Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Rapid Polymer Sequencer

Solid-state nanopore-based analysis of nucleic acid polymers is revolutionary. No other technique can determine information content in single molecules of genetic material at the speed of 1 subunit per microsecond. Because individual molecules are counted, the output is intrinsically quantitative. The nanopore approach is more generalized than any other method and in principle may be used to analyze any polymer molecule, including proteins. The approach to the development of a solid-state nanopore device is novel in the use of nanofabrication, nanoelectronic components, and high-speed signal acquisition. A novel geometry of the solid-state nanopore (less than 5 nm in length and 5 nm in diameter) will enable 1 to 5 nucleotide resolution measurements. This means that maximum resolution will be improved at least 100-fold compared to biological ion-channel measurements. The solid-state nanopore sensor will be made to enable sequencing DNA at a much faster rate than presently possible without the need for extensive sample preparation procedures, such as enzymatic amplification and labeling reactions. It will analyze electronic properties of individual subunits of DNA or RNA, to obtain linear composition of each genetic polymer molecule.

technology opportunity↗

Interpretation of Observations of Trans-Spectral Phenomena Acquired Using Hyperspectral Sensors Aboard a Remotely Operated Vehicle in Exuma Sound

Hyper-spectral (512-channel) optical data acquired during a relatively deep (102m) dive of our ROSEBUD Remotely Operated Vehicle (ROV) in the clear waters of Exuma Sound, Bahamas provided the opportunity to investigate the trans-spectral shift of photonic energy (inelastic scattering) as a function of water depth. Results show a convolution of several spectral processes (e.g. absorption, scattering) involving water molecules, dissolved material and particulates as well as trans-spectral (inelastic) processes involving fluorescence by water molecules (Raman), dissolved material and chlorophyll. The spectral signatures of these convolved causes and effects allow deconvolution with a hyperspectral approach. Intrinsic to the convolution was the ability to position the vehicle at depths where Raman fluorescence dominated at red wavelengths. Results show that the calculated Raman absorption coefficients are generally consistent with historical values (i.e. 0.9 x 10(sup)-4 at 525 nm excitation) and that an angstrom exponent of 5 is more appropriate than the often cited value of 4.

Costello, D.↗

High-Resolution Thermal X-Ray Detector

Thermal pulses from single photons measured. Detector, consists of X-ray absorber, temperature sensor in absorber, and thermal link from absorber to heat sink. X-ray photon detected by measuring temperature rise immediately following absorption of photon. Thermal X-ray detector, tested successfully in prototype, in theory operates as spectrometer that provides 100 times spectral resolution of conventional to detect trace constituents in materials by X-ray fluorescence. Also used for measuring energies of energetic electrons and weak pulses of light.

Moseley, S. H.↗

Dynamics of the Molten Contact Line

The purpose of this program is to develop a basic understanding of how a molten material front spreads over a solid that is below its melting point, arrests, and freezes. Our hope is that the work will contribute toward a scientific knowledge base for certain new applications involving molten droplet deposition, including the "printing" of arbitrary three-dimensional objects by precise deposition of individual molten microdrops that solidify after impact. Little information is available at this time on the capillarity-driven motion and arrest of molten contact line regions. Schiaffino and Sonin investigated the arrest of the contact line of a molten microcrystalline wax spreading over a subcooled solid "target" of the same material. They found that contact line arrest takes place at an apparent liquid contact angle that depends primarily on the Stefan number S=c(T(sub f) -T(sub t)/L based on the temperature difference between the fusion point and the target temperature, and proposed that contact line arrest occurs when the liquid's dynamic contact angle approaches the angle of attack of the solidification front just behind the contact line. They also showed, however, that the conventional continuum equations and boundary conditions have no meaningful solution for this angle. The solidification front angle is determined by the heat flux just behind the contact line, and the heat flux is singular at that point. By comparing experiments with numerical computations, Schiaffino and Sonin estimated that the conventional solidification model must break down within a distance of order 0.1 - 1 microns of the contact line. The physical mechanism for this breakdown is as yet undetermined, and no first-principles theory exists for the contact angle at arrest. Schiaffino and Sonin also presented a framework for understanding how to moderate Weber number molten droplet deposition in terms of similarity laws and experimentation. The study is based on experiments with three molten materials- molten wax on solid wax, water on ice, and mercury on frozen mercury- which between them span a considerable range of the deposition/solidification similarity parameters. Correlations are obtained for the spreading velocity, spreading time scales, the spreading factor (i.e. ratio of deposited drop's final footprint radius and the drop's initial radius), post-spreading liquid oscillation amplitudes and time scales, and bulk solidification time scales. Duthaler carried out an experimental and theoretical investigation of the relationship between the liquid's apparent contact angle and the Capillary number Ca=mu U/sigma based on contact line speed, for molten materials spreading over subcooled solids. This relationship is required for modeling of melt spreading. We have adapted Voinov's methodology to the molten contact line and formulated a theoretical model for the Ca vs. contact angle relationship, based Schiaffino and Sonin#s (1997a,b) wedge-like solidification front model. With the solidification front angle taken from Schiaffino and Sonin, the model is in good agreement with the experimental results for Ca vs. contact angle. Duthaler also extended the experimental investigation of droplet deposition and contact line freezing to more materials, including solder on glass, solder on solder, water on ice, and molten microcrystalline wax on wax. The latter also included tests on inclined targets. Deposition tests have also been done with molten octacosane (C28H58) on various targets. An important objective of our program has been the development of micron-scale sensors for measuring the transient temperature at a point on the substrate surface as a molten contact line moves over it. The expectation is that this temperature history will yield a better understanding of the thermal process in the contact line region. The sensors are of the thermistor type, either 2.5 microns or 1.5 microns square, microfabricated with silicon-based technology on either pure silicon or amorphous silicon dioxide chips. Each chip has 32 sensors distributed on its surface in arrays. The time response is better than 10 ms. At the time of writing, sensor calibration is in progress. Results on thermal transients during contact line passage will be discussed at the conference. While we expect that the data will provide information on the near-contact-line heat transfer process, we also foresee possible problems. First, the spatial resolution of the sensors may be insufficient to resolve the near-contact-line region. Second, the sensors protrude about 0.5 microns above the substrate surface, and may affect the contact line motion. Third, a sensor's temperature history depends on both the heat flux distribution into it from the fusion front and the thermal properties of the substrate below it and the solidified melt between it and the fusion front. The heat flux distribution in the contact line region must therefore be unfolded from computations of the overall system's transient thermal response.

Sonin, Ain A.↗

Overview of Active Flow Control at NASA Langley Research Center

The paper summarizes Active Flow Control projects currently underway at the NASA Langley Research Center. Technology development is being pursued within a multidisciplinary, cooperative approach, involving the classical disciplines of fluid mechanics, structural mechanics, material science, acoustics, and stability and control theory. Complementing the companion papers in this session, the present paper will focus on projects that have the goal of extending the state-of-the-art in the measurement, prediction, and control of unsteady, nonlinear aerodynamics. Toward this goal, innovative actuators, micro and macro sensors, and control strategies are considered for high payoff flow control applications. The target payoffs are outlined within each section below. Validation of the approaches range from bench-top experiments to wind-tunnel experiments to flight tests. Obtaining correlations for future actuator and sensor designs are implicit in the discussion. The products of the demonstration projects and design tool development from the fundamental NASA R&D level technology will then be transferred to the Applied Research components within NASA, DOD, and US Industry. Keywords: active flow control, separation control, MEMS, review

Pack, L. G.↗

Post-flight Analysis of Mars Science Laboratory Entry Aerothermal Environment and Thermal Protection System Response

The Mars Science Laboratory successfully landed on the Martian surface on August 5th, 2012. The rover was protected from the extreme heating environments of atmospheric entry by an ablative heatshield. This Phenolic Impregnated Carbon Ablator heatshield was instrumented with a suite of embedded thermocouples, isotherm sensors, and pressure transducers. The sensors monitored the in-depth ablator response, as well as the surface pressure at discrete locations throughout the hypersonic deceleration. This paper presents a comparison of the flight data with post-entry estimates. An assessment of the aerothermal environments, as well as the in-depth response of the heatshield material is made, and conclusions regarding the overall performance of the ablator at the suite locations are presented.

mars science laboratory↗

Prospects for the Development of Fast-Light Inertial Sensors

Next-generation space missions are constrained by existing spacecraft navigation systems which are not fully autonomous. These systems suffer from accumulated dead-reckoning errors and must therefore rely on periodic updates provided by supplementary technologies that depend on line-of-sight signals from Earth, satellites, or other celestial bodies (e.g., GPS, star-trackers) for absolute attitude and position determination, which can be spoofed, incorrectly identified, occluded, obscured, attenuated, or insufficiently available. These dead-reckoning errors originate in the accelerometers and ring laser gyros (RLGs) themselves, which constitute inertial measurement units (IMUs). Increasing the time for standalone spacecraft navigation therefore requires fundamental improvements in the precision of inertial sensors. The conventional method of increasing the precision of an optical gyro is to increase its size, but this is problematic in spaceflight where size and weight are at a premium. One promising solution to enhance gyro precision without increasing size is to place an anomalous dispersion or fast-light (FL) material inside the gyro cavity. The FL essentially provides a positive feedback to the gyro response, resulting in a larger measured beat frequency for a given rotation rate as shown in figure 1.

Smith, D. D.↗

Seasonal Bias in Global Ocean Color Observations

In this study we identify a seasonal bias in the ocean color satellite derived remote sensing reflectances (Rrs(λ); sr-1) at the ocean color validation site, MOBY (Marine Optical BuoY). The seasonal bias in Rrs(λ) is present to varying degrees in all ocean color satellites examined, including VIIRS (Visible Infrared Imaging Radiometer Suite), SeaWiFS (Sea-viewing Wide Field-of-view Sensor), and MODIS (Moderate Resolution Imaging Spectrometer). The relative bias in Rrs has spectral dependence. Products derived from Rrs(λ) are affected by the bias to varying degrees, with particulate backscattering varying up to 50% over a year, chlorophyll varying up to 25% over a year, and absorption from phytoplankton or dissolved material varying by up to 15%. The propagation of Rrs(λ) bias into derived products is broadly confirmed on regional and global scales using Argo floats and data from the CALIOP (Cloud-Aerosol Lidar with Orthogonal Polarization) instrument aboard the CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder) satellite. The artifactual seasonality in ocean color is prominent in areas of low biomass (i.e., subtropical gyres) and is not easily discerned in areas of high biomass. While we have eliminated several candidates that could cause the biases in Rrs(λ), there are still outstanding questions regarding potential contributions from atmospheric corrections. Specifically, we provide evidence that the aquatic bidirectional reflectance distribution function may in part cause the observed seasonal bias, but this does not preclude an additional effect of the aerosol estimation. Our investigation highlights the contributions that atmospheric correction schemes can make in introducing biases in Rrs (λ) and we recommend more simulations to discern these influence Rrs (λ) biases. Community efforts are needed to find the root cause of the seasonal bias because all past, present, and future data are or will be affected until a solution is implemented.

satellite ocean color↗

Trace Oxygen Measurements of Asteroid Sample Storage Desiccators

The Astromaterials Curation facility at the NASA Johnson Space Center is currently curating more than 120 g of carbonaceous asteroid Bennu material as well as over 500 mg of asteroid Ryugu [1 and 2]. These astromaterials are stored in isolating desiccators and gloveboxes under a continuous purge of pure (<1 ppm O 2 ) gaseous nitrogen. The oxygen and moisture concentrations in our OSIRIS-REx sample processing gloveboxes are continuously monitored via integrated sensors; however, our sample storage desiccators lack integrated oxygen and humidity sensors. In previous studies, we used PreSens Fibox 4 trace oxygen meters and optochemical PSt9 spot sensors to measure the oxygen concentrations in candidate asteroid sample containers that had been sealed in nitrogen; we determined that Eagle stainless steel containers inhibit the ingress of external oxygen for several weeks [3]. This optochemical sensor technology allowed us to take precise, contactless measurements within a trace range of 0 to 200 ppmv O 2 . The effectiveness of the trace oxygen sensors in our container experiments inspired us to utilize them to assess the performance of our desiccators that previously lacked trace oxygen monitoring. In this study, our goal was to determine the quality of the nitrogen purge in the isolating desiccator under normal operating conditions by measuring the trace oxygen content. Utilizing optochemical sensor technology, we determined how long the oxygen concentration takes to reach an equilibrium in the desiccator; that is, determine the rate at which the oxygen diffusion into the desiccator equals the rate at which oxygen diffuses out of the desiccator via N2 purge. Additionally, we wanted to determine the oxygen concentration at this equilibrium, the state in which our desiccators are in during normal operating conditions. We tested a custom three chamber desiccator manufactured by Germfree using a PSt9 trace oxygen sensor spot that was mounted into a ¼” National Pipe Tapered (NPT) metal flow-through cell and attached it to the desiccator exhaust. The desiccator consists of top, middle, and bottom isolating chambers. The top chamber door was opened for several minutes to simulate a sample exchange, it was sealed, and then purged ~15 Standard Cubic Feet per Hour (SCFH). Oxygen measurements were automatically recorded via the Fibox 4 trace oxygen meter in 5-minute intervals over the course of a 24-hour period. Our results indicate the desiccator reached an equilibrium value of 10-15 ppm O 2 after ~5 hours (Fig. 1). This data allows us to explore standards for purging and exchange protocols that can be applied to similar types of desiccators in Hayabusa2, OSIRIS-REx, and for sample return collections. The assessment of the internal gaseous compositions of desiccators also allows us to share with the community the N 2 environment in which many of our asteroid samples and hardware are securely curated. Future measurements will include other nitrogen flow rates and measuring the trace oxygen concentration as a function of time for the levels of the previous commercial desiccator in which the Hayabusa2 sample collection was stored. We will also analyze how long the desiccators hold N2 after being disconnected from their N2 source, an extended measurement for sample security reassurance.

Curation↗

Noise power spectral density of the Sundstrand QA-2000 accelerometer

There are no good data on low frequency (less than 0.1 Hz) power spectral density (PSD) for the Q-Flex accelerometer. However, some preliminary stability measurements were made over periods of 12 to 24 hours and demonstrated stability less than 0.5 micro-g over greater than 12 hours. The test data appear to contain significant contributions from temperature variations at that level, so the true sensor contribution may be less than that. If what was seen could be construed as a true random process, it would correspond to about 0.1 micro-g rms over a bandwidth from 10(exp -5) Hz to about 1 Hz. Other studies of low frequency PSD in flexure accelerometers have indicated that material aging effects tend to approximate a first order Markhov process. If we combine such a model with the spectrum obtained at higher frequencies, it suggests the spectrum shown here as a conservative estimate of Q-Flex noise performance.

Peters, Rex↗

Spatial and spectral characterization of acid rain stress in Canadian Shield lakes

Results from this study demonstrate that a remote sensor can discriminate lake clarity based upon reflection. The basic hypothesis was that seasonal and multiyear changes in lake optical transparency are indicative of sensitivity to acidic deposition. In many acid-sensitive lakes optical transparency is controlled by the amount of dissolved organic carbon (DOC) present. DOC is a strong absorbing, nonscattering material which has the greatest impact at short visible wavelengths, including Thematic Mapper band 1. Acid-sensitive lakes have high concentrations of aluminum which have been mobilized by acidic components contained in the runoff. Aluminum complexing with DOC is considered to be the primary mechanism to account for observed increases in lake transparency in acid-sensitive lakes. Thus seasonal changes in the optical transparency of lakes should provide an indication of the stress due to acid deposition and loading.

Marshall, Elizabeth J.↗

Microencapsulation system and method

A microencapsulation apparatus is provided which is configured to form co-axial multi-lamellar microcapsules from materials discharged from first and second microsphere dispensers of the apparatus. A method of fabricating and processing microcapsules is also provided which includes forming distinct droplets comprising one or more materials and introducing the droplets directly into a solution bath to form a membrane around the droplets such that a plurality of microcapsules are formed. A microencapsulation system is provided which includes a microcapsule production unit, a fluidized passage for washing and harvesting microcapsules dispensed from the microcapsule production unit and a flow sensor for sizing and counting the microcapsules. In some embodiments, the microencapsulation system may further include a controller configured to simultaneously operate the microcapsule production unit, fluidized passage and flow sensor to process the microcapsules in a continuous manner.

Morrison, Dennis R.↗

Microencapsulation system and method

A microencapsulation apparatus is provided which is configured to form co-axial multi-lamellar microcapsules from materials discharged from first and second microsphere dispensers of the apparatus. A method of fabricating and processing microcapsules is also provided which includes forming distinct droplets comprising one or more materials and introducing the droplets directly into a solution bath to form a membrane around the droplets such that a plurality of microcapsules are formed. A microencapsulation system is provided which includes a microcapsule production unit, a fluidized passage for washing and harvesting microcapsules dispensed from the microcapsule production unit and a flow sensor for sizing and counting the microcapsules. In some embodiments, the microencapsulation system may further include a controller configured to simultaneously operate the microcapsule production unit, fluidized passage and flow sensor to process the microcapsules in a continuous manner.

Morrison, Dennis R.↗

Improved Readout Scheme for SQUID-Based Thermometry

An improved readout scheme has been proposed for high-resolution thermometers, (HRTs) based on the use of superconducting quantum interference devices (SQUIDs) to measure temperature- dependent magnetic susceptibilities. The proposed scheme would eliminate counting ambiguities that arise in the conventional scheme, while maintaining the superior magnetic-flux sensitivity of the conventional scheme. The proposed scheme is expected to be especially beneficial for HRT-based temperature control of multiplexed SQUIDbased bolometer sensor arrays. SQUID-based HRTs have become standard for measuring and controlling temperatures in the sub-nano-Kelvin temperature range in a broad range of low-temperature scientific and engineering applications. A typical SQUIDbased HRT that utilizes the conventional scheme includes a coil wound on a core made of a material that has temperature- dependent magnetic susceptibility in the temperature range of interest. The core and the coil are placed in a DC magnetic field provided either by a permanent magnet or as magnetic flux inside a superconducting outer wall. The aforementioned coil is connected to an input coil of a SQUID. Changes in temperature lead to changes in the susceptibility of the core and to changes in the magnetic flux detected by the SQUID. The SQUID readout instrumentation is capable of measuring magnetic-flux changes that correspond to temperature changes down to a noise limit .0.1 nK/Hz1/2. When the flux exceeds a few fundamental flux units, which typically corresponds to a temperature of .100 nK, the SQUID is reset. The temperature range can be greatly expanded if the reset events are carefully tracked and counted, either by a computer running appropriate software or by a dedicated piece of hardware.

Penanen, Konstantin↗

Lunar surface magnetometers

Discussion of the properties of both the stationary and portable magnetometers used in the Apollo program to measure static and dynamic fields on the lunar surface. A stationary magnetometer is described in which the three orthogonal vector components of the magnetic field are measured by three fluxgate sensors which are located at the ends of three orthogonal booms and contain ferromagnetic cores driven to saturation by means of a periodic current. In the Apollo 16 magnetometer special high-stability ring-core sensors were used which provided an output voltage to the analog-to-digital converter which is proportional to the magnetic field. A portable magnetometer is described which consists of a set of three orthogonal fluxgate sensors mounted on top of a tripod connected to an electronics box by a ribbon cable. The above-mentioned stationary magnetometer simultaneously measured the time-varying components of the field which were later subtracted from the portable magnetometer measurements to give the desired resultant steady field values caused by the magnetized crustal material.

Dyal, P.↗

Sputtering and ion plating for aerospace applications

Sputtering and ion plating technologies are reviewed in terms of their potential and present uses in the aerospace industry. Sputtering offers great universality and flexibility in depositing any material or in the synthesis of new ones. The sputter deposition process has two areas of interest: thin film and fabrication technology. Thin film sputtering technology is primarily used for aerospace mechanical components to reduce friction, wear, erosion, corrosion, high temperature oxidation, diffusion and fatigue, and also to sputter-construct temperature and strain sensors for aircraft engines. Sputter fabrication is used in intricate aircraft component manufacturing. Ion plating applications are discussed in terms of the high energy evaporant flux and the high throwing power. Excellent adherence and 3 dimensional coverage are the primary attributes of this technology.

Spalvins, T.↗

Sputtering and ion plating for aerospace applications

Sputtering and ion plating technologies are reviewed in terms of their potential and present uses in the aerospace industry. Sputtering offers great universality and flexibility in depositing any material or in the synthesis of new ones. The sputter deposition process has two areas of interest: thin film and fabrication technology. Thin film sputtering technology is primarily used for aerospace mechanical components to reduce friction, wear, erosion, corrosion, high temperature oxidation, diffusion and fatigue, and also to sputter-construct temperature and strain sensors for aircraft engines. Sputter fabrication is used in intricate aircraft component manufacturing. Ion plating applications are discussed in terms of the high energy evaporant flux and the high throwing power. Excellent adherence and 3-dimensional coverage are the primary attributes of this technology.

Spalvins, T.↗

Modeling misregistration and related effects on multispectral classification

Any noise in measurements (due to the scene, sensor, or the analog to digital process) causes a finite fraction of measurements to fall outside of the classification limits. For field boundaries, where the misregistration effects are felt, the misregistration causes the border in a given (set of) band(s) to be closer than expected to a given pixel, so that the mixed materials in the pixels cause additional pixels to fall outside of the class limits. Considerations of the transient distance involved in the difference in brightness between adjacent fields, when scaled to "per pixel", allow the estimation of the width of the border zones. The entire problem is then scaled to field sizes to allow estimation of the global effects. This approach allows the estimation of the accuracy of multispectral classification which might be expected for field interiors, the useful number of quantization bits, and one set of criteria for an unbiased classifier.

Billingsley, F. C.↗