Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A tunable dielectric resonator for axion searches at 11 GHz

In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive and no-loss weather cap for protection of wind induced downdraft in sensitive exhaust system

The invention provides a device for removing heat from a building, the device having: a first tubular member defining a first cavity; a second tubular member defining a second cavity, whereby said second tubular member resides within the first cavity and is coaxial to the first tubular member; a double conic body coaxially residing in the first cavity and coaxially positioned with the second tubular member; and a flange dimensioned to extend over at least a portion of the periphery of the existing flue so as to aid in supporting the device on the flue.

Lisowski, Darius D.↗

Quantum computing structures and resonators thereof

Embodiments disclosed herein include a resonator for use in quantum computing. The resonator can include a housing that is disposed along a resonator axis. The housing can have a first portion extending from a housing distal end to near a qubit location and a second portion extending from near the qubit location to a housing proximal end. The housing can define a cavity extending from a cavity proximal end to a cavity distal end along a portion of the resonator axis. The housing can include a protrusion extending axially from the housing distal end along the resonator axis to near the qubit location. A proximal portion of the protrusion can include a tapered portion. The resonator can include a qubit extending into the cavity at the qubit location.

Kutsaev, Sergey↗

LLRF System Analysis for the Fermilab PIP-II Superconducting LINAC

PIP-II is a superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of cavities with five different acceleration \(β\). The LLRF system for the linac has to provide field and resonance control for a total of 125 RF cavities. Various components of the LLRF system have been tested with and without beam at the PIP-II test stands. The LLRF system design is derived from the LCLS-II project with its self-excited loop architecture used in the majority of the cryo-modules. The PIP-II beam loading at 2 mA is much higher than the LCLS-II linac. The control system architecture is analyzed and evaluated for the operational limits of feedback gains and their ability to meet the project regulation requirements for cavity field amplitude and phase regulation.

Varghese, P. [Fermilab] (ORCID:0009000925131983)↗

Autonomous Coupler Alignment Using Position-Based Visual Servoing in a ROS 2 Framework

As robotic arms are becoming increasingly common alongside humans as collaborative robots, their high precision in motion enables tasks to be performed at significantly higher speeds with reduced disruption in the environment. The Fermi National Accelerator Laboratory is exploring this application by incorporating a UR16e from Universal Robots in a cleanroom setting during assembly of couplers to superconducting radio frequency cavities as part of the PIP-II project. The goal of the robotic assembly process is to precisely position the UR16e robot so that the coupler flange, mounted on the robot’s end-effector, is accurately aligned with and pressed against the cavity flange, requiring only final fastening by a lab technician. This thesis builds upon an initial system in which the robotic process was limited to the alignment phase using position-based visual servoing with an eye-in-hand camera to only align the coupler to the cavity with an offset distance. The objective of this thesis is to further advance autonomous robotic assembly by extending the process. To this end, the entire software framework was reconstructed, as the previous development environment posed significant challenges in modifying the software and adapting to hardware changes. The main contributions of this thesis are as follows: (i) a modular and scalable software framework based on ROS~2 was developed to facilitate performance expansion and interchangeability of software and hardware components; (ii) the desired alignment position for position-based visual servoing was parameterized to enable flexible configuration; and (iii) a methodology was developed to close the offset distance between the coupler and cavity utilizing the internal force-torque sensing capability of the UR16e, as visual feedback is not available during the offset-closing phase. The proposed autonomous robotic assembly reduces assembly time and technician involvement, thereby minimizing the risk of airborne particulate contamination, which is essential in the cleanroom setting. Moreover, the ROS~2-based framework provides a foundation for further expansion and continued advancement of robotic automation in Fermilab.

Giffen, Nickolas [Northern Illinois U.]↗

Thermalization of Fluorescent Protein Exciton–Polaritons at Room Temperature

Fluorescent proteins (FPs) have recently emerged as a serious contender for realizing ultralow threshold room temperature exciton–polariton condensation and lasing. Here, this contribution investigates the thermalization of FP microcavity exciton–polaritons upon optical pumping under ambient conditions. Polariton cooling is realized using a new FP molecule, called mScarlet, coupled strongly to the optical modes in a Fabry–Pérot cavity. Interestingly, at the threshold excitation energy (fluence) of ≈9 nJ per pulse (15.6 mJ cm –2 ), an effective temperature is observed, T eff ≈ 350 ± 35 K close to the lattice temperature indicative of strongly thermalized exciton–polaritons at equilibrium. This efficient thermalization results from the interplay of radiative pumping facilitated by the energetics of the lower polariton branch and the cavity Q-factor. Direct evidence for dramatic switching from an equilibrium state into a metastable state is observed for the organic cavity polariton device at room temperature via deviation from the Maxwell–Boltzmann statistics at k || = 0 above the threshold. Thermalized polariton gases in organic systems at equilibrium hold substantial promise for designing room temperature polaritonic circuits, switches, and lattices for analog simulation.

36 MATERIALS SCIENCE↗

Emulation of neutron-irradiated microstructure of austenitic 21Cr32Ni model alloy using dual-ion irradiation

Here, in this study, the capability of heavy-ion irradiation to emulate neutron irradiation was demonstrated on an austenitic 21Cr32Ni type ternary model alloy. The model alloy used in this study is chemically analogous but compositionally simpler than of alloy 800H, which is a candidate austenitic Ni alloy which has been proposed for use in Generation IV reactors. The microstructure of the 21Cr32Ni model alloy irradiated in the BOR-60 fast reactor to 17.1 dpa and 35 dpa at ~380°C was characterized using transmission electron microscopy (TEM). The 17.1 dpa BOR-60 irradiated microstructure was then compared with the microstructure of the same material developed under dual-ion (DI) irradiation using various He/dpa ratios between 0.1 and 16.6 appm He/dpa in the temperature range of 430°C-500°C. The results showed that both neutron and DI irradiation of 21Cr32Ni model alloy produced dislocations in the form of a dislocation network as well as {111}-type faulted dislocation loops, cavities, and radiation-induced Ni enrichment at radiation-induced sinks. When the dose and the He/dpa ratio were kept similar to those in neutron irradiation, DI irradiation of the 21Cr32Ni model alloy at 460°C resulted in over-nucleation of small cavities and in a high density of faulted dislocation loops compared to those observed in the fast-neutron irradiated alloy of the same heat irradiated at ~380°C. The optimal condition for reproducing the neutron-irradiated microstructure was DI irradiation at 460°C and 0.1 appm He/dpa. In that case, the faulted loop and cavity size distributions in the BOR-60 irradiated 21Cr32Ni model alloy samples closely matched with those measured in the DI irradiated 21Cr32Ni model alloy sample. The fact that the He/dpa is an order of magnitude smaller than the helium generation rate for fast neutron irradiation, stops over nucleation and allows for the development of a similar microstructure as for neutron irradiation.

21Cr32Ni model alloy↗

Recent Improvements to the NWChem COSMO Module

This work presents recent developments in the COSMO solvation model implementation in NWChem. A new cavity construction approach, based on the solvent-excluding surface (SES) and utilizing the well-established GEPOL algorithm, has been introduced. Additionally, a straightforward procedure to merge surface segments that are too close─often a source of numerical artifacts─has been implemented. The available methods for correcting outlying surface charges have also been reviewed and improved. To validate the new implementation, we computed dielectric solvation energies for a chemically diverse set of approximately 100 molecules, including neutral species, small ions, and common ionic liquid components. Results were compared to those from GAMESS using the double-cavity method as a reference. Although the double-cavity approach can be regarded as more accurate, the simpler correction schemes available in NWChem─based on scaling factors or Lagrange multipliers─can achieve excellent agreement if the potential is also properly corrected, with mean unsigned deviations of around 0.15 kcal/mol. Predictions of typical vapor–liquid and liquid–liquid equilibria using a COSMO-SAC variant based on NWChem also showed very promising results.

Cavities↗

Electrons and Their Multiple Kinetic Fates in an Ionic Liquid

Ionic liquids (ILs) for electrochemical, nuclear, and solar energy applications operate under harsh conditions, where electrons and transient radical species can form. This communication discusses why anions such as bis(trifluoromethylsulfonyl)imide (Tf 2 N − ) are reduced at the electron-rich electrode whereas in laser photoionization or pulse radiolysis studies, where electrons are ejected from species in the bulk, we often detect long-lived electrons in cavities that interact with IL cations instead. This work argues that bulk excess electrons generated photolytically or radiolytically follow kinetically favored pathways. As such, cavity electrons may not be the most energetically favorable states, but when they form, and they do form, they are kinetically stable. Reduction reactions of anions or electron localization in cavities and subsequent reactions are all expected outcomes. Here we focus on a pyrrolidinium-based IL of the dicyanamide (N(CN) 2 − ) anion because of its large electrochemical window and very low viscosity, which are ideal for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen-Bonded Organic Framework Enables Phase-Pure Layered Tin Perovskite Nanowires for Room-Temperature Lasing

Room-temperature lasing is a key milestone in the development of miniaturized optoelectronic and photonic devices. We present a simple approach to synthesize phase-pure quasi-2D layered tin perovskite nanowires with varying quantum well thicknesses (n = 1 to 4). By incorporating a new organic spacer capable of forming a hydrogen-bonded organic framework, this method promoted anisotropic crystal growth and enhanced lattice rigidity. Furthermore, introducing molecular intercalants enabled controlled crystallization into well-defined nanowires that function as Fabry−Pérot cavities. Cavities made from n = 2 to 4 perovskites support efficient and robust nearinfrared, room-temperature optically pumped lasing with the threshold as low as 75.8 μJ/cm 2 , cavity quality factor over 3000, and negligible degradation over 106 pulses. A cleaved coupled nanolaser was fabricated as a proof-of-concept device for photonic applications.

Cavities↗

Spray Mechanism of Contained-Electrospray Ionization

Analytical characteristics of contained electrospray ionization (ESI) are summarized in terms of its potential to modify the analyte solution during the stages of droplet formation to provide opportunities to generate native versus denatured biomolecular gas-phase ions, without the need for bulk-phase analyte modifications. The real-time modification of the charged microdroplets occurs in a cavity that is included in the outlet of the contained-ESI ion source. Close examination of the inside of the cavity using a high-speed camera revealed the formation of discrete droplets as well as thin liquid films in the droplets wake. When operated at 20 psi N2 pressure, the droplets were observed to move at an average speed of 8 mm/s providing ~1 s mixing time in a 10 mm cavity length. Evidence is provided for the presence of highly reactive charged droplets based on myoglobin charge state distribution, apo-myoglobin contents, and ion mobility drift time profiles under different spray conditions. Mechanistic insights for the capture of vapor-phase reagents and droplet dynamics as influenced by different operational modes are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Population inversion X-ray laser oscillator

Oscillators are at the heart of optical lasers, providing stable, transform-limited pulses. Until now, laser oscillators have been available only in the infrared to visible and near-ultraviolet (UV) spectral region. In this paper, we present a study of an oscillator operating in the 5- to 12-keV photon-energy range. We show that, using the Kα 1 line of transition metal compounds as the gain medium, an X-ray free-electron laser as a periodic pump, and a Bragg crystal optical cavity, it is possible to build X-ray oscillators producing intense, fully coherent, transform-limited pulses. As an example, we consider the case of a copper nitrate gain medium generating ~ 5 × 10 10 photons per pulse with 37-fs pulse length and 48-meV spectral resolution at 8-keV photon energy. Our theoretical study and simulation of this system show that, because of the very large gain per pass, the oscillator saturates and reaches full coherence in four to six optical-cavity transits. We discuss the feasibility and design of the X-ray optical cavity and other parts of the oscillator needed for its realization, opening the way to extend X-ray–based research beyond current capabilities.

47 OTHER INSTRUMENTATION↗

Floquet-engineered fast SNAP gates in weakly coupled circuit-QED systems

Superconducting cavities with high quality factors, coupled to a fixed-frequency transmon, provide a state-of-the-art platform for quantum information storage and manipulation. The commonly used selective number-dependent arbitrary phase ( SNAP ) gate faces significant challenges in ultrahigh-coherence cavities, where the weak dispersive shifts necessary for preserving high coherence typically result in prolonged gate times. Here, in this work, we propose a protocol to achieve high-fidelity SNAP gates that are orders of magnitude faster than the standard implementation, surpassing the speed limit set by the bare dispersive shift. We achieve this enhancement by dynamically amplifying the dispersive coupling via sideband interactions, followed by quantum optimal control on the Floquet-engineered system. We also present a unified perturbation theory that explains both the gate acceleration and the associated benign drive-induced decoherence, corroborated by Floquet-Markov simulations. These results pave the way for the experimental realization of high-fidelity, selective control of weakly coupled, high-coherence cavities, and expanding the scope of optimal control techniques to a broader class of Floquet quantum systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupled surface plasmon–phonon polariton nanocavity arrays for enhanced mid-infrared absorption

Abstract Resonant optical cavities are essential components in mid-infrared applications. However, typical film-type cavities require multilayer stacks with a micron-thick spacer due to mid-infrared wavelengths, and their performance is limited by narrow frequency tunability and angular sensitivity. We propose and experimentally demonstrate the subwavelength-scale (≈ λ 0 /150) resonant nanocavity arrays that enhance the absorption spectrum of the device in the mid-infrared (10–12 microns) via excitation of coupled surface plasmon–phonon polaritons. The proposed metal–insulator–polar dielectric (gold–silicon–silicon carbide) structure supports a guided mode of the coupled surface polaritons in the lateral direction while vertically confining the mid-infrared wave within the 80 nm thick dielectric spacer. In particular, the subwavelength-scale (≈ λ 0 /10) gratings are imposed to form Fabry–Pérot cavity arrays displaying angle-insensitive and frequency-tunable absorption of up to 80% of the optical power in the mid-infrared. Our work should benefit diverse mid-infrared applications and novel designs of polariton-based photonic devices.

42 ENGINEERING↗

Liquid helium fluid dynamics studies. Final Technical Report

Future high energy physics accelerators depend on a number of advanced technologies to open the many doors of scientific discovery. Among these advanced technologies, superconducting magnets and superconducting radio frequency (SRF) cavities are the backbone of the accelerator and detector systems. But all these low temperature systems depend critically on successful and reliable operation of their supporting technologies, among which the liquid helium cooling system is of the utmost importance. To improve the quality of these systems both in terms of efficiency and reliability, a robust helium cryogenics research and development (R&D) effort is required. The proposed research to be conducted by the FSU cryogenics group aims to produce fundamental knowledge that meets this R&D need. The projects that we have completed over the past grant period at Florida State University consist of experimental research on liquid helium fluid dynamics and heat transfer problems relevant to the development of future superconducting particle physics accelerators. Liquid helium is the coolant used in all such facilities and in many of these facilities He II (the low temperature phase of liquid helium also known as superfluid helium) is preferred due to its outstanding heat transfer characteristics. The work consists of two main experimental studies that probe both fundamental as well as practical aspects of liquid helium cooling. The first is a broad and fundamental study of the heat and mass transfer processes that can occur during a sudden catastrophic loss of vacuum (SCLV) incident in a superconducting accelerator. SCLV refers to the remote but extremely critical accident scenario where atmospheric pressure air is allowed to flood into the insulating vacuum system and impinge on the liquid helium cooled surfaces in the accelerator. Safe performance and recovery from such accidents is essential to the reliable operation of superconducting accelerators. The dynamics of this process is quite complex and so our approach is to conduct a series of well-orchestrated experiments that probe the various physical phenomena that can occur during an SCLV event. The experiments are coupled with analytic and numerical analysis in an effort to develop a general understanding of the process and to assist with future accelerator design and development. The second activity is directed toward fundamental understanding of heat and mass transfer in He II, which is essential to the design of superconducting magnets and radio frequency cavities in accelerators. The work consists of flow visualization of the dynamics of He II using laser assisted techniques. Two complementary techniques are used to study the fundamentals of the turbulent state. The first technique uses neutrally buoyant solid hydrogen particles to probe the flow fields of the superfluid and normal fluid components. The other technique uses laser excited He2* molecules as tracers of the normal fluid motion within the He II. The activities also included an effort to use visualization techniques to locate transient hot spots in radio frequency superconducting cavities. Such work provides valuable information about the heat transfer process in He II and its impact on the performance of superconducting devices. The research effort at Florida State University is not directly in support of a specific high energy physics experiment or facility. Rather, the work is general and coordinated with HEP accelerator laboratories to provide valuable insight that can assist with future accelerator development.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NREL Pyrheliometer Comparisons: September 23 - September 28, 2023 (NPC-2023)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, for improving our understanding of Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ACR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an quinquennial International Pyrheliometer Comparison (IPC) event for transferring the WRR to participating radiometers by invitation. The National Renewable Energy Laboratory (NREL) has represented the U.S. Department of Energy (DOE) in each IPC since 1980. And NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and it uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025-accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.

14 SOLAR ENERGY↗