Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Determining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques

Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.

25 ENERGY STORAGE↗

Impact of pulse thermal processing on the properties of inkjet printed metal and flexible sensors

In this paper, we report on the low temperature processing of environmental sensors employing pulse thermal processing (PTP) technique to define a path toward flexible sensor technology on plastic, paper, and fabric substrates. Inkjet printing and pulse thermal processing technique were used to realize mask-less, additive integration of low-cost sensors on polymeric substrates with specific focus on temperature, humidity, and strain sensors. The printed metal line performance was evaluated in terms of the electrical conductivity characteristics as a function of post-deposition thermal processing conditions. The PTP processed Ag metal lines exhibited high conductivity with metal sheet resistance values below 100 mΩ/{whitesquare} using a pulse width as short as 250 μs. The flexible temperature and relative humidity sensors were defined on flexible polyimide substrates by direct printing of Ag metal structures. The printed resistive temperature sensor and capacitive humidity sensor were characterized for their sensitivity with focus on future smart-building applications. Strain gauges were printed on polyimide substrate to determine the mechanical properties of the silver nanoparticle films. Finally, the observed electrical properties of the printed metal lines and the sensitivity of the flexible sensors show promise for the realization of a high performance print-on-demand technology exploiting low thermal-budget PTP technique.

36 MATERIALS SCIENCE↗

Cerium migration during PEM fuel cell accelerated stress testing

Cerium is a radical scavenger which improves polymer electrolyte membrane (PEM) fuel cell durability. During operation, however, cerium rapidly migrates in the PEM and into the catalyst layers (CLs). In this work, membrane electrode assemblies (MEAs) were subjected to accelerated stress tests (ASTs) under different humidity conditions. Cerium migration was characterized in the MEAs after ASTs using X-ray fluorescence. During fully humidified operation, water flux from cell inlet to outlet generated in-plane cerium gradients. Conversely, cerium profiles were flat during low humidity operation, where in-plane water flux was negligible, however, migration from the PEM into the CLs was enhanced. Humidity cycling resulted in both in-plane cerium gradients due to water flux during the hydration component of the cycle, and significant migration into the CLs. Fluoride and cerium emissions into effluent cell waters were measured during ASTs and correlated, which signifies that ionomer degradation products serve as possible counter-ions for cerium emissions. Fluoride emission rates were also correlated to final PEM cerium contents, which indicates that PEM degradation and cerium migration are coupled. Lastly, it is proposed that cerium migrates from the PEM due to humidification conditions and degradation, and is subsequently stabilized in the CLs by carbon catalyst supports.

30 DIRECT ENERGY CONVERSION↗

Effects of Variations in Salt-Spray Conditions on the Corrosion Mechanisms of an AE44 Magnesium Alloy

The understanding of how corrosion affects magnesium alloys is of utmost importance as the automotive and aerospace industries have become interested in the use of these lightweight alloys. However, the standardized salt-spray test does not produce adequate corrosion results when compared with field data, due to the lack of multiple exposure environments. This research explored four test combinations through three sets of cycles to determine how the corrosion mechanisms of pitting, intergranular corrosion, and general corrosion were affected by the environment. Of the four test combinations, Humidity-Drying was the least corrosive, while the most corrosive test condition was Salt Spray-Humidity-Drying. The differences in corrosivity of the test conditions are due to the various reactions needed to cause corrosion, including the presence of chloride ions to cause pit nucleation, the presence of humidity to cause galvanic corrosion, and the drying phase which trapped chloride ions beneath the corrosion by-products.

Martin, Holly J.↗

Clausius–Clapeyron Scaling of CAPE from Analytical Solutions to RCE

By deriving analytical solutions to radiative-convective equilibrium (RCE), it is shown mathematically that convective available potential energy (CAPE) exhibits Clausius-Clapeyron (CC) scaling over a wide range of surface temperatures up to 310 K. Above 310 K, CAPE deviates from CC scaling and even decreases with warming at very high surface temperatures. At the surface temperature of the current tropics, the analytical solutions predict that CAPE increases at a rate of about 6%-7% per kelvin of surface warming. The analytical solutions also provide insight on how the tropopause height and stratospheric humidity change with warming. Changes in the tropopause height exhibit CC scaling, with the tropopause rising by about 400 m per kelvin of surface warming at current tropical temperatures and by about 1-2 km K -1 at surface temperatures in the range of 320-340 K. The specific humidity of the stratosphere exhibits super-CC scaling at temperatures moderately warmer than the current tropics. With a surface temperature of the current tropics, the stratospheric specific humidity increases by about 6% per kelvin of surface warming, but the rate of increase is as high as 30% K -1 at warmer surface temperatures.

58 GEOSCIENCES↗

The Role of Multiscale Interaction in Tropical Cyclogenesis and Its Predictability in Near-Global Aquaplanet Cloud-Resolving Simulations

Tropical cyclogenesis (TCG) is a multiscale process that involves interactions between large-scale circulation and small-scale convection. A near-global aquaplanet cloud-resolving model (NGAqua) with 4-km horizontal grid spacing that produces tropical cyclones (TCs) is used to investigate TCG and its predictability. This study analyzes an ensemble of three 20-day NGAqua simulations, with initial white-noise perturbations of low-level humidity. TCs develop spontaneously from the northern edge of the intertropical convergence zone (ITCZ), where large-scale flows and tropical convection provide necessary conditions for barotropic instability. Zonal bands of positive low-level absolute vorticity organize into cyclonic vortices, some of which develop into TCs. A new algorithm is developed to track the cyclonic vortices. A vortex-following framework analysis of the low-level vorticity budget shows that vertical stretching of absolute vorticity due to convective heating contributes positively to the vorticity spinup of the TCs. A case study and composite analyses suggest that sufficient humidity is key for convective development. TCG in these three NGAqua simulations undergoes the same series of interactions. The locations of cyclonic vortices are broadly predetermined by planetary-scale circulation and humidity patterns associated with ITCZ breakdown, which are predictable up to 10 days. Whether and when the cyclonic vortices become TCs depend on the somewhat more random feedback between convection and vorticity.

54 ENVIRONMENTAL SCIENCES↗

Environmental controls on simulated deep moist convection initiation occurring during RELAMPAGO-CACTI

This study synthesizes the results of 13 high-resolution simulations of deep convective updrafts forming over idealized terrain using environments observed during the RELAMPAGO and CACTI field projects. Using composite soundings from multiple observed cases, and variations upon them, we explore the sensitivity of updraft properties (e.g., size, buoyancy, and vertical pressure gradient forces) to influences of environmental relative humidity, wind shear, and mesoscale orographic forcing that support or suppress deep convection initiation (CI). Emphasis is placed on differentiating physical processes affecting the development of updrafts (e.g., entrainment-driven dilution of updrafts) in environments typifying observed successful and null (i.e., no CI despite affirmative operational forecasts) CI events. Thermally-induced mesoscale orographic lift favors the production of deep updrafts originating from ~1–2-km-wide boundary layer thermals. Simulations without terrain forcing required much larger ( ~5-km-wide) thermals to yield precipitating convection. CI outcome was quite sensitive to environmental relative humidity; updrafts with increased buoyancy, depth, and intensity thrived in otherwise inhospitable environments by simply increasing the free tropospheric relative humidity. This implicates the entrainment of free-tropospheric air into updrafts as a prominent governor of CI, consistent with previous studies. Sensitivity of CI to the environmental wind is manifested by: 1) low-level flow affecting the strength and depth of mesoscale convergence along the terrain, and 2) clouds encountering updraft-suppressing pressure gradient forces while interacting with vertical wind shear in the free-troposphere. Among the ensemble of thermals occurring in each simulation, the widest deep updrafts in each simulation were the most sensitive to environmental influences.

54 ENVIRONMENTAL SCIENCES↗

Droplet Growth or Evaporation Does Not Buffer the Variability in Supersaturation in Clean Clouds

Abstract Water vapor supersaturation in clouds is a random variable that drives activation and growth of cloud droplets. The Pi Convection–Cloud Chamber generates a turbulent cloud with a microphysical steady state that can be varied from clean to polluted by adjusting the aerosol injection rate. The supersaturation distribution and its moments, e.g., mean and variance, are investigated for varying cloud microphysical conditions. High-speed and collocated Eulerian measurements of temperature and water vapor concentration are combined to obtain the temporally resolved supersaturation distribution. This allows quantification of the contributions of variances and covariances between water vapor and temperature. Results are consistent with expectations for a convection chamber, with strong correlation between water vapor and temperature; departures from ideal behavior can be explained as resulting from dry regions on the warm boundary, analogous to entrainment. The saturation ratio distribution is measured under conditions that show monotonic increase of liquid water content and decrease of mean droplet diameter with increasing aerosol injection rate. The change in liquid water content is proportional to the change in water vapor concentration between no-cloud and cloudy conditions. Variability in the supersaturation remains even after cloud droplets are formed, and no significant buffering is observed. Results are interpreted in terms of a cloud microphysical Damköhler number (Da), under conditions corresponding to , i.e., the slow-microphysics regime. This implies that clouds with very clean regions, such that is satisfied, will experience supersaturation fluctuations without them being buffered by cloud droplet growth. Significance Statement The saturation ratio (humidity) in clouds controls the growth rate and formation of cloud droplets. When air in a turbulent cloud mixes, the humidity varies in space and time throughout the cloud. This is important because it means cloud droplets experience different growth histories, thereby resulting in broader size distributions. It is often assumed that growth and evaporation of cloud droplets buffers out some of the humidity variations. Measuring these variations has been difficult, especially in the field. The purpose of this study is to measure the saturation ratio distribution in clouds with a range of conditions. We measure the in-cloud saturation ratio using a convection cloud chamber with clean to polluted cloud properties. We found in clouds with low concentrations of droplets that the variations in the saturation ratio are not suppressed.

54 ENVIRONMENTAL SCIENCES↗

Deep Convection Initiation, Growth, and Environments in the Complex Terrain of Central Argentina during CACTI

This study characterizes the wide range of deep convective cloud life cycles and their relationships with ambient environments observed during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign near the Sierras de Córdoba (SDC) range in central Argentina. We develop a novel convective cell tracking database for the entire field campaign using C-band polarimetric radar observations. The cell tracking database includes timing, location, area, depth, merge/split information, microphysical properties, collocated satellite-retrieved cloud properties, and sounding-derived environmental conditions. Results show that the SDC exerts a strong control on convection initiation (CI) and growth. CI preferentially occurs east of the SDC ridge during the afternoon, and cells often undergo upscale growth through the evening as they travel eastward toward the plains. Larger and more intense cells tend to occur in more unstable and humid low-level environments, and surface-based cells are stronger than elevated cells. Midtropospheric relative humidity and vertical wind shear also jointly affect the size and depth of the cells. Rapid cell area growth rates exhibit dependence on both large environmental wind shear and low-level moisture. Evolution of convective cell macro- and microphysical properties are strongly influenced by convective available potential energy and low-level humidity, as well as the presence of other cells in their vicinity. This cell tracking database demonstrates a framework that ties measurements from various platforms centering around convective life cycles to facilitate process understanding of factors that control convective evolution.

54 ENVIRONMENTAL SCIENCES↗

Modeling the Evolution and Life Cycle of Stable Cold Pools

Stable cold pools in California’s Central Valley (CV) are conducive to freezing temperatures, high relative humidity, and, in some cases, fog. Here, it will be shown that the Weather Research and Forecasting (WRF) Model as commonly configured cannot reproduce such conditions because of a persistent warm and dry bias near the surface. It was discovered that removing horizontal diffusion, which by default operates on model levels and thus up and down the valley’s sides, can reduce but not entirely fix the problem. Further improvements include enhancing the near-surface vertical resolution and the surface–air coupling, as both directly control the surface fluxes, especially evaporation. Yet, these alterations actually have the largest impact in the forested region surrounding the Central Valley, and influence the nighttime relative humidity in the CV only indirectly via nocturnal drainage flows. While it is not clear how realistic are the increased evaporation in the forest or the drainage flows, how and why these alterations result in significantly improved relative humidity reconstructions within the Central Valley are shown.

54 ENVIRONMENTAL SCIENCES↗

SRNL SHELF LIFE STUDIES - SCC STUDIES AT ROOM TEMPERTURE [stress corrosion cracking ]

Phase II, Series 2 corrosion testing performed by the Savannah River National Laboratory (SRNL) for the Department of Energy 3013 container has been completed. The corrosion tests are part of an integrated plan conducted jointly by Los Alamos National Laboratory and the Savannah River Site. SRNL was responsible for conducting corrosion studies in small-scale vessels to address the influence of salt composition, water loading, and type of oxide/salt contact on the relative humidity inside a 3013 container and on the resulting corrosion of Type 304L and 316L stainless steel (304L and 316L). This testing was conducted in two phases: Phase I evaluated a broad spectrum of salt compositions and initial water loadings on the salt mixtures exposed to 304L and 316L and the resulting corrosion; Phase II evaluated the corrosion of 304L at specific water loadings and a single salt composition. During Phase I testing at high initial moisture levels (0.35 to 1.24 wt%)a, the roomtemperature corrosion of 304L exposed to a series of plutonium oxide/chloride salt mixtures ranged from superficial staining to pitting and stress corrosion cracking (SCC). 304L teardrop coupons that exhibited SCC were directly exposed to a mixture composed of 98 wt % PuO2, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl2. Cracking was not observed in a 316L teardrop coupon. Pitting was also observed in this environment for both 304L and 316L with depths ranging from 20 to 100 μm. Neither pitting nor SCC was observed in mixtures with a greater chloride salt concentration (5 and 28 wt%). These results demonstrated that for a corrosive solution to form a balance existed between the water loading and the salt chloride concentration. This chloride solution results from the interaction of loaded water with the hydrating CaCl2 salt. In Phase II, Series 1 tests, the SCC results were shown to be reproducible with cracking occurring in as little as 85 days. The approximate 0.5 wt% moisture level was found to result in an initial relative humidity of ~55% within the small-scale vessels. Pits were found to be associated with cracks and appeared to act as initiators for the cracking. In a vapor-space only exposure, the weld oxide, which results from the TIG closure weld used to fabricate the teardrop coupon, was also shown to be more susceptible to pitting corrosion than a surface free from weld oxide. This result has important implications for the closure weld of the 3013 inner can since the weld oxide on the can internal surface cannot be removed. The results from the Phase II, Series 2 tests further demonstrated the significance of forming a solution with a critical chloride concentration for corrosion to proceed. 304L teardrop coupons were found to corrode only by pitting with a similar oxide/salt mixture as used in Series 1 testing but with a lower water loading of 0.2 wt%, which resulted in an initial relative humidity of 35-38%. These tests ran twice as long as those for Series 1 testing. The exposure condition was also found to impact the corrosion with salt-exposed surfaces showing lower corrosion resistance. Additional analyses of the Series 2 coupons are recommended especially for determining if cracks emanate from the bottom of pits. Data generated under the 2009 3013 corrosion test plan, as was presented here, increased the understanding of the corrosion process within a sealed 3013 container. Along with the corrosion data from destructive evaluations of 3013 containers, the inner can closure weld region (ICCWR) has been identified as the most vulnerable area of the inner can where corrosion may lead to corrosive species leaking to the interior surface of the outer container, thereby jeopardizing the integrity of the 3013 container. A new corrosion plan has been designed that will characterize the corrosion at the ICCWR of 3013 DEs as well as parameters affecting this corrosion.

3013 plutonium storage, stress corrosion cracking,↗

Low-Cost Proton Conducting Membranes for PEM Fuel Cells

Proton exchange membrane (PEM) is the key component in PEM fuel cells that critically determines the system performance and its economic viability. Presently, the state-of-the-art PEMs, such as Nafion membranes, are based on perfluorosulfonic acid (PFSA) ionomers. But these ionomer materials are expensive, particularly at the low volumes that will be needed for initial commercialization. Besides, they are not suitable for fuel cells operated beyond 100°C, because of the limitations connected to the humidification requirement of such membrane materials, limiting the maximum operating temperature to about 90°C. Fuel cells for transportation applications are required to operate in a wide temperature range from –20°C to 120°C. Low-cost PEMs with capabilities in a range of temperature and humidity conditions are urgently needed to meet the DOE fuel cell targets for transportation applications. Amsen Technologies LLC chooses to address the DOE call with a novel reinforced PEM approach based on new, non-PFSA proton conducting ionomers developed from our previous DOE SBIR projects. Along with this approach is the use of very cheap, ultra thin and highly porous microporous polymer meshes as the support for the membrane. The new PEM is expected to have significant cost advantages over traditional PEMs. The microporous polyolefin support costs $2-3/m 2 ; and the new ionomers that Amsen has developed are estimated at ~$\$$250/kg at the higher end including material costs and labor costs (which may go down in the future as the processing is optimized and production scaled up). These have led to an estimate of total material cost for the membrane at $\$$11 to $\$$12/m 2 , offering high potential of meeting the DOE cost targets (≤$\$$20/m 2 ) after adding processing cost and profit margin. The Phase I results have successfully demonstrated that it is very promising to develop the intended low-cost, high-performance PEM membrane. Suitable material system has been identified, and suitable process for forming the new PEM has been developed. Uniform membranes have been reproducibly fabricated. These membranes have been extensively characterized and evaluated in terms of microstructural features, and relevant physical and chemical properties including proton conductivity and area specific proton resistance in a range of temperature and humidity conditions, resistance to electronic conduction, water uptake/swelling, dimensional stability, chemical stability, and mechanical durability. Membrane electrode assemblies (MEA) with the new membrane have been successfully prepared and tested for fuel cell operation. The new PEM showed higher proton conductivity than Nafion membranes for all measurement conditions used in Phase I. With high proton conductivity and ultra-thin thickness (~20 /m), the new membrane showed high promise to met DOE targets for the low ASR. The ASR targets have been met for relatively high RH but not yet for RH ≤ 70%. Further optimization in ionomer chemistry and membrane processing is needed in order to meet the ASR targets for a wide range of temperature and humidity conditions. The new membrane showed fairly high electronic resistance at 1373 ohm cm 2 , meeting the DOE target for electronic resistance (> 1000 ohm cm 2 ). The new membrane also has demonstrated promisingly high chemical stability, high mechanical durability, and high dimensional stability. Fuel cell operation using MEAs with the new membrane have shown the same level of fuel cell performance as MEAs with Nafion membranes. Overall, the new membrane has been demonstrated to have high potential of meeting all DOE performance targets for fuel cell applications as well as the cost targets. The manufacturers of PEM fuel cells, PEM electrolyzers, redox flow batteries, and MEA are the end-users and customers of PEMs. For commercialization purpose and potential partnering relations, we have been talking with many such manufacturers. They have responded with extremely high interest in the new PEM being developed in the present technology. Accomplishments so far have laid down a strong base for Amsen to further the development efforts on this new PEM and to pursue commercialization. The near-term future work will be mainly focused on further development and systematical optimization of the material system, processing, and performance of the new membrane; systematical evaluation of the new membrane in terms of all relevant properties including long-term mechanical, chemical, and combined chemical/mechanical durabilities using DOE specified testing protocols; development of production scale-up scheme; and preparation for commercialization.

08 HYDROGEN↗

Accelerated Aging Test for Plastic Scintillator Gamma Ray Detectors

Polyvinyl toluene (PVT) and polystyrene (PS), collectively referred to as “plastic scintillator,” are synthetic polymer materials used to detect gamma radiation, and are commonly used in instrumentation. Recent studies have revealed that plastic scintillator undergoes an environmentally related material degradation that adversely affects performance under certain conditions and histories. A significant decrease in gamma ray sensitivity has been seen in some detectors in systems as they age. The degradation of sensitivity of plastic scintillator over time is due to a variety of factors, and the term “aging” is used to encompass all factors. Some plastic scintillator samples show no aging effects (no significant change in sensitivity over more than 10 years), while others show severe aging (significant change in sensitivity in less than 5 years). Aging effects arise from weather (variations in heat and humidity), chemical exposure, mechanical stress, light exposure, and loss of volatile components. The damage produced by these various causes can be cumulative, causing observable damage to increase over time. Damage may be reversible up to some point, but becomes permanent under some conditions. It has been demonstrated that exposure of plastic scintillator in an environmental chamber to 30 days of high temperature and humidity (90% relative humidity and 55°C) followed by a single cycle to cold temperature (-30°C) will produce severe fogging in all PVT samples. This thermal cycle will be referred to as the “Accelerated Aging Test.” This document describes the procedure for performing this Accelerated Aging Test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final report for Assembling Microorganisms into Energy Converting Materials

The goal of this project was to integrate microorganisms capable of reversible energy transduction in response to changing relative humidity with non-biological materials to create hybrid energy conversion systems. While plants and many other biological organisms have developed structures that are extraordinarily effective in converting changes in relative humidity into mechanical energy, engineered energy transduction systems rarely take advantage of this powerful phenomenon. Rather than developing synthetic materials that can convert changes in relative humidity in to mechanical energy, we developed approaches to assemble bacterial spores into larger materials. These materials can convert energy from evaporation of water in dry atmospheric conditions, which we demonstrated by building energy harvesters from these materials. We have also developed experiments to investigate the interaction of water with the spore material, and to determine how this interaction imposes limits on energy conversion. In addition, we carried out theoretical calculations to investigate the limits imposed by the environmental conditions to the power available in the energy harvesting process. These calculations took into account heat and water vapor transfer in the atmosphere surrounding the spore based materials. Overall, our results suggest that biomolecular materials are promising candidates to convert energy from evaporation.

36 MATERIALS SCIENCE↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Polyurethane foams are organic materials which can be classified as mechanically rigid or flexible. They are chemically inert, relatively unaffected by the presence of water (cracking, swelling, absorption), and can be manufactured in densities from 3-40 lb/ft 3 . In addition, polyurethane foams have exceptional mechanical and thermal properties, which support use of polyurethane foams in the 9977 shipping packages. These packages are designed for shipment of special nuclear material and are approved for storage in the K-area complex (KAC) at Savannah River Site. Through the analysis of conditioned foams, a service life ofFR-3700 can be estimated for the storage of the 9977 packages. Thus, considering anticipated temperatures of the 9977 packages in the KAC, FR-3700 was conditioned at 160°F, 185°F, 215°F, 250°F, and 160°F with 50% relative humidity, which remains within the service temperature of-320°F - 250°F of the FR-3700 foam in the 9977 packages. Prior studies have analyzed foams after 7, 20, and 30 months of conditioning with the current study analyzing foams up to 55 months of conditioning. Considering the limited information on the effects of radiation on FR-3700, samples were irradiated with a cobalt-60 source at a high and low dose rate of 90.9 krad/hr and 16.67 krad/hr, respectively, to examine the effects of irradiation and dose rate on thermal properties. It was found that foams conditioned up to 55 months had comparable heat capacity values to FR-3700, with a slight increase due to humidity. Results suggest that fire additives began decomposing at higher conditioning temperatures, reducing the average percent mass loss. Overall, irradiation and humidity had minimal effects on thermal properties of FR-3700.

36 MATERIALS SCIENCE↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2019

Desert Research Institute (DRI) conducted a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) because of storm runoff. This activity supported U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work was intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collected air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters were recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station were also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2019. During the FY2019 reporting period, the warmest months were June, July, and August and the coldest were December and February. The highest monthly solar radiation (i.e., sunshine) values were recorded in June, July, and August, whereas December through February had the lowest solar radiation values. Monthly mean wind speeds were highest in the spring (April) and early summer (June). Winds were predominantly from the north, except in February, July, August, and September when winds were mostly from the west. The monthly average relative humidity ranged from 17 percent to approximately 60 percent. Humidity was lowest in the summer and highest in the winter. Monthly total precipitation ranged from 0.0 during August and September to 2.22 inches (in) (56.39 millimeters [mm]) in February. Total precipitation for FY2019 was 7.83 in (198.88 mm). During the reporting period, a single, nonzero, flow event was recorded at the flume. This occurred over two days between March 6 and 7, 2019, in response to 1.16 in (29.46 mm) of precipitation falling within 9.3 hours on March 6, 2019. This event produced a peak water depth of 0.39 in (0.99 centimeters [cm]) in the flume, and runoff was measured for approximately 23.5 hours. However, the maximum recorded flow depth was less than the limit for flow discharge and velocity that can be calculated for the six-inch (15 cm) throat of a Parshall flume. The runoff event produced insufficient flow velocities through the natural channel to cause local erosion and transport of bedload materials. No bedload samples were collected for radiological analysis. Observing meteorological and environmental conditions that lead to storm runoff will help identify the parameters and threshold conditions that should be incorporated into post-closure monitoring plans for this and similar Soils CAU sites. Routine monitoring of meteorological and hydrologic parameters at the Smoky Site CA has been discontinued at the request of EM NV, effective at the conclusion of FY2019. Environmental data acquisition was completed and the meteorological and runoff monitoring stations were removed from the Smoky Site on October 15, 2019.

54 ENVIRONMENTAL SCIENCES↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predictive Models and Novel Accelerated Tests for the Reliability of Cell Metallization in Photovoltaic Modules (Final Report)

Studies of metallization corrosion m photovoltaics have mainly been limited to comparisons of modules placed in accelerated chambers to fielded modules [1]. Damp Heat accelerated tests and phenomenological equations [2] are used to assess metallization corrosion without understanding the effect of UV light and temperature and humidity cycles on encapsulant adhesion degradation. The roles of encapsulant in-and out-diffusions of moisture and encapsulant impurities are important. Furthermore, few photovoltaic metallization corrosion studies included the role of bias and leakage currents, which are crucial in the electrochemical reaction of metallization. Leakage currents can highly accelerate the corrosion mechanism and are important to include in the studies of corrosion. In our research plan, we will address the following gaps in the PV community's understanding of metallization corrosion: (1) metallization corrosion with bias, humidity, and impurities in the encapsulant or metallization; (2) humidity diffusion through fresh and degraded encapsulants; and (3) comparison of model predictions with outdoor field modules and SunPower's extensive data for its back-contact and front-contact fleets [2] along with NREL's store of >20 year old modules. Our goal is to build models and accelerated tests to predict long term degradation of metallization corrosion of photovoltaic modules in the field. Our studies will include metals used in c-Si solar cells (Cu, Ag, and Al) and commonly used encapsulants (EV A (ethylene vinyl acetate), TPO (thermoplastic olefin), and silicone).

14 SOLAR ENERGY↗