Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Comparison of Two IRI Plasmasphere Extensions with GPS-TEC Observations

Two plasmasphere extensions of the International Reference Ionosphere are made available for the users. It is aimed to estimate the effect of charged particles on technical devices in the Earth's environment and to define the ionosphere-plasmasphere operational conditions compatible with existing and future systems of radio communication, radio navigation and other relevant radio technologies in the ranges of medium and higher frequencies. The Global Core Plasma Model (GCPM-2000) of Gallagher et al. (2000) is an empirical description of thermal plasma densities in the plasmasphere, plasmapause, magnetospheric trough, and polar cap. GCPM-2000 uses the Kp index and is coupled to IRI in the transition region 500-600 km. The IZMIRAN plasmasphere model (Chasovitin et al., 1998; Gulyaeva et al., 2002) is an empirical model based on whistler and satellite observations. It presents global vertical analytical profiles of electron density smoothly fitted to IRI electron density profile at 1000 km altitude and extended towards the plasmapause (up to 36,000 km). For the smooth fitting of the two models, the shape of the IRI topside electron density profile is improved using ISIS 1, ISIS 2, and IK19 satellite inputs (Gulyaeva, 2003). The plasmasphere model depends on solar activity and magnetic activity (kp-index). The two IRI plasmasphere extensions are compared in the present study with the total electron content derived from records of Global Positioning Satellites (GPS-TEC) observations for different latitudinal, solar activity, magnetic activity, diurnal and seasonal conditions. The differences of model TEC with observed TEC in the topside ionosphere and plasmasphere are discussed.

Gulyacva, Tamara↗

Multiwavelength Variability of Sagittarius A* in 2019 July

We report a timing analysis of near-infrared (NIR), X-ray, and submillimeter data during a 3 day coordinated campaign observing Sagittarius A* . Data were collected at 4.5 μm with the Spitzer Space Telescope, 2–8 keV with the Chandra X-ray Observatory, 3–70 keV with NuSTAR, 340 GHz with ALMA, and 2.2 μm with the GRAVITY instrument on the Very Large Telescope Interferometer. Two dates show moderate variability with no significant lags between the submillimeter and the infrared at 99% confidence. A moderately bright NIR flare (FK ∼ 15 mJy) was captured on July 18 simultaneous with an X-ray flare (F2−10 keV ∼ 0.1 counts s−1 ) that most likely preceded bright submillimeter flux (F340 GHz ∼ 5.5 Jy) by about + - + 34 33 14 minutes at 99% confidence. The uncertainty in this lag is dominated by the fact that we did not observe the peak of the submillimeter emission. A synchrotron source cooled through adiabatic expansion can describe a rise in the submillimeter once the synchrotron self-Compton NIR and X-ray peaks have faded. This model predicts high GHz and THz fluxes at the time of the NIR/X-ray peak and electron densities well above those implied from average accretion rates for Sgr A* . However, the higher electron density postulated in this scenario would be in agreement with the idea that 2019 was an extraordinary epoch with a heightened accretion rate. Since the NIR and X-ray peaks can also be fit by a nonthermal synchrotron source with lower electron densities, we cannot rule out an unrelated chance coincidence of this bright submillimeter flare with the NIR/X-ray emission.

Galactic center↗

Dopant Content and Thermal Treatment of Cd1-xZnxTe : Effects on Point-Defect Structures

We measured, in the 873-1173 K temperature range, the temperature- and Cd vapor-pressure-dependences of the free electron density in single CdTe(In) crystals with different In contents. Increasing the cooling rate of the crystals and/or decreasing the well-defined Cd vapor pressure reduced the free-electron density. We interpreted and modelled these phenomena and the crystal's high-temperature electrical properties within the framework of Kroger's point-defect theory. Our experiments demonstrated the possibility of controlling the free-electron density in CdTe(In) crystals by changing the cooling rate. We supplemented a point-defect structural study of CZT(In) crystals by low-temperature (80-420 K) electrical measurements. These findings allowed us to identify the nature of the point defects responsible for free-carrier scattering, which is an important parameter influencing the mutau-product value in detector-grade material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of nonlinear ohmic heating and ponderomotive force effects on the self-focusing and defocusing of Gaussian laser beams in collisional underdense plasmas

In the present paper, the propagation characteristics of a linearly polarized gaussian laser beam in a non-isothermal underdense collisional plasma is studied. By considering the effects of the ponderomotive force and ohmic heating of plasma electrons as the nonlinear mechanisms, the second order differential equation of the dimensionless beam width parameter has been obtained and solved at several initial ion temperatures. Furthermore, by using the nonlinear dielectric permittivity of the mentioned plasma medium in the paraxial approximation and its dependence on the propagation characteristics of the gaussian laser pulse, the perturbed electron density n{sub e}/n{sub 0e} is obtained and its variation in terms of the dimensionless plasma length is analyzed at different initial ion temperatures. Our results show that the dimensionless beam width parameter is strongly influenced by the initial plasma ion temperature. It is found that, for the self-focusing regime, the plasma electron density perturbation continuously oscillates between the initial density distribution and a minimum, and for the defocusing regime, the plasma electron density perturbation continuously oscillates between the initial density distribution and a maximum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synthetic Diagnostics Platform for Fusion Plasma and a Two-Dimensional Synthetic Electron Cyclotron Emission Imaging Code

Magnetic confinement fusion is one of the most promising approaches to achieve fusion energy. With the rapid increase of the computational power over the past decades, numerical simulation have become an important tool to study the fusion plasmas. Eventually, the numerical models will be used to predict the performance of future devices, such as the International Thermonuclear Experiment Reactor (ITER) or DEMO. However, the reliability of these models needs to be carefully validated against experiments before the results can be trusted. The validation between simulations and measurements is hard particularly because the quantities directly available from both sides are different. While the simulations have the information of the plasma quantities calculated explicitly, the measurements are usually in forms of diagnostic signals. The traditional way of making the comparison relies on the diagnosticians to interpret the measured signals as plasma quantities. The interpretation is in general very complicated and sometimes not even unique. In contrast, given the plasma quantities from the plasma simulations, we can unambiguously calculate the generation and propagation of the diagnostic signals. These calculations are called synthetic diagnostics, and they enable an alternate way to compare the simulation results with the measurements. In this dissertation, we present a platform for developing and applying synthetic diagnostic codes. Three diagnostics on the platform are introduced. The reflectometry and beam emission spectroscopy diagnostics measure the electron density, and the electron cyclotron emission diagnostic measures the electron temperature. The theoretical derivation and numerical implementation of a new two dimensional Electron cyclotron Emission Imaging code is discussed in detail. This new code has shown the potential to address many challenging aspects of the present ECE measurements, such as runaway electron effects, and detection of the cross phase between the electron temperature and density fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport Measurements of Surface Electrons in 200-nm-Deep Helium-Filled Microchannels Above Amorphous Metallic Electrodes

We report transport measurements of electrons on helium in a microchannel device where the channels are 200 nm deep and 3μm wide. The channels are fabricated above amorphous metallic Ta 40 W 40 Si 20 , which has surface roughness below 1 nm and minimal variations in work function across the surface due to the absence of polycrystalline grains. We are able to set the electron density in the channels using a ground plane. We estimate a mobility of 300cm 2 /Vs and electron densities as high as 2.56×10 9 cm -2 . We demonstrate control of the transport using a barrier which enables pinch-off at a central microchannel connecting two reservoirs. The conductance through the central microchannel is measured to be 10 nS for an electron density of 1.58×10 9 cm -2 . Lastly, our work extends transport measurements of surface electrons to thin helium films in microchannel devices above metallic substrates.

74 ATOMIC AND MOLECULAR PHYSICS↗

HERSCHEL GALACTIC PLANE SURVEY OF [N ii] FINE STRUCTURE EMISSION

We present the first large-scale high angular resolution survey of ionized nitrogen in the Galactic Plane through emission of its two fine structure transitions ([N ii]) at 122 and 205 μm. The observations were largely obtained with the PACS instrument onboard the Herschel Space Observatory. The lines of sight were in the Galactic plane, following those of the Herschel OTKP project GOT C+. Both lines are reliably detected at the 10{sup −8}–10{sup −7} Wm{sup −2} sr{sup −1} level over the range –60° ≤ l ≤ 60°. The rms of the intensity among the 25 PACS spaxels of a given pointing is typically less than one third of the mean intensity, showing that the emission is extended. [N ii] is produced in gas in which hydrogen is ionized, and collisional excitation is by electrons. The ratio of the two fine structure transitions provides a direct measurement of the electron density, yielding n(e) largely in the range 10–50 cm{sup −3} with an average value of 29 cm{sup −3} and N{sup +} column densities 10{sup 16}–10{sup 17} cm{sup −2}. [N ii] emission is highly correlated with that of [C ii], and we calculate that between 1/3 and 1/2 of the [C ii] emission is associated with the ionized gas. The relatively high electron densities indicate that the source of the [N ii] emission is not the warm ionized medium (WIM), which has electron densities more than 100 times smaller. Possible origins of the observed [N ii] include the ionized surfaces of dense atomic and molecular clouds, the extended low-density envelopes of H ii regions, and low-filling factor high-density fluctuations of the WIM.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-608: Perturbation Corrections for Alanine Dosimeters in Different Phantom Materials in High-Energy Photon Beams

Purpose: Alanine dosimeters are often used for in-vivo dosimetry purposes in radiation therapy. In a Monte Carlo study the influence of 20 different surrounding/phantom materials for alanine dosimeters was investigated. The investigations were performed in high-energy photon beams, covering the whole range from {sup 60}Co up to 25 MV-X. The aim of the study is the introduction of a perturbation correction k{sub env} for alanine dosimeters accounting for the environmental material. Methods: The influence of different surrounding materials on the response of alanine dosimeters was investigated with Monte Carlo simulations using the EGSnrc code. The photon source was adapted with BEAMnrc to a {sup 60}Co unit and an Elekta (E{sub nom}=6, 10, 25 MV-X) linear accelerator. Different tissue-equivalent materials ranging from cortical bone to lung were investigated. In addition to available phantom materials, some material compositions were taken and scaled to different electron densities. The depth of the alanine detectors within the different phantom materials corresponds to 5 cm depth in water, i.e. the depth is scaled according to the electron density (n{sub e}/n{sub e,w}) of the corresponding phantom material. The dose was scored within the detector volume once for an alanine/paraffin mixture and once for a liquid water voxel. The relative response, the ratio of the absorbed dose to alanine to the absorbed dose to water, was calculated and compared to the corresponding ratio under reference conditions. Results: For each beam quality the relative response r and the correction factor for the environment kenv was calculated. k{sub env}=0.9991+0.0049 *((n{sub e}/n{sub e,w})−0.7659){sup 3} Conclusion: A perturbation correction factor k{sub env} accounting for the phantom environment has been introduced. The response of the alanine dosimeter can be considered independent of the surrounding material for relative electron densities (n{sub e}/n{sub e,w}) between 1 and 1.4. For denser materials such as bone or much less dense surroundings such as lung, a small correction would be appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of type III solar radio burst theories using satellite radio observations and particle measurements.

The required electron density to excite a type III solar burst can be predicted from different theories, using the low frequency radio observations of the RAE-1 satellite. Electron flux measurements by satellite in the vicinity of 1 AU then give an independent means of comparing these predicted exciter electron densities to the measured density. On this basis, one theory predicts the electron density in closest agreement with the measured values.

Evans, L. G.↗

High-Temperature SiC Power Module with Integrated SiC Gate Drivers for Future High-Density Power Electronics Applications

This paper presents the testing results of an all-silicon carbide (SiC) intelligent power module (IPM) for use in future high-density power electronics applications. The IPM has high-temperature capability and contains both SiC power devices and SiC gate driver integrated circuits (ICs). The high-temperature capability of the SiC gate driver ICs allows for them to be packaged into the power module and be located physically close to the power devices. This provides a distinct advantage by reducing the gate driver loop inductance, which promotes high frequency operation, while also reducing the overall volume of the system through higher levels of integration. The power module was tested in a bridgeless-boost converter to showcase the performance of the module in a system level application. The converter was initially operated with a switching frequency of 200 kHz with a peak output power of approximately 5 kW. The efficiency of the converter was then evaluated experimentally and optimized by increasing the overdrive voltage on the SiC gate driver ICs. Overall a peak efficiency of 97.7% was measured at 3.0 kW output. The converter s switching frequency was then increased to 500 kHz to prove the high frequency capability of the power module was then pushed to its limits and operated at a switching frequency of 500 kHz. With no further optimization of components, the converter was able to operate under these conditions and showed a peak efficiency of 95.0% at an output power of 2.1 kW.

Whitaker, Mr. Bret↗

Intermolecular Interactions and Electrostatic Properties of the [beta]-Hydroquinone Apohost: Implications for Supramolecular Chemistry

The crystal structure of the {beta}-polymorph of hydroquinone ({beta}-HQ), the apohost of a large family of clathrates, is reported with a specific focus on intermolecular interactions and the electrostatic nature of its cavity. Hirshfeld surface analysis reveals subtle close contacts between two interconnecting HQ networks, and the local packing and related close contacts were examined by breakdown of the fingerprint plot. An experimental multipole model containing anisotropic thermal parameters for hydrogen atoms has been successfully refined against 15(2) K single microcrystal synchrotron X-ray diffraction data. The experimental electron density model has been compared with a theoretical electron density calculated with the molecule embedded in its own crystal field. Hirshfeld charges, interaction energies and the electrostatic potential calculated for both models are qualitatively in good agreement, but small differences in the electrostatic potential persist due to charge transfer from all hydrogen atoms to the oxygen atoms in the theoretical model. The electrostatic potential in the center of the cavity is positive, very shallow and highly symmetric, suggesting that the inclusion of polar molecules in the void will involve a balance between opposing effects. The electric field is by symmetry zero in the center of the cavity, increasing to a value of 0.0185 e/{angstrom}{sup 2} (0.27 V/{angstrom}) 1 {angstrom} along the 3-fold axis and 0.0105 e/{angstrom}{sup 2} (0.15 V/{angstrom}) 1 {angstrom} along the perpendicular direction. While these values are substantial in a macroscopic context, they are quite small for a molecular cavity and are not expected to strongly polarize a guest molecule.

08 HYDROGEN↗

The characteristics of atmospheric radio frequency discharges with frequency increasing at a constant power density

A computational model is used to investigate the characteristics of atmospheric radio frequency discharges by increasing frequency from 20 to 100 MHz at a constant power density. The simulation results show that increasing frequency can effectively enhance electron density before the transition frequency but after it the ignition is quenched then the electron density decreases. However this simulation also indicates the maximum time-averaged electron energy reduces monotonically with the excitation frequency increasing at a constant power density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thioarsenides: A case for long-range Lewis acid-base-directed van der Waals interactions

Electron density distributions, bond paths, Laplacian and local energy density properties have been calculated for a number of As4Sn (n = 3,4,5) thioarsenide molecular crystals. On the basis of the distributions, the intramolecular As-S and As-As interactions classify as shared bonded interactions and the intermolecular As-S, As-As and S-S interactions classify as closed-shell van der Waals bonded interactions. The bulk of the intermolecular As-S bond paths link regions of locally concentrated electron density (Lewis base regions) with aligned regions of locally depleted electron density (Lewis acid regions) on adjacent molecules. The paths are comparable with intermolecular paths reported for several other molecular crystals that link aligned Lewis base and acid regions in a key-lock fashion, interactions that classified as long range Lewis acid-base directed van der Waals interactions. As the bulk of the intermolecular As-S bond paths (~70%) link Lewis acid-base regions on adjacent molecules, it appears that molecules adopt an arrangement that maximizes the number of As-S Lewis acid-base intermolecular bonded interactions. The maximization of the number of Lewis acid-base interactions appears to be connected with the close-packed array adopted by molecules: distorted cubic close-packed arrays are adopted for alacránite, pararealgar, uzonite, realgar and β-AsS and the distorted hexagonal close-packed arrays adopted by α- and β-dimorphite. A growth mechanism is proposed for thioarsenide molecular crystals from aqueous species that maximizes the number of long range Lewis acid-base vdW As-S bonded interactions with the resulting directed bond paths structuralizing the molecules as a molecular crystal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionospheric range-rate effects in satellite-to-satellite tracking

Ionospheric range and range rate corrections in satellite-to-satellite tracking were investigated and the magnitude of errors that have to be considered for communications between satellites and related experiments was defined. The major causes of the sudden and sometimes large variations apparent in the ionospheric range and range rate corrections along the satellite arc are the geometric effects of the raypath and the curved ionosphere, and the localized perturbations in electron density along the satellite-to-satellite line of sight. Ionospheric tracking errors are greatly effected by the following parameters, whose influence was thoroughly investigated: satellite height, height of maximum electron density, localized ionospheric perturbations and gradients, and electron density variations with diurnal, day-to-day, seasonal, and solar cycle patterns. The results point to the need of using a sophisticated modeling approach incorporating daily solar data, and where possible actual ionospheric measurements as update information. Simulations were performed for satellites at various heights: Apollo, Geos, and Nimbus tracked by ATS-6; and in two different geometric configurations: coplanar and perpendicular orbits.

Bent, R. B.↗

SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of separation.

60 APPLIED LIFE SCIENCES↗

Relativistic effects in the interaction of high intensity ultra-short laser pulse with collisional underdense plasma

In this paper, the effect of weakly relativistic ponderomotive force in the interaction of intense laser pulse with nonisothermal, underdense, collisional plasma is studied. Ponderomotive force modifies the electron density and temperature distribution. By considering the weakly relativistic effect and ohmic heating of plasma electrons, the nonlinear dielectric permittivity of plasma medium is obtained and the equation of electromagnetic wave propagation in plasma is solved. It is shown that with considering the ohmic heating of electrons and collisions, the effect of ponderomotive force in weakly relativistic regime leads to steepening the electron density profile and increases the temperature of plasma electrons noticeably. Bunches of electrons in plasma become narrower. By increasing the laser pulse strength, the wavelength of density oscillations decreases. In this regime of laser-plasma interaction, electron temperature increases sharply by increasing the intensity of laser pulse. The amplitude of electric and magnetic fields increases by increasing the laser pulse energy while their wavelength decreases and they lost their sinusoidal form.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the effects of an H2 gas release on the equatorial ionosphere

Three simulated point releases of H2 gas are carried out at 1930 LT over the magnetic equator: 5 kg at 300 km, 10 kg at 350 km, and 20 kg at 300 km. The subsequent effects on the ionosphere in the vicinity of these releases are studied by calculating the densities of O(+), OH(+), H2O(+), and H3O(+) from coupled time-dependent ion continuity equations. It is found that the 5-kg release produces a depleted electron density region, while a 10-kg release produces an electron density hole. Increasing the release to 20 kg yields substantial amounts of the product ions OH(+), H2O(+), and H3O(+). The dominant ions at the times of 52, 276, and 1252 sec after release are 55% for H3O(+), 47.6% for OH(+), and 72.7% for O(+), respectively. Moreover, 276 sec after release, percent depletions in the integrated electron density and Pederson conductivity are 5.8% and 2.9%, respectively, for the 5-kg release; 7.4% and 5.2%, respectively, for the 10-kg release; and 11.8% and 4.3%, respectively, for the 20-kg release. Whether or not such initial depletions are sufficient remains to be seen.

Anderson, D. N.↗

Embedding potentials for excited states of embedded species

Frozen-Density-Embedding Theory (FDET) is a formalism to obtain the upper bound of the ground-state energy of the total system and the corresponding embedded wavefunction by means of Euler-Lagrange equations [T. A. Wesolowski, Phys. Rev. A 77(1), 012504 (2008)]. FDET provides the expression for the embedding potential as a functional of the electron density of the embedded species, electron density of the environment, and the field generated by other charges in the environment. Under certain conditions, FDET leads to the exact ground-state energy and density of the whole system. Following Perdew-Levy theorem on stationary states of the ground-state energy functional, the other-than-ground-state stationary states of the FDET energy functional correspond to excited states. In the present work, we analyze such use of other-than-ground-state embedded wavefunctions obtained in practical calculations, i.e., when the FDET embedding potential is approximated. Three computational approaches based on FDET, that assure self-consistent excitation energy and embedded wavefunction dealing with the issue of orthogonality of embedded wavefunctions for different states in a different manner, are proposed and discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗