Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Spas color camera

The procedures to be followed in assessing the performance of the MOS color camera are defined. Aspects considered include: horizontal and vertical resolution; value of the video signal; gray scale rendition; environmental (vibration and temperature) tests; signal to noise ratios; and white balance correction.

Toffales, C.↗

Image dissector camera system study

Various aspects of a rendezvous and docking system using an image dissector detector as compared to a GaAs detector were discussed. Investigation into a gimbled scanning system is also covered and the measured video response curves from the image dissector camera are presented. Rendezvous will occur at ranges greater than 100 meters. The maximum range considered was 1000 meters. During docking, the range, range-rate, angle, and angle-rate to each reflector on the satellite must be measured. Docking range will be from 3 to 100 meters. The system consists of a CW laser diode transmitter and an image dissector receiver. The transmitter beam is amplitude modulated with three sine wave tones for ranging. The beam is coaxially combined with the receiver beam. Mechanical deflection of the transmitter beam, + or - 10 degrees in both X and Y, can be accomplished before or after it is combined with the receiver beam. The receiver will have a field-of-view (FOV) of 20 degrees and an instantaneous field-of-view (IFOV) of two milliradians (mrad) and will be electronically scanned in the image dissector. The increase in performance obtained from the GaAs photocathode is not needed to meet the present performance requirements.

Howell, L.↗

In-situ measurements of alloy oxidation/corrosion/erosion using a video camera and proximity sensor with microcomputer control

Two noncontacting and nondestructive, remotely controlled methods of measuring the progress of oxidation/corrosion/erosion of metal alloys, exposed to flame test conditions, are described. The external diameter of a sample under test in a flame was measured by a video camera width measurement system. An eddy current proximity probe system, for measurements outside of the flame, was also developed and tested. The two techniques were applied to the measurement of the oxidation of 304 stainless steel at 910 C using a Mach 0.3 flame. The eddy current probe system yielded a recession rate of 0.41 mils diameter loss per hour and the video system gave 0.27.

Deadmore, D. L.↗

High resolution bone mineral densitometry with a gamma camera

A technique by which the regional distribution of bone mineral can be determined in bone samples from small animals is described. The technique employs an Anger camera interfaced to a medical computer. High resolution imaging is possible by producing magnified images of the bone samples. Regional densitometry of femurs from oophorectomised and bone mineral loss.

Leblanc, A.↗

High spatial resolution observations of NGC 7027 with a 10 micron array camera

First observations of a planetary nebula with an infrared charge injection device (CID) array camera are reported. The 10 micron images of NGC 7027 have spatial resolution comparable to that of the highest resolution (less than 2 arcsec) radio aperture-synthesis maps of this source. A much closer correspondence between the mid-infrared and radio appearance of NGC 7027 was found than was known previously, confirming that warm dust is coextensive and well mixed with the gas in the ionized zone. Using maps at three wavelengths, the spatial dependence of the shape of the 8-13 micron spectrum within the nebula is examined. The dip at 9.60 microns is shallowest in regions of enhanced optical extinction (as determined from new images near 4000 and 9000 A obtained with an optical charge coupled device). The 9.60 micron emission is strongest in these same positions. It is shown that the results may be explained not by silicate absorption, but by a combination of emission from two distinct grain populations, one of which is also partly responsible for the variation in extinction across the nebula.

Arens, J. F.↗

Wide-Angle, Wide-Band Camera for Remote Imaging

Improved ultraviolet-to-infrared camera design combines high resolution and relatively wide field of view in remote-imaging system. Although design intended for satellite-borne system to give information on such Earth features as vegetation, pollution, and land formation mineral deposits, optical principle also useful in ground-based or airborne high-resolution television for imaging objects at great distances.

Atcheson, P. D.↗

Time Series Photometry with a CCD Camera

Time series observations of a field in the cluster NGC 4755 with a CCD camera are used to show that differential photometry between stars on the CCD frame is limited in accuracy mostly by photon statistics, over a 5 magnitude range. Scintillation noise appears to be almost entirely suppressed. The maximum accuracy possible is limited by the storage capacity of the CCD to about 0.001 mag.

Walker, A. R.↗

Astronomical applications of the new Goddard Si:Bi 16 x 16 array camera system

An improved 4-18 micron array camera system has been developed at NASA Goddard Space Flight Center for astronomical protometry, using 16 x 16 Si:Bi (bismuth dope silicon) accumulation mode charge injection device (AMCID) with 256 active pixels. An astronomical observing program using this device has been carried out. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Steward Observatory Mt. Lemmon 60 and 61-inch telescopes in May 1983, and at the NASA Infrared Telescope Facility (IRTF) at Mauna Kea in August 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.

Lamb, G.↗

Results from the transition region camera

Three series of high resolution ultra-violet pictures of the sun have been obtained during the three flights of rocket experiment T.R.C. Transition Region Camera) which took place on 3 July 1979, 23 September 1980 and 13 July 1982. These pictures reveal many structures in Ly alpha and ultraviolet continua at 160 nm and 220 nm. The scientific objectives, instrumentation, flight conditions and campaigns of simultaneous observations are described. The contribution of T.R.C. to solar physics is discussed in the framework of chromospheric multicomponent models, magnetic flux tubes, local heating and periodic structures in the chromosphere.

Foing, B. H.↗

Wind dynamic range video camera

A television camera apparatus is disclosed in which bright objects are attenuated to fit within the dynamic range of the system, while dim objects are not. The apparatus receives linearly polarized light from an object scene, the light being passed by a beam splitter and focused on the output plane of a liquid crystal light valve. The light valve is oriented such that, with no excitation from the cathode ray tube, all light is rotated 90 deg and focused on the input plane of the video sensor. The light is then converted to an electrical signal, which is amplified and used to excite the CRT. The resulting image is collected and focused by a lens onto the light valve which rotates the polarization vector of the light to an extent proportional to the light intensity from the CRT. The overall effect is to selectively attenuate the image pattern focused on the sensor.

Craig, G. D.↗

Hall station and camera system operation and maintenance manual

The major components of the Hall station and camera system are described. The Hall film record of an event provides the time of flight of the projectile between the slits. A time mark generator is used to supply extremely short pulses of light at a known frequency. These pulses of light are used to produce timing marks on the edge of the film. Comparison of these marks with the spacing of the projectile images provides the information necessary to determine the time of flight of the projectile. Since the slits are installed with a known separation distance, calculation of the velocity of any object passing both slits is a simple matter.

Piekutowski, A. J.↗

First Halley multicolour camera imaging results from Giotto

The Giotto spacecraft's Halley Multicolor Camera imaging results have furnished flyby images that are centered on the brightest part of the inner coma; these show the silouette of a large, solid and irregularly shaped cometary nucleus and jetlike dust activity. The preliminary assessment of these data has yielded information on the dimensions and shape of the nucleus and dust emission activity. It is noted that only minor parts of the surface are active, with most of the surface being covered by a nonvolatile material. Dust jets dominate the inner coma, and are restricted to a subsolar hemisphere.

Keller, H. U.↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

IRAC focal plane detector technology was developed and studies of alternate focal plane configurations were supported. While any of the alternate focal planes under consideration would have a major impact on the Infrared Array Camera, it was possible to proceed with detector development and optical analysis research based on the proposed design since, to a large degree, the studies undertaken are generic to any SIRTF imaging instrument. Development of the proposed instrument was also important in a situation in which none of the alternate configurations has received the approval of the Science Working Group.

Fazio, G. G.↗

Development of InSb and Si:Ga arrays for ISO camera

The Infrared Space Observatory (ISO) satellite will contain a 60 cm telescope. A 4 faces pyramid mirror feeds each experiment with a 3 arc minute part of the telescope field of view. The camera system is described. The arrays for the 3 to 5 and 5 to 17 micron channel are also discussed.

Sibille, F.↗

Dust-gas interaction deduced from Halley multicolor camera observations

The dust and gas productions of comet Halley were measured by the dust counter and the mass spectrometers on the Giotto spacecraft. These instruments give only little information about the spatial asymmetry of the activity. The asymmetry in the dust production is clearly evident from the dust jets seen in the Halley Multicolor Camera images. Since the dust is entrained by the gas, gas production must be similarly asymmetric. The intensity profiles along and across several dust jets are related to their source regions on the nucleus. Properties of the dust jets are investigated. A few compact, but highly active source regions on the nucleus produce most of the visible dust and can account for most of the gas produced by the comet.

Huebner, W. F.↗