Flattening of fuel importance for heterogeneous system to estimate maximal multiplication factor - 14595
In order to quantify risks of re-criticality incidents associated with loss of coolant accidents (LOCA), the maximum reactivity insertion by relocation of damaged fuel should be quantified. As the first step for the quantification, an automated search scheme is studied for an optimal geometry of damaged fuel in the coolant channel where the neutron multiplication factor k{sub eff} takes a maximal value. The scheme is based on the flattening of the fuel importance. The importance can be recognized as the substitution reactivity from fuel to water in heterogeneous systems. The flattening is achieved by substitution of water and the fuel so as to raise the k{sub eff} referring the local substitution reactivities. To calculate the reactivities efficiently, the first order perturbation scheme is adopted. In the scheme, the adjoint flux is calculated with the PARTISN code. The multi group constants used for the calculation and the perturbed reaction rates are estimated with the continuous energy Monte Carlo code MCNP-5. The proposed methods are tested for a quarter pin cell model that is constructed using Cartesian mesh. From a random distribution of a given amount of fragmented fuel, an optimal geometry is found where the fragmented fuels are aggregated. The multiplication factor in the geometry is greater than that in the original random distribution by 1.4%Δk/k. That indicates the significance of this study. (authors)