Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

Wave Energy Converter (WEC) Array Effects on Wave Current and Sediment Circulation: Monterey Bay CA.

The goal s of this study were to develop tools to quantitatively characterize environments where wave energy converter ( WEC ) devices may be installed and to assess e ffects on hydrodynamics and lo cal sediment transport. A large hypothetical WEC array was investigated using wave, hydrodynamic, and sediment transport models and site - specific average and storm conditions as input. The results indicated that there were significant changes in sediment s izes adjacent to and in the lee of the WEC array due to reduced wave energy. The circulation in the lee of the array was also altered; more intense onshore currents were generated in the lee of the WECs . In general, the storm case and the average case show ed the same qualitative patterns suggesting that these trends would be maintained throughout the year. The framework developed here can be used to design more efficient arrays while minimizing impacts on nearshore environmen ts.

Roberts, Jesse D.↗

Coupled optical/thermal/fluid analysis and design requirements for operation and testing of a supercritical CO 2 solar receiver.

Recent studies have evaluated closed-loop supercritical carbon dioxide (s-CO 2 ) Brayton cycles to be a higher energy-density system in comparison to conventional superheated steam Rankine systems. At turbine inlet conditions of 923K and 25 MPa, high thermal efficiency (~50%) can be achieved. Achieving these high efficiencies will make concentrating solar power (CSP) technologies a competitive alternative to current power generation methods. To incorporate a s-CO 2 Brayton power cycle in a solar power tower system, the development of a solar receiver capable of providing an outlet temperature of 923 K (at 25 MPa) is necessary. To satisfy the temperature requirements of a s-CO 2 Brayton cycle with recuperation and recompression, it is required to heat s-CO 2 by a temperature of ~200 K as it passes through the solar receiver. Our objective was to develop an optical-thermal-fluid model to design and evaluate a tubular receiver that will receive a heat input ~1 MWth from a heliostat field. We also undertook the documentation of design requirements for the development, testing and safe operation of a direct s-CO 2 solar receiver. The main purpose of this document is to serve as a reference and guideline for design and testing requirements, as well as to address the technical challenges and provide initial parameters for the computational models that will be employed for the development of s-CO 2 receivers.

14 SOLAR ENERGY↗

Fort Mason Center: Pier 2 Project

The rooftop Photovoltaic (PV) panels and radiant piping project was constructed by Fort Mason Center as part of its $21 million comprehensive rehabilitation of the Pier 2 shed which include the shed’s electrical, natural gas and water systems. Fort Mason Center improved performance while reducing energy and water usage and costs to demonstrate the efficiencies and opportunities available to large multi-function facilities. The scalable demand of these facilities required a layered approach to conservation, control and production. The project employed a comprehensive retrofit of electrical natural gas, and plumbing systems to maximize efficiency and lower carbon footprint specifically to demonstrate the effectiveness of these strategies in a public setting with varied and diverse use. The project was completed in July 2014 and met the expected outcomes regarding increased comfort and operational efficiency throughout the Pier 2 shed as well as on site electrical generation of current consumption. The entire Pier 2 shed project won a 2015 California Preservation Foundation design award for historic rehabilitation.

14 SOLAR ENERGY↗

Addendum to the Maximum Current of the Linac

The purpose of this technical note is to supplement the information provided in NSLS-II Technical Note 105: Maximum Current of the NSLS-II Linac. This is included in the Linac Commissioning SAD Addendum as Appendix B. Technical Note 105 made some assumptions which have been subjected to further analysis. This technical note will reexamine some of these assumptions. This technical note includes additional analysis of: 1. Updated PARMELA model of the linac 2. Updated beam loading model 3. Gun faults which lead to full discharge of the gun and high voltage deck 4. Consideration of the case where the gun can emit more charge than has been measured by manufacturer, but within cathode specifications. In all cases the linac ASE is not violated either of operation because not enough current is generated or recovery from the fault will take enough time that violating the ASE is not possible.

36 MATERIALS SCIENCE↗

Combined microscopy studies of complex electronic materials. Final report

The aim of this project was to study the electronic properties of exotic electronic materials which are only available as micron-scale samples or have microscopic inhomogeneity, using a special combination of multiple submicron scanning microscopy techniques allied to control of temperature, magnetic and electric fields and mechanical strain. In nanobeams of VO 2 , with its still mysterious metal-insulator phase transition, we determined the phase diagram and demonstrated that hydrogen diffusion is strongly channelled along one crystal axis. Using graphene, we developed and applied the scanning photo-Nernst effect, in which a current is generated when a laser is focused on the edge a sample in a magnetic field. We demonstrated that CrI 3 , a two-dimensional layered magnet, retains true Ising ferromagnetization down the monolayer level due to its out-of-plane anisotropy. In exfoliated WTe 2 , a layered topological semimetal, we discovered that monolayers are the first monolayer topological insulator and we imaged the helical edge states with scanning microwave microscopy. We also discovered that the same material when stacked in a few layers is a ferroelectric metal, and that the monolayer can be converted to a superconducting state by electron doping with a gate a temperatures below 1 K. Additionally, we developed the capability to perform momentum-resolved electronic spectroscopy on operating nanoscale devices by applying micron-scale angle resolved photoemission spectroscopy to two-dimensional heterostructure devices incorporating graphene and transition metal dichalcogenide semiconductors. Using it, we measured the band gaps of a series of monolayer semiconductors and observed band renormalization as a function of electron doping in monolayer WSe 2 .

36 MATERIALS SCIENCE↗

Measuring Magnetic Fields in Collisionless Experiments

Magnetic field and electron density diagnostics are critical tools in the characterization of high energy density laboratory plasmas. These plasma environments are complex and the magnetic fields and electron densities often exhibit significant spatial and temporal variation leading to significant challenges in these measurements. Even the most promising technique, Zeeman splitting, faces challenges under plasma conditions where broadening due to high density and temperature is greater than the Zeeman splitting. Here we propose and describe a diagnostic based on Zeeman broadening. The Zeeman broadening diagnostic relies on measuring the widths of multiplet components simultaneously. The method does not depend on resolved lines, but rather on measuring the difference in the widths of multiplet lines. Experiments were performed at the University of Nevada, Reno, Nevada Terawatt Facility (NTF). The Zeeman broadening diagnostic gathered visible broadened multiplet spectra from laser produced plasmas, and plasmas generated from wire-arrays driven by the Zebra z-pinch pulsed power apparatus. The laser produced plasma, created by the Leopard pulsed laser (I>1014 W/cm 2 ), evolved in an external magnetic field (B<40T) generated by current driven through a solid electrode by the Zebra current pulse. For laser produced plasmas, observation of the magnetic field radial profile showed that the external field completely diffuses into the plasma after approximately 100 ns. Further, as the plasma continues to evolve, the field profiles within the plasma develop modulations that do not map the external field profile. For the wire array experiments, radial electron density, and magnetic field, profiles were measured. Here the Zeeman splitting was not resolved and the magnetic fields were determined from the difference between the widths of the multiplet line profiles. Thus, it has been demonstrated that Zeeman broadening may be used as a magnetic field diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mysteries of Nuclear Fusion: How can we build a star on Earth? [Slides]

This presentation given at the Women's Physics Summer Camp focuses on nuclear fusion as an alternative to fossil fuels, renewable energy sources and nuclear fission energy. The presentation explains plasma physics and how it might be used to generate power. Current attempts and potential applications are outlined. An appeal is made for people trained in mathematics, physics, chemistry, engineering, computer science to solve these problems. If technical problems can be overcome, fusion technology will play a part in a clean, prosperous Earth and expand humanity’s reach to the stars.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Scalable Solution Framework for Stochastic Transmission and Generation Planning Problems. Draft

Current commercial software tools for transmission and generation investment planning have limited stochastic modeling capabilities. Because of this limitation, electric power utilities generally rely on scenario planning heuristics to identify potentially robust and cost effective investment plans for a broad range of system, economic, and policy conditions. Several research studies have shown that stochastic models perform significantly better than deterministic or heuristic approaches, in terms of overall costs. However, there is a lack of practical solution approaches to solve such models. In this paper we propose a scalable decomposition algorithm to solve stochastic transmission and generation planning problems, respectively considering discrete and continuous decision variables for transmission and generation investments. Given stochasticity restricted to loads and wind, solar, and hydro power output, we develop a simple scenario reduction framework based on a clustering algorithm, to yield a more tractable model. The resulting stochastic optimization model is decomposed on a scenario basis and solved using a variant of the Progressive Hedging (PH) algorithm. We perform numerical experiments using a 240-bus network representation of the Western Electricity Coordinating Council in the US. Although convergence of PH to an optimal solution is not guaranteed for mixed-integer linear optimization models, we find that it is possible to obtain solutions with acceptable optimality gaps for practical applications. Our numerical simulations are performed both on a commodity workstation and on a high-performance cluster. The results indicate that large-scale problems can be solved to a high degree of accuracy in at most two hours of wall clock time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Pressure Electron Gun for Electron Beam Welding and Additive Manufacturing

Electron beam welding is a premier technology for high quality welding. However, e-beam welding is viewed as very expensive method for quality results. Therefore, it is often the last choice for joining metals. U.S. Electron is developing a technology that changes the welding environment. As a result of this pursuit of technology, e-beam welding can be field deployable. U.S. Electron has received a DOE SBIR Phase I grant to demonstrate a proof of principle that the plasma cathode can be installed in an electron gun housing, generate a current and energy enough to weld stainless steel. Under this CRADA, Fermilab proposed to provide a power supply, the necessary safety expertise and the physical location for testing of the initial prototype equipment developed by U.S. Electron.

43 PARTICLE ACCELERATORS↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review and Summary of Oxide Thickness Data for Aluminum-Clad Spent Nuclear Fuel

The U.S. Department of Energy (DOE) owns a large inventory of aluminum-clad spent nuclear fuel (ASNF) in interim storage pending ultimate disposition, with more being generated by currently operating research reactors. Dry storage in sealed DOE Standard Canisters is being investigated as an approach for long-term interim storage and/or disposition in a repository for ASNF. A primary challenge for ASNF storage is the presence of aluminum (oxy)hydroxide layers formed on the cladding surfaces during water exposure in the reactor and in wet storage, which forms a reservoir of chemisorbed water not readily removed at low (<100°C) drying temperatures. Free, physisorbed, and chemisorbed water are all susceptible to radiolytic breakdown under irradiation and can release hydrogen gas. Identifying the likely range of (oxy)hydroxide loadings on ASNF that may be placed in dry storage will help to ensure that the impact of the (oxy)hydroxide is adequately accounted for while avoiding over conservatism and enable mitigation strategies to be implemented where needed. The current report summarizes information on (oxy)hydroxide thicknesses and characteristics from the literature and from recent measurements taken in the present research campaign. In general, corrosion studies have indicated that the corrosion and oxide buildup on aluminum are affected by numerous conditions, including pH, temperature and heat flux, coolant flowrates, irradiation (in-reactor vs. unirradiated tests), duration of water exposure, and the amount of oxide already on the surface. Some of these factors are interrelated (e.g., the local temperature, heat flux, and coolant flowrate). Observations of the impact of irradiation (in-reactor versus ex-reactor measurements) on corrosion and oxide thickness are mixed, but multiple studies indicate that there is a significant difference between in-reactor and ex-reactor corrosion kinetics, even when other operating conditions such as pH, flowrate, heat flux, etc., simulate those in a reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DSO+T: Expanded Study Results DSO+T Study: Volume 5

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. This report volume provides a detailed set of results for the DSO+T study extending results presented in Volumes 1, 2, and 4. The engineering and economic performance of the transactive energy scheme is presented for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DPE Techno-Economic Analyses

This National Energy Technology Laboratory (NETL) report presents the results of an extensive set of techno-economic analyses for several open-cycle coal fuel oxy-fired direct power extraction (DPE) concepts. These power cycles make use of a conducting plasma accelerated through a magnetic field to generate direct current directly without the need for moving parts. Similar to gas turbines, the efficiency of the power cycle increases with increasing working fluid temperature and typically, plasma temperatures are much higher than the inlet temperature of even the most advanced gas turbine available today, affording the opportunity for very high cycle efficiencies. Most of the study uses high-fidelity models to assess a coal-fueled oxy-combustion DPE system with an AUSC steam bottoming cycle. Two baseline configurations were explored, one with relatively conservative operating point parameters and another with relatively aggressive operating point parameters. Additional analysis on the high-fidelity models as well as reduced order models were performed to analyze the cost and performance potential more thoroughly for the baseline systems and to compare their performance to two alternate open-cycle DPE systems.

30 DIRECT ENERGY CONVERSION↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

An FSI Reweighter for 𝑣 Interactions on Heavy Nuclei

Final State Interaction (FSI) processes in $\nu$--Pb differ significantly from those in neutrino--carbon ($\nu$--C), and MINER$\nu$A is particularly sensitive to these differences, especially in pion absorption. This work develops an FSI reweighting method for $\nu$--Pb (and C) interactions in MINER$\nu$A. We compare GENIE~2, the currently used generator version, with GENIE~3 predictions of the initial hadron energy as a function of FSI fate, and apply these weights to simulated observables. We identify changes in the FSI composition, providing a framework for estimating FSI-related systematic uncertainties and interpreting their effects in the data.

Moreno-Palacios, Oscar [Coll. William and Mary]↗