Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A Theoretical Light Scattering Model of Nanoparticle Laser Tweezers

Accomplishments this reporting period include: 1. derived, programmed, checked, and tested the Mie light scattering theory formulas for the radiation trapping force for both the on-axis and off-axis geometry of the trapping beam plus trapped spherical particle; 2. verified that the computed radiation trapping force for a freely propagating focused Gaussian laser beam incident on a spherical particle agrees with previous published calculations; 3. compared the small particle size and large particle size limits of the Mie calculation with the results of Rayleigh scattering theory and ray scattering theory, respectively and verified that the comparison is correct for Rayleigh scattering theory but found that ray theory omits an important light scattering effect included in the Mie theory treatment; 4. generalized the calculation of the radiation trapping force on a spherical particle in the on-axis geometry from a freely propagating focused Gaussian laser beam to the realistic situation of a Gaussian beam truncated and focused by a high numerical aperture oil-immersion microscope objective lens and aberrated by the interface between the microscope cover slip and the liquid-filled sample volume; and 5. compared the calculated radiation trapping force for this geometry with the results of previously published experiments and found that the agreement is better than when using previously developed theories.

Lock, James A.↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Automated qualification data tool for high temperature metallic materials

This report describes a framework for storing, processing, and displaying qualification data for high temperature mechanical properties. The framework automates the process of generating design data from mechanical test results, for example for a data qualification report for the ASME Boiler \& Pressure Vessel Code. The framework has three parts: a data storage model with common formats for several types of typical mechanical property tests, a backend based on the \pycreep Python library for correlating and extrapolating the data to generate design material properties and allowable stresses, and a demonstration user interface for displaying, sorting, and filtering the data and exploring different options for modeling the design mechanical properties. The report discusses the options available for data processing, with illustrations from real test data on Alloy 617, Alloy 709, Alloy 740H, and Laser-Powder Bed Fusion 316H. The framework is complete for ASME type data analysis and will be used to store test data generated by the Department of Energy, Office of Nuclear Energy, Advanced Materials and Manufacturing Technologies sponsored qualification programs. Future work could extend the tool to other types of material properties and/or expand the demo user interface to make it accessible across the AMMT program.

36 MATERIALS SCIENCE↗

Time differentiated nuclear resonance spectroscopy coupled with pulsed laser heating in diamond anvil cells

Developments in pulsed laser heating applied to nuclear resonance techniques are presented together with their applications to studies of geophysically relevant materials. Continuous laser heating in diamond anvil cells is a widely used method to generate extreme temperatures at static high pressure conditions in order to study the structure and properties of materials found in deep planetary interiors. The pulsed laser heating technique has advantages over continuous heating, including prevention of the spreading of heated sample and/or the pressure medium and, thus, a better stability of the heating process. Time differentiated data acquisition coupled with pulsed laser heating in diamond anvil cells was successfully tested at the Nuclear Resonance beamline (ID18) of the European Synchrotron Radiation Facility. We show examples applying the method to investigation of an assemblage containing ε-Fe, FeO, and Fe{sub 3}C using synchrotron Mössbauer source spectroscopy, FeCO{sub 3} using nuclear inelastic scattering, and Fe{sub 2}O{sub 3} using nuclear forward scattering. These examples demonstrate the applicability of pulsed laser heating in diamond anvil cells to spectroscopic techniques with long data acquisition times, because it enables stable pulsed heating with data collection at specific time intervals that are synchronized with laser pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of C{sup 6+} laser ion source and RFQ linac for carbon ion radiotherapy

A prototype C{sup 6+} injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micropillar compression response of femtosecond laser-cut single crystal Cu and proton irradiated Cu

Femtosecond laser cutting has been used to fabricate micro- and mesoscale specimens for mechanical testing, but the impact on mechanical properties has not been fully evaluated. Micropillars of assorted sizes were fabricated in a single crystal Cu specimen and Cu irradiated to 1.4 peak displacements per atom using a femtosecond laser cutting system followed by focused ion beam milling to a final dimension of 7 μm x 7 μm x 12 μm. Microcompression testing showed that removing 5 μm of material from the laser cut surface in both specimens resulted in similar behavior to purely focused ion beam milled micropillars.

36 MATERIALS SCIENCE↗

Laser Surface Processing of Alloys for Corrosion Protection (Final Project Report of Marine Energy Seedling Project)

This is the final project report for the MHK Seedling project. The report describes use of laser surface processing (LSP) to modify the surface of test materials (Al, steel) and the corrosion testing performed on the resulting samples in different corrosion environments. Data shows that LSP improved the corrosion resistance of Al and steel used in this work relative to respective non-LSP samples. The data also showed that each material had a specific range of laser processing conditions where the beneficial effects of LSP (i.e. improvement in corrosion protection) were observed. Application of LSP to enable low-cost materials in marine environments, additional microstructural analysis and long-term testing are proposed to further develop this technology for marine renewable energy and systems.

36 MATERIALS SCIENCE↗

Design improvement of the three-beam detector towards a precise long-range 6-degree of freedom motion sensor system

This paper presents performance enhancement of the three beam detector through design improvement based on the error analysis. The three-beam detector is a novel sensor system that measures six motions (i.e., 3 translations and 3 rotations) of a remote object with high accuracy by implementing three laser distance sensors and a vision sensor. In this paper, finite element analysis and parameter analysis are applied to the three-beam detector to analyze its structural frames and sensor configuration, respectively, in terms of sensing error. By virtue of such a systematic, quantitative error analysis, this research has successfully improved the performance of the three-beam detector and thoroughly validated through field tests that it can detect the 6-degree of freedom motions of a remote target at 30 m with an accuracy of 1.51 mm and 0.18° and precision of 0.38 mm and 0.13°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terahertz inline wall thickness monitoring system for plastic pipe extrusion

Conventional and commercially available inline wall thickness monitoring systems for pipe extrusion are usually based on ultrasonic or x-ray technology. Disadvantages of ultrasonic systems are the usual need of water as a coupling media and the high damping in thick walled or foamed pipes. For x-ray systems special safety requirements have to be taken into account because of the ionizing radiation. The terahertz (THz) technology offers a novel approach to solve these problems. THz waves have many properties which are suitable for the non-destructive testing of plastics. The absorption of electrical isolators is typically very low and the radiation is non-ionizing in comparison to x-rays. Through the electromagnetic origin of the THz waves they can be used for contact free measurements. Foams show a much lower absorption in contrast to acoustic waves. The developed system uses THz pulses which are generated by stimulating photoconductive switches with femtosecond laser pulses. The time of flight of THz pulses can be determined with a resolution in the magnitude of several ten femtoseconds. Hence the thickness of an object like plastic pipes can be determined with a high accuracy by measuring the time delay between two reflections on materials interfaces e.g. at the pipe's inner and outer surface, similar to the ultrasonic technique. Knowing the refractive index of the sample the absolute layer thickness from the transit time difference can be calculated easily. This method in principle also allows the measurement of multilayer systems and the characterization of foamed pipes.

36 MATERIALS SCIENCE↗

Uranium corrosion characterization by handheld laser-induced breakdown spectroscopy

In this study, a commercial-off-the-shelf handheld laser-induced breakdown spectroscopy system was modified, calibrated and tested for discrimination between uranium oxide and uranium hydride when assessing uranium corrosion products. Operating parameters, system modifications, and onboard data analysis were developed to accomplish the analytical task. This work represents the first laser-induced breakdown spectroscopy analysis of bulk uranium hydride, a pyrophoric material, within an inert glovebox. Finally, the work shown here illustrates a rapid identification technique for uranium corrosion types from pure UO 2 or U 3 O 8 to pure UH 3 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Demonstration of improved laser preheat with a cryogenically cooled magnetized liner inertial fusion platform

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ~89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. Furthermore, the integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

47 OTHER INSTRUMENTATION↗

Technology research for strapdown inertial experiment and digital flight control and guidance

A helicopter flight-test program to evaluate the performance of Honeywell's Tetrad - a strapdown, laser gyro, inertial navitation system is discussed. The results of 34 flights showed a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n.mi., with a standard deviation of 1.48 n.m.; and a modeled mean-position-error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. Tetrad's four-ring laser gyros provided reliable and accurate angular rate sensing during the test program and on sensor failures were detected during the evaluation. Criteria suitable for investigating cockpit systems in rotorcraft were developed. This criteria led to the development of two basic simulators. The first was a standard simulator which could be used to obtain baseline information for studying pilot workload and interactions. The second was an advanced simulator which integrated the RODAAS developed by Honeywell into this simulator. The second area also included surveying the aerospace industry to determine the level of use and impact of microcomputers and related components on avionics systems.

Carestia, R. A.↗

High Temperature Damping Behavior of Plasma-Sprayed Thermal Barrier and Protective Coatings

A high temperature damping test apparatus has been developed using a high heat flux CO 2 laser rig in conjunction with a TIRA S540 25 kHz Shaker and Polytec OFV 5000 Vibrometer system. The test rig has been successfully used to determine the damping performance of metallic and ceramic protective coating systems at high temperature for turbine engine applications. The initial work has been primarily focused on the microstructure and processing effects on the coating temperature-dependence damping behavior. Advanced ceramic coatings, including multicomponent tetragonal and cubic phase thermal barrier coatings, along with composite bond coats, have also been investigated. The coating high temperature damping mechanisms will also be discussed.

Zhu, Dongming↗

Absolute Density Calibration Cell for Laser Induced Fluorescence Erosion Rate Measurements

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser-induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. This work examines the suitability of the density cell as an absolute calibration source for LIF measurements, and the intrinsic error was evaluated.

Domonkos, Matthew T.↗

JT9D performance deterioration results from a simulated aerodynamic load test

The results of testing to identify the effects of simulated aerodynamic flight loads on JT9D engine performance are presented. The test results were also used to refine previous analytical studies on the impact of aerodynamic flight loads on performance losses. To accomplish these objectives, a JT9D-7AH engine was assembled with average production clearances and new seals as well as extensive instrumentation to monitor engine performance, case temperatures, and blade tip clearance changes. A special loading device was designed and constructed to permit application of known moments and shear forces to the engine by the use of cables placed around the flight inlet. The test was conducted in the Pratt & Whitney Aircraft X-Ray Test Facility to permit the use of X-ray techniques in conjunction with laser blade tip proximity probes to monitor important engine clearance changes. Upon completion of the test program, the test engine was disassembled, and the condition of gas path parts and final clearances were documented. The test results indicate that the engine lost 1.1 percent in thrust specific fuel consumption (TSFC), as measured under sea level static conditions, due to increased operating clearances caused by simulated flight loads. This compares with 0.9 percent predicted by the analytical model and previous study efforts.

Stakolich, E. G.↗

Graphite polyimide fabrication research for supersonic cruise aircraft

Advanced fabrication processes and adhesive bonding methods have been developed for the fabrication of full scale fiberglass-polyimide honeycomb stiffened HTS-1 graphite/PMR-15 polyimide panels that meet the design criteria for an upper wing panel of the NASA YF-12 aircraft. Detailed manufacturing, bonding, and autoclave cure procedures are presented. Nondestructive test methods including pulse echo and through-transmission ultrasonic C-scan and laser holography were developed to detect flaws in components and the completed panels. Panels were tested in shear at room temperature and 533 K (500 F) following a variety of thermal exposures to obtain load, deflection and failure analysis data.

Freeman, W. T., Jr.↗

JT9D performance deterioration results from a simulated aerodynamic load test

This paper presents the results of testing to identify the effects of simulated aerodynamic flight loads on JT9D engine performance. The test results were also used to refine previous analytical studies on the impact of aerodynamic flight loads on performance losses. To accomplish these objectives, a JT9D-7AH engine was assembled with average production clearances and new seals as well as extensive instrumentation to monitor engine performance, case temperatures, and blade tip clearance changes. A special loading device was designed and constructed to permit application of known moments and shear forces to the engine by the use of cables placed around the flight inlet. The test was conducted in the Pratt and Whitney Aircraft X-Ray Test Facility to permit the use of X-ray techniques in conjunction with laser blade tip proximity probes to monitor important engine clearance changes. Upon completion of the test program, the test engine was disassembled, and the condition of gas path parts and final clearances were documented. The test results indicate that the engine lost 1.1 percent in thrust specific fuel consumption (TSFC), as measured under sea level static conditions, due to increased operating clearances caused by simulated flight loads. This compares with 0.9 percent predicted by the analytical model and previous study efforts.

Stakolich, E. G.↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗