Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Classification Analytics of Pu-239 and U-235 Source Signatures Using Gamma Spectral Regions

Machine learning detection methods using gamma signatures from spectral measurements of low-intensity Pu-239 and U-235 sources are studied. NaI detectors located at different distances fromthe source have been used to collect the training and independent testing data sets. The source is introduced via a shielded conduit into the facility where it is surrounded by 21 NaI detectors deployed over 6 x 6 meters area in the formation of two concentric circles and a spiral. The counts in gamma spectral regions associated with these two sources are estimated at 1 second intervals for each NaI detector, and are used as classifier features for detecting the source presence. Eight different classifiers with five basic properties — namely, smooth, non-smooth, statistical, structural, and hyper-parameter tuning — are trained and tested using the background and source measurements collected over multiple experimental runs. While the overall classifier performance improved as detectors closer to the source are used, some identically produced detectors under-performed but differently between two sources. Some classifiers achieved lower training error but their testing error based on independent measurements is higher for both sources. Overall, these results indicate significant over-fitting by these methods, and illustrate the complexity of training and selecting the machine learning methods to solve these detection problems.

Rao, Nageswara↗

Elastic Modulus Testing for TriTruss Struts

The TriTruss is a novel structural module developed by researchers at NASA Langley Research Center (LaRC) that can be used in space to assemble large backing structures for a variety of applications. One such application is the metering truss and primary mirror backbone support structure of an in-space assembled telescope(iSAT). For the iSAT application, the TriTruss will be supporting mirror segments, payloads, and instruments, all of which require the TriTruss to have robust structural integrity. An accurate elastic modulus value is crucial to the finite element analysis(FEA) of the structure. Initial testing indicated that the equivalent elastic modulus provided by the manufacturer and used in the analyses did not accurately predict the behavior of the structure. In this paper, the in-house testing method developed at LaRC to accurately measure the equivalent elastic modulus of the composite struts for use in the analyses is described. A tensile and compressive equivalent elastic modulus was computed from the data obtained in this test. The testing resulted in a tensile equivalent elastic modulus of 24.6 Msi (standard deviation of 0.888 Msi) or 169 GPa (standard deviation of 6.20 GPa) and a compressive equivalent elastic modulus of 22.8 Msi (standard deviation of 0.780 Msi) or 157 GPa(standard deviation of 5.38 GPa) for the single wall thickness struts. For double wall thickness struts, the testing resulted in a tensile equivalent elastic modulus of32.1 Msi (standard deviation of 1.003 Msi) or 221 GPa (standard deviation of 6.91GPa) and a compressive equivalent elastic modulus of 31.9 Msi (standard deviation of 1.123) or 220 GPa (standard deviation of 7.74 GPa).1

TriTruss↗

Long Island Smart Metering Pilot Project

The Long Island Power Authority (LIPA) Smart Meter Pilots provided invaluable information and experience for future deployments of Advanced Metering Infrastructure (AMI), including the deployment planned as part of LIPA's Smart Grid Demonstration Project (DE-OE0000220). LIPA will incorporate lessons learned from this pilot in future deployments, including lessons relating to equipment performance specifications and testing, as well as equipment deployment and tracking issues. LIPA ultimately deployed three AMI technologies instead of the two that were originally contemplated. This enabled LIPA to evaluate multiple systems in field conditions with a relatively small number of meter installations. LIPA experienced a number of equipment and software issues that it did not anticipate, including issues relating to equipment integration, ability to upgrade firmware and software over the air (as opposed to physically interacting with every meter), and logistical challenges associated with tracking inventory and upgrade status of deployed meters. In addition to evaluating the technology, LIPA also piloted new Time-of-Use (TOU) rates to assess customer acceptance of time-differentiated pricing and to evaluate whether customers would respond by adjusting their activities from peak to non-peak periods. LIPA developed a marketing program to educate customers who received AMI in the pilot areas and to seek voluntary participation in TOU pricing. LIPA also guaranteed participating customers that, for their initial year on the rates, their electricity costs under the TOU rate would not exceed the amount they would have paid under the flat rates they would otherwise enjoy. 62 residential customers chose to participate in the TOU rates, and every one of them saved money during the first year. 61 of them also elected to stay on the TOU rate without the cost guarantee at the end of that year. The customer who chose not to continue on the rate was also the one who achieved the greatest savings. However, after the first year, the customer in question installed equipment that would have made TOU rates a more costly option than the residential flat rate. During the second year, all but one customer saved money. That customer increased usage during peak hours, and as a result saw an increase in annual costs (as compared to the flat rate) of $\$$24.17. The results were less clear for commercial customers, which LIPA attributes to rate design issues that it will take into account for future deployments. LIPA views this pilot as a complete success. Not only is LIPA better prepared for a larger deployment of AMI, but it is confident that residential customers will accept AMI and TOU rates and shift their energy consumption from peak to non-peak periods in response to pricing. On a larger scale, this will benefit LIPA and all of its customers by potentially lowering peak demand when energy costs are highest.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identification of Intraday False Data Injection Attack on DER Dispatch Signals

The urgent need for the decarbonization of power grids has accelerated the integration of renewable energy. Concurrently, increasing distributed energy resources (DER) and advanced metering infrastructure (AMI) have transformed the power grids into a more sophisticated cyber-physical system with numerous communication devices. While these transitions provide economic and environmental value, they also impose increased risk of cyber attacks and operation al challenges. This paper investigates the vulnerabilit y of the power grids with high renewable penetration against an intraday false data injection (FDI) attack on DER dispatch signals and proposes a kernel support vector regression (SVR) based detection model as a countermeasure. The intraday FDI attack scenario and the detection model are demonstrated in a numerical experiment using the HCE 187-bus test system.

Kim, Jip↗

Characterizing the Electromagnetic Response of the NOvA Detectors

The NOvA Test Beam Program was commissioned to complement the full-scale NOvA experiment in its goal of measuring neutrino oscillations. The NOvA Experiment consists of a 300-ton Near Detector and a 14-kton Far Detector, both exposed to the same beam, which can be operated in neutrino or antineutrino mode from Fermilab at an off-axis angle of 14.6~mrad. These detectors can discriminate between $\nu_\mu$-CC and $\nu_e$-CC neutrino (or corresponding antineutrino) events, enabling appearance and disappearance measurements of these flavors across the \SI{810}{\kilo\meter} near-to-far detector baseline. From these measurements, the underlying parameters of the three-flavor PMNS oscillations framework are measured. The NOvA Test Beam uses identical technology to the full-scale detectors, but scaled down to 30~tons. It is exposed to a beam of charged particles closely matched to the daughter products of NOvA (anti)neutrino interactions in both energy and species. An instrumented beamline determines both particle momentum and species upstream of the NOvA detector, allowing for a crisp measurement of the NOvA detector response to these known inputs. This dissertation presents an analysis of the electromagnetic response of the NOvA hardware and establishes a framework for incorporating these results to enhance the physics reach of the experiment. Prior to this work, the electromagnetic energy response of the NOvA detector relied primarily on simulation-driven calibration together with a globally applied energy scale uncertainty. The measurements presented here provide direct test beam constraints on the detector response, enabling particle-dependent and potentially energy-dependent uncertainty models derived from controlled electromagnetic inputs.

Myers, Dalton Grant [U. Texas, Austin (main)] (ORC↗

ASSEMBLY AND TEST OF A 120 MM BORE 15 T NB3SN QUADRUPOLE FOR THE LHC UPGRADE

In support of the Large Hadron Collider (LHC) luminosity upgrade, the US LHC Accelerator Research Program (LARP) has been developing a 1-meter long, 120 mm bore Nb{sub 3}Sn IR quadrupole magnet (HQ). With a design short sample gradient of 219 T/m at 1.9 K and a peak field approaching 15 T, one of the main challenges of this magnet is to provide appropriate mechanical support to the coils. Compared to the previous LARP Technology Quadrupole and Long Quadrupole magnets, the purpose of HQ is also to demonstrate accelerator quality features such as alignment and cooling. So far, 8 HQ coils have been fabricated and 4 of them have been assembled and tested in HQ01a. This paper presents the mechanical assembly and test results of HQ01a.

43 PARTICLE ACCELERATORS↗

Approach-Phase Precision Landing with Hazard Relative Navigation: Terrestrial Test Campaign Results of the Morpheus/ALHAT Project

The Morpheus Project began in late 2009 as an ambitious e ort code-named Project M to integrate three ongoing multi-center NASA technology developments: humanoid robotics, liquid oxygen/liquid methane (LOX/LCH4) propulsion and Autonomous Precision Landing and Hazard Avoidance Technology (ALHAT) into a single engineering demonstration mission to be own to the Moon by 2013. The humanoid robot e ort was redirected to a deploy- ment of Robonaut 2 on the International Space Station in February of 2011 while Morpheus continued as a terrestrial eld test project integrating the existing ALHAT Project's tech- nologies into a sub-orbital ight system using the world's rst LOX/LCH4 main propulsion and reaction control system fed from the same blowdown tanks. A series of 33 tethered tests with the Morpheus 1.0 vehicle and Morpheus 1.5 vehicle were conducted from April 2011 - December 2013 before successful, sustained free ights with the primary Vertical Testbed (VTB) navigation con guration began with Free Flight 3 on December 10, 2013. Over the course of the following 12 free ights and 3 tethered ights, components of the ALHAT navigation system were integrated into the Morpheus vehicle, operations, and ight control loop. The ALHAT navigation system was integrated and run concurrently with the VTB navigation system as a reference and fail-safe option in ight (see touchdown position esti- mate comparisons in Fig. 1). Flight testing completed with Free Flight 15 on December 15, 2014 with a completely autonomous Hazard Detection and Avoidance (HDA), integration of surface relative and Hazard Relative Navigation (HRN) measurements into the onboard dual-state inertial estimator Kalman lter software, and landing within 2 meters of the VTB GPS-based navigation solution at the safe landing site target. This paper describes the Mor- pheus joint VTB/ALHAT navigation architecture, the sensors utilized during the terrestrial ight campaign, issues resolved during testing, and the navigation results from the ight tests.

Crain, Timothy P.↗

Advanced Video Guidance Sensor (AVGS) Development Testing

NASA's Marshall Space Flight Center was the driving force behind the development of the Advanced Video Guidance Sensor, an active sensor system that provides near-range sensor data as part of an automatic rendezvous and docking system. The sensor determines the relative positions and attitudes between the active sensor and the passive target at ranges up to 300 meters. The AVGS uses laser diodes to illuminate retro-reflectors in the target, a solid-state camera to detect the return from the target, and image capture electronics and a digital signal processor to convert the video information into the relative positions and attitudes. The AVGS will fly as part of the Demonstration of Autonomous Rendezvous Technologies (DART) in October, 2004. This development effort has required a great deal of testing of various sorts at every phase of development. Some of the test efforts included optical characterization of performance with the intended target, thermal vacuum testing, performance tests in long range vacuum facilities, EMI/EMC tests, and performance testing in dynamic situations. The sensor has been shown to track a target at ranges of up to 300 meters, both in vacuum and ambient conditions, to survive and operate during the thermal vacuum cycling specific to the DART mission, to handle EM1 well, and to perform well in dynamic situations.

Howard, Richard T.↗

Advanced optical smoke meters for jet engine exhaust measurement

Smoke meters with increased sensitivity, improved accuracy, and rapid response are needed to measure the smoke levels emitted by modern jet engines. The standard soiled tape meter in current use is based on filtering, which yields long term averages and is insensitive to low smoke levels. Two new optical smoke meter techniques that promise to overcome these difficulties have been experimentally evaluated: modulated transmission (MODTRAN) and photothermal deflection spectroscopy (PDS). Both techniques are based on light absorption by smoke, which is closely related to smoke density. They are variations on direct transmission measurements which produce a modulated signal that can be easily measured with phase sensitive detection. The MODTRAN and PDS techniques were tested on low levels of smoke and diluted samples of NO2 in nitrogen, simulating light adsorption due to smoke. The results are evaluated against a set of ideal smoke meter criteria that include a desired smoke measurement range of 0.1 to 12 mg cu.m. (smoke numbers of 1 to 50) and a frequency response of 1 per second. The MODTRAN instrument is found to be inaccurate for smoke levels below 3 mg/cu.m. and is able to make a only about once every 20 seconds because of its large sample cell. The PDS instrument meets nearly all the characteristics of an ideal smoke meter: it has excellent sensitivity over a range of smoke levels from 0.1 to 20 mg/cu.m. (smoke numbers of 1 to 60) and good frequency response (1 per second).

Pitz, R. W.↗

Structural Modeling of a Five-Meter Thin Film Inflatable Antenna/Concentrator

Inflatable structures have been the subject of renewed interest in recent years for space applications such as communications antennas, solar thermal propulsion, and space solar power. A major advantage of using inflatable structures in space is their extremely light weight. An obvious second advantage is on-orbit deployability and related space savings in the launch configuration. A recent technology demonstrator flight for inflatable structures was the Inflatable Antenna Experiment (IAE) that was deployed on orbit from the Shuttle Orbiter. Although difficulty was encountered in the inflation/deployment phase, the flight was successful overall and provided valuable experience in the use of such structures. Several papers on static structural analysis of inflated cylinders have been written, describing different techniques such as linear shell theory, and nonlinear and variational methods, but very little work had been done in dynamics of inflatable structures until recent years. In 1988 Leonard indicated that elastic beam bending modes could be utilized in approximating lower-order frequencies of inflatable beams. Main, et al. wrote a very significant 1995 paper describing results of modal tests of inflated cantilever beams and the determination of effective material properties. Changes in material properties for different pressures were also discussed, and the beam model was used in a more complex structure. The paper demonstrated that conventional finite element analysis packages could be very useful in the analysis of complex inflatable structures. The purposes of this paper are to discuss the methodology for dynamically characterizing a large 5-meter thin film inflatable reflector, and to discuss the test arrangement and results. Nonlinear finite element modal results are compared to modal test data. The work is significant and of considerable interest to researchers because of 1) the large size of the structure, making it useful for scaling studies, and 2) application of commercially available finite element software for modeling pressurized thin-film structures.

Smalley, Kurt B.↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018, Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zones results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space Environment Simulator (SES). The flight external radiators are not available during ISIM-Ievel thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided on specially designed test hardware which measures the heat flow within each of the five heat straps to an accuracy of less than 2 m W, which is less than 5% of the minimum predicted heat flow values. This is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. Devices that measure heat flow in this manner have historically been referred to as "Q-meters". Perhaps the most important feature of the design of the Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on a difference in heater power, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, the handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

Passive Digital Sensing Method and Its Implementation on Passive RFID Temperature Sensors

Benefitting from the advancement of digital electronics in the 20 th century, sensors have also gradually evolved from analog to digital. As semiconductor components are required in digital sensors, a power supply is still needed for the sensor. To eliminate the need for a power supply a concept of passive digital sensing is proposed. Different from the semiconductor-based electrical digital sensing method, the parameter to be measured is first converted to a mechanical signal, then the mechanical signal is encoded to multiple digital bits by a passive digitizer, where each bit is identified as open or short state that is detectable by general IO ports. To demonstrate the proposed sensing concept, a passive RFID temperature sensor is implemented using a bimetallic coil as the temperature sensing unit. The 6-bit binary codes are acquired and transmitted by a passive RFID that is powered by an energy harvester. Furthermore, the test results show that the temperature sensor has a measurement sensitivity of 1.32 °C/bit and a working distance over 10 meters.

47 OTHER INSTRUMENTATION↗

Development of low mass optical readout for high data bandwidth systems.

At Argonne National Laboratory the High Energy Physics and Center for Nanoscale Materials Divisions are working on a project to develop a new generation of detector readout using high speed data transfer optical devices that can be implemented in particle physics or for long distances. Free-space communications devices offer the potential for reductions in mass, power, and cost of data paths for on-board trigger and readout of tracking detectors. The project involves three areas of study: light modulation, the design and construction of MEMS optical devices, and the control systems for maintaining precise laser light positioning. We demonstrate an optical link in air over one meter and with low error rate at 1 Gb/s. We demonstrate steering of an optical beam over a meter with a precision of 5 micrometers utilizing a MEMS mirror and reflected light in the feedback loop. For early testing, light modulation tests with a fiber link using Li-Niobate modulators and a data generation and error checking chip are done at 1 Gb/s. Many companies and universities are developing modulators which will be incorporated into CMOS chips. We are doing radiation hardness studies for one of the materials involved. Laser light will need to be steered on to and kept centered on the detector in the presence of thermal or mechanical motion, etc. This steering will be controlled by MEMS mirrors. Polycrystalline and crystalline silicon based mirror designs are being studied. We review the current status of the project and outline plans for the future development of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiocarbon constraints imply reduced carbon uptake by soils during the 21st century

Soil is the largest terrestrial carbon reservoir and may influence the sign and magnitude of carbon cycle-climate feedbacks. Many Earth system models (ESMs) estimate a significant soil carbon sink by 2100, yet the underlying carbon dynamics determining this response have not been systematically tested against observations. For this research, we used 14 C data from 157 globally distributed soil profiles sampled to 1-meter depth to show that ESMs underestimated the mean age of soil carbon by a factor of more than six (430 ± 50 years versus 3100 ± 1800 years). Consequently, ESMs overestimated the arbon sequestration potential of soils by a factor of nearly two (40 ± 27%). Finally, these inconsistencies suggest that ESMs must better represent carbon stabilization processes and the turnover time of slow and passive reservoirs when simulating future atmospheric carbon dioxide dynamics.

54 ENVIRONMENTAL SCIENCES↗

An integral test of the inelastic cross sections of Pb and Mo using measured neutron spectra

Comparison of measurements and calculations of fast neutron spectra from a radioactive neutron source inside spheres of Mo or Pb and from a cylindrical reactor containing a thick Pb or Mo reflector are used as a test of ENDF cross sections. The sphere leakage spectra were measured at a sphere-to-spectrometer distance of 2 meters using a 54 Ci spherical Am-Be neutron source. Reactor leakage spectrum measurements were made at the surface of the ZP-1 reactor when bare, with a Pb radial reflector 21 cm thick, and with a metallic Mo radial reflector 10 cm thick. In the case of the thin Mo sphere there is agreement between the calculation and measurement. The Pb calculation is much lower than the measurement except at the highest neutron energy. Two-dimensional calculations of reactor spectra result indicate that the reactor source is reasonably well known. Significant differences in leakage spectrum shape for both Mo and Pb reflectors suggest that there are large uncertainties in the inelastic cross sections for Pb and some for Mo.

Shook, D. F.↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

True airspeed measured by airborne laser Doppler velocimeter

Velocimeter utilizing carbon dioxide laser measures true airspeed of aircraft. Results of flight tests indicate that clear-weather airspeeds can be measured with accuracy better than 0.1% at altitudes up to 3000 meters; measurements can be made at much greater altitudes in cloudy or turbid air.

Munoz, R.↗

Transonic wind-tunnel tests of an F-8 airplane model equipped with 12 and 14-percent thick oblique wings

An experimental investigation was conducted in the Ames 14-foot transonic wind tunnel to study the aerodynamic performance and stability characteristics of a 0.087-scale model of an F-8 airplane fitted with an oblique wing. Two elliptical planform (axis ratio = 8:1) wings, each having a maximum thickness of 12 and 14 percent, were tested. Longitudinal stability data were obtained with no wing and with each of the two wings set at sweep angles of 0, 45, and 60 deg. Lateral directional stability data were obtained for the 12 percent wing only. Test Mach numbers ranged from 0.6 to 1.2 in the unit Reynolds number range from 11.2 to 13.1 million per meter. Angles of attack were between -6 and 22 deg at zero sideslip. Angles of sideslip were between -6 and +6 deg for two angles of attack, depending upon the wing configuration.

Smith, R. C.↗