Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Analysis of Solar Spectral Irradiance Measurements from the SBUV/2-Series and the SSBUV Instruments

During this period of performance, 1 March 1997 - 31 August 1997, the NOAA-11 SBUV/2 solar spectral irradiance data set was validated using both internal and external assessments. Initial quality checking revealed minor problems with the data (e.g. residual goniometric errors, that were manifest as differences between the two scans acquired each day). The sources of these errors were determined and the errors were corrected. Time series were constructed for selected wavelengths and the solar irradiance changes measured by the instrument were compared to a Mg II proxy-based model of short- and long-term solar irradiance variations. This analysis suggested that errors due to residual, uncorrected long-term instrument drift have been reduced to less than 1-2% over the entire 5.5 year NOAA-11 data record. Detailed statistical analysis was performed. This analysis, which will be documented in a manuscript now in preparation, conclusively demonstrates the evolution of solar rotation periodicity and strength during solar cycle 22.

Cebula, Richard P.↗

Error determination of a successive correction type objective analysis scheme

The Purdue Regional Objective Analysis of the Mesoscale (PROAM) is a successive correction type scheme for the analysis of surface meteorological data. The scheme is subjected to a series of experiments to evaluate its performance under a variety of analysis conditions. The tests include use of a known analytic temperature distribution to quantify error bounds for the scheme. Similar experiments were conducted using actual atmospheric data. Results indicate that the multiple pass technique increases the accuracy of the analysis. Furthermore, the tests suggest appropriate values for the analysis parameters in resolving disturbances for the data set used in this investigation.

Smith, D. R.↗

SU-E-T-50: A Multi-Institutional Study of Independent Dose Verification Software Program for Lung SBRT

Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity-region. The tolerance level (TL) of the secondary check using the independent dose verification may be variable in lung SBRT plans. We conducted a multi-institutional study to evaluate the tolerance level of lung SBRT plans shown in the AAPM TG114. Methods: Five institutes in Japan participated in this study. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. Analytical Anisotropic Algorithm (AAA), Pencil Beam Convolution with modified Batho-method (PBC-B) and Adaptive Convolve (AC) were used for lung SBRT planning. A measurement using an ion-chamber was performed in a heterogeneous phantom to compare doses from the three different algorithms and the SMU to the measured dose. In addition to it, a retrospective analysis using clinical lung SBRT plans (547 beams from 77 patients) was conducted to evaluate the confidence limit (CL, Average±2SD) in dose between the three algorithms and the SMU. Results: Compared to the measurement, the AAA showed the larger systematic dose error of 2.9±3.2% than PBC-B and AC. The Clarkson-based SMU showed larger error of 5.8±3.8%. The CLs for clinical plans were 7.7±6.0 % (AAA), 5.3±3.3 % (AC), 5.7±3.4 % (PBC -B), respectively. Conclusion: The TLs from the CLs were evaluated. A Clarkson-based system shows a large systematic variation because of inhomogeneous correction. The AAA showed a significant variation. Thus, we must consider the difference of inhomogeneous correction as well as the dependence of dose calculation engine.

60 APPLIED LIFE SCIENCES↗

2025 Review and Revision of Federal Guidance Report 15

Federal Guidance Report No. 15 (FGR 15), External Exposure to Radionuclides in Air, Water and Soil, published in 2019 and referred to below as FGR 2019, provides age-specific effective dose rate coefficients for reference persons externally exposed to each of 1252 radionuclides homogenously distributed in environmental media. Soon after completion of FGR 2019, the International Commission on Radiological Protection (ICRP) published a similar report (ICRP Publication 144, 2020) addressing the same radionuclides and many of the external exposure scenarios addressed in FGR 2019. In 2023 Argonne National Laboratory (ANL) published a review of dose coefficients in FGR 2019, concluding that “The external effective dose from beta radiation is not appropriately accounted for in FGR 15 for both low- and high-energy beta emitters in air, in soil, and on soil surfaces.” That conclusion was based largely on comparisons of dose coefficients in FGR 2019 with values in ICRP Publication 144 but also on consideration of some unexpected patterns of equivalent dose rate coefficients across tissues and of effective dose rate coefficients across different soil depths, for a selected set of low-energy beta emitters. In response to the ANL report, the Center for Radiation Protection Knowledge (CRPK) at Oak Ridge National Laboratory (ORNL) performed an extensive reexamination of the methods and published values of FGR 2019. CRPK found that coding errors had resulted in inaccurate estimates, primarily overestimates, in many of the dose coefficients tabulated in FGR 2019 but that many of the differences between results in FGR 2019 and ICRP Publication 144 could be traced to differences in methodology. CRPK has corrected all errors in FGR 2019 associated with the coding errors and has taken the opportunity to improve a major portion of the remaining dose coefficients in FGR 2019, primarily through additional Monte Carlo calculations resulting in improved statistics for tissue equivalent dose rate coefficients for exposure to monoenergetic sources. This has eliminated the need for extrapolation of results from high and medium energies to low energies, as was done in FGR 2019. In addition, inconsistencies in the methodology identified in the review, such as computational representation of the adult female, were eliminated. The revised effective dose rate coefficients are consistent with values in ICRP Publication 144 except for differences in values clearly arising from differences in methodology; and differences in values for a relatively small set of very low-energy radionuclides with highly uncertain dose coefficients regardless of methodology.

54 ENVIRONMENTAL SCIENCES↗

An Automatic Terminal Guidance System for Rendezvous with a Satellite

This study includes a consideration of the design philosophy for an automatic terminal guidance system, a derivation of guidance equations required, and an outline of the general type of instrumentation necessary to provide the essential information. A control system for a sample vehicle is analyzed. A representative case, rendezvous with a satellite in circular orbit at 400 nautical miles, was examined. Terminal-stage nominal burning times of 200 and 400 seconds were used. For the 200-second case, initial errors in circumferential displacement of +/- 25,000 feet, in radial displacement of 7,000 to -9,000 feet, and in lateral displacement of +/- 20,000 feet were within the capabilities of the system. Velocity errors of 300 to -400 ft/sec in the circumferential direction, 180 to -200 ft/sec in the radial direction, and velocity offsets of at least 20 (+/- 800 ft/sec) in the lateral direction could also be handled. The 400-second case was capable of correcting larger errors, but limits were not determined. The dependence of required characteristic velocity on initial errors was determined and it was found that increases over the nominal terminal-stage characteristic velocity of the order of 15 percent covered most of the previously mentioned in-plane errors. The requirements were more severe for cases with lateral velocity offsets. A simplified set of guidance equations was tested and produced only slight variations in performance. Overall velocity requirements and mass ratios were determined for terminal-stage burning times of 100, 200, 300, and 400 seconds and for a range of transfer angles by using exact calculations for the terminal stage and an impulsive launching velocity. These results indicated that the shortest burning time consistent with the launch guidance errors expected gave the best mass ratio.

Carney, Terrance M.↗

Resolution of the COBE Earth sensor anomaly

Since its launch on November 18, 1989, the Earth sensors on the Cosmic Background Explorer (COBE) have shown much greater noise than expected. The problem was traced to an error in Earth horizon acquisition-of-signal (AOS) times. Due to this error, the AOS timing correction was ignored, causing Earth sensor split-to-index (SI) angles to be incorrectly time-tagged to minor frame synchronization times. Resulting Earth sensor residuals, based on gyro-propagated fine attitude solutions, were as large as plus or minus 0.45 deg (much greater than plus or minus 0.10 deg from scanner specifications (Reference 1)). Also, discontinuities in single-frame coarse attitude pitch and roll angles (as large as 0.80 and 0.30 deg, respectively) were noted several times during each orbit. However, over the course of the mission, each Earth sensor was observed to independently and unexpectedly reset and then reactivate into a new configuration. Although the telemetered AOS timing corrections are still in error, a procedure has been developed to approximate and apply these corrections. This paper describes the approach, analysis, and results of approximating and applying AOS timing adjustments to correct Earth scanner data. Furthermore, due to the continuing degradation of COBE's gyroscopes, gyro-propagated fine attitude solutions may soon become unavailable, requiring an alternative method for attitude determination. By correcting Earth scanner AOS telemetry, as described in this paper, more accurate single-frame attitude solutions are obtained. All aforementioned pitch and roll discontinuities are removed. When proper AOS corrections are applied, the standard deviation of pitch residuals between coarse attitude and gyro-propagated fine attitude solutions decrease by a factor of 3. Also, the overall standard deviation of SI residuals from fine attitude solutions decrease by a factor of 4 (meeting sensor specifications) when AOS corrections are applied.

Sedler, J.↗

Clinical Evaluation of a Robotic 6-Degree of Freedom Treatment Couch for Frameless Radiosurgery

Purpose: To evaluate the added value of 6-degree of freedom (DOF) patient positioning with a robotic couch compared with 4DOF positioning for intracranial lesions and to estimate the immobilization characteristics of the BrainLAB frameless mask (BrainLAB AG, Feldkirchen, Germany), more specifically, the setup errors and intrafraction motion. Methods and Materials: We enrolled 40 patients with 66 brain metastases treated with frameless stereotactic radiosurgery and a 6DOF robotic couch. Patient positioning was performed with the BrainLAB ExacTrac stereoscopic X-ray system. Positioning results were collected before and after treatment to assess patient setup error and intrafraction motion. Existing treatment planning data were loaded and simulated for 4DOF positioning and compared with the 6DOF positioning. The clinical relevance was analyzed by means of the Paddick conformity index and the ratio of prescribed isodose volume covered with 4DOF to that obtained with the 6DOF positioning. Results: The mean three-dimensional setup error before 6DOF correction was 1.91 mm (SD, 1.25 mm). The rotational errors were larger in the longitudinal (mean, 0.23 Degree-Sign ; SD, 0.82 Degree-Sign ) direction compared with the lateral (mean, -0.09 Degree-Sign ; SD, 0.72 Degree-Sign ) and vertical (mean, -0.10 Degree-Sign ; SD, 1.03 Degree-Sign ) directions (p < 0.05). The mean three-dimensional intrafraction shift was 0.58 mm (SD, 0.42 mm). The mean intrafractional rotational errors were comparable for the vertical, longitudinal, and lateral directions: 0.01 Degree-Sign (SD, 0.35 Degree-Sign ), 0.03 Degree-Sign (SD, 0.31 Degree-Sign ), and -0.03 Degree-Sign (SD, 0.33 Degree-Sign ), respectively. The mean conformity index decreased from 0.68 (SD, 0.08) (6DOF) to 0.59 (SD, 0.12) (4DOF) (p < 0.05). A loss of prescribed isodose coverage of 5% (SD, 0.08) was found with the 4DOF positioning (p < 0.05). Half a degree for longitudinal and lateral rotations can be identified as a threshold for coverage loss. Conclusions: With a mask immobilization, patient setup error and intrafraction motions need to be evaluated and corrected for. The 6DOF patient positioning with a 6DOF robotic couch to correct translational and rotational setup errors improves target positioning with respect to treatment isocenter, which is in direct relation with the clinical outcome, compared with the 4DOF positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flight test evaluation of predicted light aircraft drag, performance, and stability

A technique was developed which permits simultaneous extraction of complete lift, drag, and thrust power curves from time histories of a single aircraft maneuver such as a pull up (from V max to V stall) and pushover (to V max for level flight). The technique, which is an extension of nonlinear equations of motion of the parameter identification methods of Iliff and Taylor and includes provisions for internal data compatibility improvement as well, was shown to be capable of correcting random errors in the most sensitive data channel and yielding highly accurate results. Flow charts, listings, sample inputs and outputs for the relevant routines are provided as appendices. This technique was applied to flight data taken on the ATLIT aircraft. Lack of adequate knowledge of the correct full throttle thrust horsepower true airspeed variation and considerable internal data inconsistency made it impossible to apply the trajectory matching features of the technique.

Smetana, F. O.↗

Heikkila's mechanism for impulsive plasma transport through the magnetopause - A reexamination

This paper reexamines arguments formulated and restated by Heikkila to the effect that a magnetosheath plasma cloud having 'excess' momentum which impinges on the dayside magnetopause boundary is able to flow continuously through the boundary onto both open and closed flux tubes in the interior. It is shown that the argument used to arrive at this conclusion is not correct. The error in the argument concerns the nature of the flow which is associated with the induction electric field produced by the perturbed current layer, which was assumed by Heikkila to be such as to keep the plasma jet just moving with the boundary. Heikkila's argument, correctly applied, does not lead to 'impulsive transport' of plasma through the magnetopause.

Owen, C. J.↗

TOPEX/POSEIDON microwave radiometer performance and in-flight calibration

Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correction for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximately = 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximately = 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. AS 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 FGHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm root mean square (RMS) with consistent peformance under clear, cloudy, and windy conditions.

Ruf, C. S.↗

Optical Modeling Activities for NASA's James Webb Space Telescope (JWST): Wavefront Aberrations due to Alignment and Figure Compensation - 3

This is part three of a series describing the ongoing optical modeling activities for James Webb Space Telescope (JWST). The first two discussed modeling JWST on-orbit performance using wavefront sensitivities to predict line of sight motion induced blur, and stability during thermal transients. The work here investigates the aberrations resulting from alignment and figure compensation of the controllable degrees of freedom (primary and secondary mirrors), which may be encountered during ground alignment and on-orbit commissioning of the observatory. The optical design of the telescope is a three-mirror anastigmat, with an active fold mirror at the exit pupil for fine guiding. The primary mirror is over 6.5 meters in diameter, and is composed of 18 hexagonal segments that can individually positioned on hexapods, as well as compensated for radius of curvature. This effectively gives both alignment and figure control of the primary mirror. The secondary mirror can be moved in rigid body only, giving alignment control of the telescope. The tertiary mirror is fixed, however, as well as the location of the science instrumentation. Simulations are performed of various combinations of active alignment corrections of component figure errors, and of primary mirror figure corrections of alignment errors. Single field point and moderate field knowledge is assumed in the corrections. Aberrations over the field are reported for the varying cases, and examples presented.

Howard, Joseph↗

An Examination of the Spatial Distribution of Carbon Dioxide and Systematic Errors

The industrial period and modern age is characterized by combustion of coal, oil, and natural gas for primary energy and transportation leading to rising levels of atmospheric of CO2. This increase, which is being carefully measured, has ramifications throughout the biological world. Through remote sensing, it is possible to measure how many molecules of CO2 lie in a defined column of air. However, other gases and particles are present in the atmosphere, such as aerosols and water, which make such measurements more complicated1. Understanding the detailed geometry and path length of the observation is vital to computing the concentration of CO2. Comparing these satellite readings with ground-truth data (TCCON) the systematic errors arising from these sources can be assessed. Once the error is understood, it can be scaled for in the retrieval algorithms to create a set of data, which is closer to the TCCON measurements1. Using this process, the algorithms are being developed to reduce bias, within.1% worldwide of the true value. At this stage, the accuracy is within 1%, but through correcting small errors contained in the algorithms, such as accounting for the scattering of sunlight, the desired accuracy can be achieved.

Carbon Dioxide (CO2)↗

Investigation of Fiber Optics Based Phased Locked Diode Lasers

Optical power beaming requires a high intensity source and a system to address beam phase and location. A synthetic aperture array of phased locked sources can provide the necessary power levels as well as a means to correct for phase errors. A fiber optic phase modulator with a master oscillator and power amplifier (MOPA) using an injection-locking semiconductor optical amplifier has proven to be effective in correcting phase errors as large as 4pi in an interferometer system. Phase corrections with the piezoelectric fiber stretcher were made from 0 - 10 kHz, with most application oriented corrections requiring only 1 kHz. The amplifier did not lose locked power output while the phase was changed, however its performance was below expectation. Results of this investigation indicate fiber stretchers and amplifiers can be incorporated into a MOPA system to achieve successful earth based power beaming.

Burke, Paul D.↗

Measurement of cardiac output from dynamic pulmonary circulation time CT

Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA, which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Density-Corrected DFT to Understand Density-Driven and Functional-Dependent Errors in Ab Initio Simulations of the Hydrated Electron

The hydrated electron, an excess electron in liquid water, plays a crucial role in a plethora of chemical processes, motivating extensive research efforts to characterize its structure, dynamics, and reactivity in solution. Recent theoretical approaches to understanding this intriguing object have involved ab initio simulations based on density functional theory (DFT). Although DFT allows for the study of hydrated electron reactivity and quantum mechanical behavior, it is well-known that anionic systems can suffer from significant density-driven errors (DDEs). Density-corrected DFT (DC-DFT) provides a framework to mitigate such errors; the method reduces DDEs by replacing the self-consistent (SC) density associated with a given density functional with the Hartree–Fock (HF) density. Since HF densities tend to be more localized than DFT SC densities, the DC-DFT scheme significantly improves errors in calculations where the SC density is spuriously delocalized. Here, we investigate how the use of density correction affects the calculated properties of the DFT-simulated (PBEh) hydrated electron, a particularly challenging diffuse anionic system to simulate. First, we analyze charge delocalization in a system consisting of a model octahedral hydrated electron water cluster (the so-called Kevan structure) along with a spatially separated sulfur atom. We show that the use of density correction indeed reduces DDEs in comparison to a standard DFT global hybrid functional. We then propagate molecular dynamics trajectories of the hydrated electron using DC-DFT, where we find that DC further localizes electron density in the cavity region, a signature of reduced charge delocalization. Unfortunately, the decreased radius of gyration of the spin density and corresponding tightening of the local solvation structure from density correction causes predicted observables to deviate further from experimental measurements than when density correction is not employed. Here, we argue that DC’s worse agreement with experiment results from the removal of a fortuitous cancellation of errors that is intrinsic to the PBEh functional. This indicates that the difficulties with DFT to simulate hydrated electrons are primarily due to the inherent approximations in DFT rather than to density-driven errors.

Density functional theory↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

A two dimensional interface element for coupling of independently modeled three dimensional finite element meshes and extensions to dynamic and non-linear regimes

The work reported here pertains only to the first year of research for a three year proposal period. As a prelude to this two dimensional interface element, the one dimensional element was tested and errors were discovered in the code for built-up structures and curved interfaces. These errors were corrected and the benchmark Boeing composite crown panel was analyzed successfully. A study of various splines led to the conclusion that cubic B-splines best suit this interface element application. A least squares approach combined with cubic B-splines was constructed to make a smooth function from the noisy data obtained with random error in the coordinate data points of the Boeing crown panel analysis. Preliminary investigations for the formulation of discontinuous 2-D shell and 3-D solid elements were conducted.

Aminpour, Mohammad↗

Investigation of several aspects of LANDSAT-4 data quality

No insurmountable problems in change detection analysis were found when portions of scenes collected simultaneously by LANDSAT 4 MSS and either LANDSAT 2 or 3. The cause of the periodic noise in LANDSAT 4 MSS images which had a RMS value of approximately 2DN should be corrected in the LANDSAT D instrument before its launch. Analysis of the P-tape of the Arkansas scene shows bands within the same focal plane very well registered except for the thermal band which was misregistered by approximately three 28.5 meter pixels in both directions. It is possible to derive tight confidence bounds for the registration errors. Preliminary analyses of the Sacramento and Arkansas scenes reveals a very high degree of consistency with earlier results for bands 3 vs 1, 3 vs 4, and 3 vs 5. Results are presented in table form. It is suggested that attention be given to the standard deviations of registrations errors to judge whether or not they will be within specification once any known mean registration errors are corrected. Techniques used for MTF analysis of a Washington scene produced noisy results.

Wrigley, R. C.↗