Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Development of in-use engine speed/torque heat maps across multiple heavy-duty commercial vehicle vocations

The U.S. Department of Energy (DOE) established the SuperTruck program with the goal of achieving brake thermal efficiency (BTE) greater than or equal to 55% as demonstrated in an operational heavy-duty (HD) diesel engine at a 65-miles-per-hour (mph) cruise point. Beyond the line-haul application, HD engines operate in a wide range of speed and torque conditions that are unlikely to yield the same efficiency under real-world operation. Thereby, the in-use engine heat maps described in this paper are a valuable tool to illustrate whether the engine-efficiency “sweet spot” matches the most frequent operating conditions. In this study, NREL developed engine heat maps to quantify the important operating points for various vocations using our Fleet DNA database of commercial fleet vehicle operations data. These heat maps clearly show that high-frequency operating points vary significantly according to vehicle vocation, while only a few of them match the sweet spot. Beyond the illustration, engine in-use heat maps can also be leveraged to build up reduced-order engine-efficiency models, needed by many rapid powertrain simulations. As case studies, nine reduced-order models – including line-haul truck, transfer truck, transit bus, transit bus with compressed natural gas (CNG) engine, drayage, refuse pickup, local delivery, utility truck, and school bus with CNG engine – using a trust-region reflective algorithm to fit the on-road data extracted based on the engine in-use heat maps.

33 ADVANCED PROPULSION SYSTEMS↗

Smart Planning Support for Nuclear Power Plant Work Planners

Operation and Maintenance costs of a nuclear power plant account for 60% of overall plant costs due to the nuclear industry?s risk-adverse culture (World Nuclear Association, 2020). The industry relies on highly conservative estimates to avoid risk and brute force reactions to manage the unexpected and keep a plant running safely. This approach has kept plants operating safer than any other power source available over the last six decades (Ritchie, 2020). However, these conservative methods have cost the nuclear industry in market competitiveness. The solution? Transform the conservative approaches to accurate, efficient, and still safe data-driven approaches that leverage advanced technologies available in the digital age of operation. This project endeavored to identify two key aspects to successfully incorporate historical work execution data. First, where in the work management process is that information most pertinent? Next, what variables are key to informing the best strategy for organizing the upcoming work? The Smart Planner uses data collected by dynamic work instructions to provide a basis for suggesting requirements of similar, upcoming work packages. Further, it curbs inefficiencies of the work management process by analyzing the likelihood of discovery work, offering suggestions to build a contingency package. All this taking place as the work planner builds work packages that meet the predetermined scope of work to be performed.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Atmospheric Conditions Leading to a Fumigation Event

During the afternoon of 30 January 2022, the Savannah River Site experienced unusual temperature conditions leading to a fumigation event that triggered safety alarms and caused considerable confusion about the cause of the event. Normally, it is assumed that fumigation events occur early in the day once surface heating has begun. While most fumigation events are related to the breakup of a nocturnal inversion, this event was related to synoptic atmospheric conditions, which provided a more unique scenario that led to the fumigation event. The unusual synoptic atmospheric conditions led to the downwash and fumigation of the elevated plume, causing a pollutant to mix rapidly to the surface. These conditions could have potentially harmed workers within the facility, since the plume was directed toward a building air intake system. Here, we seek to outline the conditions that led to this unusual fumigation event and provide results of two-dimensional (2D) wind modeling of the event to characterize these conditions for future operational guidance of the facility air intake systems. This work sets the groundwork for future high-resolution modeling to explore the mechanisms and thresholds affecting fumigation on the facility-specific short distance scales and improve forecasting of non-standard fumigation events to protect human health.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Lifetime and Reducing Costs for Fish Diversion Netting Structures (Abstract)

This effort will focus on technology transfer and commercialization of antifouling coatings with an enthusiastic and engaged industrial team. Environmental requirements and operational demands call for a nontoxic coating/paint to prevent fouling on fish passage guidance netting at hydropower facilities. For example, one netting customer estimated the capital cost for compliance at $\$12$ million to $\$15$ million. This project will build partnerships between PNNL and private companies to optimize, demonstrate, mature, and commercialize a novel PNNL-developed technology that addresses this critical coating need of the hydropower industry. This effort will support modification of existing coatings for application to flexible netting structures. Industrial partners include commercial coating development specialist (Lorama), hydrophobic material manufacturer and paint developer (Dry Surface Technologies), aquatic applications specialists (Prometheus Innovations and River Connectivity Systems), and hydropower netting producer (Pacific Netting Products). Engagement with the U.S. Army Corps of Engineers (USACE) and Bureau of Reclamation (BOR), two hydropower operators, throughout the project will provide expertise and field test sites that will provide crucial proof of real-world performance data (additional details provided in Teaming section). Taylor Shellfish Farms will provide organisms and fouling expertise as well as a perspective of potential broader impacts for the blue economy. Sample netting will demonstrate performance in a range of environments for key hydropower applications. PNNL will work with industrial partners to overcome commercialization barriers as well as resolving any manufacturing or regulatory issues. This Phase 1 effort is focused on technology optimization for application to fish passage guidance netting and technology validation as verified by independent testing (through USACE, BOR, Taylor Shellfish and Prometheus Innovations). Through this effort, SLIC will be demonstrated for netting applications at technology readiness level (TRL) 5. The field test data will allow optimization of SLIC formulation and performance which is key to enabling technology transfer of a mature proven technology to industry and production of a viable commercial product specifically focused for hydropower needs.

13 HYDRO ENERGY↗

Effective Missing Value Imputation Methods for Building Monitoring Data

To understand behaviors of natural and man-made events, such as energy consumption of buildings, which accounts for 40% of energy uses in the US, we deploy automated monitoring devices to record periodic observations. However, such experimental and observation data often contains problems and irregularities that have to be cleaned up before analyses. Due to various conditions affecting sensor operations, the communication channels, recording steps, or the recording media, the recorded data might have missing values, errors, or anomalous values. An effective way to clean up these problems is to replace these missing values, errors and anomalous values with expected values, a process generally known as imputation. In this work, we survey commonly used missing value imputation techniques and compare their performance on a set of building monitoring data. To compare the different types of sensor measurements with widely varying characteristics, we use normalized root mean squared error (NRMSE) as the key metric for the effectiveness of the imputation methods. We additionally consider periodicity and run time when considering comparing methods. Through extensive testing, we find that for small gap sizes, up to 8 consecutive missing values, linear interpolation performs the best; for larger gaps stretching up to 48 consecutive missing values, K-nearest neighbors provides the most accurate imputations; for even larger gaps, more computational intensive methods, such as matrix factorization, achieve the smallest NRMSE. Additionally, we observe that these computationally intensive algorithms not only provide accurate imputations for large gaps, but are also more robust across all types of sensors.

Cho, B↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Panel Installation at Goucher College

As part of our multi-phased sustainability initiative, Goucher College is implementing a series of necessary changes to become a model “green” campus. This comprehensive approach includes implementing systems designed to reduce energy consumption, water usage, and waste production by 2030. The first phase of this holistic endeavor is to develop two independent solar projects. One will be on the Facility Management Services building (FMS) and the other will be on the Central Utility Plan (CUP). The anticipated duration of this project is expected to be 24 months. When completed, the new photovoltaic panels (PVPs) and resulting solar array system will help offset campus energy consumption. The projects will also help the College achieve its goal of working towards operating primarily on renewable energy. During initial review of the project, it was revealed replacing the roofs prior to installing new PVPs would not only provide a sound structural foundation for the projects, but the new roofing systems will also aid de-carbonization. The project’s scope is divided between two buildings. Building A: FMS is the first building and Building B: CUP is the second building.

14 SOLAR ENERGY↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Non-Oxidative Ethane Dehydrogenation in a Packed-Bed DBD Plasma Reactor

Abstract Plasma-assisted conversion of ethane (C 2 H 6 ) can produce value-added chemical building blocks using green electricity. Here we employ a simple packed-bed coaxial dielectric barrier discharge (DBD) reactor to convert C 2 H 6 at mild operating conditions unattainable by conventional thermocatalysis. Ethylene (C 2 H 4 ), acetylene (C 2 H 2 ), and methane (CH 4 ) are the main products along with small fractions of C 3 and C 4 hydrocarbons. Interestingly, the C 2 H 4 selectivity is primarily correlated to C 2 H 6 conversion, dominated by electron dissociation and recombination reactions irrespective of the dielectric properties of the packed bed material (SiO 2 , Al 2 O 3 , ZrO 2 , TiO 2 , and BaTiO 3 ), packing material size, supplied power, and C 2 H 6 concentration. While a distortion of the electric field and discharge propagation results in varying dissipated power as materials change, the C 2 H 4 energy yield remains constant. The particle size appears to affect conversion mainly due to pressure alterations. Pd/SiO 2 catalyst can change the selectivity, favoring saturated species by expending hydrogen.

Engineering↗

Longitudinal spatial hole burning in high-power semiconductor lasers: numerical analysis

Longitudinal spatial hole burning (LSHB) in high-power semiconductor lasers is analysed by numerically solving one-dimensional (1D) rate equations. Calculations are performed for GaAs-based lasers operating at a wavelength of 1.06 μm. It is shown that the LSHB-induced decrease in output power can be accounted for by two mechanisms: build-up of spontaneous recombination and decrease in slope efficiency, equivalent to a rise in internal optical loss. We analyse the influence of different laser chip parameters on the magnitude of the LSHB effect. In particular, it is shown that to suppress LSHB it is preferable to increase the optical confinement factor Γ. We examine the relationship between LSHB and other mechanisms capable of reducing the output power. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of voltage-driven oscillating insulator-metal transitions

Recent experiments demonstrated emerging alternating insulator and metal phases in Mott insulators actuated by a direct bias voltage, leading to oscillating voltage outputs with characteristic frequencies. Here, we develop a physics-based nonequilibrium model to describe the dynamics of oscillating insulator-metal phase transitions and experimentally validate it using a VO 2 device as a prototype. The oscillation frequency is shown to scale monotonically with the bias voltage and series resistance and terminate abruptly at lower and upper device-dependent limits, which are dictated by the nonequilibrium carrier dynamics. Here, we derive an approximate analytical expression for the dependence of the frequency on the device operating parameters, which yields a fundamental limit to the frequency and may be utilized to provide guidance to potential applications of insulator-metal transition materials as building blocks of brain-inspired non-von Neumann computers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling Synergistic Fuel Cell Membrane Degradation with Mitigating Effects of Cerium

During operation, polymer-electrolyte-membrane (PEM) fuel cells undergo mechanical and chemical degradation mechanisms, which behave synergistically and lead to accelerated membrane degradation over time. This study builds upon previous modeling work on mechanical degradation as described by a pinhole in the membrane and the effects of cerium on chemical degradation.1 By combining these two models, analysis can be carried out on the coupled degradation methods and how the mitigation effects of cerium disrupt the degradation cycle. The mechanical model represents a pinhole in the membrane using an effective void fraction, which allows for increased gas crossover through the membrane and impacts the membrane transport and mechanical properties. A microkinetic model for the chemical degradation is included in the model, including attack of the membrane polymer by hydroxyl radicals as well as the mitigation reaction for quenching of hydroxyl radicals with cerium. A concentrated solution theory approach is used to model the transport of cerium ions throughout the cell.2 The model results show how the location of cerium in the cell can be used to prevent chemical degradation. In addition, the model shows how cerium slows down the rate of pinhole growth by reducing the gas crossover and membrane thinning rate. Finally, the model can be used to optimize the distribution of cerium in the membrane and catalyst layers by balancing trade-offs between lowering degradation rates and decreasing fuel cell performance.

25 ENERGY STORAGE↗

AmeriFlux US-NYk NYSM - Staten Island

This is the AmeriFlux version of the carbon flux data for the site US-NYk NYSM - Staten Island. Site Description - Located in an urban setting. It is on a rooftop. Obstructions within 100m include tall buildings. The soil type is N/A - Rooftop. This site is a part of the New York State Mesonet Flux Network, one of multiple subnetworks (e.g. Profiler, Snow) operated by the New York State Mesonet. It also operates as a NYC Profiler site and a Standard meteorological site.

Miller, Scott [University at Albany]↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Materials and Fuels Complex FY-24 -- FY-28 Five-Year Investment Strategy

MFC supports current RD&D missions while enabling new projects and missions working with DOE-NE sponsors, other federal agencies, private industry, and academia. The investment strategy described in this document guides the efforts to build, expand, and sustain DOE-NE research capabilities at MFC, increase access to MFC capabilities by industry and the nuclear RD&D community, and revitalize existing MFC nuclear infrastructure. The strategy also anticipates and guides the preparations necessary for demonstration of advanced nuclear energy technologies in support of NRIC, the DOE Gateway for Accelerated Innovation in Nuclear (GAIN) initiative, and nuclear energy and other related critical outcomes identified in the INL Laboratory Plan. The investment strategy for MFC addresses building and improving on these core competencies, introducing new and revitalized RD&D capabilities, and maturing the NRIC test bed. MFC is also implementing new business and operations models to help transform MFC into a complex that supports an advanced nuclear technology development test bed. The strategy for MFC is presented in several parts, each focusing on an element needed for success.

99 GENERAL AND MISCELLANEOUS↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

Demand-adaptive Transit Design for Urban Transportation Hubs

In this study, we proposed a novel three-stage framework for planning the optimal demand-adaptive transit (DAT) at urban transportation hubs. Given the potential trip demand and road traffic condition, the proposed framework sequentially generates the optimal set of candidate routes, combines the outgoing routes and incoming routes at the hub, and derives the optimal fleet size and corresponding route frequency under the fixed budget. In particular, we build the route generation algorithm which maximizes passenger demand coverage with travel time deviation constraint. And a heuristic algorithm is further developed which yields near-optimal operation routes for real-time demand. The fleet optimization problem is formulated to minimize the weighted cost of energy savings, operation cost and trip revenue. We conduct comprehensive numerical experiments for planning DAT with electric buses at JFK airport in NYC using NYC taxi and for-hire vehicle trip data and GoogleMap speed data. The results show the superior performance of the proposed route generation algorithm which is able to cover citywide passenger demand with only 61 DAT routes. The results also suggest that the proposed DAT planning framework may serve over 47% of existing taxi and FHV demand by operating 18 routes using the fleet of 62 electric buses.

demand adaptive↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗