Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

SU-F-T-229: A Novel Method for EPID-Based In-Vivo Exit Dose Verification for Intensity Modulated Radiotherapy

Purpose: Electronic portal imaging device (EPID) can be used to acquire a two-dimensional exit dose distribution during treatment delivery, thus allowing the in-vivo verification of the dose delivery through a comparison of measured portal images to predicted portal dose images (PDI). The aim of this study was to present a novel method to easily and accurately predict PDI, and to establish an EPID-based in-vivo dose verification method during IMRT treatments. Methods: We developed a model to determine the predicted portal dose at the same plane of the EPID detector location. The Varian EPID (aS1000) positions at 150cm source-to-detector-distance (SDD), and can be used to acquire in-vivo exit dose using Portal Dosimetry (PD) function. Our model was generated to make an equivalent water thickness represent the buildup plate of EPID. The exit dose at extend SDD plane with patient CT data in the beam can be calculated as the predicted PDI in the treatment planning system (TPS). After that, the PDI was converted to the fluence at SDD of 150cm using the inverse square law coded in MATLAB. Five head-and-neck and prostate IMRT patient plans contain 32 fields were investigated to evaluate the feasibility of this new method. The measured EPID image was compared with PDI using the gamma analysis. Results: The average results for cumulative dose comparison were 81.9% and 91.6% for 3%, 3mm and 4%, 4mm gamma criteria, respectively. Results indicate that the patient transit dosimetry predicted algorithm compares well with EPID measured PD doses for test situations. Conclusion: Our new method can be used as an easy and feasible tool for online EPID-based in-vivo dose delivery verification for IMRT treatments. It can be implemented for fast detecting those obvious treatment delivery errors for individual field and patient quality assurance.

60 APPLIED LIFE SCIENCES↗

Validation of SAS4A/SASSYS-1 for Steady-State Single-Phase Natural Circulation

The development of numerical software for engineering applications requires the validation of the code against experimental benchmark datasets. To support the validation of SAS4A/SASSYS-1 in simulating the single-phase natural circulation within nuclear reactor systems, high-precision steady-state experiments are performed to capture single-phase natural circulation phenomena on an existing scaled facility with comprehensive instrumentation. Forced convection tests are designed precisely capturing the facility’s critical thermal-hydraulic parameters required for one-dimensional modeling, and a comprehensive single-phase natural circulation dataset is obtained with well-documented experimental uncertainty and facility description. Analysis and discussion based on the finalized dataset confirm the dataset’s ability in capturing dominant phenomena and address important physical interpretation of parameters. The dataset reported in this project provides a valuable benchmark resource for the validation of system analysis codes under single-phase natural circulation inside nuclear reactors. Validation of SAS4A/SASSYS-1 is then performed against the obtained benchmark dataset to confirm the capability of its physics model in simulating the steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators to quantify and restrict numerical errors from discretization. Numerical uncertainty originating from finite maximum pseudo-transient time is also quantified and restricted. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, directly quantifying the simulation output in a Monte Carlo approach. The composition of the output uncertainty is further determined by the estimators of Sobol’ indices through a variance-based sensitivity analysis. With uncertainty quantified for each individual condition, detailed comparison between the simulation results and experimental data is performed covering the whole dataset, which shows consistent agreement for all important quantities. The validation activity reported in this project demonstrates that SAS4A/SASSYS-1 can predict the primary parameters with satisfactorily accuracy under steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Design Method for Low-Pressure Venturi Nozzles

The purpose of this work is to provide empirical design models for low-pressure, subsonic Venturi nozzles. Experimentally validated simulations were used to determine the effect of nozzle geometry and operating conditions on the suction ratio (ratio of suction mass flow rate to motive mass flow rate) of low-pressure, subsonic Venturi nozzles, over a wide range of geometries and operating conditions, through a parametric study. The results of the parametric study were used to develop seven empirical models, each with a different range of applicability or calculating a different indicator of nozzle performance (i.e., suction ratio, momentum ratio, or dynamic pressure ratio), of the Venturi nozzles using a constrained multi-variable global optimization method. Of the seven empirical models, the best models were found to be those for low- (less than one) and high-suction ratios (greater than one), with mean absolute percentage errors of 5% and 18%, respectively. These empirical models provide a design tool for subsonic, low-pressure Venturi nozzles that is more than an order of magnitude more accurate than a governing equation approach or conventional flow head calculations. These newly-developed empirical models can be applied for initial nozzle design when precise suction ratios are required.

O’Hern, Hannah↗

Reliable detection of fluence anomalies in EPID-based IMRT pretreatment quality assurance using pixel intensity deviations

Purpose: This work uses repeat images of intensity modulated radiation therapy (IMRT) fields to quantify fluence anomalies (i.e., delivery errors) that can be reliably detected in electronic portal images used for IMRT pretreatment quality assurance. Methods: Repeat images of 11 clinical IMRT fields are acquired on a Varian Trilogy linear accelerator at energies of 6 MV and 18 MV. Acquired images are corrected for output variations and registered to minimize the impact of linear accelerator and electronic portal imaging device (EPID) positioning deviations. Detection studies are performed in which rectangular anomalies of various sizes are inserted into the images. The performance of detection strategies based on pixel intensity deviations (PIDs) and gamma indices is evaluated using receiver operating characteristic analysis. Results: Residual differences between registered images are due to interfraction positional deviations of jaws and multileaf collimator leaves, plus imager noise. Positional deviations produce large intensity differences that degrade anomaly detection. Gradient effects are suppressed in PIDs using gradient scaling. Background noise is suppressed using median filtering. In the majority of images, PID-based detection strategies can reliably detect fluence anomalies of {>=}5% in {approx}1 mm{sup 2} areas and {>=}2% in {approx}20 mm{sup 2} areas. Conclusions: The ability to detect small dose differences ({<=}2%) depends strongly on the level of background noise. This in turn depends on the accuracy of image registration, the quality of the reference image, and field properties. The longer term aim of this work is to develop accurate and reliable methods of detecting IMRT delivery errors and variations. The ability to resolve small anomalies will allow the accuracy of advanced treatment techniques, such as image guided, adaptive, and arc therapies, to be quantified.

60 APPLIED LIFE SCIENCES↗

Effect of cylindrical confinement on the determination of laminar flame speeds using outwardly propagating flames

The effect of nonspherical (i.e. cylindrical) bomb geometry on the evolution of outwardly propagating flames and the determination of laminar flame speeds using the conventional constant-pressure technique is investigated experimentally and theoretically. The cylindrical chamber boundary modifies the propagation rate through the interaction of the wall with the flow induced by thermal expansion across the flame (even with constant pressure), which leads to significant distortion of the flame surface for large flame radii. These departures from the unconfined case, especially the resulting nonzero burned gas velocities, can lead to significant errors in flame speeds calculated using the conventional assumptions, especially for large flame radii. For example, at a flame radius of 0.5 times the wall radius, the flame speed calculated neglecting confinement effects can be low by {proportional_to}15% (even with constant pressure). A methodology to estimate the effect of nonzero burned gas velocities on the measured flame speed in cylindrical chambers is presented. Modeling and experiments indicate that the effect of confinement can be neglected for flame radii less than 0.3 times the wall radius while still achieving acceptable accuracy (within 3%). The methodology is applied to correct the flame speed for nonzero burned gas speeds, in order to extend the range of flame radii useful for flame speed measurements. Under the proposed scaling, the burned gas speed can be well approximated as a function of only flame radius for a given chamber geometry - i.e. the correction function need only be determined once for an apparatus and then it can be used for any mixture. Results indicate that the flow correction can be used to extract flame speeds for flame radii up to 0.5 times the wall radius with somewhat larger, yet still acceptable uncertainties for the cases studied. Flow-corrected burning velocities are measured for hydrogen and syngas mixtures at atmospheric and elevated pressures. Flow-corrected flame speeds in the small cylindrical chamber used here agree well with previously reported flame speeds from large spherical chambers. Previous papers presenting burning velocities from cylindrical chambers report performing data analysis on flame radii less than 0.5 or 0.6 times the wall radius, where the flame speed calculated neglecting confinement effects may be low by {proportional_to}15 or 20%, respectively. For cylindrical chambers, data analysis should be restricted to flame radii less than 0.3 times the wall radius or a flow correction should be employed to account for the burned gas motions. With regard to the design of future vessels, larger vessels that minimize the flow aberrations for the same flame radius are preferred. Larger vessels maximize the relatively unaffected region of data allowing for a more straightforward approach to interpret the experimental data. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INSTRUMENT PERFORMANCE IN KEPLER's FIRST MONTHS

The Kepler Mission relies on precise differential photometry to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on timescales up to {approx}2 days and systematic error removal to better than 20 ppm. To this end, the spacecraft and photometer underwent 67 days of commissioning, which included several data sets taken to characterize the photometer performance. Because Kepler has no shutter, we took a series of dark images prior to the dust cover ejection, from which we measured the bias levels, dark current, and read noise. These basic detector properties are essentially unchanged from ground-based tests, indicating that the photometer is working as expected. Several image artifacts have proven more complex than when observed during ground testing, as a result of their interactions with starlight and the greater thermal stability in flight, which causes the temperature-dependent artifact variations to be on the timescales of transits. Because of Kepler's unprecedented sensitivity and stability, we have also seen several unexpected systematics that affect photometric precision. We are using the first 43 days of science data to characterize these effects and to develop detection and mitigation methods that will be implemented in the calibration pipeline. Based on early testing, we expect to attain Kepler's planned photometric precision over 80%-90% of the field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INITIAL CHARACTERISTICS OF KEPLER LONG CADENCE DATA FOR DETECTING TRANSITING PLANETS

The Kepler Mission seeks to detect Earth-size planets transiting solar-like stars in its {approx}115 deg{sup 2} field of view over the course of its 3.5 year primary mission by monitoring the brightness of each of {approx}156,000 Long Cadence stellar targets with a time resolution of 29.4 minutes. We discuss the photometric precision achieved on timescales relevant to transit detection for data obtained in the 33.5 day long Quarter 1 (Q1) observations that ended 2009 June 15. The lower envelope of the photometric precision obtained at various timescales is consistent with expected random noise sources, indicating that Kepler has the capability to fulfill its mission. The Kepler light curves exhibit high precision over a large dynamic range, which will surely permit their use for a large variety of investigations in addition to finding and characterizing planets. We discuss the temporal characteristics of both the raw flux time series and the systematic error-corrected flux time series produced by the Kepler Science Pipeline, and give examples illustrating Kepler's large dynamic range and the variety of light curves obtained from the Q1 observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Fluid Dynamics Effects on Microstructure Prediction in Single Laser Tracks for Additive Manufacturing

The Laser Powder Bed Fusion Additive Manufacturing (LPBFAM) is one of the most important processes for the production of lightweight, cost-effective, complex, and high-performance enduse parts. At present, the cost and time associated with LPBFAM process development is very high due to a lack of fundamental process understanding. In this project, a multi-physics model was developed on a highly parallel open-source code, Truchas, with the ultimate goal of providing experimentally validated process maps for tailoring microstructure to achieve desired performance for LPBFAM. As a critical step towards fully LPBFAM modeling, modeling of single-track laser fusion (STLF) were conducted. Multi-physics simulations were conducted using Truchas for STLF by considering heat transfer, phase-change, fluid dynamics, surface tension phenomena, and evaporation. In order to assess the effect of the fluid dynamics on the solidification and ensuing microstructure, a heat transfer-and-solidification-only (HTS) model and a fully coupled heat-transfer-solidification and fluid-dynamics (HTS-FD) model were considered. In the HTS_FD model, the fluid flow was considered to be laminar while the molten alloy surface is assumed to be flat and non-deformable. This study is one the first attempt to understand the effect of the fluid flow on microstructure in STLF and LPBFAM. The results show that the fluid flow affects the solidification and ensuing microstructure in STLF. In order to validate Truchas for STLF and LPBFAM modeling, experimental data, which was obtained at GE Global Research (GEGR) for liquid pool shape and microstructure, were compared with those from numerical simulation results. For the keyhole regime case, numerical simulation results indicate that the melt-pool shape was typical to that of the conduction case with very large deviations from the measured melt-pool depths. Two sensitivity studies were conducted by varying the evaporation flux and the surface tension coefficient at fixed laser absorptivities of 0.5 and 0.3, respectively. The minimum value for the overall combined error, between the calculated values with the HTS_FD model and measured values for both the width and height of the melt-pool, was attained for a surface tension coefficient of -0.75e-4 N/m. An analytical solidification model for the columnar-to-equiaxed transition (CET) in rapid solidification was used to assess the microstructure variation within the melt-pool. From numerical simulation results, thermal gradient, G, and solidification velocity, V, were obtained in order to predict the microstructure type (e.g., dendritic, cellular). For the fluid-flow HTS_FD model, G was found to exhibit a maximum at the extremity of the solidified pool (i.e., at the free surface). By contrast, for HTS simulations, G was found to exhibit a maximum around the entire edge of the solidified pool. For the HTS_FD simulations, the minimum values of the cooling rate, GV, were found to be approximately half than their corresponding values for HTS simulations. By contrast with the min GV values, the maximum values for GV were found to occur for the HTS_FD simulations. Thus, HTS_FD simulations were found to exhibit a wider range of cooling rates than the HTS simulations. Concerning the solidification maps, the variation of the solidification velocity, V, as function of the thermal gradient, G, was obtained. It was found that the fluid flow model results (HTS_FD) exhibited an increased spread in the V(G) variation within the melt pool with respect to the HTS model results (without the fluid flow). A preliminary correlation model for the primary dendrite arm spacing (PDAS) based on a power law dependence on thermal gradient and solidification velocity was used to estimate PDAS from HTS and HTS_FD simulations. For low laser powers and low laser speeds, the PDAS obtained 6 with the fluid dynamics model (HTS_FD) was larger by more than 30% with respect to the PDAS calculated with the simple HTS model. In the second part of the project, fifty-seven simulations were conducted in order to obtain data on microstructure variables that can be used for process map development. In order to cover the entire processing space, thirty-three cases were selected STLF process simulations at six power levels and six laser scanning speeds. The 57 STLF process simulations were conducted as follows: 33 simulations with the heat-transfer-only (HTS) model and 24 simulations with the fluid flow model (HTS_FD). The solidification map data shows that for all simulations, a columnar dendritic microstructure would be expected. It was found that the minimum, average, and maximum thermal gradient exhibit exponential variations with respect to a process variable defined as the ratio between the power and square root of scan speed.

36 MATERIALS SCIENCE↗

Soil-related developments of the Biome-BGCMuSo v6.2 terrestrial ecosystem model

Terrestrial biogeochemical models are essential tools to quantify climate–carbon cycle feedback and plant–soil relations from local to global scale. In this study, a theoretical basis is provided for the latest version of the Biome-BGCMuSo biogeochemical model (version 6.2). Biome-BGCMuSo is a branch of the original Biome-BGC model with a large number of developments and structural changes. Earlier model versions performed poorly in terms of soil water content (SWC) dynamics in different environments. Moreover, lack of detailed nitrogen cycle representation was a major limitation of the model. Since problems associated with these internal drivers might influence the final results and parameter estimation, additional structural improvements were necessary. In this paper the improved soil hydrology as well as the soil carbon and nitrogen cycle calculation methods are described in detail. Capabilities of the Biome-BGCMuSo v6.2 model are demonstrated via case studies focusing on soil hydrology, soil nitrogen cycle, and soil organic carbon content estimation. Soil-hydrology-related results are compared to observation data from an experimental lysimeter station. The results indicate improved performance for Biome-BGCMuSo v6.2 compared to v4.0 (explained variance increased from 0.121 to 0.8 for SWC and from 0.084 to 0.46 for soil evaporation; bias changed from -0.047 to -0.007 m 3 m -3 for SWC and from -0.68 to -0.2 mm d -1 for soil evaporation). Simulations related to nitrogen balance and soil CO 2 efflux were evaluated based on observations made in a long-term field experiment under crop rotation. The results indicated that the model is able to provide realistic nitrate content estimation for the topsoil. Soil nitrous oxide (N 2 O) efflux and soil respiration simulations were also realistic, with overall correspondence with the observations (for the N 2 O efflux simulation bias was between -0.13 and -0.1 mgNm -2 d -1 , and normalized root mean squared error (NRMSE) was 32.4 %–37.6 %; for CO 2 efflux simulations bias was 0.04–0.17 gCm -2 d -1 , while NRMSE was 34.1 %–40.1 %). Sensitivity analysis and optimization of the decomposition scheme are presented to support practical application of the model. The improved version of Biome-BGCMuSo has the ability to provide more realistic soil hydrology representation as well as nitrification and denitrification process estimation, which represents a major milestone.

58 GEOSCIENCES↗

Investigation of boundary-layer wind predictions during nocturnal low-level jet events using the Weather Research and Forecasting model

Simulations of two periods featuring three consecutive low level jet (LLJ) events in the US Upper Great Plains during the autumn of 2011 were conducted to explore the impacts of various setup configurations and physical process models on simulated flow parameters within the lowest 200 m above the surface, using the Weather Research and Forecasting (WRF) model. Sensitivities of simulated flow parameters to the horizontal and vertical grid spacing, planetary boundary layer (PBL) and land surface model (LSM) physics options, were assessed. Data from a Light Detection and Ranging (lidar) system, deployed to the Weather Forecast Improvement Project (WFIP; Finley et al. 2013) were used to evaluate the accuracy of simulated wind speed and direction at 80 m above the surface, as well as their vertical distributions between 120 and 40 m, covering the typical span of contemporary tall wind turbines. All of the simulations qualitatively captured the overall diurnal cycle of wind speed and stratification, producing LLJs during each overnight period, however large discrepancies occurred at certain times for each simulation in relation to the observations. 54-member ensembles encompassing changes of the above discussed configuration parameters displayed a wide range of simulated vertical distributions of wind speed and direction, and potential temperature, reflecting highly variable representations of stratification during the weakly stable overnight conditions. Root mean square error (RMSE) statistics show that different ensemble members performed better and worse in various simulated parameters at different times, with no clearly superior configuration . Simulations using a PBL parameterization designed specifically for the stable conditions investigated herein provided superior overall simulations of wind speed at 80 m, demonstrating the efficacy of targeting improvements of physical process models in areas of known deficiencies. However, the considerable magnitudes of the RMSE values of even the best performing simulations indicate ample opportunities for further improvements.

Mirocha, Jeff D.↗

Studying drought-induced forest mortality using high spatiotemporal resolution evapotranspiration data from thermal satellite imaging

Drought can have pervasive and wide-spread impacts to forest health, as evidenced in several severe events occurring over the recent decades. Extensive forest die-off due to drought can impair the ecological functioning of forests, impacting habitat, water yield and quality from forested lands, and altering forest fire dynamics and intensity. Satellite remote sensing provides an effective means for detecting and monitoring spatial patterns of forest mortality over large areas, exploiting free and open long-term image archives available at a range in spatial and temporal resolutions. While remotely sensed surface reflectances and vegetation indices have been widely used to study optical response of forest canopies to drought events, retrievals of evapotranspiration (ET) derived from thermal satellite imagery – particularly at resolutions approaching crown scale - can provide insights into cumulative tree stresses that can incite disease and trigger mortality. In this study, we applied a multi-sensor satellite data fusion approach to estimate daily 30-m resolution ET and an associated Evaporative Stress Index (ESI) to study drought-induced mortality in a temperate forest at the Missouri Ozark AmeriFlux (MOFLUX) site, located in the central United States. The study covered the period from 2010 to 2014, including an exceptional drought year of 2012. Modeled ET agreed well with eddy flux measurements from the MOFLUX tower, with average monthly relative errors of 15%. Plot-scale ESI, describing temporal anomalies in the ratio of actual-to-reference ET, was used as an index of relative forest health to investigate relationships between forest mortality and drought severity. ESI showed good agreement with observed predawn leaf water potential, especially during the drought year. Furthermore, plot-scale ESI was also correlated with the subsequent year's tree mortality, suggesting the importance of considering the forest health condition prior to drought when studying drought-induced forest impacts. This study demonstrates the utility of multi-year ET remote sensing data at the stand or plot scale as an indicator of forest health and as a predictor of future mortality due to drought.

54 ENVIRONMENTAL SCIENCES↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗

Effects of Respiratory Motion on Passively Scattered Proton Therapy Versus Intensity Modulated Photon Therapy for Stage III Lung Cancer: Are Proton Plans More Sensitive to Breathing Motion?

Purpose: To quantify and compare the effects of respiratory motion on paired passively scattered proton therapy (PSPT) and intensity modulated photon therapy (IMRT) plans; and to establish the relationship between the magnitude of tumor motion and the respiratory-induced dose difference for both modalities. Methods and Materials: In a randomized clinical trial comparing PSPT and IMRT, radiation therapy plans have been designed according to common planning protocols. Four-dimensional (4D) dose was computed for PSPT and IMRT plans for a patient cohort with respiratory motion ranging from 3 to 17 mm. Image registration and dose accumulation were performed using grayscale-based deformable image registration algorithms. The dose–volume histogram (DVH) differences (4D-3D [3D = 3-dimensional]) were compared for PSPT and IMRT. Changes in 4D-3D dose were correlated to the magnitude of tumor respiratory motion. Results: The average 4D-3D dose to 95% of the internal target volume was close to zero, with 19 of 20 patients within 1% of prescribed dose for both modalities. The mean 4D-3D between the 2 modalities was not statistically significant (P<.05) for all dose–volume histogram indices (mean ± SD) except the lung V5 (PSPT: +1.1% ± 0.9%; IMRT: +0.4% ± 1.2%) and maximum cord dose (PSPT: +1.5 ± 2.9 Gy; IMRT: 0.0 ± 0.2 Gy). Changes in 4D-3D dose were correlated to tumor motion for only 2 indices: dose to 95% planning target volume, and heterogeneity index. Conclusions: With our current margin formalisms, target coverage was maintained in the presence of respiratory motion up to 17 mm for both PSPT and IMRT. Only 2 of 11 4D-3D indices (lung V5 and spinal cord maximum) were statistically distinguishable between PSPT and IMRT, contrary to the notion that proton therapy will be more susceptible to respiratory motion. Because of the lack of strong correlations with 4D-3D dose differences in PSPT and IMRT, the extent of tumor motion was not an adequate predictor of potential dosimetric error caused by breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-BRF-06: 3D Pancreas MRI Segmentation Using Dictionary Learning and Manifold Clustering

Purpose: The recent advent of MRI guided radiotherapy machines has lent an exciting platform for soft tissue target localization during treatment. However, tools to efficiently utilize MRI images for such purpose have not been developed. Specifically, to efficiently quantify the organ motion, we develop an automated segmentation method using dictionary learning and manifold clustering (DLMC). Methods: Fast 3D HASTE and VIBE MR images of 2 healthy volunteers and 3 patients were acquired. A bounding box was defined to include pancreas and surrounding normal organs including the liver, duodenum and stomach. The first slice of the MRI was used for dictionary learning based on mean-shift clustering and K-SVD sparse representation. Subsequent images were iteratively reconstructed until the error is less than a preset threshold. The preliminarily segmentation was subject to the constraints of manifold clustering. The segmentation results were compared with the mean shift merging (MSM), level set (LS) and manual segmentation methods. Results: DLMC resulted in consistently higher accuracy and robustness than comparing methods. Using manual contours as the ground truth, the mean Dices indices for all subjects are 0.54, 0.56 and 0.67 for MSM, LS and DLMC, respectively based on the HASTE image. The mean Dices indices are 0.70, 0.77 and 0.79 for the three methods based on VIBE images. DLMC is clearly more robust on the patients with the diseased pancreas while LS and MSM tend to over-segment the pancreas. DLMC also achieved higher sensitivity (0.80) and specificity (0.99) combining both imaging techniques. LS achieved equivalent sensitivity on VIBE images but was more computationally inefficient. Conclusion: We showed that pancreas and surrounding normal organs can be reliably segmented based on fast MRI using DLMC. This method will facilitate both planning volume definition and imaging guidance during treatment.

60 APPLIED LIFE SCIENCES↗

Machine Learning for Solar Technology Portfolio Management

Technology readiness level (TRL) labeling and forecasting today is done entirely manually. A computationally-assisted model of a TRL-like classification for estimation and tracking could enable a research and development (R&D) portfolio manager to more accurately estimate the relative level of development for technologies in that portfolio. This report describes the work to understand readiness level systems, train a machine learning algorithm to recognize textual indicators of particular readiness levels within written material from carefully chosen case studies in renewable technology development, and apply that algorithm to predict the readiness levels of other technology development cases. We account for the results of each step of the work conducted, including the predictive accuracy of the trained model: 54% correct, within a +/-1 readiness level error threshold and a root mean squared error of 1.88. Great potential remains to improve and apply this model for management of individual projects and across portfolios.

14 SOLAR ENERGY↗

Machine Learning for Solar Technology Portfolio Management

Technology readiness level (TRL) labeling and forecasting today is done entirely manually. A computationally-assisted model of a TRL-like classification for estimation and tracking could enable a research and development (R&D) portfolio manager to more accurately estimate the relative level of development for technologies in that portfolio. This report describes the work to understand readiness level systems, train a machine learning algorithm to recognize textual indicators of particular readiness levels within written material from carefully chosen case studies in renewable technology development, and apply that algorithm to predict the readiness levels of other technology development cases. We account for the results of each step of the work conducted, including the predictive accuracy of the trained model: 54% correct, within a +/-1 readiness level error threshold and a root mean squared error of 1.88. Great potential remains to improve and apply this model for management of individual projects and across portfolios.

14 SOLAR ENERGY↗

Modeling the Swift BAT trigger algorithm with machine learning

To draw inferences about gamma-ray burst (GRB) source populations based on Swift observations, it is essential to understand the detection efficiency of the Swift burst alert telescope (BAT). This study considers the problem of modeling the Swift/BAT triggering algorithm for long GRBs, a computationally expensive procedure, and models it using machine learning algorithms. A large sample of simulated GRBs from Lien et al. is used to train various models: random forests, boosted decision trees (with AdaBoost), support vector machines, and artificial neural networks. The best models have accuracies of ≳97% (≲3% error), which is a significant improvement on a cut in GRB flux, which has an accuracy of 89.6% (10.4% error). These models are then used to measure the detection efficiency of Swift as a function of redshift z, which is used to perform Bayesian parameter estimation on the GRB rate distribution. We find a local GRB rate density of n{sub 0}∼0.48{sub −0.23}{sup +0.41} Gpc{sup −3} yr{sup −1} with power-law indices of n{sub 1}∼1.7{sub −0.5}{sup +0.6} and n{sub 2}∼−5.9{sub −0.1}{sup +5.7} for GRBs above and below a break point of z{sub 1}∼6.8{sub −3.2}{sup +2.8}. This methodology is able to improve upon earlier studies by more accurately modeling Swift detection and using this for fully Bayesian model fitting.

79 ASTRONOMY AND ASTROPHYSICS↗

Emission or atmospheric processes? An attempt to attribute the source of large bias of aerosols in eastern China simulated by global climate models

Here, global climate models often underestimate aerosol loadings in China, and these biases can have significant implications for anthropogenic aerosol radiative forcing and climate effects. The biases may be caused by either the emission inventory or the treatment of aerosol processes in the models, or both, but so far no consensus has been reached. In this study, a relatively new emission inventory based on energy statistics and technology, Multi-resolution Emission Inventory for China (MEIC), is used to drive the Community Atmosphere Model version 5 (CAM5) to evaluate aerosol distribution and radiative effects against observations in China. The model results are compared with the model simulations with the widely used Intergovernmental Panel on Climate Change Fifth Assessment Report (IPCC AR5) emission inventory. We find that the new MEIC emission improves the aerosol optical depth (AOD) simulations in eastern China and explains 22–28 % of the AOD low bias simulated with the AR5 emission. However, AOD is still biased low in eastern China. Seasonal variation of the MEIC emission leads to a better agreement with the observed seasonal variation of primary aerosols than the AR5 emission, but the concentrations are still underestimated. This implies that the atmospheric loadings of primary aerosols are closely related to the emission, which may still be underestimated over eastern China. In contrast, the seasonal variations of secondary aerosols depend more on aerosol processes (e.g., gas- and aqueous-phase production from precursor gases) that are associated with meteorological conditions and to a lesser extent on the emission. It indicates that the emissions of precursor gases for the secondary aerosols alone cannot explain the low bias in the model. Aerosol secondary production processes in CAM5 should also be revisited. The simulation using MEIC estimates the annual-average aerosol direct radiative effects (ADREs) at the top of the atmosphere (TOA), at the surface, and in the atmosphere to be –5.02, –18.47, and 13.45 W m –2 , respectively, over eastern China, which are enhanced by –0.91, –3.48, and 2.57 W m –2 compared with the AR5 emission. The differences of ADREs by using MEIC and AR5 emissions are larger than the decadal changes of the modeled ADREs, indicating the uncertainty of the emission inventories. This study highlights the importance of improving both the emission and aerosol secondary production processes in modeling the atmospheric aerosols and their radiative effects. Yet, if the estimations of MEIC emissions in trace gases do not suffer similar biases to those in the AOD, our findings will help affirm a fundamental error in the conversion from precursor gases to secondary aerosols as hinted in other recent studies following different approaches.

54 ENVIRONMENTAL SCIENCES↗