At least 1,315 records · Page 73

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

The Design of a Multiphase CO2 Turbine Test Facility

As the energy market continues to evolve with increased renewables, such as solar and wind energy, the need to balance energy demand with its availability has become increasingly more challenging. The country’s aggressive decarbonization goals in the upcoming decades will increase renewable energy market penetration, thus exacerbating the disparity between energy demand and renewable resource availability. Long-duration energy storage technologies, such as pumped thermal energy storage (PTES), are potential solutions to this challenge with high potential round-trip efficiency (RTE), no geological or geographical constraints, and low safety risks. The charge mode of a PTES system operates a heat pump cycle, converting input power to thermal energy in hot and cold reservoirs. Fundamentally, heat pumps are commonly used in daily life, but the operating conditions required by high RTE PTES systems are outside the design experience of these systems. The low-pressure side of the cycle for a supercritical CO2 (sCO2) PTES operates just above the vapor-dome and potentially drives the turbine to expand into the dome, resulting in multiphase operation in the rear stages of the turbine. This paper presents the design of the test facility for an advanced multiphase-tolerant sCO2 turbine for the heat pump of a PTES system. Heat rejection and pressure loss estimations for the multiphase sections of the test loop presented unforeseen challenges.

25 ENERGY STORAGE↗

Up-Tower Investigation of Main Bearing Cage Slip and Loads

This paper described the operational conditions of an SRB in the main bearing position of a three-point mount wind turbine drivetrain. A commercial wind turbine was instrumented to measure load characteristics on the outer ring of the bearing, which were used to examine the roller load characteristics qualitatively and the cage slip quantitatively in a range of operational states. Further, a simple analytic model estimated the bearing loads and was used as input conditions to a three-dimensional finite element model. The finite element roller load results were compared to the measurements and contact stresses were also described.

17 WIND ENERGY↗

Investigation of an anomalous flow condition of the Langley pilot model expansion tube

Free-stream flow velocity measurements were made in the Langley pilot model expansion tube during the test flow interval. During this interval, an anomalous dip in pitot pressure occurs for the expansion tube operating conditions employed. Within the test flow interval, the main conclusions reached from comparison of the measured flow velocity, pitot pressure, and tube wall pressure are: the variations which occur in velocity and wall pressure are small compared with the variations in pitot pressure; a corresponding dip in the derived flow density is associated with the dip in pitot pressure; and the value of the average density over the interval, which results from the expansion from the shocked intermediate chamber condition, is approximately one-half of the value that can result from only an isentropic process.

Friesen, W. J.↗

The effect of ambient conditions on carbon monoxide emissions from an idling gas turbine combustor

A test program employing a gas turbine combustor is outlined; the results of which quantize the effects of changes in ambient temperature and humidity on carbon monoxide emissions at simulated idle operating conditions. A comparison of the experimental results with analytical results generated by a kinetic model of the combustion process, and reflecting changing ambient conditions, is given. It is demonstrated that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine at idle, and that the analytical model is reasonably successful in predicting changes.

Subramanian, A. K.↗

A 13000-hour test of a mercury hollow cathode

A mercury-fed hollow cathode was tested for 12,979 hours in a bell jar at SERT 2 neutralizer operating conditions. The net electron current drawn to a collector was 0.25 ampere at average collector voltages between 21.8 and 36.7 volts. The mercury flow rate was varied from 5.6 to 30.8 equivalent milliamperes to give stable operation at the desired electrode voltages and currents. Variations with time in the neutralizer discharge characteristics were observed and hypothesized to be related to changes in the cathode orifice dimensions and the availability of electron emissive material. A facility failure caused abnormal test conditions for the last 876 hours and led to the cathode heater failure which concluded the test.

Rawlin, V. K.↗

SiC cladding R&D execution plan

To advance the development of accident-tolerant fuel cladding for light-water reactors, the Advanced Fuels Campaign actively addresses the R&D gap between the specialized technological progress in SiC-based composite materials, led by industrial partners, and the fundamental scientific understanding of material behavior under reactor operating conditions. The laboratory activities are systematically organized based on the Development Strategy document, which outlines critical barriers to the use of SiC composites in nuclear energy applications for the coming decade and beyond. To complement the strategy, this execution plan specifies a detailed year-by-year work package and establishes key milestones for assessing progress in technological advancement. This plan has been formulated in collaboration with principal investigators at national laboratories, stakeholders, and industry partners with the goal of closing technology gaps and readying SiC-based cladding technologies for full-scale commercial testing. The research conducted at the national laboratories is categorized into three primary subjects: (1) addressing challenges associated with the performance of SiC cladding under normal operating environments, (2) identifying the failure limits of SiC cladding under accident conditions, and (3) modeling fuel performance for SiC cladding systems. Comprehensive laboratory activities integrate the development of advanced modeling tools for SiC-based cladding systems with experimental validation via integrated testing of multiphysics phenomena. This document lays out the laboratory plan to support the development of SiC-based technologies, which have the potential for significant operational and safety benefits for the U.S. nuclear industry. This plan aligns with industry developer needs, relevant Nuclear Energy University Programs, and Nuclear Energy Advanced Modeling and Simulation Programs to ensure SiC cladding technologies are matured as efficiently as possible and will be maintained and updated to accommodate the dynamically evolving progress of development, capability needs, and resource availability.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synergistically integrated phosphonated poly(pentafluorostyrene) for fuel cells

Modern electrochemical energy conversion devices require more advanced proton conductors for their broad applications. Phosphonated polymers have been proposed as anhydrous proton conductors for fuel cells. However, the anhydride formation of phosphonic acid functional groups lowers proton conductivity and this prevents the use of phosphonated polymers in fuel cell applications. Here, we report a poly(2,3,5,6-tetrafluorostyrene-4-phosphonic acid) that does not undergo anhydride formation and thus maintains protonic conductivity above 200 °C. We use the phosphonated polymer in fuel cell electrodes with an ion-pair coordinated membrane in a membrane electrode assembly. We find that this synergistically integrated fuel cell reached peak power densities of 1,130 mW cm -2 at 160 °C and 1,740 mW cm -2 at 240 °C under H2/O2 conditions, substantially outperforming polybenzimidazole- and metal phosphate-based fuel cells. Our result indicates a pathway towards using phosphonated polymers in high-performance fuel cells under hot and dry operating conditions.

25 ENERGY STORAGE↗

Triple ionic–electronic conducting oxides for next-generation electrochemical devices

Triple ionic–electronic conductors (TIECs) are materials that can simultaneously transport electronic species alongside two ionic species. The recent emergence of TIECs provides intriguing opportunities to maximize performance in a variety of electrochemical devices, including fuel cells, membrane reactors and electrolysis cells. However, the potential application of these nascent materials is limited by lack of fundamental knowledge of their transport properties and electrocatalytic activity. The goal of this Review is to summarize and analyse the current understanding of TIEC transport and electrochemistry in single-phase materials, including defect formation and conduction mechanisms. In this work, we particularly focus on the discovery criteria (for example, crystal structure and ion electronegativity), design principles (for example, cation and anion substitution chemistry) and operating conditions (for example, atmosphere) of materials that enable deliberate tuning of the conductivity of each charge carrier. Lastly, we identify important areas for further advances, including higher chemical stability, lower operating temperatures and discovery of n-type TIEC materials.

25 ENERGY STORAGE↗

Bifurcation-like transition of divertor conditions induced by X-point radiation in KSTAR L-mode plasmas *

Abstract Density ramps with ion grad B drift directed into lower single null KSTAR L-mode plasmas are associated with a simultaneous and abrupt reduction of the divertor particle flux on both low- and high-field-side targets when the mid-plane line averaged electron density reaches a given level. Target embedded Langmuir probe signals show a clear ‘cliff edge’ behavior similar to that observed in the divertor target electron temperature in DIII-D H-mode plasmas (Eldon et al 2017 Nucl. Fusion 57 066039; McLean et al 2015 J. Nucl. Mater. 463 533–6). The collapse of the particle flux is observed along the whole divertor target area (from private flux region to the far scrape-off layer (SOL)). The critical upstream density of this target flux cliff is invariant under fuel gas throughput modulation. The transition along the cliff occurs in tens of milliseconds. With the cliff, carbon impurities and deuterium neutrals transported through the X-point to the core produce a strong radiation spot near the X-point, seen on bolometric signals, and increase the upstream density. The experimental observations are consistent with time-dependent SOLPS-ITER simulations, which also demonstrate an abrupt transition of the target flux and upstream density with the increase in X-point radiation. The timescale of the cliff predicted by SOLPS-ITER is consistent with the experiment, although, it is influenced by gas throughput or time-dependent numerical methods. In the L-mode phase space of separatrix electron density and temperature, branches are divided based on target temperature, because the latter is strongly coupled to the radiation front and ionization front due to the monotonic characteristic of the parallel electron temperature distribution. Since the H-mode condition operates at a much higher upstream density and electron temperature in phase space, dissipation from sputtered carbon alone leads to the density limit before reaching the X-point radiation condition. This is therefore consistent with the fact that cliffs have never been observed in H-mode KSTAR experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proactive Frequency Stability Scheme via Bayesian Filters and Synchrophasors

Underfrequency (UF) load shedding schemes are traditionally implemented in two ways: One approach is based on manual load shedding, with system operators requesting loads to be shed ahead of anticipated stressful operating conditions. Manual load shedding is usually done through phone calls. The second method is automatic load shedding via underfrequency relays. Using static static settings, these schemes can be designed to operate in stages and drop previously identified loads. The main limitation of traditional load shedding schemes is that they are reactive and leave little room for optimized corrective actions. This work presents a proactive and automatic underfrequency load shedding solution for power systems. Measurements are captured via phasor measurement units (PMUs) at relatively low sampling rates of 30 Hz. These measurements are then processed by particle filters who predict the future state of the system's frequency. Based on these predictions excess load is determined and shed. Comparative case studies are performed in simulated environments. Easy-to-implement models, without hard-to-derive parameters, highlight potential aspects for real-life implementation.

Paramo, Gian↗

Transactive Emergency Power Allocation

The devastating impacts of extreme weather events, many of which are climate-change related, are increasingly evident through the frequency and duration of outages on power grids, especially the distribution systems. One of the major modern-day concerns of utilities is dealing with such extreme supply outages where operators have used rolling blackouts as a contingency plan balance supply and demand while serving critical loads. Such events have significant repercussions social and economic costs. Such blackouts practices are a blunt instrument, depriving customers with low-capacity high-priority loads (i.e. refrigeration, water, telecommunication, etc.) that provide high marginal amenity. Our contribution presented in this work is a transactive emergency allocation mechanism that would provide some minimum level of service to all of the customers while enabling preference-based trading of this initial allocation. This is in contrast to the state-of-art TE mechanisms that allocate resources to customers solely based on their willingness-to-pay. The effectiveness of the proposed mechanism is demonstrated through simulation-based evaluation on a prototypical distribution system experiencing 12-hour scarcity-based emergency event due to extreme operating conditions. Simulation results clearly demonstrate the capability of the proposed transactive emergency allocation mechanism in effectively utilizing the available energy and providing some level of service to all customers to operate their high-priority loads throughout the extreme scarcity event while being economically efficient in allowing trading of allocation based on customer preferences.

transactive energy, power system economics, emerge↗

2022 Annual Emissions Report and Annual Certification of Compliance Required by the Synthetic Minor Operating Permit, Permit Condition Number 19876, Plant 255, Lawrence Livermore National Laboratory

In accordance with the conditions of the Synthetic Minor Operating Permit (SMOP) issued to Lawrence Livermore National Laboratory (LLNL) on August 29, 2002, and revised on February 4, 2009 and February 17, 2015, please find enclosed the 2022 Annual Emissions Report and the Annual Certification of Compliance for LLNL for the period of July 1, 2021 through June 30, 2022. The 2022 Annual Emissions Report identifies the consecutive 12-month rolling totals by month for individual Hazardous Air Pollutants (HAPs), combined HAPs, combined Precursor Organic Compounds (POCs), and Nitrogen Oxides (NOx) emitted from the LLNL site during the months of July 2021 through June 2022.

54 ENVIRONMENTAL SCIENCES↗

Design of a Mach 8.0 axisymmetric nozzle for a hypersonic test facility

An axisymmetric nozzle has been designed to produce test section flow at a Mach number of 8.0 for use in a hypersonic test facility at MSFC. Nominal design conditions used to calculate the viscous correction to the wall contour were selected from the results of a parametric boundary layer investigation so that the widest possible range of satisfactory operating conditions could be obtained. Coordinates for the nozzle are presented in a tabular form suitable for design and manufacturing. The basic analysis techniques have been used to generate results to compare with experimental data from a facility at Langley Research Center. The agreement was reasonably good.

Sims, J. L.↗

Coal desulfurization with iron pentacarbonyl

Coal desulfurization with iron pentacarbonyl treatment under mild conditions removes up to eighty percent of organic sulfur. Preliminary tests on treatment process suggest it may be economical enough to encourage investigation of use for coal desulfurization. With mild operating conditions, process produces environmentally-acceptable clean coal at reasonable cost.

Hsu, G. C.↗

Performance evaluation of a six-axis generalized force-reflecting teleoperator

Work in real-time distributed computation and control has culminated in a prototype force-reflecting telemanipulation system having a dissimilar master (cable-driven, force-reflecting hand controller) and a slave (PUMA 560 robot with custom controller), an extremely high sampling rate (1000 Hz), and a low loop computation delay (5 msec). In a series of experiments with this system and five trained test operators covering over 100 hours of teleoperation, performance was measured in a series of generic and application-driven tasks with and without force feedback, and with control shared between teleoperation and local sensor referenced control. Measurements defining task performance included 100-Hz recording of six-axis force/torque information from the slave manipulator wrist, task completion time, and visual observation of predefined task errors. The task consisted of high precision peg-in-hole insertion, electrical connectors, velcro attach-de-attach, and a twist-lock multi-pin connector. Each task was repeated three times under several operating conditions: normal bilateral telemanipulation, forward position control without force feedback, and shared control. In shared control, orientation was locally servo controlled to comply with applied torques, while translation was under operator control. All performance measures improved as capability was added along a spectrum of capabilities ranging from pure position control through force-reflecting teleoperation and shared control. Performance was optimal for the bare-handed operator.

Hannaford, B.↗

Mars Global Surveyor: Cruising to Mars

The Mars Global Surveyor spacecraft was launched on November 7, 1996, and is now cruising to Mars. While the launch was excellent, and the spacecraft and its science payload are in perfect operating condition, a broken deployment damper on one of the two solar arrays has posed some concern relative to the use of that solar array as a drag surfae during aerobraking operations at Mars.