciosa Island, Azores (39.0916° N, 28.0257° W). Our INP data were generated using a combination of online instruments, the Portable Ice Nucleation Experiment chamber (PINE), and an offline assay instrument, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT), for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores).

54 ENVIRONMENTAL SCIENCES↗

Using SpF to Achieve Petascale for Legacy Pseudospectral Applications

Pseudospectral (PS) methods possess a number of characteristics (e.g., efficiency, accuracy, natural boundary conditions) that are extremely desirable for dynamo models. Unfortunately, dynamo models based upon PS methods face a number of daunting challenges, which include exposing additional parallelism, leveraging hardware accelerators, exploiting hybrid parallelism, and improving the scalability of global memory transposes. Although these issues are a concern for most models, solutions for PS methods tend to require far more pervasive changes to underlying data and control structures. Further, improvements in performance in one model are difficult to transfer to other models, resulting in significant duplication of effort across the research community. We have developed an extensible software framework for pseudospectral methods called SpF that is intended to enable extreme scalability and optimal performance. Highlevel abstractions provided by SpF unburden applications of the responsibility of managing domain decomposition and load balance while reducing the changes in code required to adapt to new computing architectures. The key design concept in SpF is that each phase of the numerical calculation is partitioned into disjoint numerical kernels that can be performed entirely inprocessor. The granularity of domain decomposition provided by SpF is only constrained by the datalocality requirements of these kernels. SpF builds on top of optimized vendor libraries for common numerical operations such as transforms, matrix solvers, etc., but can also be configured to use open source alternatives for portability. SpF includes several alternative schemes for global data redistribution and is expected to serve as an ideal testbed for further research into optimal approaches for different network architectures. In this presentation, we will describe our experience in porting legacy pseudospectral models, MoSST and DYNAMO, to use SpF as well as present preliminary performance results provided by the improved scalability.

DYNAMO↗

Monolithic Trace-Contaminant Sorbents Fabricated from 3D-Printed Polymer Precursors

The current trace-contaminant (TC) removal technology for use in Extravehicular Activities (EVAs) involves the use of a packed bed of acid-impregnated granular charcoal, which is difficult to regenerate. In this paper, results are presented on the development of vacuum-regenerable TC sorbents for use in the Portable Life Support System (PLSS). The sorbents are derived from 3D-printed polymer monoliths (e.g., honeycomb structures), which are then carbonized and activated in order to develop porosity, and also to enhance the TC-sorption capacity. Results are presented on the following aspects of carbon-sorbent development: (1) precursor selection; (2) monolith fabrication; (3) shape retention and strength; (4) carbon surface and porosity characterization; (5) TC-sorption capacity and vacuum-regeneration; (6) pressure drop; and (7) sub-scale sorbent prototype. The use of predominantly microporous monolithic carbon is associated with the following benefits: (a) high TC-sorption capacity; (b) low pressure drop; (c) rapid vacuum (pressure-swing) desorption due to thin monolith walls and low pressure drop; (d) good thermal management (high thermal conductivity and low adsorption/desorption thermal effects associated with physisorption); and (e) good resistance to dusty environments.

Portable Life Support System (PLSS)↗

Ultra-Pure, High Endurance Liquid Bladder with Volume Sensor for Space Applications

The NASA Portable Life Support System (PLSS) for the Exploration Extravehicular Mobility Unit (xEMU) incorporates a Feedwater Supply Assembly (FSA) to store consumable cooling water. The FSA accepts pure water prior to each Extra-Vehicular Activity (EVA), then supplies this water to a membrane evaporator at ambient suit pressure during the eight hour EVA. The FSA must function reliably for hundreds of EVAs over 15 years of service without introducing contamination that may accumulate and foul the membrane. We present a unique design that combines the benefits of a flexible fluoropolymer bladder with the strength and convenience of a rigid tank, providing an ultra-pure, ambient-pressure reservoir with fill-drain cycle life exceeding 3000, internal pressure tolerance exceeding 100 psi, high volumetric efficiency, near-zero dead volume, optical transparency for visual inspection, simplified mounting, and very low mass. We also incorporate a novel volume sensor suitable for both microgravity and arbitrarily accelerated environments and capable of real-time monitoring with accuracy on the order of 2.5% full scale. Analytical predictions are supported by experimental test data from a mature subscale prototype.

PLSS Portable Life Support System FSA Feedwater Su↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗